nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

Similar documents
RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

AME. Rectifier - Battery charger. Industrial applications: Key features:

Industrial Chargers and

AMS. Rectifier - Battery charger. Industrial applications: Key features: VRLA batteries with output voltage from 24, 48, 110, 220 Vdc up to 30A

DC POWER SUPPLY SYSTEMS

QUEENSLAND URBAN UTILITIES

TECHNICAL DATA SHEET KVA UPS Systemss

Technical Data Sheets

Technical Data Sheets

Liebert. FP 50Z kva

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Data Sheets

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Technical Data Sheets

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

AT30 SERIES BATTERY CHARGER

POWERTRONIX QUASAR 5-40 KVA

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

Technical Data Sheets

FINHRM FINHRM5 FINHRMA FINHRMAC

AT EVO SERIES BATTERY CHARGER

Technical Data Sheets

SECTION DC POWER SUPPLY/BATTERY CHARGER

Three Phase UPS Systems Range: 10 to 500kVA

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Technical Data Sheets

POWER kva

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

ATevo SERIES BATTERY CHARGER

EMEX. Central Battery Systems Emergency Lighting

PowerValue 11/31 T kva

Master Plus kva

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

TLE Series UPS 400/500 kw With eboost Technology

EVO AT SERIES BATTERY CHARGER

POWER kva

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

RVS-DN Digital Reduced Voltage Motor Starter

Power Conversion Systems. SCHAEFER International. Switchmode Power Supplies, Chargers & Inverters. Thyristor-controlled Power Supplies & Chargers

Phase Modular Finally the benefits of Modular ups are for all

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Master DIALOG INDUSTRY RANGE

Marketing Management Team of Europe

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

A36D CONTROLLED FERRORESONANT RECTIFIER / POWER SUPPLY BATTERY CHARGER / POWER SUPPLY. Standard Features

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Central Battery Systems Loadstar AC/DC Systems

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

Keatec Energy Catalogue 2018 Telecommunications

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

UPS Multi Sentry 10-20kVA

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TLE Series UPS 160/200/225/250 kw with eboost Technology

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

EFFEKTA Power Supplies

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

TOSHIBA G , 750kVA

AT SERIES EVO BATTERY CHARGER

ABB central inverters ULTRA-750/1100/ kW to 1560kW

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

MTPi2000C - 80 KW (RANGE)

TLE Series UPS 750/1000 kw With eboost Technology

Master MPS kva kva 3:1 3:3 VFI TYPE

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

SSL-1500 (12V/24V/48V) / SSL-3000 (12V/24V/48V)

Industrial Power Supplies

Sola/Hevi-Duty S3K Series Mini-Tower UPS

CTU 02. Thyristor switching module for fast PF compensation. User manual

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

TECHNICAL DATA SHEET LAD/CYCLER16KW

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Transcription:

RELIABLE SOLUTIONS in POWER ELECTRONICS Power Management Instruments DC Battery Charger / Automation Type Distributed by : nonstopower sdn bhd (822490-P) no. 78 & 80, jalan rimbunan raya, laman rimbunan, kepong, 52100 kuala lumpur, malaysia. tel 603 6253 3588 (10 lines) fax 603 6253 2533, 603 6253 6533 email sales@nonstopower.com

DC BATTERY CHARGER / RECTIFIER RDA / RDAT AUTOMATION TYPE SERIES FULLY CONTROLLED THRYSTOR RECTIFIER MODULE COMPLETE ISOLATION GESS DC Chargers are fully isolated since an isolation transformer is placed in between the input and output and because the DC current is controlled by a DC current module. Therefore, the load is always safe even at high input voltage and congested mains conditions. In addition, the failure risk is minimized as semi-conductors are used for the rectifier. Standard L-C filters at the output maintain safe charging of the battery groups. HIGH PROTECTION The Battery Charger is SCR controlled AC/DC rectifier with automatic constant voltage and constant current ability. On LCD panel, all key parameters, real time base events and failures can be tracked and communicate remotely via RS 232 / RS 485 port or modbus. All operations are controlled and progressed by micro controller. Output current, battery current, boost and Float Charge Voltages are adjust- able on the user-friendly control panel. Adjustable timer is used for boost charging the batteries automatically and is a decremented counter by one hour. The Charger output gives the boost charging voltage by setting the timer to any value larger than zero. The Charger returns to floating voltage level when the timer value reaches to zero. 2

