Linear Luminaire with LED Series EXLUX 6402/2

Similar documents
Linear Luminaire with LED Series EXLUX 6002

LED Linear Luminaire Series EXLUX 6402

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear luminaire with LED Series EXLUX 6002

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Floodlight LED Series 6525

Floodlight LED Series 6125

Floodlight LED Series 6525

Compact Sheet-Steel Light Fittings Series 6114/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire with LED

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Tubular Light Fitting with LED Series 6036

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

7 Lighting Technology

Linear Luminaire for Fluorescent Lamps

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Plug and Socket Devices SolConeX 16 A Series 8570

Floodlight Series 6121

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Load disconnect switch Series 8146/5-V11

Floodlight Series 6521/4

Terminal Boxes Series 8125

Compact Sheet-Steel Light Fittings Series 6114

Sheet-Steel Light Fittings Series 6014 / 6414

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Position Switches Series 8074/2

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Position Switches Series 8060/2

7 Lighting Technology

7 Lighting Technology

Position Switches Series 8070/2

Sheet Steel Emergency Light Fitting Series 6018

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Linear fittings EVDL LED fitting - zones 21, & 22

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Ex UPS standard Series 8265

Linear fittings EVNL LED fitting - zones 2, & 22

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Control Buttons / Switches for Panel Mounting Series 8003

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Terminal Boxes Series 8125

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Control switch/load disconnect switch Series 8008

Load and Motor Switches, Load-Break Switches Series 8549

Load and Motor Switches, Load-Break Switches Series 8544

Linear fluorescent luminaire LED V-CG-S

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

EXEL-L. Detail of the internal side. Transparent polycarbonate

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Load and Motor Switches, Load-Break Switches Series 8544

7 Lighting Technology

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Safety Switches Series 8537

Battery Boxes Series 8316

Control Device System NEC Series ConSig 8040

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVN Fluorescent fitting - zones 2 & 22

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Tank Inspection Lights Series 6122

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Control Buttons Series 8082

Operating Instructions

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-RECESSED CEILING LIGHT FITTINGS

FHL. Ex d. Body in aluminium

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Emergency Luminaire with LED

Easy and safe installation

10 Load and Motor Switchgear

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Pendant Light Fitting IEC

Operating Instructions

Transcription:

> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened (option) > Type of protection gas: na (non sparking) www.stahl.de ATEX / IECEx Zone 0 1 2 20 21 22 For use in: x x x Explosion Protection Global (IECEx) Gas and dust IECEx IBE 14.0080X EX na d op is IIC T4 Gc EX tb IIIC T100 C Db EX tc IIIC T100 C Dc Europe (ATEX) Dust IBExU14ATEX1292 E II 2 D Ex tb IIIC T100 C Db Gas and dust Certifications and certificates Certificates IBExU14ATEXB020 X E II 3 G Ex na d op is IIC T4 Gc E II 3 D Ex tc IIIC T100 C Dc IECEx, ATEX 16745E00 WebCode 6402B Lighting /1

Selection Table Version Diffusor Length Power consumption mm Cable entry Order number Art. no. Weight kg EXLUX 6402/2 with 700 28 W M25 6402/2182-5500-250 244216 4.200 M20 6402/2182-5500-150 244217 4.200 1310 52 W M25 6402/2284-5500-250 244218 6.400 NOTE The light fittings are delivered without mounting material. These accessories must be ordered separately! M20 6402/2284-5500-150 244219 6.400 Technical Data Electrical data Ballast Inrush current AC: 220... V ±10 %; 50... 60 Hz DC: 200... 250 V ±10 % I peak = 53.5 A; Δt = 124.8 ms maximum number of luminaires per miniature circuit breaker: Power factor ) 0.93 Type 10 A 16 A 20 A 25 A B 8 12 16 20 C 13 21 27 33 Degree of protection IP66 / IP67 (IEC 60598) Protection class I (with internal PE connection) Impact strength (IK code) IK10 (IEC 62262) Disconnection of the light When opening the luminaire Switch with safety lock (optional); when opening the central lock all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are positive opening, they can only be switched on again when the luminaire trough and the central locking system are closed. Luminous characteristics Luminous flux 6402/21.2-.5..-..0 Power consumption [W] 28 52 28 52 Colour rendering [Ra] 80 80 70 70 Colour temperature [K] 5000 5000 5700 5700 6402/22.4-.5..-..0 6402/21.2-.5..-..1 6402/22.4-.5..-..1 without diffuser Luminous flux [lm] 3100 6200 3400 6800 Luminaire efficiency [lm/w] 111 119 121 131 with diffuser Luminous flux [lm] 2550 5100 2800 5600 Luminaire efficiency [lm/w] 91 98 100 108 Values apply to T a = +25 C. Luminous flux decrease at T a = +55 C to 85% of the nominal value. /2 Lighting

