Series MNK-X, MNK-XB, SCK-X Frame-mounted Chemical Vortex Pumps

Similar documents
SUPPLEMENTARY INSTALLATION AND OPERATING MANUAL Translation of the original manual. Series MNK-X, MNK-XB, SCK-X Frame-mounted Chemical Vortex Pumps

INSTALLATION AND OPERATING MANUAL Translation of the original manual. Series SCK. Mechanical Seal. double, to DIN EN Keep for future use!

Series MNK-B Sealless Chemical Magnetic Drive Pump Close-coupled design Size

Series MNK-B Sealless Chemical Magnetic Drive Pump Close-coupled design Size

Mechanical seals external, single or double type Crane 58U 58U

Sealless Chemical Magnetic Drive Pump Bearing lubrication: Grease and oil bath Bearing pedestal group: 1+2

Mechanical seals external, single or double type Crane 58U 58U

Sealless Chemical Magnetic Drive Pump Close-coupled design

Sealless Chemical Magnetic Drive Pump Close-coupled design from size

Chemical Process Pump for Mechanical Seals Bearing lubrication: Long life grease or oil bath Bearing pedestal group: 1

Peripheral Pumps with Magnetic Drive Close-coupled design size

Sealless Chemical Magnetic Drive Pump Bearing lubrication: Long life grease, grease or oil bath Bearing pedestal group: 4

Sealless Chemical Magnetic Drive Pump Close-coupled design

Sealless Chemical Magnetic Drive Pump Close-coupled design

Sealless Chemical Magnetic Drive Pump acc. to ASME Bearing lubrication: Long life grease and oil bath Bearing pedestal group: 1 and 2

Sealless Chemical Magnetic Drive Pump Close-coupled design

Richter Sealless Chemical Magnetic Drive Pumps

Richter Sampling Valves

Richter Sampling Valves

Richter Sampling Valves

Richter Sampling Valves

PRODUCT INFORMATION. Single-stage magnetically coupled pumps according to EN 22858; ISO 2858; ISO Model series MCN

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

DATA SHEET TB 26l. BR 26l, BR 26t, BR 26v, BR 26x Multi-port ball valve Ball valve in horizontal and vertical version. Application

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

Richter Ball Control Valves Torque transmission free of play

Volute Casing Centrifugal Pumps according to EN 22858, ISO 2858 with Magnetic Drive. Series CNH-M

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Richter Ball Control Valves Torque transmission free of play

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

Richter Ball Control Valves Torque transmission free of play

Safety Valves with certification

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Sampling Valves PFA-lining or investment cast stainless steel

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Operating Instructions

TSCHAN - TORMAX VSG. Installation and Operation Manual TSCHAN Highly flexible shaft coupling BAWE 009-GBR-0 05/2004

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

HEAVY-DUTY BALL VALVES

PTB GLV. Vertical Centrifugal Pump

Operating Instructions

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Operating and installation instructions

CENTRIFUGAL PUMP TYPE SLM NV TO DIN EN ISO 2858 AND DIN EN ISO 15783

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

Swing Piston Compressors and Vacuum Pumps

Model series CAM / CAM-Tandem

Operating instructions Solenoid interlock EX-AZM About this document. Content

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Instruction Manual. Ex-Time 40 / 50

Norm-Centrifugal Pumps PN 10

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Operating Instruction for Liquid-Ring Vacuum Pumps

Single-stage canned motor pumps complying with the chemical standards according to EN 22858; ISO Series HCN / HCNF Standard design

Rotary feed-through DDF-S/-KS

Micro Diaphragm Gas Sampling Pumps

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

Diaphragm Vacuum Pump

Single-stage centrifugal pumps to standards en 733 (nfe 44111) and iso 5199 Industry Agriculture - Heating

Ex m Solenoid Operator Type 0519

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Chemical Magnetic Pumps with PTFE/PFA lining ATEX- and FDA compliant

Company Standard Mounting Instructions for Type Valves with Type AT Actuator

Pneumatic Rotary Actuator DSO-P. Hydro-Pneumatic Actuator DSO-H

Standard plastic pump with magnetic coupling for use in the chemical industry ISO 2858/DIN EN 22858

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

DIAPHRAGM LIQUID PUMP NF 1.30

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Operating Instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

P R O D U C T I N F O R M A T I O N. Gear pumps. Series LZ / LZM

Type 6213 EV, 6281 EV

Swing Piston Compressors and Vacuum Pumps

Micro Diaphragm Gas Sampling Pumps

Richter PFA/PTFE Shut-off and Control Butterfly Valves

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

DIAPHRAGM LIQUID PUMP NF 2.35

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Neotecha SAPRO Sampling Valve SV for sampling with piston syringes Installation and Maintenance Instructions

Wall-hung boilers Gas-Wandheizgeräte

Oil-free piston compressors KK and piston vacuum pumps KV

SERVO MOTORS BRUSHLESS SERVO MOTORS ATEX ZONE 2-22 OPERATING INSTRUCTIONS 2016

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Swiveling gripper finger GFS 16-40

Level Electrode NRG NRG NRG NRG

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Bowl feeder WV401-1 / Translation of operating and installation instructions

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Bowl Feeder BF10 / BF15 Translation of operating and installation instructions

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Differential Pressure Gauge

CENTRIFUGAL PUMP TYPE SLM NV TO DIN EN AND DIN EN ISO SEALLESS WITH MAGNET DRIVE

HEAVY DUTY HORIZONTAL, SEALLESS CENTRIFUGAL PUMP WITH PERMANENT MAGNET DRIVE SYSTEM, NO MECHANICAL SEAL ISO DIN 24256

Transcription:

SUPPLEMENTARY INSTALLATION AND OPERATING MANUAL Translation of the original manual Series MNK-X, MNK-XB, Frame-mounted Chemical Vortex Pumps Keep for future use! This operating manual must be strictly observed before transport, installation, operation and maintenance Subject to change without notice. Reproduction is generally permitted with indication of the source. Richter Chemie-Technik GmbH Edition 03/2010

Series MNK-X, MNK-XB, Page 2 List of Contents List of Contents... 2 Relevant documents... 2 1 Technical data... 2 1.1 Intended use... 3 1.2 Name plate... 3 2 Safety, transport, storage and disposal... 3 3 Product description... 3 4 Installation... 4 4.1 Safety regulations... 4 5 Commissioning / Shutdown... 4 5.1 Initial commissioning... 4 5.2 Shutdown... 4 5.3 Improper operations and their consequences... 4 6 Maintenance... 4 6.1 Notes on dismantling... 4 7 Sectional drawing... 5 7.1 MNK-X vortex design... 5 7.2 vortex design... 6 Relevant documents This supplementary installation and operating manual is only valid in conjunction with these installation and operating manuals: MNK long life grease and oil bath lubrication 9230-050-en MNK-B close-coupled design 9230-055-en SCK long life grease and oil bath lubrication 9220-050-en Appendix to the operating manual Operational limits 9200-00-3031 1 Technical data Manufacturer : Richter Chemie-Technik GmbH Otto-Schott-Str. 2 D-47906 Kempen Telephone: +49 (0) 2152 146-0 Fax: +49 (0) 2152 146-190 E-Mail: richter-info@idexcorp.com Internet: http://www.richter-ct.com Authorised person acc. to machinery directive 2006/42/EG: Gregor Kleining All technical data can be found in the installation and operating manuals for the relevant pumps MNK, MNK-B or SCK. Designation : Vortex design of single-stage, plastic-lined centrifugal chemical pumps. Series: MNK-X long life grease or oil bath lubrication MNK-XB close-coupled design long life grease or oil bath lubrication Heavy-duty horizontal design Technical specifications to ISO 15783 and DIN ISO 5199 Face to face according to ISO 2858 / DIN EN 22858 Flange connecting dimensions: DIN EN 1092-2, type B (ISO 7005-2, type B) PN 16 or flanges drilled to ASME 16.5, Class 150 ATEX Directive 94/9/EC Machine Directive 2006/42/EC Temperature classes : See installation and operating manual MNK, MNK-B or SCK in Section 2.6.7 Admissible ambient conditions for pumps acc. to directive 94/9/ EG (ATEX) : Ambient temperature range: - 20 C to + 40 C (higher temperature after consulting the manufacturer) Ambient pressure range: 0,8 bar abs to 1,1 bar abs.

Series MNK-X, MNK-XB, Page 3 1.1 Intended use Richter pumps of the series MNK-X, MNK-XB and are plastic-lined centrifugal pumps for the conveyance of aggressive, toxic, pure and inflammable liquids. Vortex pumps are preferably used with highly solidsladen media. Field of application: For media with high solids content, depending on the grain size and condition particle sizes of roughly 10 20 mm, depending on the pump size long-fibre constituents gas contents of up to 5 % by vol. If gas is entrained in an explosive area, it must be ensured that no explosive atmosphere enters the pump as a result of the gas conveyed. In view of the large number of possible particle properties (size, shape, density etc.) it is not possible to delimit the solids accurately in advance. Richter therefore recommends the use of motor load monitors, for example, to monitor the pump power. 1.2 Name plate The stainless steel name plate is firmly riveted to the bearing pedestal. If the customer attaches his identification, it must be ensured that the pump matches the application in question. Example of name plate: 2 Safety, transport, storage and disposal The relevant chapters in the adjacent installation and operating manuals apply to safety, transport, storage and disposal. This Supplementary Installation and Operating Manual is only valid, depending on the selected design, in conjunction with the following installation and operating manuals: MNK long life grease and oil bath lubrication 9230-050-en MNK-B close-coupled design 9230-055-en SCK long life grease and oil bath lubrication 9220-050-en 3 Product description The housing dimensions, power ratings and technical requirements of the pump series MNK-X, MNK-XB and comply with ISO 2858 / DIN EN 22858 / ISO 15783 / DIN ISO 5199. The technical requirements of VDMA 24279 are satisfied. The sectional drawing shows the vortex design. See Section 7. All components which come into contact with the medium are either plastic-lined or made of other resistant materials, e.g. silicon carbide.

Series MNK-X, MNK-XB, Page 4 4 Installation 4.1 Safety regulations Equipment which is operated in potentially explosive areas must satisfy the explosion protection regulations. It is imperative to observe the safety regulations contained in the respective installation and operating manuals. With magnetic drive pumps MNK-X, MNK-XB: People with a pacemaker are at risk from the strong magnetic field of the magnetic drive. It may be life-threatening for them to stay at a distance of less than 500 mm from the pump. 5 Commissioning / Shutdown The general commissioning/shutdown procedures have already been described in the installation and operating manuals of the pumps of the series MNK, MNK-B, SCK. They relate, for example, to work or inspections of the bearing pedestal, coupling and motor. If the pump is to be evacuated or flushed, observe the local regulations. If the pump is to be returned to the company's own workshops or the manufacturer's, it must be cleaned especially thoroughly. See also Section 3.1. 5.1 Initial commissioning Normally, the pumps have already been test-run with water. Unless special agreements have been made, there could still be residual amounts of water in the pump. This must be noted in view of a possible reaction with the medium. 5.2 Shutdown Only close the suction line if the pump is to be evacuated or dismantled. 5.3 Improper operations and their consequences Inadmissible modes of operation, even for a short time, can result in serious damage to the unit. In connection with explosion protection, potential sources of ignition (overheating, electrostatic and induced charges, mechanical and electric sparks) may result from these inadmissible modes of operation; their occurrence can only be prevented by adhering to the intended use. Depending on the design selected, refer to the relevant operating manual MNK, MNK-B or SCK. 6 Maintenance 6.1 Notes on dismantling All repair and maintenance work is to be performed by qualified staff using appropriate tools and original spare parts. Is the necessary documentation available? Has the pump been taken out of operation, evacuated and flushed correctly? See also Section 5.2. The pump is dismantled and assembled in accordance with the operating manual. The difference between a standard pump and a vortex pump is: vortex impeller 230 a distance ring 504/3 instead of a housing gasket longer hex. screws 901/3 owing to the larger distance in front of the impeller.

