INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

Similar documents
INTER PLANT STANDARD STEEL INDUSTRY

INTER PLANT STANDARD STEEL INDUSTRY. SPECIFICATION FOR GENERAL PURPOSE SQUIRREL CAGE INDUCTION MOTORS (Fifth Revision) BASED ON IS 325:1996

INTER PLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR AC CABIN FAN. Corresponding IS does not exist IPSS:

INTER PLANT STANDARDIZATION STEEL INDUSTRY

INTERPLANT STANDARD - STEEL INDUSTRY

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

SPECIFICATION FOR BUTTON HEAD CEASE NIPPLES

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

INTER PLANT STANDARD STEEL INDUSTRY

INTERPLANT STANDARD - STEEL INDUSTRY. SPECIFICATION FOR SINGLE, DOUBLE & TRIPLE SHEAVE PULLEY BLOCKS FOR FIBRE ROPE (Second Revision )

champion series motors

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

INTERPLANT STANDARD STEEL INDUSTRY ACCEPTANCE NORMS FOR CRANE GEAR BOX FOR TWO STAGE HORIZANTAL Corresponding IS does not exist

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

(i) in paragraph 9, for sub-paragraph (i) the following shall be substituted, namely:-

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT

IECEx Certificate of Conformity Annexe

INTERNATIONAL STANDARD

1LG0 Low-voltage Motors

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

Energy Saving Three Phase Motors

DATASHEET FOR INDUCTION MOTOR

SINGLE PHASE TEFC CAGE MOTORS

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

Brake Motors Aluminium Frame Improved Efficiency EFF2

INTER PLANT STANDARD IN STEEL INDUSTRY SPECIFICATION OF HYDRAILIC HOSE ASSEMBLY & END FITTING FOR HYDRAULIC LINES

Aluminium Frame Motors Improved Efficiency EFF2

ABB Oy MV Induction Machines

Low-voltage motors up to 315kW. 1LG0 Low-voltage Motors. Answers for industry.

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

7 The revised IS 8034:2002 and revised STI be implemented w.e.f. 1 Feb 2005.

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

الهيئة السعىدية للمىاصفبت والمقبييس والجىدة Saudi Standards, Metrology and Quality Org (SASO)

IECEx Certificate of Conformity Annexe

SECTION MOTOR REQUIREMENTS for HVAC

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

[ T] THREE-PHASE MOTORS «[32] [33] Three-Phase Motors - Technical Catalogue 1018/10

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

Series E4F E5F

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

LOW VOLTAGE MOTORS. 0.12kW to 1250kW. Crane & Hoist Duty Motors

Guideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

: B3; B5; B14; B34; B35; V1

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

ABB Ltd HV Induction Machines

W22 Brake Motor Three-phase Electric Motor

Catalog Mars Low voltage Brake motors

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

Scope of Supply of 11Kv Induction motor. The motor is being procured for cooling water pump. The scope of supply of motor is as given below:

Low Voltage Induction Motors

MAX-VH. Vertical Hollow Shaft Motors

Three-phase motors for marine use

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

Guideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society

General Purpose Cast Iron Motors

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

DATA SHEET. Three Phase Induction Motor - Squirrel Cage. Customer : Product code : : W22 NEMA Premium Efficiency Three-Phase

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

INTERNATIONAL STANDARD

From 4 to 20 poles ( over contact MM) IP 23. Available up to IP 44 with filters.