Technical Data Ambient conditions Operating temperature -30... +55 C range Storage -30... +75 C Service life Service life T a ( 25 C T a ( 45 C T a ( 55 C L 70B 10C 10 100,000 h 100,000 h 50,000 h L xb yc z At the end of the service life: Luminous flux decrease to "x" percent up to "y" percent of all luminaires fall below "x" up to "z" percent of all luminaires break down completely Mechanical data Material Enclosure Material Polyester resin, glass fibre-reinforced Colour colour grey, similar to RAL 7035 Seal Silicone foam gasket in the lamp cover Translucent cover Polycarbonate Luminaire locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Mounting / Installation Cable glands Standard luminaire Plastic: Metal: 2 x M25 x 1.5 cable gland 8161 and 2 x M25 x 1.5 stopping plugs 8290 (enclosed) 2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries Attention: cable entries must be ordered separately Special: max. 4 bores for M20, M25, NPSM ½ max. 2 bores for NPT ¾ Metal cable glands: M20 x 1.5, M25 x 1.5; earthing of the metal cable entries by means of metal plates Connection Standard: Spring clamp terminals 5-pole: L1, L2, L3, N, PE (with through wiring) Clamping range: 1 x 0.75... 4 mm 2 (solid/finely stranded) (2 free clamping units for each pole available) Special: Terminal block with covering 5-pole: L1, L2, L3, N, PE Clamping range: 2x 0.75... 6 mm 2 (solid); 2 x 0.75... 4 mm 2 (finely and extra finely stranded) Through wiring Standard light fitting with Light fittings are equipped with internal through wiring. Ingoing and outgoing leads can be connected to the opposite sides. Terminals: see techn. data Wiring cross section: 2.5 mm 2 for max. 16 A. Assembly Optional Standard luminaire without On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). Standard: Special: 2 x M8 insert nuts in the enclosure Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires L = 700 mm: 320... 480 mm; L = 1310 mm: 670... 930 mm) Lighting /3

Light distribution curves 16615E00 28 W without diffusor 28 W with diffusor 16616E00 16617E00 52 W without diffusor 52 W with diffusor 16618E00 /4 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight Lamp cover for luminaire L=700 222427 0.639 Socket key for luminaire L=1310 222428 1.149 for luminaire L=700 (resistant to aromatic substances) 256534 0.639 for luminaire L=1310 (resistant to aromatic substances) 256535 1.149 M8 / wrench size 13; to open/close the central locking kg 222430 0.210 Ring bolt 15507E00 M8, direct mounting in insert nuts 115736 0.112 05378E00 Pipe clamp R 1 1 / 2 222459 1.200 R 1 1 / 4 222458 1.250 R 2 222460 1.300 15583E00 with mounting rail for a variable mounting distance; Material: stainless steel Mounting bracket mounting clamp mounted on a mounting rail for a variable mounting distance 222456 0.400 15585E00 Mounting rail for a variable mounting distance 222826 0.300 15584E00 Pole mounting sleeve for the subsequent mounting on lights 18 W and 36 W, completely with assembly parts 227512 3.200 16985E00 Ceiling and wallmounting bracket 222827 2.400 Bracket for wall mounting with tube 15586E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 05460E00 Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.026 10809E00 Lighting /5

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations b L1 L2 M25 x 1,5 L3 M25 x 1,5 h1 15440E00 Dimensions Luminaire 28 W 52 W L1 700 [27.56] 1310 [51.57] L2 1) 400 [15.75] 800 [31.50] L3 2) 320... 480 [12.60... 18.90] 670... 930 [26.38... 36.61] b 184 [7.24] 184 [7.24] h1 125 [4.92] 125 [4.92] 1) fixed mounting distance 2) variable mounting distance EXLUX 6402 Standard luminaire Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations 30,50 [ 1, 20 ] 12 [ 0, 47 ] 215 [ 8.46] 18,50 [ 0, 73 ] 30 [1,18]. 9 [0,35] 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 86 [ 3, 39] 74 [ 2, 91] 32 [1,26] 6,10 [0,24] ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] 13 [0,51] 215 [ 8, 46] 193-198 [7,60. - 7,80]. 143 [5,63] 15778E00 15779E00 Mounting rail /6 Lighting

Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations ø 20 [ø 0,79] 24 [0,95] ø 42 [ø 1 1/4] ø 48 [ø 1 1/2] ø 60 [ø 2] 162 [6,38] 172 [6,77] 180,50 [1 1/4] 187,50 [1 1/2] 200,50 [2] 15782E00 15781E00 15783E00 Ring bolt fitted in insert nut of the luminaire 10x15 A Mounting bracket fitted in mounting rail Pipe clamp fitted in mounting rail A [1,39] 34 65,50-74,50 [2,58-2,93] 110 [4,33] 8,50 [0,35] 296 [11,65] 8,50 [0,35] 15780E00 Wall mounting bracket fitted in mounting rail 198 [7,80] [6,30] 42 [ 1,65] 120 [4,72] 143 [5,63] 104 [4,09] ø 10,50 [ ø 0,41] 130 [5,12] 220 [8,66] 03257E00 Bracket for wall mounting with pipe section 15 SW 5 20 [0,79] 180 [7,09] 400 [15,75] We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /7