C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

Similar documents
C60H-DC C curve. Catalogue numbers

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

ic60a circuit breakers (curve C)

Influence of ambient temperature

Safe and reliable photovoltaic energy generation

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

DPX moulded case circuit breakers

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Railway application. Technical guide. Final distribution applications 05/2013

Circuit protection and control devices 0.5 to 6300 A

Phase + Neutral, neutral on right side

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Phase + Neutral, neutral on left side

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DPX 1600 Electronic release

DX³ 4-pole RCBO 6000 A/10 ka

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps

cor Long Run Experience

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

DPX 630 Electronic release

DX³ RCCBs - ID 4P up to 100 A

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

RX 3 M.C.B A up to 63 A

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

DX³ RCBO 6000 A Phase + Neutral, neutral right side

TX³ RCCBs 2P up to 100 A

(1,5 modules per pole)

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

RX 3 M.C.B A up to 63 A

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

MCBs and RCDs LR TM 6000

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

CPG.0 Single busbar gas-insulated cubicles

Domae. The right solution for distribution boards

Compact NR630. NR100F to NR630F

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

DX³ RCBO 6000A Phase + Neutral, neutral on left

Acti 9 the efficiency you deserve

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Btdin RCBO 6000A up to 63A (2P)

and other modular devices for low voltage installation

Cascading & Discrimination

Wall mounted switchgear


DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DPX earth leakage DPX 3 -I earth leakage

3 - Protection components Motor circuit-breakers

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

up to 63 A (1 module per pole)

AF40... AF96 3-pole contactors Technical data

Vistop TM isolating switches 63 to 160A

An innovative technology

New DX 3 High rating & breaking capacity

R.C.B.O. SP / 1 module

BETA Switching Switches and Light Indicators

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

Modular contactor for installation into distribution boards

Breaking and protection devices

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Cylindrical fuse-link

Solar Installer Range. Bright solutions

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

DC-Switch Disconnectors for Photovoltaic acc. to IEC

DPX Magnetic only

Electronic circuit breaker EBU10-T

Power protection solutions

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

Mini DC - Isolators for Photovoltaic

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

The effective choice The benefits of a product with the highest quality standards

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DX³ RCBO 6000A Phase + Neutral, neutral on right

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

COMPLETE SOLUTIONS FOR POWER PROTECTION

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Transcription:

DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewable energy...). They combine the following functions of circuit protection against short-circuit and overload currents, control and isolation. e Direct current (DC) Breaking capacity (Icu) according to IEC 60947-2 Type Rated service breaking capacity (Ics) 1P 110 V 220 V 250 V 440 V 500 V Rating 0.5 to 63 A 20 ka 10 ka 6 ka - - 75 % Icu (In) 2P (in series) 110 V 220 V 250 V 440 V 500 V 0.5 to 63 A - 20 ka 20 ka 10 ka 6 ka 75 % Icu Catalogue numbers C60H-DC Type 1P 2P DB116588 DB124110 DB124111 Auxiliaries Supply from above or below, observing the polarity Supply from above Remote signalisation and tripping, module CA907008 Supply from below Rating (In) Curve C Curve C 0.5 A A9N61500 A9N61520 1 A A9N61501 A9N61521 2 A A9N61502 A9N61522 3 A A9N61503 A9N61523 4 A A9N61504 A9N61524 5 A A9N61505 A9N61525 6 A A9N61506 A9N61526 10 A A9N61508 A9N61528 13 A A9N61509 A9N61529 15 A A9N61510 A9N61530 16 A A9N61511 A9N61531 20 A A9N61512 A9N61532 25 A A9N61513 A9N61533 30 A A9N61514 A9N61534 32 A A9N61515 A9N61535 40 A A9N61517 A9N61537 50 A A9N61518 A9N61538 63 A A9N61519 A9N61539 Number of modules of 9 mm 2 4 Accessories Modules CA907013 and CA907012 CA901024E Version : 1.6 19/05/2015 111

DC circuit supplementary protectors for feeders / distribution systems C60H-DC (cont.) C curve Connection Without accessory With accessories DB123537 14 mm 6.5 mm Rating Tightening torque Copper cables Rigid / Stranded Flexible or with ferrule 50 mm² Al Screw-on connection for terminal terminal ring terminal Multi-cables Rigid cables Flexible cables O-OFF O-OFF PZ2 y 25 A 2.5 N.m 1 to 25 mm 2 1 to 16 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 > 25 A 3.5 N.m 1 to 35 mm 2 1 to 25 mm 2 - DB123537 Multi-cables connection 14 mm 6.5 mm Rating Tightening torque Without accessory 2 Copper cables 3 Multi-cables / Different wires Rigid / Stranded Flexible or with ferrule Flexible / Stranded Flexible / Stranded / Rigid DB122945 DB122946 DB118787 DB122945 DB122946 DB122935 DB118789 DB118787 O-OFF O-OFF PZ2 y 25 A 2.5 N.m 2 x 1 mm 2 to 2 x 10 mm 2 3 x 1 mm 2 2 x 2.5 mm 2 + 1 x 1.5 mm 2 > 25 A 3.5 N.m 2 x 1 mm 2 to 2 x 16 mm 2 3 x 4 mm 2 2 x 10 mm 2 + 1 x 6 mm 2 DB123310 Technical data b Tripping curves: C curve - Overcurrent protection for any type of application. b Positive break indication - the green strip indicates that all the poles are open and allows work to be carried out on the downstream circuit in complete safety. b b Increase in the service life of the product: thanks to fast closure independent of the speed of action on the handle. b Current limitation in the event of a fault: fast opening of the contacts prevents the loads from being destroyed in the event of a short-circuit. PB124305.eps DB123312 DB123391 IP40 Main characteristics According to IEC 60947-2 Insulation voltage (Ui) 500 V DC Rated voltage (Un) 1P 250 V DC 2P 500 V DC Operating voltage (Ue) 1P 24...250 V DC 2P Pollution degree 3 Rated impulse withstand voltage (Uimp) under frame 24...500 V DC Magnetic tripping (Ii) 8.5 In (± 20 %) (compatible with curve C) Additional characteristics Degree of protection Device in modular IP40 (IEC 60529) enclosure Utilization category A (no delay in accordance with IEC 60947-2 standards) 6 kv Endurance (O-C) Electrical 3,000 cycles (where L/R=2 ms) Mechanical 6,000 cycles where the circuit is resistive 20,000 cycles Tropicalization (IEC 60068-2) Treatment 2 (relative humidity 95 % at 55 C Operating temperature -25 C to 70 C Storage temperature -40 C to 85 C d Failure to match polarity during connection may lead to a fire hazard and/or serious injury. b The connection polarity must be observed (marked on the front panel). b Use only with direct current. 112 Version : 1.6 19/05/2015 CA901024E

DC circuit supplementary protectors for feeders / distribution systems C60H-DC (cont.) C curve Weight (g) Circuit-breaker Type 1P 2P C60H-DC 128 g 256 g Dimensions (mm) DB124113 DB124112 t 35 10 10 t t 35 Details of minimum distance between circuit-breaker and earthed metal parts for circuit-breaker intended for use without enclosure. CA901024E Version : 1.6 19/05/2015 113

DC circuit supplementary protectors for photovoltaic installations PB108403-50 The is a DC circuit breaker dedicated to multi string photovoltaic installations. This circuit breaker is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits (see application diagram). Combined with a switch (of the C60NA-DC type, for example), the will be installed in a string PV protection enclosure at the end of each string of photovoltaic modules. It can be locked (by a padlocking device) in OFF position as a safety measure for removal of the PV inverter. can detect and protect against any bidirectional current. To ensure the safety of the installation, it is necessary, depending on the various types of application, to combine the with: b a residual current device at the AC end, b a fault passage detector (insulation monitoring device) at the DC end b an earth protection circuit breaker at the DC end (see Practical Advice CA908035). In all cases, fast action on site will be required to clear the fault (protection not ensured in the event of a double fault). is not polarity sensitive: (+) and (-) wires can inversed without any risk. The is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. IEC / EN 60947-2 e DB404840 Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) 1.5 ka Impulse voltage (Uimp) 6 kv Electrical connection By the bottom for In and Out Number of poles 2P Number of modules of 9 mm 8 Diagrams DB122506 DB122703 IN IN OUT OUT 1 3 2 4 IN OUT 1 3 2 4 1 3 2 4 Standards IEC 60947-2 EN 60947-2 Rating (A) Catalogue numbers 1 A9N61653 2 A9N61654 3 A9N61655 5 A9N61656 8 A9N61657 10 A9N61650 13 A9N61658 15 A9N61659 16 A9N61651 20 A9N61652 25 A9N61660 Auxiliaries See modules CA907008 and CA907013 114 Version : 1.4 19/05/2015 CA901031E

DC circuit supplementary protectors for photovoltaic installations (cont.) Application diagram DB404621 String PV protection enclosure Photovoltaic string modules PV Inverter protection enclosure PV Inverter C60NA-DC* iprd 40r PV C60NA-DC* iprd 40r PV PV Inverter protection enclosure PV Inverter iprd 40r PV C60NA-DC* iprd 40r PV MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF *C60NA-DC: 20 A/1000 V DC or 32 A/800 V DC or 50 A/700 V DC CA901031E Version : 1.4 19/05/2015 115

DC circuit supplementary protectors for photovoltaic installations (cont.) Technical data b Position contact indication - suitability for isolation according to IEC/EN 60947-2 standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Pre-wired product: Input / Output on the same side. Main characteristics Rated service breaking capacity (Ics) 100 % of the Icu Endurance (O-C) Electrical 1,500 cycles (where L/R=2 ms) Mechanical 20,000 cycles Mechanical Degree of pollution 2 Category Degree of protection (IEC 60529) Tropicalisation Device in modular enclosure 20,000 cycles A (no delay in accordance with IEC / EN 60947-2 standards) IP40 Temperature Operating -25 C to 70 C Storage -40 C to 85 C Relative humidity: 95 % at 55 C in accordance with IEC 60068-2 and GB 14048.2 standards Additional characteristics Rating (A) Voltage drop (mv) Power loss (W) 1 9200 9200 9.2 2 5104 2552 10.2 3 2980 993.3 8.9 5 2000 400 10 8 1384 173 11.1 10 680 68 6.8 13 572 44 7.4 15 600 40 9 16 648 40.5 10.4 20 588 29.4 11.8 25 488 19.5 12.2 Derating table (A) Ambient temperature ( C) Rating -30-25 -20-15 -10-5 0 +5 +10 +15 +20 +25 +30 +35 +40 +45 +50 +55 +60 +65 +70 1 A 1.18 1.17 1.15 1.14 1.12 1.1 1.09 1.07 1.05 1.04 1.02 1 0.98 0.96 0.94 0.92 0.9 0.88 0.86 0.84 0.82 2 A 2.54 2.5 2.45 2.41 2.36 2.31 2.26 2.21 2.16 2.11 2.06 2 1.94 1.88 1.82 1.76 1.7 1.63 1.56 1.48 1.41 3 A 3.78 3.71 3.65 3.58 3.51 3.45 3.38 3.3 3.23 3.16 3.08 3 2.92 2.84 2.75 2.66 2.57 2.48 2.38 2.27 2.17 5 A 6 5.92 5.83 5.74 5.66 5.57 5.48 5.39 5.29 5.2 5.1 5 4.9 4.8 4.69 4.58 4.47 4.36 4.24 4.12 4 8 A 9.64 9.5 9.36 9.22 9.08 8.93 8.78 8.63 8.48 8.32 8.16 8 7.83 7.67 7.49 7.31 7.13 6.95 6.76 6.56 6.36 10 A 12.6 12.4 12.2 11.9 11.7 11.5 11.2 11 10.8 10.5 10.3 10 9.7 9.4 9.2 8.9 8.6 8.2 7.9 7.6 7.2 13 A 15.5 15.3 15.1 14.8 14.6 14.4 14.2 14 13.7 13.5 13.2 13 12.7 12.5 12.2 12 11.7 11.4 11.1 10.8 10.5 15 A 18.6 18.3 18 17.7 17.4 17.1 16.7 16.4 16.1 15.7 15.4 15 14.6 14.3 13.9 13.5 13.0 12.6 12.2 11.7 11.2 16 A 19.4 19.1 18.9 18.6 18.3 18.0 17.6 17.3 17.0 16.7 16.3 16 15.7 15.3 14.9 14.6 14.2 13.8 13.4 13.0 12.5 20 A 24.1 23.7 23.4 23.0 22.7 22.3 21.9 21.6 21.2 20.8 20.4 20 19.6 19.2 18.7 18.3 17.9 17.4 16.9 16.4 15.9 25 A 30.4 29.9 29.5 29.0 28.5 28.1 27.6 27.1 26.6 26.1 25.5 25 24.5 23.9 23.3 22.7 22.1 21.5 20.9 20.2 19.6 116 Version : 1.4 19/05/2015 CA901031E

DC circuit supplementary protectors for photovoltaic installations (cont.) Technical data (cont.) Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the protective devices to provide greater insulation of the terminal screws b a spacer clips 9 mm in each side to provide isolation. DB404478 DB404479 DB404480 d Required to have a 9 mm space isolation in each side" 9 mm mini 9 mm mini Weight (g) Circuit breaker Type 545 DB405613 Dimensions (mm) Connection Without accessory With accessories DB122701 Rating Tightening torque Copper cables UL 486A 50 mm 2 Cu/Al Terminal Ring tongue terminal screw connection Rigids Flexibles with ferrule PZ2 14 mm 6.5 mm DB112804 DB112805 DB118755 DB118756 y 25 A 2.5 N.m 1 to 25 mm 2 1 to 16 mm 2 50 mm 2 Ø 5 mm CA901031E Version : 1.4 19/05/2015 117

DC main switch for photovoltaic installations C60NA-DC PB108404-50 The C60NA-DC is a direct current switch-disconnector dedicated to disconnection of the string of photovoltaic modules and the PV inverter. It is designed to isolate the string of photovoltaic modules and the inverter from the rest of the photovoltaic installation for maintenance operations in complete safety. Combined with a circuit breaker (of the type, for example), the C60NA-DC will be installed in a string PV protection enclosure close to the strings of photovoltaic modules. It can also be installed near the PV inverter. It can be locked (by a padlocking device) in OFF position to ensure safety during maintenance operations. the C60NA-DC can switch a multi-directional current. C60NA-DC is not polarity sensitive: (+) and (-) wires can inversed without any risk. The C60NA-DC is delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. IEC / EN 60947-3 e DB404841 Main characteristics Operating voltage (Ue) Rated insulation voltage (Ui) Rated operational current (Ie) Impulse voltage (Uimp) Permissible rated short-time withstand current (Icw) Rated short-circuit closing current (Icm) Electrical connection Number of poles Number of modules of 9 mm 8 Diagrams DB122506 20 A: 1000 V CC 32 A: 800 V CC 50 A: 700 V CC 1,000 V DC 50 A 6 kv 600 A 1 ka By the top for In and Out 2P 1 3 2 4 1 3 2 4 DB122704 1 3 2 4 IN OUT IN IN OUT OUT Standards IEC 60947-3 EN 60947-3 Catalogue number Auxiliaries A9N61690 See modules CA907008 and CA907013 118 Version : 1.4 19/05/2015 CA901032E

DC main switch for photovoltaic installations C60NA-DC (cont.) Application diagram DB404622 String PV protection enclosure Photovoltaic string modules Diagram with C60NA-DC for current y 20 A PV Inverter protection enclosure PV Inverter C60NA-DC* iprd 40r PV C60NA-DC* iprd 40r PV Diagram with SW60-DC for current between 20 and 50 A PV Inverter protection enclosure PV Inverter iprd 40r PV C60NA-DC* iprd 40r PV *C60NA-DC: 20 A/1000 V DC or 32 A/800 V DC or 50 A/700 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD24 CA901032E Version : 1.4 19/05/2015 119

DC main switch for photovoltaic installations C60NA-DC (cont.) Technical data b Position contact indication - suitability for isolation according to IEC/EN 60947-3 standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Pre-wired product: Input / Output on the same side. Endurance (O-C) Electrical 300 cycles Mechanical Degree of pollution 2 Category Degree of protection (IEC 60529) Tropicalisation Device in modular enclosure 20,000 cycles DC21B IP40 Temperature Operating -25 C to 70 C Storage -40 C to 85 C Relative humidity: 95 % at 55 C in accordance with IEC 60068-2 and GB 14048.2 standards Derating table (A) C60NA-DC Ambient temperature ( C) Rating +5 +10 +15 +20 +25 +30 +35 +40 +45 +50 +60 +70 50 A 63 61 60 58 56 54 52 50 48 46 41 35 Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the C60NA-DC protective devices to provide greater insulation of the terminal screws b a Spacer clips 9 mm in each side to provide isolation. DB122714 DB122713 DB122715 9 mm mini 9 mm mini d Required to have a 9 mm space isolation in each side" 120 Version : 1.4 19/05/2015 CA901032E

DC main switch for photovoltaic installations C60NA-DC (cont.) Technical data (cont.) Weight (g) Switch disconnector Type C60NA-DC 530 DB122712 Dimensions (mm) DB122701 Connection Without accessory With accessories 14 mm PZ2 6.5 mm Rating Tightening torque Copper cables UL 486A Rigids Flexibles with ferrule 50 mm 2 Cu/Al Terminal Screw on connection for ring terminal Multi-cables terminal Rigid cables Flexible cables DB112804 DB112805 DB118755 DB118756 DB118757 50 A 3.5 N.m 1 to 35 mm 2 1 to 25 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 CA901032E Version : 1.4 19/05/2015 121

DC main switch for photovoltaic installations Switch SW60-DC PB108406-50 The SW60-DC is a direct current switch-disconnector dedicated to disconnection of the string of photovoltaic modules and the PV inverter. It is designed to isolate the inverter from the rest of the photovoltaic installation for maintenance operations in complete safety. Combined with a circuit breaker (of the type, for example) and a switch (of the C60NA-DC type, for example), the SW60-DC will be installed in the string PV protection enclosure close to the PV inverter (see application diagram). It can be locked (by a padlocking device) in OFF position to ensure safety when removing the PV inverter. SW60-DC is polarity sensitive: (+) and (-) has to be respected for connection. The SW60-DC is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. IEC / EN 60947-3 e DB404842 General technical data Operating voltage (Ue) Rated insulation voltage (Ui) Rated operational current (Ie) Impulse voltage (Uimp) Permissible rated short-time withstand current (Icw) Rated short-circuit closing current (Icm) Electrical connection Number of poles Number of modules of 9 mm 8 Diagrams DB122699 1000 V DC 1000 V DC 50 A 6 kv 600 A 1 ka By the top for In and Out 2P DB122700 1 2 + 4 + 3 IN OUT OUT IN 1 2 4 3 1 2 4 3 IN OUT OUT IN Standards IEC 60947-3 EN 60947-3 Catalogue number A9N61699 122 Version : 1.2 19/05/2015 CA901030E

DC main switch for photovoltaic installations Switch SW60-DC (cont.) Applications DB404639 String PV protection enclosure Photovoltaic string modules Diagram with SW60-DC for current between 20 and 50 A C60NA-DC* iprd 40r PV PV Inverter protection enclosure PV Inverter iprd 40r PV C60NA-DC* iprd 40r PV *C60NA-DC: 20 A/1000 V DC or 32 A/800 V DC or 50 A/700 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD24 CA901030E Version : 1.2 19/05/2015 123

DC main switch for photovoltaic installations Switch SW60-DC (cont.) Technical data Main characteristics b Position contact indication - suitability for isolation according to IEC/EN 60947-3 standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Pre-wired product: Input / Output on the same side. Endurance (O-C) Electrical 1,500 cycles Mechanical Degree of pollution 2 Category Degree of protection (IEC 60529) Tropicalisation Device in modular enclosure 20,000 cycles DC21A IP40 Temperature Operating -25 C to 70 C Storage -40 C to 85 C Rating adjustment 40 C Relative humidity: 95 % at 55 C in accordance with IEC 60068-2 and GB 14048.2 standards Additional characteristics Rating (A) Voltage drop (mv) Power loss (W) 50 A 251 5.02 12.54 Derating table (A) SW60PV-DC Ambient temperature ( C) Rating +5 +10 +15 +20 +25 +30 +35 +40 +45 +50 +60 +70 50 A 63 61 60 58 56 54 52 50 48 46 41 35 Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the SW60-DC protective devices to provide greater insulation of the terminal screws. b a Spacer clips 9 mm in each side to provide isolation. DB122722 DB122723 DB122724 d 9 mm spacers must be used on both sides of the device to create a local ventilation space around the product. 9 mm mini 9 mm mini d Failure to match polarity during connection may lead to a fire hazard and/or serious injury. The connection polarity must be observed (marked on the front panel). Use only with direct current. 124 Version : 1.2 19/05/2015 CA901030E

DC main switch for photovoltaic installations Switch SW60-DC (cont.) Technical data (cont.) Weight (g) Switch disconnector Type SW60-DC 530 Dimensions (mm) DB123703 Connection Without accessory With accessories 14 mm PZ2 6.5 mm Rating Tightening torque Copper cables UL 486A Rigids Flexibles with ferrule 50 mm 2 Cu/Al Terminal screw on connection for ring terminal Multi-cables terminal Rigid cables Flexible cables DB112804 DB112805 DB118755 DB118756 DB123702 DB118757 50 A 3.5 N.m 1 to 35 mm 2 1 to 25 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 CA901030E Version : 1.2 19/05/2015 125

DC main switch for photovoltaic installations e IEC / EN 60947-3 PB113148-50 The is a direct current switch-disconnector dedicated to disconnection of the string of photovoltaic modules and the PV inverter. It is designed to isolate the string of photovoltaic modules and the inverter from the rest of the photovoltaic installation for maintenance operations in complete safety. The will be installed in a string PV protection enclosure close to the strings of photovoltaic modules. It can also be installed near the PV inverter. It can be locked (by a padlocking device) in OFF position to ensure safety during maintenance operations. the can switch a multi-directional current. Connection b The is not polarity sensitive: (+) and (-) wires can inversed without any risk. Isolation distance b The is delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors Prewired b The cables crosssection is suitable b The tightening torque is mastered 126 Version : 1.1 19/05/2015 CA901043E

DC main switch for photovoltaic installations (cont.) Main characteristics Operating voltage (Ue) Rated insulation voltage (Ui) Rated operational current (Ie) Impulse voltage (Uimp) Permissible rated short-time withstand current (Icw) Rated short-circuit closing current (Icm) Electrical connection Number of poles 1000 V DC 1000 V DC 100 A 6 kv 1.5 ka / 500 ms 1 ka By the top for In and Out 2P Number of modules of 9 mm 12 Diagrams DB122506 1 3 2 4 1 3 2 4 DB122704 1 3 2 4 IN OUT IN IN OUT OUT Standards IEC 60947-3 EN 60947-3 Catalogue number Auxiliaries A9N61701 See modules CA907008 and CA907013 Additional technical data b Position contact indication - suitability for isolation according to IEC/EN 60947-3 standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Prewired product: Input / Output on the same side. Derating table (A) Endurance (O-C) Electrical 300 cycles Mechanical Degree of pollution 2 Category Tropicalisation Ambient temperature ( C) 20,000 cycles DC21B Temperature Operating -25 C to 70 C Storage -40 C to 85 C Relative humidity: 95 % at 55 C in accordance with IEC 60068-2 and GB 14048.2 standards Rating +5 +10 +15 +20 +25 +30 +35 +40 +45 +50 +60 +70 100 A 113 111 110 108 106 104 102 100 98 96 91 85 CA901043E Version : 1.1 19/05/2015 127

DC main switch for photovoltaic installations (cont.) DB122701 Upstream connection Without accessory With accessories 15 mm PZ2 6.5 mm Tightening torque DB112845 Copper cables 50 mm 2 Cu/Al Rigids Flexibles Terminal with ferrule DB112846 DB118755 DB118756 Screw on connection for ring terminal DB118757 Multi-cables terminal Rigid cables Flexible cables 3.5 N.m 35 to 50 mm 2 25 to 35 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 Downstream connection Prewired delivered product: Do not remove Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the protective devices to provide greater insulation of the terminal screws b a Spacer clips 9 mm in each side to provide isolation. DB406345 DB406347 A9N27062 A9N27062 9 mm mini 9 mm mini d Required: to have a 9 mm space isolation in each side" Weight (g) Dimensions (mm) Switch disconnector Type 910 DB406348 108 5 74.4 65 49.5 81.4 86 45 138.3 128 Version : 1.1 19/05/2015 CA901043E

DC main switch for photovoltaic installations (cont.) Application diagram String PV protection enclosure DB406328 Photovoltaic string modules Diagram with for current y 100 A PV Inverter protection enclosure PV Inverter * iprd 40r PV * iprd 40r PV *: 100 A/1000 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD24 CA901043E Version : 1.1 19/05/2015 129

Protection Load protection iprd-dc surge arresters Withdrawable surge arresters type 2 for photovoltaic applications e IEC 61643-1 T2 EN 61643-11 Type 2 UTE C 61740-51 T2 pren 50539-11 T2 PB107585-40 iprd-dc direct current surge arresters are designed to protect against overvoltages due to a lightning strike: of the "DC" input to the inverter and of photovoltaic panels. It should be installed in a switchboard inside the building. If the switchboard is located outside, it must be weatherproof. Withdrawable iprd-dc surge arresters allow damaged cartridges to be replaced quickly. They offer remote reporting of the "cartridge must be changed" message. DB124051 Catalogue numbers Internal diagram Imax (ka) Maximum discharge current L+/t L-/t L+/L- L+/t L-/t L+/LiPRD-DC40r 600PV In (ka) Nominal discharge current Up (kv) Protection level U CPV (V) (1) Maximum steady state voltage Width in module of 9 mm Cat. no. 40 15 1.6 1.6 2.8 600 600 840 6 A9L16434 DB124052 iprd-dc40r 1000PV 40 15 3.9 3.9 3.9 1000 1000 1000 6 A9L16436 u PB107586-30 PB107587-30 Replacement cartridges Type Replacement cartridges for Cat. no. C 40-600PV iprd-dc40r 600PV A9L16683 C 40-1000PV iprd-dc40r 1000PV A9L16692 C neutral PV iprd-dc40r 600PV A9L16690 CA903007E Version : 2.2 19/05/2015 313