STANDART FEATURES Adjustable Timer for Boost Charging Adjustable Boost and Float Charge Voltages Automatic Boost Charge Selection according to boost / float current set value Adjustable Rectifier Output Current and Battery Charge Current LCD Display for DC Load / Battery Voltage, DC Load / Battery Current, Input AC Voltage / Line Current / Frequency Event History for all Electrical values and failures Automatic and Manuel Battery Test Boost inhibit facility for interlock redundant application Output Filter Inductor and DC Longlife Capacitor Electronic Over / Under Voltage, Over Current and Short Circuit Protections Isolated Output by Input Transformer and output halleffect current module Parallel Redundant Operation Boost and Float dropper control output for Ni-Cd and Lead Acid Battery Input Filter and input surge Voltage protection Internal Over Temperature protection Temperature Compensation for Battery Low Battery Indication and Alarm contacts Rectifier Failure Indication and Alarm contacts Rectifier Over Voltage Indication and Alarm contacts Over Temperature Indication and Alarm contacts Line Failure Indication and Alarm contacts Input MCB Indication and Alarm contacts Load MCB Indication and Alarm contacts Battery MCB Indication and Alarm contacts Earth Fault Indication and Alarm contacts Reverse Battery Connection Protection Reset Button RS- 232 communication OPTIONS 485 / Modbus / TCP / IP and modbus Silicon Dropper Module For Load Output (Load voltage output ± 5 %) Rectifier and Battery Group with the same cabinent LVD Deep Discharge Battery Protection contactor AUTOMATIC BOOST Automatic boost charge can also be selected on menu. The automatic boost menu has the options for selecting the boost and float current based on battery capacity. Suitable float and boost currents of the battery are set before selecting the automatic boost option. After the set-up, the automatic boost function will monitor the battery current and select boost or float option by referring to the set values. If the charging current is higher than the set boost current, the system will select boost and if the charging current is lower than the set float current the system will select float option. In case of low battery alarm, the automatic boost will select boost option until the battery charging current reaches to the set float value. PROTECTIONS The input and output of the charger are protected against improper use and line disturbances electronically. Input and output can be switched by circuit breakers individually. It has self-protection against over temperature. The alarm contacts can be used for external system in the case of any anomaly. The output is fully isolated from the AC line input. The Charger has a modular design to provide service and maintenance simplicity. PARALLEL/SERIAL CONNECTION The Charger has a modular design to provide service and maintenance simplicity. The outputs of the Battery Chargers can be connected in parallel or in series based on the requirement (N+1). DC Ripple < 1% Input and output are protected with MCBs and all settings like boost charge, floating charge and battery charge current can be adjusted via front panel touch pad digitally. DC output is filtered by L/C, so DC ripple at full load always lower than 1% to increase battery life. All rectifiers have standards low-battery and rectifier failure alarm. WIDE RANGE OF USE DC chargers are ideal for transformer energy distribution centers, gas oil energy distribution centers, natural gas energy distribution centers, mining industry security and lighting, building automation systems and for special telecommunication applications. 3