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

ADS7 AC Contactor Starters

Technical Specifications

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

MJH. Model. Up to kva. Power. Up to V. Voltages. Frame 400 ± Pole 4, 6, 8. (over contact MM) Cooling IC 01

Asynchronous generators

HCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet

Modifiable TITAN Horizontal Motors Accessories and Modifications

Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Department/Author Customer name Customer ref. Item name

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

UCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

Company name: GSI Created by: SLK Phone: (65) Date: 13/03/2017 Client: Client Number: Contact:

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

UCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT

UCI224E - Winding 06. Technical Data Sheet APPROVED DOCUMENT

UCI274E - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

PI144D - Winding 17. Technical Data Sheet APPROVED DOCUMENT

AC Induction Motors. Installation and operating instructions

UCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT

Permanent-magnet synchronous motors

Transcription:

INTER PLANT STANDARD STEEL INDUSTRY IPSS SPECIFICATION FOR ac ROLLER TABLE MOTORS (Second Revision) Corresponding IS does not exist IPSS:1-03-007-14 Formerly : IPSS:1-03-007-03 0. FOREWORD 0.1 This Inter Plant Standard (second revision) has been prepared by the Standards Committee on Rotating Electrical Machinery, IPSS 1:3 with the active participation of representatives of steel plants, reputed consulting organizations and established manufacturers of ac Roller Table Motors; and was adopted in July, 2014. 0.2 Inter Plant Standards for steel industry primarily aim at achieving rationalization and unification of parts and sub-assemblies used in steel plant equipment and accessories and provide guidance in indenting stores or equipment for existing or new installations by individual steel plants. For exercising effective control on inventories, it is advisable to select fewer number of sizes (or types) from among those mentioned in this standard for the purpose of company standards of individual steel plants. It is not desirable to make deviations in technical requirements. 0.3 This Inter Plant Standard should be read in conjunction with IPSS:1-03-016-14 `Standard information for enquiry and order for electric motors (second revision). 0.4 This second revision has been carried out because of the following : i) Over the years, experience of users in steel plants demanded some modifications in standard. ii) Due to technological upgradation over the years it was felt necessary to review the standard clause by clause and make changes wherever necessary. 1. SCOPE 1.1 This Inter Plant Standard covers the requirements of three phase squirrel cage induction motors (including roller table motors of geared motor design) operating on DOL starting or VVVF source with large rate of switching operations used for roller table drives in rolling mills in the steel plants. Page 1 of 17

1.2 Class of Insulation The ac roller table motors shall have windings of class `H insulation (with enamel coating) unless otherwise specified [see IS 1271:1985 Thermal evaluation and classification of electrical insulation (first revision)]. Temperature rise limited to class B with class F insulation. 1.3 Motor shall be suitable for required no. of switching operations / reversals per hour either with DOL starting or with VVVF operation. 2. SITE CONDITIONS The following shall constitute normal site conditions for the purpose of this standard: 2.1 Ambient Temperature The reference ambient temperature shall be 40 o C. NOTE: For using motors at higher ambient temperature the guidance given in 7.3 shall be followed. 2.2 Relative Humidity The maximum relative humidity shall be 100%. However, maximum ambient temperature and 100% relative humidity may not occur simultaneously. 2.3 Ambient Air Ambient air may contain fair amount of conductive dust. 2.4 Altitude The altitude shall not exceed 1000 m. 2.5 Form and Symmetry of Currents and Voltages of supply These shall conform to 3.2 of IS 325:1996 `Specification for three phase induction motors (fourth revision) except when the motors are fed from static frequency convertors. NOTE : Limits for wave form distortion for operation of motors from static frequency convertors are under consideration. 3. TERMINOLOGY - For the purpose of this standard, the following definition shall apply : 3.1 Acceleration Torque The acceleration value `B is a measure of the amount of acceleration work the motor is capable of doing during one hour. Its value is determined as the product of total inertia (expressed in GD 2 ) to be accelerated and the maximum number of starts per hour of the motor without exceeding the permissible temperature limit. The unit of `B is kgm 2 /h. NOTE 1 : For duty cycles involving electric braking, recommended equivalent number of starts are given below for guidance: Jogging/inching operation is equivalent to 0.25 starts Page 2 of 17

