NT PROPORTIONAL CONTROL VALVE, MODEL 6300

Similar documents
NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

Integrated Flow Controller, Model NT6500

INVUE INTEGRATED FLOW CONTROLLERS, MODELS NT6510, NT6520. User guide

NT ELECTRONIC FLOWMETER, MODEL 4400

InVue Electronic Flowmeter, Model NT4400

NT Flowmeter, Model 4401

InVue Electronic Flowmeter, NT4400

NT INTEGRATED FLOW CONTROLLER, MODEL User Guide

Integra Pneumatically Operated Valves

Flaretek Tube Fitting Heated Flare and Assembly Procedures

CRITICAL MATERIALS HANDLING PRIMELOCK FITTINGS

Flarelock II Tube Fitting

Now available. in size. PrimeLocK Fittings. A premium PFA fitting for high-purity and corrosive chemical applications

CR8 Manual Multi-turn Valve

RINSEGARD HP AND HPX. Simultaneously removes trace levels of positively charged ions and fine particles in ultrapure DI water

Integra Manually Operated Distribution Valves

NOWPak Canister Dispense Connector

CRITICAL MATERIALS HANDLING FLUOROGARD RS RESIST STRIPPING FILTERS

Integra Pneumatically Operated Distribution Valves

PrimeLock Fittings. A premium PFA fitting for high-purity and corrosive chemical applications FEATURES & BENEFITS APPLICATIONS

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

CR4 Discrete Valve and Manifold Valve Repair or Replacement Procedure

Ultra Compact UHP Liquid Flow Controllers

Dymension SG Manifold Valves Using Direct Mount Manifold Technology

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

Overview CHEMLOCK PFA HOUSING. Space-saving housing solution enabling hassle-free cartridge changeouts and reduced exposure to chemicals

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

PrimeLock Fittings. A premium PFA fitting for high-purity and corrosive chemical applications FEATURES & BENEFITS APPLICATIONS

FluoroLine Ultrapure PFA Tubing

MODEL U801 PTFE Flo-Controller for UHP Liquid Applications. uhp

Inline Ultrasonic Flowmeter

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

ProMinent Beta Solenoid Diaphragm Metering Pumps

Hydro-Flow Model 2300 Installation and Operation Guide B

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Application Engineering

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

LFC Integrated Flow Control Module. Description.

RESISTIVITY MONITOR/CONTROLLERS

LFC Integrated Flow Control Module. Description Malema Sensors

OPERATOR S MANUAL A

Application Engineering

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Torrento high-flux, The new standard for nondewetting PTFE filters enabling unsurpassed particle protection and yield enhancement

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

G72x Series Direct Spark Ignition Controls

Appendix. Clearance. Skewed profiles. Application Schematics

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

CRITICAL MATERIALS HANDLING PROCESSGARD PES CARTRIDGE AND DISPOSABLE FILTERS

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Models 415 & 425. Electronic Pressure Regulators. Customer Value Proposition: Contact Information:

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Installation, Operation and Maintenance Manual

CRITICAL MATERIALS HANDLING TORRENTO AT SERIES FILTERS

INSTALLATION DATA MANUAL MODEL 148/248/348

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Data Sheet. A-Series Miniature Watertight Pressure Switches

Optimizer Point-of-use Photochemical Filters

INTRODUCTION / TABLE OF CONTENTS

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Installation, Operation & Maintenance Manual


Installation Operation Maintenance ADDENDUM

WAFERGARD III NF-75O IN-LINE GAS FILTERS. Installation and use manual

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

SCHNITZ MOTORSPORTS PNC-202, 2-STAGE PROGRESSIVE NITROUS CONTROLLER USER MANUAL AND INSTALLATION GUIDE NOS PULSE FREQUENCY

VE VVG Series Electronic Two-way Valves Normally Closed

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

A6Z OPERATING MANUAL

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Inductive conductivity meter

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

MFC Integrated Flow Control Module For Slurries and Chemicals. Key Features. applications.

Installation, Operation and Maintenance Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

Mechanical Specifications:

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

Installation and Operation Manual

ESD5500E Series Speed Control Unit

Dissolved Oxygen Measurement System with Air Blast Cleaner

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

CIRCLE SEAL CONTROLS

NOWPak Bottle System. Delivering your critical materials with purity, safety, and process efficiency FEATURES & BENEFITS. Purity.

A3Z OPERATING MANUAL

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Transcription:

P/N 1365 (Rev. B 4/14) NT PROPORTIONAL CONTROL VALVE, MODEL 63 User Guide

Table of Contents Introduction... 2 Principle of Operation... 2 Factory Configured... 2 General Considerations... 2 Line Pressure... 2 Dimensions... 3 Installation... 7 Provided Equipment... 7 Mounting Requirements... 7 Mechanical Installation... 8 Power Supply Requirements... 8 Electrical Connections... 9 Wiring Diagram... 11 Unit Operation... 12 Performance... 12 Operating Environment... 13 Operation and Use Recommendations... 14 Performance... 15 Operational Reliability... 15 Diagnostic Guide... 16 Maintenance... 17 Normal Operation... 17 Valve Homing Function... 17 Reference... 18 Physical Specifications... 18 Electrical Specifications... 18 Ordering Information... 19 Certifications... 2 CE Certification... 2 Repair and Warranty Service... 2 Technical Support... 2 Warranty... 21 Terms and Conditions... 21 For More Information... 21 ENTEGRIS, INC. USER GUIDE 1

Introduction This manual is for use with a standard NT Proportional Control Valve, Model 63. These instruments have been designed for use in high-purity fluid applications within industries that need tightly controlled chemical processes such as the semiconductor, biomedical and solar cell industries. The wetted parts are constructed with PTFE, PFA or other similar high-purity inert materials.! WARNING! Attempting to install or operate standard NT Proportional Control Valves without reviewing the instructions contained in this manual could result in personal injury or equipment damage. Principle of Operation The user provides a setpoint signal that corresponds to the desired valve position. The range code of the product specifies the maximum C V of the unit. The setpoint signal will proportionally control the unit s C V from to maximum C V. The C V curve is linear. For example, 63-CV3-F4-B6-M has a C V of 1. and has a setpoint of 5 VDC. A 2.5 VDC setpoint signal will adjust the valve to a.5 C V. A 3.75 VDC setpoint signal will adjust the valve to a.75 C V. Factory Configured The standard NT Proportional Control Valve is pre-configured from the factory for the C V range chosen by the user. The specified C V range is found on the label of the unit. NOTE: The NT Proportional Control Valve has been factory sealed. DO NOT attempt to remove the cover of the unit. Any attempt at removal of the unit cover will void the warranty. General Considerations Line Pressure The system line pressure (measured at the inlet of the unit) can be -1 415 kpa (-14.5 6 psig) for C V 1 C V 4 range. For C V 7 C V 8, the system line pressure can be -1 55 kpa (-14.5 8 psig). 2 USER GUIDE ENTEGRIS, INC.

Dimensions The following fitting size and flow range combinations are available: Please consult the factory for custom fitting size and flow range combinations. C V 1 C V 4 Ranges Top View B 127. mm (5. ) 4.1 mm (1.58 ) 68.1 mm (2.68 ) 92.2 mm (3.63 ) 114. mm (4.49 ) Side View End View 65.5 mm (2.58 ) A 6.4 mm (.25 ) C Figure 1. C V 1 C V 4 ranges Inlet/Outlet Port Connection C v 1 C v 4 Ranges Dimensions A B C 1 4 Flaretek 142.2 mm (5.6 ) 144. mm (5.67 ) 19.5 mm (.77 ) 3 8 Flaretek 142.2 mm (5.6 ) 144. mm (5.67 ) 19.5 mm (.77 ) 1 2 Flaretek 144.5 mm (5.69 ) 15. mm (5.91 ) 21.6 mm (.85 ) 3 4 Flaretek 153.6 mm (6.5 ) 153.7 mm (6.5 ) 27.4 mm (1.7 ) ENTEGRIS, INC. USER GUIDE 3

C V 1 C V 4 Ranges Top View 127. mm (5. ) B 4.1 mm (1.58 ) 68.1 mm (2.68 ) 92.2 mm (3.63 ) 114. mm (4.49 ) Side View End View 65.5 mm (2.58 ) A 6.4 mm (.25 ) C Figure 2. C V 1 C V 4 ranges Inlet/Outlet Port Connection C v 1 C v 4 Ranges Dimensions A B C 1 4 Pillar Super 3 142.2 mm (5.6 ) 114.3 mm (4.5 ) 19.5 mm (.77 ) 3 8 Pillar Super 3 142.2 mm (5.6 ) 122.2 mm (4.81 ) 19.5 mm (.77 ) 1 2 Pillar Super 3 144.5 mm (5.69 ) 127. mm (5. ) 21.6 mm (.85 ) 3 4 Pillar Super 3 153.6 mm (6.5 ) 136.1 mm (5.36 ) 27.4 mm (1.7 ) 4 USER GUIDE ENTEGRIS, INC.

C V 7 C V 8 Ranges (Flaretek 3 4 and 1 Inlet/Outlet Type) Side View Ø99.8 mm (3.93 ) A C B 49. mm (1.93 ) 6.9 mm (.27 ) Bottom View 27.9 mm (1.1 ) 79.2 mm (3.12 ) 95.3 mm (3.75 ) Figure 3. C V 7 C V 8 ranges Inlet/Outlet Port Connection C v 7 C v 8 Ranges Dimensions A B C 3 4 Flaretek 223.4 mm (8.79 ) 129. mm (5.8 ) 24.4 mm (.96 ) 1 Flaretek 223.4 mm (8.79 ) 133.6 mm (5.26 ) 24.4 mm (.96 ) 1 Pillar 225.7 mm (8.88 ) 146.3 mm (5.76 ) 26.7 mm (1.5 ) ENTEGRIS, INC. USER GUIDE 5

C V 7 C V 8 Ranges (Pillar Super 3 3 4 and 1 Inlet/Outlet Type) Side View Ø99.8 mm (3.93 ) A C B 49. mm (1.93 ) 6.9 mm (.27 ) Bottom View 27.9 mm (1.1 ) 79.2 mm (3.12 ) 95.3 mm (3.75 ) Figure 4. C V 7 C V 8 ranges Inlet/Outlet Port Connection C v 7 C v 8 Ranges Dimensions A B C 3 4 Flaretek 223.4 mm (8.79 ) 129. mm (5.8 ) 24.4 mm (.96 ) 1 Flaretek 223.4 mm (8.79 ) 133.6 mm (5.26 ) 24.4 mm (.96 ) 1 Pillar 225.7 mm (8.88 ) 146.3 mm (5.76 ) 26.7 mm (1.5 ) 6 USER GUIDE ENTEGRIS, INC.

Installation Provided Equipment The product box contains the proportional control valve. For units with Flaretek connections, two nuts are included. For units with Pillar connections, two nuts, two sleeves and two gauge rings are included. NOTE: This unit has been assembled and double-bagged under cleanroom conditions. To maintain purity, only open in cleanroom environment. Mounting Requirements The proportional control valve may be mounted in any orientation. Care should be taken when installing the proportional control valve to avoid fluid leaks. Do not use excessive torque or subject the unit to high heat during installation. The unit and base bracket assembly must be mounted to a solid surface to ensure stability. Verify the body and the electrical cable are free from mechanical stress from the surrounding equipment. RECOMMENDED HARDWARE: C V 1 4 SAE #1 (metric M4) #1 (M4) Pan head #1 (M4) Flat washer C V 7 8 SAE 1 4 (metric M6) NOTE: The proportional control valve requires mounting in the direction of the fluid flow. 1 4 (M6) Pan head 1 4 (M6) Flat washer ENTEGRIS, INC. USER GUIDE 7

Mechanical Installation Prepare and Connect Fluid Lines The standard NT proportional control valve must be used with the proper tubing size and fittings.! CAUTION: Do not tighten the nuts on the fitting connection without tubing in place. Tightening the nuts without the tubing installed may damage the unit s connections. FLARETEK TUBE FITTING: Flare each tube end prior to installation onto the valve fitting. For detailed tube flaring instructions, see Flaretek tube fitting flare and assembly procedures at www.entegrisfluidhandling.com PILLAR SUPER 3 TUBE FITTING: Prepare tube end prior to installation onto the valve fitting. For detailed instructions, see assembly procedures at www.nipponpillar.com! CAUTION: Over-tightening of the nuts with tubing in place will result in damage to the fitting. Power Supply Requirements The power supply range for the proportional control valve is 24 VDC ±1%. The power supply must be regulated and provide minimum 1.2 ampere (nominal) continuous service for each proportional control valve installed. The power supply requirements must be met at the wire connections or connector of the proportional control valve, not only at the power supply itself. The power supply to the unit must provide clean power and must be used only to power similar measurement-type devices. The power supply must not be used to power other inductive loads, such as motors, relays, or solenoids. These devices may produce electrical transients that may affect unit performance. An induced power spike, creating an interruption in power greater than 1 milliseconds in duration, may cause the unit to reset. Loss of power will not cause the loss of any system parameters. Loss of power may allow the valve to open due to applied fluid pressure. In addition to providing clean power, the instrumentation signals and power return lines must not be run within the same conduit or cable along with heavy current demands from motors, charging capacitors or other inductive loads. This may cause a voltage change within the instrumentation signal line, causing erroneous valve operation. Input Impedance of the Voltage Setpoint The input impedance of the voltage setpoint is 37 kohm. Voltage Drop at the 4 2 ma Setpoint Input The 4 2 ma input will drop 4.6 V at 2 ma. Input impedance is 23 ohms. 8 USER GUIDE ENTEGRIS, INC.

Reverse Polarity Protection The proportional control valve is reverse polarity protected; connecting 24 VDC power to any wire will not harm the unit. To operate properly, the polarity must be correct. Over-voltage on any Wire (DC) In the event of accidental application of voltage greater than 24 VDC ±1%, the proportional control valve will withstand continuous 3 VDC on any wire without compromising the unit. Over-voltage on any Wire (AC) The proportional control valve is not designed to withstand the accidental application of 11/22 VAC to any wire. Application of AC voltage will damage the unit. Short Protection The proportional control valve will not be damaged or compromised in any way if any combinations of wires are shorted together. Circuit Protection Entegris recommends fusing the input power line to the NT Proportional Control Valve, Model 63. Use a 2 Amp rated, time-lag fuse for the proportional control valve. Place the fusing on the input power line to the unit at the equipment electrical enclosure to ensure that both the wiring to the unit and the unit itself are protected from any over-current condition. Best practice is to locate the fuse away from the typical liquid exposure or harmful vapor areas. Locating the fuse within the electrical enclosure shared by the power supply enables accessibility for troubleshooting or replacement. Electrical Connections Pigtail Electrical Cable Units specified with a pigtail electrical connection are manufactured with a permanently attached cable. Table 1 details the wire connections for the proportional control valve with a pigtail electrical cable. TABLE 1. WIRE CONNECTIONS PIGTAIL CABLE Wire Color Marker No. Pigtail Cable Function Red 2 +24 VDC Black 8 Ground (+24 VDC common) Violet 6 Factory use only do not connect White 7 Factory use only do not connect Tan 1 Setpoint, current, 4 2 ma Gray 12 Setpoint, common Pink 11 Setpoint, voltage, 1 or 5 VDC Green 9 Valve home input ENTEGRIS, INC. USER GUIDE 9