DC CHARGER / RECTIFIER GENERAL Model Monophase Input Threephase Input Topology INPUT Nominal Voltage Nominal Frequency 50 / 60 Hz ±5% Power Factor Transformer ITHD Input Protection OUTPUT 6 Pulse Thyristor controlled AC/DC Rectifier with input isolation transformer Optional 12 Pulse Thyristor controlled AC/DC Rectifier with input isolation transformer 110 VAC / 115VAC /208 VAC / 220 VAC / 230 VAC / 240 VAC ±15% >0.8 (>0.95 with 12 Pulse Rectifier) Galvanically isolated <30% (standard); <10% (with 12 Pulse Rectifier) Thermic Magnetic Overcurrent protection MCB, Overvoltage protection Floating Output Voltage 12/24 VDC±1% / 48 VDC±1% / 110 VDC±1% / 220 VDC ±1% Output Voltage Adjustment Output Current Adjustment Boost Charge Voltage Boost voltage (V/C) Float voltage (V/C) Equalize voltage (V/C) Nominal Output Current Maximum Output Current Output Ripple Dynamic Response (w/out battery group) Dynamic Response (with battery group) Battery Charging Principle Output Protection Filtering GENERAL Boost Timer Cooling Isolation Voltage 190 VAC / 200 VAC /380 VAC / 400 VAC / 415 / 480 VAC ±15% 12/24VDC output: 10VDC to 30VDC, 48VDC output: 40VDC to 60VDC, 110VDC output: 80VDC to 150VDC, 220VDC output: 190VDC to 290VDC 0-100% of Nominal Output Current 100% to 120% of Floating Output Voltage 2,4 lead acid battery 1,55 NiCd Battery 2,23 lead acid battery 1,40 NiCd battery 2,7 lead acid battery 1,7 NiCd battery with reduced current 25A / 50A / 100A / 200A / 300A / 400A 110% of nominal output current 1% RMS AC of Output Voltage ±5% of Output Voltage (25% load change at 50% load) ±2% of Output Voltage (100% load change) Constant Current/ Constant Voltage Short Circuit, MCB and Overvoltage protection L-C Filter 0 99.9 hours adjustable Forced fans with smart fan controlling system 2500VAC input/chassis and output/chassis Efficiency at full load >90% >92% MTBF Operating Temperature -10 / + 50 ºC Protection Level Enclosure Material Cable Entry Access to Batteries Relative Humidity Circuit Breakers Silicon Dropper Reset Button Boost inhibit DISPLAY PANEL Measurements Indicators Buttons Event History 100,000 Hrs. (w/out battery group) IP20 (Standard); IP54 (Optional) Mild Steel, Zinc-phosphate coated; 100 µm electrostatic paint; 1.5 mm thickness Front Botttom Batteries and rectifier in the same cabinet with front access (optional) 5% to 90% non condensing Thermic magnetic circuit breakers for Input, Battery and Load ( up to 100A) Available on request (For load output) Short Circuit, Overvoltage protection, MCB and Phase Sequence Protection Used for re-operation in case of failure of the system. (Without disconnecting the load from battery group) Interlock application inhibits one of the rectifiers for boost operation in parallel redundant mode LCD Displays for Load Output Voltage / Current, Battery Output Voltage / Current and Line Voltage / Line Current / Frequency Boost Charging, Float Charging, Charger Failure, Over voltage, Over temperature, Low battery, Under voltage, Battery endıng, Battery test, Earth Fault and Input Power OK. Timer Setting, Boost Voltage Setting, Float Voltage Setting,Output current setting, battery current setting, automatic boost setting and Reset buttons. AC Line Input high / Low, Rectifier output high / Low, Battery test failed, Over temperature, Low Battery, Line / Battery / Load MCB events are displayed on time base (Last 250 events). 4

ALARM CONTACTS Charger Failure Low Battery Rectifier over voltage Over temperature Line Failure Load MCB Battery MCB Line MCB ENVIRONMENT Operating Temperature -10 / +50 C Relative Humidity 5-90 % Operating Altitude Noise Level Electrical Standards COMMUNICATION & PARALLELING Communication Paralleling Max. 3000 Mt. Max. 60 db EN 50091-1 (Security) / EN 50091-2 (EMC) Standard RS 232 communiciation on real time base for remote monitoring and control. Optional RS 485 / Modbus / TCP IP communiciation. N+1 (No need for extra kit for paralleling) MONO PHASE INPUT Output Voltage Output Current Height Width Depth 12 / 24 V DC 10 AMP. 410 220 330 15 Weight (kg) 12 / 24 V DC 30 AMP. 410 220 330 36.5 12 / 24 V DC 60 AMP. 570 390 410 51.5 12 / 24 V DC 100 AMP. 660 380 480 95 48 V DC 10 AMP. 410 220 330 20 48 V DC 30 AMP. 570 390 410 40 48 V DC 60 AMP. 660 380 480 65 48 V DC 100 AMP. 730 450 530 85 110 V DC 10 AMP. 570 390 410 45 110 V DC 30 AMP. 570 390 410 65.5 110 V DC 60 AMP. 730 450 530 80 110 V DC 100 AMP. 730 450 530 190 THREE PHASE INPUT Output Voltage Output Current Height Width Depth Weight (kg) BATTERY CHARGING CHARACTERISTICS 12 / 24 V DC 30 AMP. 570 390 410 45 12 / 24 V DC 60 AMP. 660 380 480 73 12 / 24 V DC 100 AMP. 660 380 480 90 12 / 24 V DC 200 AMP. 730 450 530 120 48 V DC 30 AMP. 570 390 410 55 48 V DC 60 AMP. 660 380 480 65 48 V DC 100 AMP. 730 450 530 90 48 V DC 200 AMP. 770 510 710 120 110 V DC 10 AMP. 570 390 410 65 110 V DC 30 AMP. 660 380 480 78.5 110 V DC 60 AMP. 700 450 530 92 110 V DC 100 AMP. 770 510 710 169 110 V DC 200 AMP. 1100 650 600 210 220 V DC 10 AMP. 660 380 480 78 220 V DC 30 AMP. 660 380 480 90 220 V DC 60 AMP. 770 510 710 110 220 V DC 5 100 AMP. 770 510 710 235 220 V DC 150 AMP. 770 510 710 365 * Available up to 220VDC 500Amp