One plug reversal is equivalent to 4 starts. One dc Dynamic braking stop is equivalent to 2 starts. One plug stop is equivalent to 3 starts. NOTE 2 : For computation of the required acceleration value B, a recommended method is given below: B = KZ GD 2, where K = 0.25 for jogging/inching operation. K = 1 for start (from `0' to 0.9 no to 0 rev/min) K = 2 for dynamic braking (from 0.9 no to 0 rev/min) K = 4 for plug reversal (from 0.9 no to 0.9 no rev/min) Z = Required number of operations/hour, GD 2 = Total GD 2 referred to the motor shaft, and no = synchronous speed. 4. TYPE OF ENCLOSURE 4.1 The degree of protection to be provided by the enclosure shall be IP 55 of IS/IEC 60034-5(2000) [IS 4691:1985 is withdrawn] or better as required by the purchaser. 5. METHOD OF COOLING 5.1 The method of cooling used shall be IC 410 in accordance with IS 6362:1995 `Designation of methods of cooling of rotating electrical machines'. For operation between 1 50 Hz, the motor cooling shall be as per IC 416. IC 401 for non ventilated motors, fins if required on the motor body shall be circular. Space heaters to be provided if specified. 6. MOUNTING 6.1 The mounting shall conform to any one of the designations IMB 3 or IMB 5 specified in IS 2253:1974 `Designations for types of construction and mounting arrangement of rotating electrical machines (first revision)'. If specified, hollow shaft extension may be provided according to the drawing provided by the purchaser. 7. RATED VOLTAGE, FREQUENCY AND PERFORMANCE VALUES 7.1 Voltage and Frequency Variation - The motors shall be capable of delivering the rated output with : i) The terminal voltage differing from its rated value by not more than +6%, -10% in general cases but in special cases if desired by the purchaser. Page 3 of 17

ii) iii) The frequency differing from its rated value by not more than +3 in general cases but in special cases if desired by the purchaser, frequency fluctuation of +3%/-6% shall have to be provided, or Any combination of (i) and (ii). In the case of continuous operation at extreme voltage limits, the temperature-rise limits specified in Table-1 of IS 325:1996 shall not exceed by more than 10 o C. Motors, when operated under the extreme conditions of voltage and frequency variation, may not necessarily have their performance in accordance with this standard. 7.1.1 The motor shall be suitable for operating in the frequency range of 5-50 Hz with corresponding voltage variation for obtaining rated torque when used for variable speed application. For motor operation between 1-50 Hz, the motor cooling shall be as per IC 416. Maximum frequency shall be non VVVF and > 75%. 7.1.2 The motor shall be suitable for direct-on-line starting for non-vvvf application. 7.2 Performance Values - The performance values shall be as given in Table-1. 7.3 Correction Factors for Ambient Temperature - The rated acceleration value as specified in Table-1, correspond to the standard ambient temperature of 40 o C. For higher ambient temperature, the following correction factors for acceleration values shall be applied for selection of desired kw rating accordingly: 45 o C - 93% of the rated acceleration value at 40 o C 50 o C - 85% of the rated acceleration value at 40 o C 55 o C - 80% of the rated acceleration value at 40 o C 60 o C - 75% of the rated acceleration value at 40 o C 7.4 The motors shall also be suitable for operation on static frequency convertors. NOTE: Limits for waveform distortion for operation of motors from static frequency convertors are under consideration. 7.5 The motors shall be suitable for type of duty S4, S5, S6 and S7 [IS 12824:1989 is withdrawn]. While the units are driven through VVVF. However for DOL, the detailed number of switching cycles shall be considered to check the capacity of motor and its value. Page 4 of 17

