LyteLaunch Dry - Wet and DMX Models. Operation Manual

Similar documents
FL 150 XT-2 B, F, and C

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

POWER COLOR FAST STOP OFF SLOW. AfterDark IMPORTANT INFORMATION

F L B Metal Halide Light Generator for Fiber Optic Lighting Systems

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

HLS Watt Halogen Illuminator Service Manual

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

LED Convertible Dual Fixture Work Light on Tripod Stand

FiberSource Q150. user manual P/N

HEPA AIR FILTRATION SYSTEM

USER MANUAL LUX-LD30W LED MOVING HEAD

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

The 601 Illuminator OPERATION AND MAINTENANCE MANUAL. US Version

SOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216

INSTALLATION INSTRUCTIONS

Measurements are expressed in millimeters.

FL Halogen light generator for use with fibre optic lighting. Mounting and installation instruction. Item no.: FL 20-2 Ø9 230V

SUPERVISION 150C LIGHT SOURCE INTRODUCTION.. 1 INSTALLATION.2 CONTROL SYSTEMS & SETTINGS 5 GENERAL OPERATION & MAINTENANCE..10 TROUBLESHOOTING..

BL7000 SYSTEM OPERATING MANUAL

COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL

USE AND CARE GUIDE 2500 LUMEN LED PORTABLE WORKLIGHT

Centrifuge Operator / Service Manual

ECO CFL. with Photocell. Instructions. Model: ECO2DD Model: ECO3DD

Installation Instructions

Instruction Manual. H.I.D Digital Ballasts 400W 600W 1000W. All our ballasts are compatible with Safe Grow Hydroponic Smart System.

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

Luminaires - Worklight. Worklight

USE AND CARE GUIDE 7000 LUMEN TWIN HEAD LED WORKLIGHT WITH TRIPOD

Elektralite LED Pro Line Pancake USER MANUAL (Version 2)

USER MANUAL PAR56 LED PAR CANS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

INSTALLATION INSTRUCTIONS

Sirius Illuminator Range

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

LIGHT SOURCE INSTALLATION GUIDE

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTRUCTION MANUAL. All PrimeTime Studio Lights are equipped with advanced reflector technology.

SSX-180ST. SolarMaxx 180 Illuminator Service Manual

Mania EF1 user manual

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Light Source User Guide

CH-158 Color Bank 8 USER MANUAL

4000 SYSTEM OPERATING MANUAL

TECHNICAL INFORMATION Puissant 30-Watt Shortwave UV Light Sources Catalog Nos. SKSUV30, SKSUV40

MOVING HEAD. User manual CAUTION!

FL 1000 XT C DMX. User manual

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

Operations Manual Eagle 1000 Series Stretch Wrapper

X24 Projector Original Instructions

Operation Manual. Ultraviolet Fluorescent Lighting Fixtures EM-22D EM-42D

AvaLight-DHS Deuterium Halogen Light Source Operating manual

Installation Instructions: Eco SpunBay LED High Bays

OUTDOOR TRACK. LABELS Assembled in America

Operation Manual. Select/DMX 4Bank

Operation Manual. Mega 4Bank DMX Universal

INSTALLATION GUIDES OUTDOOR LIVING

Model: ECO1FL Model: ECO2FL Model: ECO3FL. Installation & Operating Instructions ECO CFL Flood Light Uncontrolled

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

FL B. Halogen light generator for Fibre optic lighting systems

Light Source User Guide

30A SMART ENERGY MANAGEMENT SYSTEM TM

SUREFIRE 512 STOVE SENTRY INSTRUCTION MANUAL

BRAVO Inverter/Battery Charger. Table of Contents

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

ASSEMBLY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

CLASS # GAUGE ROUND POWER CORDS

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

CFL-LED-KIT Compact FloodLight, LED 2.0 Upgrade Kit kl_cfl_ledkit_spec.pdf

Power Inverter 400 MW Owner s Manual

LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord

SSX-300ST SolarMaxx 300 Illuminator

Operating instructions minipuls C200

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

Model 2300DL Installation Guide

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

LED IMPORTANT SAFETY INSTRUCTIONS

STATIC DAYLIGHT PAR 575 VF

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

LED IMPORTANT SAFETY INSTRUCTIONS

2000 Watt Telescoping Light Mast - 30' 3-Stage Light Tower Rotating Boom - High Mast Lighting

Example: DWAE51L840-4-UNV-MD360W. Lumen Package Color Temp. Length Voltage Driver Options Installed