Protection Load protection iprd-dc surge arresters Withdrawable surge arresters type 2 for photovoltaic applications (cont.) Connection DB124057 14 mm 6.5 mm PZ2 Type Tightening torque Copper cables DB122945 Rigid DB122946 Flexible or with ferrule iprd-dc 2 N.m 2.5 to 25 mm 2 2.5 to 16 mm 2 DB124049 Generator Depending on the distance between the "generator" part and the "conversion" part, it may be necessary to install two surge arresters or more, to ensure protection of each of the two parts. 10 m iprd-dc 1 Generator Conversion iprd-dc 2 10 m iprd-dc 1 Conversion 314 Version : 2.2 19/05/2015 CA903007E

Protection Load protection iprd-dc surge arresters Withdrawable surge arresters type 2 for photovoltaic applications (cont.) DB123310 DB123312 DB123314 IP20 IP40 Technical data Main characteristics Type of network Temps de réponse Short circuit current (I SCPV ) Isolated direct current < 25 ns 30 A Type of surge arresters Type 2 End-of-life indication mode Additional characteristics Circuit opened by integrated thermal disconnector Degree of protection Device only IP20 (IEC 60529) Device in modular IP40 enclosure Chocs IK03 End-of-life indication By the cartridges White Operational Red At end of life By the NO/NC remote indication contact 250 V AC / 0.25 A Operating temperature -25 C to +60 C Storage temperature -40 C to +85 C Tropicalization (IEC 60068-1) Treatment 2 (relative humidity of 95 % at 55 C) Weight (g) Surge arresters Type iprd-dc40r 600PV 400 iprd-dc40r 1000PV 400 Dimensions (mm) DB124050 CA903007E Version : 2.2 19/05/2015 315

Protection Load protection surge arresters Withdrawable surge arresters type 2 for photovoltaic applications e DB123854 UTE C 61740-51 T2 EN 50539-11: 2013 T2 PB110283-40 direct current surge arresters are designed to protect against overvoltages due to a lightning strike: of the "DC" input to the inverter and of photovoltaic panels. It should be installed in a switchboard inside the building. If the switchboard is located outside, it must be weatherproof. Withdrawable surge arresters allow damaged cartridges to be replaced quickly. The surge arrester base can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom They offer remote reporting of the "cartridge must be changed" message. DB124052 Catalogue numbers Internal diagram I Total (ka) Total discharge current iprd 40r 800PV In (ka) Nominal discharge current Up (kv) Protection level L+/t, L-/t, L+/L- U CPV (V) (1) Maximum continuous operating voltage L+/t, L-/t, L+/L- Width in module of 9 mm Cat. no. 40 15 3 800 6 A9L40271 DB124052 iprd 40r 1000PV 40 15 3.9 1000 6 A9L40281 u PB110285-30 Replacement cartridges Type Replacement cartridges for Cat. no. C 40-800PV iprd 40r 800PV A9L40172 C 40-1000PV iprd 40r 1000PV A9L40182 316 Version : 2.1 19/05/2015 CA903009E

Protection Load protection surge arresters Withdrawable surge arresters type 2 for photovoltaic applications (cont.) Connection DB124057 14 mm 6.5 mm PZ2 Type Tightening torque Copper cables DB122945 Rigid DB122946 Flexible or with ferrule 3.5 N.m 2.5 to 25 mm 2 2.5 to 16 mm 2 DB124049 Generator Depending on the distance between the "generator" part and the "conversion" part, it may be necessary to install two surge arresters or more, to ensure protection of each of the two parts. 10 m iprd-dc 1 Generator Conversion iprd-dc 2 10 m iprd-dc 1 Conversion CA903009E Version : 2.1 19/05/2015 317

Protection Load protection surge arresters Withdrawable surge arresters type 2 for photovoltaic applications Application diagram String PV protection enclosure DB406863 Photovoltaic string modules Diagram with for current y 100 A PV Inverter protection enclosure PV Inverter * iprd 40r PV * iprd 40r PV *: 100 A/1000 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD24 318 Version : 2.1 19/05/2015 CA903009E

Protection Load protection surge arresters Withdrawable surge arresters type 2 for photovoltaic applications (cont.) DB123310 DB123312 IP20 IP40 Technical data Main characteristics Type of network Maximum continuous operating voltage (U CPV ) Response time Permanent operating current (Ic) Short circuit current (I SCPV ) iprd 40r 800PV iprd 40r 1000PV Isolated direct current 800 V 1000 V < 25 ns < 1 ma 200 A Type of surge arresters Type 2 Ground residual current I PE (AC) End-of-life indication mode Additional characteristics Degree of protection (IEC 60529) Satisfactory operation indication I PE (DC) Circuit opened by integrated thermal disconnector Device only IP20 Device in modular IP40 enclosure Chocs IK03 By the cartridges White Operational Red Cartridge must be replaced By the NO/NC remote indication contact 250 V AC / 0.25 A Operating temperature -25 C to +60 C Storage temperature -40 C to +85 C Humidity range 5 % to 95 % Standards UTE C 61740-51 T2 EN 50539-11: 2013 T2 Weight (g) Surge arresters Type iprd 40r 800PV 400 iprd 40r 1000PV 400 DB124050 Dimensions (mm) 54 85 45 DB123314 64 69 CA903009E Version : 2.1 19/05/2015 319

Complementary technical information Photovoltaic Examples of installation architectures The examples of photovoltaic installation architectures presented in this document illustrate the use of direct current circuit breakers dedicated to protection of the modules and cables of the PV strings, to protect against overloads and short circuits. To ensure the safety of the photovoltaic installation it is necessary, in the cases described below, to combine the circuit breaker with other protective or fault detection devices on the DC side. Installation from 10 to 100 kw - Ue y 800 V DC In the case of a PV architecture without an earthed polarity on the DC side and with a PV inverter without galvanic isolation, it is necessary to: b protect each string of photovoltaic modules with a installed in the junction box near the PV modules b add a residual current device on the AC side of the PV inverter so that the latter trips as soon as an earth fault occurs on the DC side. Restarting will be possible only after eliminating the fault. DB406329 Earthing systems Inverter Installation at DC end Insulation monitoring device TT TNS IT b b - Without integral transformer Without earthed polarity - Private domain PV PV modules protective modules enclosure DC protective enclosure Inverter AC protective enclosure idpn Vigi 2P Public domain idpn Vigi 2P isw 4P iquick PF 3P+N General control and protection device Production meter Consumption meter idpn Vigi 2P 740 Version : 1.2 19/05/2015 CA908035E

Complementary technical information Photovoltaic (cont.) Examples of installation architectures Installation from 10 to 100 kw - Ue y 800 V DC In the case of a PV architecture without an earthed polarity on the DC side and with a PV inverter or with galvanic isolation, it is necessary to: b protect each string of photovoltaic modules with a installed in the junction box near the PV modules; b occurs. Restarting will be possible only after eliminating the fault. DB406330 Earthing systems Inverter Installation at DC end Insulation monitoring device TT TNS IT b b - With integral transformer Without earthed polarity b Private domain PV PV modules modules protective enclosure DC protective enclosure Inverter AC protective enclosure IMD IM20 ic60n 2P Public domain IMD IM20 ic60n 2P iid 3P+N 300 ma iquick PRD 3P+N General control and protection device Production meter Consumption meter ic60n 2P IMD IM20 CA908035E Version : 1.2 19/05/2015 741

Complementary technical information Photovoltaic (cont.) Examples of installation architectures Installation from 10 to 100 kw - Ue y 800 V DC In the case of a PV architecture with an earthed polarity on the DC side and with a PV inverter having galvanic isolation, it is necessary to: b protect each string of photovoltaic modules with a installed in the junction box near the PV modules b add a earth protection circuit breaker, with all poles in series, on the DC side of the PV inverter. PV inverter stoppage is actuated via an auxiliary contact combined with the earth protection circuit breaker. Polarity earthing and the protective device should not be implemented if the PV inverter already has an earthed polarity. Restarting will be possible only after eliminating the fault. DB406331 Earthing systems Inverter Installation at DC end Insulation monitoring device TT TNS IT b b - With integral transformer Earthed polarity - Private domain PV PV modules modules protective enclosure DC protective enclosure Inverter AC protective enclosure ic60n 2P Public domain ic60n 2P iid 3P+N 300 ma iquick PRD 3P+N General control and protection device Production meter Consumption meter ic60n 2P + 742 Version : 1.2 19/05/2015 CA908035E

Complementary technical information Photovoltaic (cont.) Examples of installation architectures Installation > 100 kw - Ue y 800 V DC In the case of a PV architecture without an earthed polarity on the DC side and a central PV inverter having galvanic isolation, it is necessary to: b protect each string of photovoltaic modules with a installed in the protection cabinet for the PV strings located near the PV modules b fault and actuate stoppage of the PV inverter as soon as it occurs. Restarting will be possible only after eliminating the fault. DB406332 Earthing systems Inverter Installation at DC end Insulation monitoring device TT TNS IT b b b With integral transformer Without earthed polarity b PV modules PV modules protective enclosure NSX100-200NA DC-PV/ NSX100-200NA DC-PV/ DC protective enclosure NSX80-200DC-PV NSX80-200DC-PV Compact NSX/ Masterpact IMD Inverter XM300 IM20PV AC protective enclosure IMD Compact NSX/ Masterpact (*) IM20 To LV/MV transformer iquick PRD/ iprd40 IT + NG125(*) 3P (*) if IT earthing system at AC end NSX100-200NA DC-PV/ NSX80-200DC-PV NSX100-200NA DC-PV/ NSX80-200DC-PV CA908035E Version : 1.2 19/05/2015 743

Complementary technical information Photovoltaic (cont.) Examples of installation architectures Installations > 100 kw - Ue y 800 V DC In the case of a PV architecture with an earthed polarity on the DC side and a central inverter having galvanic isolation and an IT earthing system on the AC side, it is necessary to: b protect each string of photovoltaic modules with a installed in the protection cabinet for the PV strings located near the PV modules b add a earth protection circuit breaker, with all poles in series, on the DC side of the PV inverter. PV inverter stoppage is actuated via an auxiliary contact combined with the earth protection circuit breaker. Polarity earthing and the protective device should not be implemented if the PV inverter already has an earthed polarity. If the Isc of the DC installation exceeds 1.5 ka, replace the earth protection circuit breaker with an NSX80 DC PV provided with a 16 A release. Restarting will be possible only after eliminating the fault. DB406333 Earthing systems TT TNS IT - - b PV PV modules modules protective enclosure DC protective enclosure NSX80-200DC PV Inverter Installation at DC end Insulation monitoring device Without integral transformer Earthed polarity - NSX100-200NA DC-PV/ NSX100-200NA DC-PV/ NSX80-200DC PV Compact NSX/ Masterpact Inverter 10 A - 800 V AC protective enclosure Compact NSX/ Masterpact iprd40 IT + NG125 3P To LV/MV transformer NSX100-200NA DC-PV/ NSX80-200DC PV + NSX100-200NA DC-PV/ NSX80-200DC PV 744 Version : 1.2 19/05/2015 CA908035E

Complementary technical information Examples of using switch-disconnector Architectures 10 kw-100 kw grid-connected PV system (small buildings) Three-phase multi-input inverter without array box Typically, 10 kw to 36 kw grid-connected inverters with U OC MAX probably higher than 600 V (i.e. 800 V or 1000 V) and I SCTC < 125 A, I AC < 63 A. In this range of power, inverters usually have between 2 and 4 maximum power point tracking (MPPT) inputs, so the number of strings in the same DC sub-network is equal to one or two. There is no need for string protection. A PV main switch for each MPPT input is necessary. When an inverter is indoors, additional remote-controlled switches at DC cable entry point are recommended for emergency services. Q1 DB406341 SPD Q2 SPD Inverter with or without galvanic isolation ic60 Vigi type B or SI To grid connection SPD Q1 Q2 Outdoor Indoor Needs String junction box Switchgears and control PV main switch Isolation (b) Switching (making and breaking rated current) DC21B (b) DC21B Control (a) (b) Schneider Electric offer "Q1" C60NA-DC + MX / MN or + MX / MN "Q2" INS PV or C60NA-DC or b v v CA908040E Version : 1.0 19/05/2015 745

Complementary technical information Examples of using switch-disconnector Architectures (cont.) 10 kw-100 kw grid-connected PV system (small buildings) Three-phase inverter with one array box Typically, 30 kw to 60 kw grid-connected inverters. U OC MAX is generally higher than 600 V (up to 1000 V), I SCTC does not exceed 200 A, I AC does not exceed 100 A. This design has more than 2 strings. Reverse current protection is therefore necessary. A main PV switch is required. When an inverter is inside, additional remote-controlled switches at DC cable entry point are recommended for emergencies. DB406342 Q1 SPD Q2 SPD Inverter with or without galvanic isolation ic60 Vigi type B or SI SPD To grid connection Outdoor Indoor Needs String / Array junction box Switchgears and control PV array main switch Isolation (b) Switching (Making & breaking rated current) DC21B (b) DC21B Control (a) (b) Schneider Electric offer "Q0" TeSys DF "Q1" Compact NSX DC PV + MX / MN or + MX / MN "Q2" Compact NSX DC PV or b v v 746 Version : 1.0 19/05/2015 CA908040E

Complementary technical information Examples of using switch-disconnector Architectures (cont.) 10 kw-100 kw grid-connected PV system (small buildings) Three-phase inverter with two array boxes Typically, 60 kw to 100 kw grid-connected inverters with 2 arrays. Array cable protection is not necessary for 2 or 3 arrays. The I SCTC array y 200 A, I SCTC y 400 A, and I AC MAX y 200 A. A PV main switch is required close to the inverter. Remotely operated switches in array boxes allow disconnects to be located close to the PV modules in the event of emergencies. SPD DB406343 Q1 Q1 Q2 SPD Inverter with or without galvanic isolation ic60 Vigi type B or SI SPD To grid connection Outdoor Indoor Needs String Array junction box Switchgears and control PV generator main switch Isolation (b) Switching (making and breaking rated current) DC22A (b) DC22A Control (a) (b) Schneider Electric offer "Q0" TeSys DF "Q1" "Q2" Compact NSX NA DC PV or or C60NA-DC or Compact NSX NA DC PV b v v CA908040E Version : 1.0 19/05/2015 747

Complementary technical information Examples of using switch-disconnector Architectures (cont.) 150 kw-500 kw grid-connected PV system (large buildings and farms) Multi three-phase inverter design without array box Typically, 10 x 20 to 20 x 30 kw grid-connected inverters. U OC MAX y 1000 V. One or two string per inverter. I AC MAX 50 A for one inverter. DB406344 Q1 SPD Inverter with or without galvanic isolation ic60 Vigi type B or SI Compact NSX To grid connection SPD Q1 SPD Q1 Q1 Outoor Indoor String / Array junction box Needs Schneider Electric offer Switchgears and control "Q1" C60NA-DC or or SW60DC See 10 to 36 kw design Compact NSX with Micrologic trip unit ensures full selectivity with ic60 up to 40 A and offer advanced measurement and communication capabilities. 748 Version : 1.0 19/05/2015 CA908040E