Series MNK-X, MNK-XB, Page 5 7 Sectional drawing 7.1 MNK-X vortex design

Series MNK-X, MNK-XB, Page 6 7.2 vortex design

CHEMIENORMPUMPEN / CHEMICAL PROCESS PUMPS / POMPE POUR L'INDUSTRIE CHIMIQUE Modification techniques possibles sans réservées! Graphique non à l'échelle! Dimensions valables uniquement revêtues d'une signature! Baureihe/Series/Série Ausführung Magnetkupplungs- und Gleitringdichtungspumpen Design Magnet drive and mechanical seal pumps MNK-X MNK-XB Einsatzgrenzen / operating limits Construction Pompes à entraînement magnétique en à garniture mécanique Baugrößen / Size: 25-25-125, 50-32-125, 50-32-200, 65-40-200, 80-50-200 This leaflet is subject to alteration! Drawing not to scale! Certified for construction purposes only when signed! Technische Änderungen vorbehalten! Nicht maßstäblich! Maße nur mit Unterschrift verbindlich! Einsatzgrenzen der Gleitringdichtung beachten! Observe the operating limits of the mechanical seal! 9200-00-3031/4-01 Richter Chemie-Technik GmbH - 1 -

CHEMIENORMPUMPEN / CHEMICAL PROCESS PUMPS / POMPE POUR L'INDUSTRIE CHIMIQUE Modification techniques possibles sans réservées! Graphique non à l'échelle! Dimensions valables uniquement revêtues d'une signature! Baureihe/Series/Série Ausführung Magnetkupplungs- und Gleitringdichtungspumpen Design Magnet drive and mechanical seal pumps MNK-X MNK-XB Construction Pompes à entraînement magnétique en à garniture mécanique Baugrößen / Size: 25-25-160, 50-32-160, 80-50-160, 125-80-200, 125-100-200, 80-50-250 This leaflet is subject to alteration! Drawing not to scale! Certified for construction purposes only when signed! Technische Änderungen vorbehalten! Nicht maßstäblich! Maße nur mit Unterschrift verbindlich! Einsatzgrenzen der Gleitringdichtung beachten! Observe the operating limits of the mechanical seal! 9200-00-3031/4-01 Richter Chemie-Technik GmbH - 2 -

CHEMIENORMPUMPEN / CHEMICAL PROCESS PUMPS / POMPE POUR L'INDUSTRIE CHIMIQUE Modification techniques possibles sans réservées! Graphique non à l'échelle! Dimensions valables uniquement revêtues d'une signature! Baureihe/Series/Série Ausführung Magnetkupplungs- und Gleitringdichtungspumpen Design Magnet drive and mechanical seal pumps MNK-X MNK-XB Legende: Construction Pompes à entraînement magnétique en à garniture mécanique 1 Standard Bei Einsatz unter ASME-Bedingungen (Sphäroguss nach A395) kann der Standardbereich auf -30 C und 16bar erweitert werden. Legend: Standard Application under ASME-specification (ductile iron acc. to A395) the standard range can be expanded up to -30 C and 16 bar. 2 Höhere Betriebsdrücke durch Druckringe Higher operating pressure by pressure rings 3 Tiefere Temperaturen durch Sondermaterial Lower temperatures by special materials This leaflet is subject to alteration! Drawing not to scale! Certified for construction purposes only when signed! 4 Höheres Vakuum bei Pumpenstillstand durch Sonderspalttopfeinheit Higher vacuum at pump standstill by special can unit 5 Höhere Temperaturen durch CFK-H Spalttopf Higher temperatures by can of CFK-H Technische Änderungen vorbehalten! Nicht maßstäblich! Maße nur mit Unterschrift verbindlich! 9200-00-3031/4-01 Richter Chemie-Technik GmbH - 3 -