VLT SERIES. True Sine Wave AC Power Inverter. Owner s Manual. Owner s Manual D Rev.B

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

Operations and Service Manual. X30208 Load Bank

innovations in battery charging

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Installation Instruction ALG Series LED Area Light Version: 3.1

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

Installation Manual. English. French

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Transcription:

LyteLaunch -150 Dry - Wet and DMX Models Operation Manual

LyteLaunch 150 Introduction Thank you for purchasing the LyteLaunch 150 from Advanced Lighting Systems, Inc. This fiber optic lighting illuminator has been engineered and designed to be simple to operate, energy efficient and reliable. The LyteLaunch 150 is a 150 watt HID metal halide portable luminaire, designed to illuminate both sidelight and end light fiber optic cables. Each unit includes a fiber cable connection ferrule system with a compression fitting to accommodate all types of fiber. Each unit includes a power cord with a plug that connects to power and activates the lamp. Color wheel units include a switch to start and stop the rotation of the color wheel. Safety features built in are fuse protection, and cover cut off switch. The LyteLaunch-150D is designed for dry indoor applications only. The LyteLaunch-150W is designed for dry or wet area applications. This illuminator may be installed in any position indoors and horizontally only outdoors. Warning - Risk of Electrical Shock Installation & Operation Read All Instructions Save These Instructions For Future Reference. Warning - Light and Heat energy emitted from this unit could cause skin burns and damage to eyesight. Caution - risk of exposure to excessive ultraviolet (UV) radiation - Do not operate without complete lamp enclosure in place or if glass lens is damaged. Install the LyteLaunch 150 following the guidelines in the Location and Mounting Requirements and Wet Location Use sections of this manual. The LyteLaunch 150 is normally shipped with the lamp installed. If the unit is shipped without the lamp installed, refer to the Instructions for Re-Lamping section of this manual. Insert the fiber optic cable in the LyteLaunch 150 ferrule system. The fiber optic cable must always be installed with the fiber positioned exactly even with the end of the ferrule shaft which extends into the illuminator. Allowing the fiber to extend beyond the shaft or to be recessed in the shaft will cause excessive heat and will cause damage the fiber. With the fiber properly positioned, hand tighten the black plastic compression fitting to hold the fiber cable in place. Insert the ferrule shaft into the illuminator and lock the ferrule flange in place using the two screws mounted on either side of the illuminator ferrule opening. Connect the LyteLaunch 150 to power following the guidelines in the Location and Mounting Requirements and Wet Location Use sections of this manual. The lamp will immediately begin to strike. Allow approximately 5 minutes for lamp to reach full intensity.

LyteLaunch 150 Technical Specifications Power: 120V 50/60 Hz. - 180 Watts total power consumption. Lamp: Philips CDM-SA/R150 with UV Fadeblock Dimensions: 6.5 /16.5cm Width X 11 /27.94cm Length X 7.75 /19.7cm Height (DMX module adds 3.75 /9,525cm to Height) Weight: 8 lbs/3.628kg. Max. Recommended Ambient Temp: 95 F. Forced Air Ventilation: 56 CFM Nominal Operational Noise: 28db UL and C-UL listed as a Portable Luminaire for dry and wet locations. Front View - Dry or Wet Model Ferrule Mounted Air Intake Louvers Rear View - Dry Model Mounting Holes Exhaust Fan Optional Color Wheel Switch Power Cord

Location and Mounting Requirements The LyteLaunch 150 dry location model must be mounted either horizontally (feet down or feet to wall) or vertically with fan on top. Never mount the unit with the fan on bottom. The LyteLaunch 150 wet location model must be mounted horizontally (feet down only) to a surface. It is recommended that it be placed in an elevated location to prevent potential flooding. Be sure to take necessary measures to prevent the build up of snow, ice or organic material which may prevent proper airflow. Allow for a twelve inch clearance for both the in-take and exhaust sides from any surfaces to maintain proper ventilation. When mounting multiple illuminators within close proximity, maintain a two foot clearance between each illuminator. The maximum operating temperature is 95 degrees F. If unit is to be placed on a horizontal surface such as floor or shelf, be sure that the surface is clean and does not have protruding elements such as insulation, sawdust or paper that may be drawn into the illuminator causing fan failure or internal damage. Such items may create risk of fire. For secured attachment, mount the unit by screwing the feet to the surface. If mounting unit on a vertical surface or wall, be sure that the wall is capable of holding the illuminator weight. To mount to a metallic or wood surface, hold unit onto surface where it will be located and mark holes. Mount the illuminator with #10 screws appropriate for surface material. To mount to a dry wall surface, hold unit onto surface where it will be located and mark holes. Drill in dry wall anchors. Mount the illuminator with #10 screws appropriate for dry wall anchors chosen. When planning for power for this illuminator, locate the illuminator within five feet of the power source. Wet Location Use WARNING: when using outdoor use portable luminaires, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and personal injury. Read All Instructions Use only three-wire outdoor extension cords that have three-prong grounding plugs and grounding receptacles that accept the illuminators plug. Ground Fault circuit Interrupter (GFCI) protection is to be provided on the circuits(s) or outlet(s) to be used for the wet location portable luminaire. Receptacles are available having built-in GFCI protection and are able to be used for this measure of safety. Use only with an extension cord for outdoor use, such as an extension cord of cord type SW,SW-A, SOW, SOW-A, STOW, STOW-A, SJW, SJW-A, SJOW, SJOW-A, SJTW, SJTW-A or SJTOW, SJTOW-A. Save These Instructions

Instructions For Re-Lamping The LyteLaunch 150 fiber optic illuminator uses a 150 watt metal halide lamp available from Advanced Lighting Systems, Inc. or an authorized dealer. It is recommended that the lamp be changed every 5000 hours. Do not wait for lamp failure before changing lamps. Lamp failure may not occur until lamp performance is below minimum tolerances. For even illumination of sites with multiple illuminators installed, it is recommended that all lamps be changed at the same time. Lamp cord in proper position Safety Cut - out switch Fuse Holder Lamp reflector retaining flanges Lamp reflector retaining screw Lamp cord connector 1. Disconnect units power cord from power supply. 2. Allow unit to cool for a minimum of 20 minutes before proceeding. 3. Remove the two lid retaining screws located on the lid of the unit. Remove lid. 4. Disconnect lamp cord connector 5. Remove lamp reflector retaining screw from top corner of lamp. 6. Remove lamp by lifting lamp straight up and out of lamp retaining flanges. 7. Install the new lamp by inserting the lip of the lamp reflector into the retaining flanges. Reinstall the lamp reflector retaining screw. Reconnect the lamp cord connector making sure that excess lamp cord is inserted into it s proper position around side of fan. 8. Replace lid and reinsert two lid retaining screws. 9. Connect unit to power supply. Allow approximately 5 minutes for lamp to reach full intensity.

DMX Control The LyteLaunch 150 with the DMX option installed, is DMX 512 capable. Programming set up may be needed. The color wheel can be operated by an external signal. This signal can be delivered through either of the XLR connectors located on the illuminator. The remaining connector can be used as an output signal (in the case of a daisy chain) or left un-used. Consult the instructions for the DMX controller or other signal processor that will be used for programming instructions. Initialization of DMX When the main power switch on the front of the illuminator is turned on, the illuminator will run a self-test. This self-test verifies that the illuminator is functioning properly. Selecting Color Manually Color wheels may be adjusted manually to display a specific frame of color from the illuminator. 1. Turn the Adjustment Knobs to corresponding indicator number to set the desired color. The color wheel has eight color frames. See DMX table below. Setting the Base DMX Address As with all products that are DMX controlled, the LyteLaunch 150 requires that DMX channels be set to specific "addresses" in order that the illuminator will respond to specific channels from a control unit. Using the adjustment knobs, set the desired DMX address for the illuminator. See table below. The LyteLaunch 150 uses 2 DMX channels on the control board. CHANNEL 1 - color wheel position selection channel. CHANNEL 2 - color wheel speed and movement characteristics. The DMX program allows a DMX controller complete control of color wheel movement. Using channel 1 - from a stopped position, the operator selects the color wheel speed from 0 (slowest) to 100 (fastest). Using channel 2, the operator selects the position for the color wheel to move to. When cued by the controller, the wheel will move to the set position at the set speed. The wheel will turn either clockwise or counter clockwise depending on which is the shortest distance to the next point. If DMX controlled continuous rotation is required, the programmer should use an effect or cue loop to send regular position updates to the illuminator (s). This will insure that all addressed illuminators stay in sync with each other. Color DMX % Value DMX Decimal Value White 00% 000 Red 13% 033 Purple 25% 064 Dark Blue 37% 095 Lt. Blue 50% 128 Green 62% 160 Yellow 75% 192 Orange 87% 223

Selecting Stand Alone Programs The LyteLaunch 150 illuminator has pre-programmed cues stored in its memory. These may be played back. A "cue" is a pre-programmed list of colors that the illuminator will cycle through at a given rate and hold value. 1. Using the front panel Adjustment Knobs, select the desired stand alone program. (see table below for programs). PRE SET CODES 601 is 1 rpm smooth movement 602 is 2 rpm smooth movement 603 is 3 rpm smooth movement Continuing up to 620 at 20 rpm smooth movement. 622 is snap to each color every 2 seconds. 625 is snap to each color every 5 seconds. 630 is snap to each color every 10 seconds. 640 is snap to each color every 60 seconds. 650 is snap to each color every 5 minutes. 701 is lock 1st position on color wheel. 702 is lock 2nd. position on color wheel. 703 is lock 3rd. position on color wheel. 704 is lock 4th. position on color wheel. 705 is lock 5th. position on color wheel. 706 is lock 6th. position on color wheel. 707 is lock 7th. position on color wheel. 708 is lock 8th. position on color wheel. Synchronizing Multiple Illuminators This feature allows the user to "daisy chain " multiple illuminators and synchronizes the color. Using standard DMX cable, it is possible to plug two or more illuminators together and designate one illuminator as the "master". The other illuminators on the chain will then be "slaved" to its commands. 1. Link two or more illuminators using DMX cable 2. Designate a "master" illuminator. Any illuminator in the "daisy chain" can be designated master illuminator. After the master illuminator is chosen, set Adjustment Knobs on that uit on desired stand alone program to enable the master mode. 3. To designate a "slave" unit, set that unit s Adjustment Knobs to 001. Resetting the DMX Programs Set Adjustment Knobs to 000. Unit will reset to first position color (white on standard wheel)

Trouble Shooting Light is very dim: 1. Remove master ferrule and check if fiber is discolored or burned from excessive heat. 2. Check all glass between lamp and port for dirt and debris. 3. Check lamp and reflector for dirt and debris. 4. Replace lamp. (Contact your Advanced Lighting Systems dealer for replacement lamp). 5. Check outlet voltage. Lamp does not come on: 1. Check to see if unit is plugged in. 2. Check to see if outlet has power. 3. Check fuse. 4. Check lamp connection. 5. Check to see if fan comes on. 6. Be sure lid is correctly in place and activating safety cut out switch. Lamp operation is intermittently on and off: 1. Check connections. 2. Check fan. DMX unit color wheel operation is random or not operating: 1. See DMX table for rotary knob settings. LyteLaunch 150 Re-Order Parts List Item Part # LyteLaunch 150 Dry Location 120V ALS-LL150-D-120- LyteLaunch 150 Dry Location 240V ALS-LL150-D-240- LyteLaunch 150 Wet Location 120V ALS-LL150-W-120- LyteLaunch 150 Dry Location 240V ALS-LL150-W-240- LyteLaunch 150 with Standard Color Wheel Add to above specification - S8 LyteLaunch 150 with Custom Color Wheel Add to above specification ˆ C8 LyteLaunch 150 with White Light Only Add to above specification ˆ WL LyteLaunch 150 with DMX control Add to above specifications - DMX Lamp for LyteLaunch 150 CDM-SA/R 150 Ferrule Assembly for LyteLaunch 150 LL150 MF Fuse for LyteLaunch 150 LL150 Fuse 10 Amp