7.6 Stalled Rotor Withstand Time - Motors shall be suitable for a stalled rotor withstand time of 1 to 3 minutes as specified by the purchaser when starting from cold under rated voltage conditions (see NOTE under Table-1). 8. DIMENSIONS 8.1 The basic dimensions of foot-mounted and flange mounted ac roller table motors and their shaft extensions shall correspond to IS 1231:1974 `Dimensions of three-phase foot-mounted induction motors (third revision)' and IS 2223:1983 `Dimension of flange-mounted ac induction motors (first revision)' respectively. 9. SPECIAL CONSTRUCTIONAL FEATURES 9.1 Material of Body - Material of the motor body shall be cast iron grade FG- 260 conforming to IS 210:2009 `Specification for grey iron castings (fourth revision)', or SG iron conforming to IS 1865:1991 `Specification for iron castings with spheroidal or nodular graphite (second revision)' or fabricated steel conforming to IS 2062:2011 `Steel for general structural purposes (superseding IS 226:1975)'. 9.2 For foot-mounted motors with cast iron/sg iron body, the feet shall be integrally cast with the body. 9.3 IC-401 shall be for non-ventilated motors. Fins, if provided on the motor body, shall be circular. 9.4 Separately screwed eyebolts or lifting lugs of suitable sizes shall be provided on the motor for the purpose of lifting. Eyebolts conforming to IS 4190:1984 `Specification for eyebolts with collars' shall be used. 9.5 Shaft Extension - All motors shall have a single shaft extension unless otherwise specified. 9.6 Bearings - All bearings shall have an L10 life of at least 40000 h [IS 3824 (part 1 to 4):1983 are withdrawn] or minimum medium duty (C3) bearing should be provided. The bearings shall be selected so as to take care of the thrust to which the motors are likely to be subjected. The actual thrust value shall be indicated by the user. 9.7 Lubrication of Bearings - Regreasing facility through a grease nipple conforming to IS 4009(Parts 1 & 2):1981 `Specification for grease nipples (first revision)', along with facility for excess grease removal shall be provided for motors of frame sizes 160 and larger and for above160 frame as per suppliers practice. 9.8 Fixing Bolts for End Shields - The minimum size of end shield fixing bolts shall be M8. The bolts shall have hexagonal heads. Page 5 of 17

9.9 Terminals and Terminal Box - Unless otherwise specified, the motor shall be star connected and only 3 terminals of the motor windings shall be brought out in the terminal box. Terminal box shall be as per detailed engineering requirements. Separate auxiliary terminal box for thermistor shall be provided. 9.9.1 The provisions of the terminal box shall be in accordance with clause 5 of IS 1231:1974. It shall be possible to turn the terminal box to any of the four positions at 90 o intervals to permit cable entry from any of these four positions / or at rear end as specified. Separate auxiliary terminal to be provided for thermistor. 9.9.2 Use of space heaters if specified by the purchaser. 9.10 Interchangeability of Parts - The motors of identical rating supplied in a lot by the same supplier shall have the interchangeability in the following parts: a) Rotors, b) End shield, c) Bearing capsules d) Bearing cups e) Self cooling fans. 10. EARTHING 10.1 Two separate earthing terminals of proper size suitable to receive galvanized iron conductor shall be provided on the bottom half of the motor body. In addition to the two outside earthing terminals, provision for one more earthing terminal inside the terminal box is to be kept. Size of earthing terminal shall conform to clause 12.2.2.2 of IS 3043 : 1987 `Code of practice for earthing (first revision). 11. TEMPERATURE-RISE TEST 11.1 The temperature-rise test shall be carried out at full load in accordance with 22 of IS 325:1996 as per class 1.2 by subjecting the motor to the rated acceleration value (B). The permissible limits of temperature-rise shall not exceed the relevant values given in Table-1 of IS 325:1996 as per clause 1.2. 11.2 Temperature Rise Test Under Stalled Rotor Condition The temperature shall be measured by applying rated voltage to the motor with rotor locked. The temperature-rise shall not exceed the permissible value for the relevant insulation class. Page 6 of 17

