SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

Similar documents
SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

SmartPro Medical-Grade UPS, Line Interactive, Lithium Battery, 6 Outlets - 230V, 1kVA, 750W, Full Isolation

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

MODEL NUMBER: APS2424

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

MODEL NUMBER: APS2012

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

MODEL NUMBER: APS2448UL

MODEL NUMBER: APS750. Highlights. Package Includes. Description

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

3000W APS X Series 24VDC 230V Inverter/Charger with Pure Sine-Wave Output, Hardwired

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

MODEL NUMBER: APS3636VR

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

3 Uninterruptible Power Systems

Model #: APS V DC or 120V AC input; 120V AC output (hardwired) Auto Transfer Switching option for battery backup / UPS operation

Model #: RV1012ULHW. 12V DC or 120V AC input; 120V AC output (hardwired)

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

3 Uninterruptible Power Systems

Uninterruptible Power Systems

Aurora Single Phase Emergency Lighting Inverters

EFFEKTA Power Supplies

On-line, Single Phase, Double Conversion UPS

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Series 120/120VAC Universal Tower/Rack Mount

3 Uninterruptible Power Systems

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

UPS SYSTEMS PDUs SURGE PROTECTORS POWER INVERTERS DATACENTER UPS. Product Catalog

Uninterruptible Power Systems

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

2 Uninterruptible Power Systems

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Up to 98% efficient under full load Similar runtimes to the previous 3u model

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

Eaton 9PXM. 4-20kVA Split-Phase Rack-Tower UPS Guide Specification

3 Uninterruptible Power Systems

Uninterruptible Power Supplies

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

3 Uninterruptible Power Systems

MINUTEMAN POWER TECHNOLOGIES Endeavor LCD Series Product Specifications 1000VA 3000VA Single-phase Uninterruptible Power Supply 1.

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

» Sophisticated» Reliable» Intelligent

TECHNICAL DATA SHEET KVA UPS Systemss

POWER kva

Uninterruptible Power Systems

Liebert GXT & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

PowerValue 11/31 T kva

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

POWERTRONIX QUASAR 5-40 KVA

POWER kva

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

Master DIALOG INDUSTRY RANGE

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

Liebert GXT MT+ User Manual VA Installer/User Guide

User Manual V1.0 MaxiFlex 3000

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Protection and conditioning against all forms of power anomalies.

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

Unity output power factor single-phase double-conversion, online UPS with advanced management features

YOUR POWER IN SAFE HANDS. E Series UPS

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical data sheets

Technical Specification SENTINEL PRO

SENTINEL VA

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

Uninterruptible Power Supplies

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Smart UPS On Line 120/208 V

Technical Data Sheets

USER MANUAL DN / DN

Application. Battery. Public Grid GS HYBRID INVERTER

MKN-DSP SERIES - THREE PHASE

Uninterruptible Power System

Transcription:

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired MODEL NUMBER: SU20K3/3 Description Tripp Lite's SU20K3/3 20kVA SmartOnline 3-Phase Intelligent, True On-Line UPS System has been redesigned to save valuable space and simplify runtime scalability. Power and battery components are combined into a single, small-footprint module (the smallest in its class). A robust internal battery runtime capability can be easily extended by installing additional optional internal battery packs through the convenient front panel access door. The SU20K3/3 provides mission-critical equipment with the highest level of power protection available. Large capacity 20,000VA/16,000 watt UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. IGBT inverter technology produces output power with <3% THD (total harmonic distortion), allowing connected equipment to perform at its peak. A 3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands. Extremely efficient operation saves money by lowering electricity consumption. Hardwire input and output connections support a variety of permanent or PDU style power connections. SU20K3/3 features 120/208V AC, 3-phase, 4-wire (plus ground), wye input and output. It also features a wide input voltage correction range: 96-144/166-250V AC. Frequency is 50 or 60 Hz (auto-selectable). SU20K3/3 includes internal power and battery components in a single small-footprint tower module. Battery support can be extended with additional internal battery packs. A manual bypass switch as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power when the UPS requires maintenance. Three built-in communication ports (RS-232, contact closure and AS-400) work with included PowerAlert Software to simultaneously provide shutdown commands and reporting on multiple servers without the need for costly accessories. An accessory slot accepts an optional internal SNMP card (model # SNMPWEBCARD) for remote shutdowns, reboots and more. A Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities. Front panel combination LCD/LED display alerts users to a variety of UPS operational modes and conditions. A start-up service program is recommended to enhance the reliability of the installation. Features Highlights 20,000 VA (20kVA) tower UPS with internal batteries Saves valuable space: power and battery components combined into a single small-footprint module Simplifies runtime scalability: convenient front panel battery access for expandable runtime with additional internal battery packs 3-phase hardwire input and output (120/208VAC). Wide input voltage correction range (96-144V AC / 166-250V AC) IGBT technology and zero transfer time, on-line, double-conversion operation 3 communication ports, SNMP card slot and EPO jack Package Includes SU20K3/3 UPS System (power and battery components in one module) PowerAlert Software and cabling Warranty information Instruction manual 1 / 5

Saves valuable space: power and battery components combined into a single small-footprint module Simplifies runtime scalability: convenient front panel battery access for expandable runtime with additional internal battery packs True on-line, double conversion UPS with IGBT technology provides pure, sine wave AC output at all times Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems 20,000VA / 16,000 watt power capacity with 3-phase, hardwire 120/208V AC input/output connections Features a wide input voltage correction range: 96-144 / 166-250V AC Included internal batteries provide 13 minutes runtime at half load (8,000 watts) and 5 minutes runtime at full load (16,000 watts) 3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands Extend runtime by installing optional internal battery packs (model # SURBC2030) through the front panel access door. SU20K3/3 includes 2 internal battery packs and accepts 2 additional internal battery packs. A standalone battery module compartment with a 4 battery pack capacity and daisy-chain capability (model # SUBF2030) is available to further extend runtime. 3 communication ports (RS-232, contact closure and AS-400) Slot for optional SNMP card (model # SNMPWEBCARD) Manual bypass switch as well as an automatic bypass function ensures 100% availability of connected equipment by safely passing through AC power when the UPS system requires maintenance Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval Emergency Power Off button turns UPS output OFF and disables Bypass output PowerAlert Universal UPS Power Management Software and 6 ft. communication cable included Start-up service program is recommended to enhance the reliability of the installation Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities Combination LED/LCD display Specifications OUTPUT Output Volt Amp Capacity (VA) 20000 Output kva Capacity (kva) 20 Output Watt Capacity (Watts) 16000 Output kw Capacity (kw) 16 Power Factor 0.8 Crest Factor 3:1 Nominal Output Voltage(s) Supported Frequency Compatibility Output Voltage Regulation (Line Mode) Output Voltage Regulation (Battery Mode) Output Receptacles Output AC Waveform (AC Mode) 120/208V; 3-Phase Wye 50 / 60 Hz +/- 2% +/- 2% Hardwire Sine wave 2 / 5