12. LIMITS OF VIBRATION 12.1 Limits of vibration intensity shall be in accordance with normal class of Table 1 of IS 12075:2008 `Mechanical vibration of rotating electrical machines with shaft heights 56 mm and higher measurement, evaluation and limits of vibration severity (superseding IS 4729:1968) '. NOTE: The manufacturer shall indicate in the test certificate whether the rotor is balanced, with or without the coupling fixing key in the shaft. 13. LIMITS OF NOISE LEVEL 13.1 The noise level shall not exceed the limits specified in IS 12065:1987 `Permissible limits of noise level for rotating electrical machines, if required by the user. 14. TERMINAL MARKING 14.1 Terminals shall be marked in accordance with IS/IEC 60034-8(2002) [IS 4728:1975 is withdrawn]. Identical markings shall be provided both on the leads and the terminal blocks. 15. RATING PLATE 15.1 Rating plate made of stainless steel stating the following particulars shall be fixed on the body of the motor: a) Reference to this interplant standard, i.e. IPSS:1-03-007-14; b) Rated output in kw, c) Name of the manufacturer and trade mark, d) Manufacturer s serial number and frame reference, e) Rated voltage and winding connection of the motor, f) Rated current in A at rated voltage, g) Speed in rev/min at rated output, h) Rated frequency, i) Class of insulation, Page 7 of 17

16. TESTS j) Type of duty, k) Bearing designation, l) Type of enclosure, m) Mass of motor in kg, n) Stalled rotor withstand time, and o) Year of manufacture. NOTE: An additional name plate may be used to indicate the designation of bearings, lubrication details (type, quantity and frequency). 16.1 The tests applicable to the motors covered by this standard shall be in accordance with Table-2. A certificate indicating the routine tests conducted on each motor including thermal withstand capability shall be supplied with the motors. A proforma given in Appendix-A may be used to indicate the results of type tests specified in Table-2. The manufacturer shall supply type test certificate with each order whenever required by the user. The manufacturer will supply the air gap figure. Page 8 of 17

TABLE 2 TESTS ON ac ROLLER TABLE MOTORS SL No. Test Clause Ref. In ISs Classification of Test 1. Measurement of winding resistance at 21.3.1 of Routine and ambient temperature IS 325:1996 type test 2. Insulation resistance test (both before and after the high voltage test) 24 of IS 325:1996 Routine and type test 3. High voltage test 23 of IS 325:1996 Routine and type test 4. No Load Test 21.3.1 of IS 325:1996 Routine and type test 5. Locked rotor test (for breakaway torque and breakaway starting current) 21.3.1 of IS 325:1996 Routine and type test 6. Performance at the lowest and at the highest frequency -- Routine and type test 7. Temperature-rise test (see 11.1) 22 of Type test IS 325:1996 8. Load test at rated voltage (for verification of 21.3.1 of Type test efficiency, power factor and slip as declared by manufacturer) IS 325:1996 9. Speed torque test (pull-up, pull-out and breakaway torque) over the entire range of 10 -- Type test to 75 Hz with an interval of 5 Hz. 10. Over speed test (120% of the speed corresponding to maximum frequency for two minutes) 11. Mechanical inspection a) Dimensional checking (including checking of air gap) b) Dismantle/Inspection/Reassembly c) Balancing of the rotor d) Mass of the motor 12. Stalled rotor withstand time test (for 3 minutes or 10 minutes as specified under rated voltage condition) 13. Test for verification of acceleration value (dynamic constant) of the motor. The acceleration value (in kgm 2 /h) may be verified by subjecting the motor to continuous plug reversals with a pure inertia load coupled to the motor. The rate of plug reversals to be adjusted depending on the acceleration value specified and the inertia of load. The steady state temperature-rise should be within the limits specified for the insulation class. Page 9 of 17 25 of IS 325:1996 Type test -- Type test -- Type test -- Type test

Note: Speed type test shall be for rated load and peak load in case of VFD motors. Break away and pull out torque for DOL motors. Page 10 of 17

TABLE - 1 PERFORMANCE VALUES OF ac ROLLER TABLE MOTORS (Clause 7.1, 7.2, 7.3 and 7.6) Sl. Nearest Synchron- Breakaway Breakaway Acceleration Value (B) in kgm 2 /h at Maximum No. Frame Size ous speed at Torque in Starting 25% 40% 60% 100% GD 2 of as per IS 50 Hz, rpm kgm at Current at CDF CDF CDF CDF Rotor in 415 V, 50 Hz 415 V, 50 Hz kgm 2 1 2 3 4 5 6 7 8 9 10 FOOT MOUNTED MOTORS 1 132 M 1000 2.4 nil 1200 nil nil nil 0.063 2 180 L 750 7 nil 3900 nil nil nil 0.32 3 180 L 600 7 nil 5700 nil nil nil 0.32 4 200 L 600 14 nil 8900 nil nil nil 2 5 225 S U n d e r C o n s i d e r a t I o n 6 250 M 375 20 nil 22800 nil nil nil 3.2 Flange Designation & Frame Size FLANGE MOUNTED MOTORS Page 11 of 17

1 F 265 B & 132 M 1000 2.4 nil 1200 nil nil nil 0.063 2 F 265 B & 132 M 600 2.4 nil 2600 nil nil nil 0.063 3 F 350 B & 200 L 600 14 nil 8900 nil nil nil 2 NOTE 1 : The values given in this Table are applicable for 10 minutes stalling time; relevant values for 3 minutes stalling time under consideration. NOTE 2: The value of rotor GD 2 as given in column 10 is for general guidance only. Page 12 of 17

APPENDIX - A (Clause 16) PROFORMA FOR TYPE TEST REPORT OF ac ROLLER TABLE MOTORS CONFORMING TO IPSS:1-03-007-14 Name and Address of the Manufacturer Purchaser Purchaser's Order No. Certificate No. Order Acceptance No. NAME PLATE DATA Breakaway Rated Winding Breakaway Rated Frequency Speed in Frame Size/ Enclosure Method Accelera- GD 2 of Torque Voltage Connection Starting Range of Frequency rpm at Flange of tion value Rotor in kgm in Volts Current in Hz Rated Designation Cooling in kgm 2 /h in kgm 2 in A Output 1 2 3 4 5 6 7 8 9 10 11 Page 13 of 17

APPENDIX - A (Contd/-) NAME PLATE DATA (Contd/-) Stalled Rotor Locked Type Mass Rated Rated Class of Bearing Year of Lubrication Withstand Time Rotor of Duty in kg Output Current in A Insulation Designation Manufac- Details Current in kw at Rated ture Voltage 12 13 14 15 16 17 18 19 20 21 Page 14 of 17

APPENDIX - A (Contd/-) TESTS Stator Winding Insulation Resistance High Overspeed Test Stalled Rotor Resistance Voltage Withstand Time per phase Before HV Test After HV Test Test ohms at o C M-ohm M-ohm Withstand Tested at.. rev/min Rotor stalled for... kv for for.. minutes minutes, Temperaturerise minutes at the end of the Test o C 1 2 3 4 5 6 Page 15 of 17

APPENDIX - A (Contd/-) 8. LOAD TESTS Loading Volts Amperes Watts % Slip Load Power Factors Efficiency Condition Guaranteed Test Guaranteed Test No Load 1/2 Load 3/4 Load Full Load 9. TEMPERATURE-RISE TEST Condition of Test Temperature-Rise o C Stator Hours Line Line Cooling Run Volts Amperes Air o C Core by Thermometer Windings by Resistance or Thermometer Breakaway Torque in kgm with.volts Applied Breakaway Starting Current (Locked Rotor) with.volts applied Page 16 of 17

APPENDIX - A (Contd/-) 10. Performance at the lowest and at the Highest Frequency SPEED TORQUE TEST Lowest Frequency Highest Frequency Speed in rev/min Current in amperes Torque in kgm 11. Verification of Acceleration Value Acceleration Value computed as per clause 3 and as per test carried out as specified in Sl.No.13 of Table-2 of IPSS:1-03-007-00(R1D3) kgm 2 /h 14(F) Steady state temperature-rise o C Page 17 of 17