Output AC Waveform (Battery Mode) Pure Sine wave INPUT Rated input current (Maximum Load) Nominal Input Voltage(s) Supported 60A 120/208V AC (3ph wye) Nominal Input Voltage Description 3-Phase Wye, 4 wire (L1, L2, L3, N, G) UPS Input Connection Type Input Phase Hardwire 3-Phase BATTERY Full Load Runtime (min.) Half Load Runtime (min.) Expandable Battery Runtime External Battery Pack Compatibility Expandable Runtime Description 5 min. (16kw) 13 min. (8kw) Supports extended runtime with 2 internal and multiple optional external battery packs BP240V99; SUBF2030 (holds 4 SURBC2030); SURBC2030; BP240V350; BP240V400; BP240V400C; BP240V500; BP240V500C Includes a battery housing with space for 2 internal SURBC2030 battery packs for extended runtime. Additional runtime capacity is available by adding SUBF2030 and additional SURBC2030 batteries - see runtime chart for specific recommendations DC System Voltage (VDC) 240 Battery Recharge Rate (Included Batteries) Internal UPS Replacement Battery Cartridge Battery Access Battery Replacement Description 2-4 hours from 10% to 90% SURBC2030 Front panel internal battery access door Hot-swappable, replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Overvoltage Correction Undervoltage Correction Online, double-conversion power conditioning Maintains continuous operation without using battery power during overvoltages to 144 / 250 (3-Phase, 4-Wire, wye), reducing output within 2% of nominal Maintains continuous operation without using battery power during brownout / undervoltage conditions to 96 / 166 (3-Phase, 4-Wire, wye) LEDS ALARMS & SWITCHES LED Indicators Front Panel LCD Display Audible Alarm Alarm Cancel Operation 7 LED DISPLAY: AC input, bypass input, AC-DC charger, DC-AC inverter, AC output, bypass operation and battery operation SELECTABLE LCD DISPLAY: indicates a wide range of UPS operational and fault/warning conditions including operational mode, alarm/shutdown conditions, input/output voltage/frequency, battery voltage, load percentage and more (see manual) Alarms warn against a variety of operational conditions: low-battery, overload, shutdown, bypass and more Power-fail alarm can be silenced using alarm-cancel switch 3 / 5

Switches ON button turns UPS's inverter ON. OFF button turns UPS's inverter OFF. Select Button browses through items displayed on LCD screen. Enter button selects items displayed on LCD screen. Select and Enter buttons used simultaneously mute UPS alarms. Battery Start Switch cold starts the inverter. Emergency Power Off button turns UPS output OFF and disables Bypass output. Manual Bypass switch bypasses the UPS's inverter during maintenance. SURGE / NOISE SUPPRESSION EMI / RFI AC Noise Suppression Yes AC Suppression Joule Rating 2032 AC Suppression Response Time Instantaneous PHYSICAL Installation Form Factors Supported with Included Accessories Primary Form Factor UPS Power Module Dimensions (hwd, in.) UPS Power Module Dimensions (hwd, cm) Installed Whole System Maximum Rack Depth (cm) Tower Tower 35.9 x 19.5 x 36.8 91.2 x 49.5 x 93.6 0 UPS Power Module Weight (lbs.) 519.2 UPS Power Module Weight (kg) 233.6 UPS Shipping Dimensions (hwd / in.) 44 x 28 x 44.4 UPS Shipping Dimensions (hwd / cm) 111.5 x 71.1 x 113 Shipping Weight (lbs.) 607.2 Shipping Weight (kg) 273.2 Cooling Method UPS Housing Material Fans Steel ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius 5 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 6068 COMMUNICATIONS Communications Interface Network Monitoring Port Description DB9 Serial; Contact closure; Slot for SNMP/Web interface RS232, contact closure and AS400 monitoring ports are supported by 3 separate DB9 ports PowerAlert Software Included 4 / 5

Communications Cable DB9 cabling included LINE / BATTERY TRANSFER Transfer Time Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) No transfer time (0 ms.) in online, double-conversion mode Maintains continuous operation during undervoltages as low as 96 / 166V AC (3-Phase, 4-Wire, wye). Below this point, output is maintained utilizing battery reserves. Maintains continuous operation during overvoltages as high as 144 / 250V AC (3-Phase, 4-Wire, wye). Above this point, output is maintained utilizing battery reserves. SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) High Availability UPS Features Cold-start operation supported Automatic inverter bypass; Hot swappable batteries CERTIFICATIONS UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) WARRANTY Product Warranty Period (U.S. & Canada) Product Warranty Period (International) Product Warranty Period (Mexico) Product Warranty Period (Puerto Rico) 2-year limited warranty 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products. 5 / 5