G-Series Electrical Connector Units specified with a G-Series connector use a Turck brand, versafast style, BSMK type, constructed of polyurethane with a nylon coupling nut. The connector is over-molded onto an electrically shielded, PVC jacketed cable. The pin contacts for the electrical connection are gold-plated for performance and corrosion resistance. The connector is physically keyed, making it easy to connect to a receptacle. Press it into a receptacle and turn the threaded coupling nut to draw the connector and receptacle together until finger tight. G-series connectors to pigtail mating cables are available. See the Ordering Information section of this user guide. Table 2 and the following pin diagram detail the wire connections for the proportional control valve type with G-series electrical connector. TABLE 2. WIRE CONNECTIONS G-SERIES CONNECTOR Pin R E J U G S O P M L A N C T Function +24 VDC Ground (+24 VDC common) Valve home input Setpoint, current, 4 2 ma Setpoint, voltage, 1 or 5 VDC Setpoint, common Factory use only do not connect Factory use only do not connect No connect (NC) No connect (NC) No connect (NC) No connect (NC) No connect (NC) No connect (NC) Mandatory Connections Refer to the wire connections in Table 1, Table 2 and the appropriate Wiring Diagram on page 11. NOTE: The Valve home input +24 VDC must be referenced to the same ground as the main power source ground 2-Black/Pin E connection. See the Maintenance section of this user guide for valve homing instructions. Consult factory with any questions about electrical installation. Unused Connections The 3-Violet/Pin O and 4-White/Pin P wires are for factory use only. Do not connect to power supply or ground. These wires must remain disconnected. Plug Orientation, Face View C O N E A P M R U G L S T J 1 USER GUIDE ENTEGRIS, INC.

Wiring Diagram For 4-2 ma Setpoint Normally open switch 8-Green/Pin J For valve homing Electrical cable 1-Red/Pin R (+) 2-Black/Pin E ( ) Power supply 24 VDC ±1% 6-Gray/Pin S ( ) 5-Tan/Pin U (+) Setpoint control signal 4 2 ma For Voltage Setpoints Normally open switch 8-Green/Pin J For valve homing 1-Red/Pin R (+) 2-Black/Pin E ( ) Power supply 24 VDC ±1% Electrical cable 6-Gray/Pin S ( ) 7-Pink/Pin G (+) Setpoint control signal 5 VDC or 1 VDC ENTEGRIS, INC. USER GUIDE 11

Unit Operation Performance* C v 1 F2 / W2 ( 1 4 ): Max C v =.16 Cv.2.18.16.14.12.1.8.6.4.2 Calculated Cv.16.14.12.1.8.6.4.2 1 2 3 4 5 6 7 8 9 1 11 12 13 Analog Setpoint Percentage Kv C v 2 F3 / W3 ( 3 8 ): Max C v =.68 Cv.9.8.7.6.5.4.3.2.1 Calculated Cv.7.6.5.2.1 1 2 3 4 5 6 7 8 9 1 11 12 13 Analog Setpoint Percentage.4.3 Kv C v 3 F4 / W4 ( 1 2 ): Max C v = 1. Cv 1.2 1..8.6.4.2 Calculated Cv 1..8.6.4.2 Kv 1 2 3 4 5 6 7 8 9 1 11 12 13 Analog Setpoint Percentage 12 USER GUIDE ENTEGRIS, INC.

C v 4 F6 / W6 ( 3 4 ): Max C v = 2.8 Cv 3.5 3. 2.5 2. 1.5 1..5 Calculated Cv 2.5 2. 1.5.5 1 2 3 4 5 6 7 8 9 1 11 12 13 Analog Setpoint Percentage 1. Kv C v 7 F6 Max C v = 5.6 Cv 7. 6. 5. 4. 3. 2. 1. Calculated Cv 1 2 3 4 5 6 7 8 9 1 11 12 13 Analog Setpoint Percentage 6. 5. 4. 3. 2. 1. Kv C v 8 F8 / W8 Max C v = 1. 12. 11. 1. 9. 8. 7. 6. 5. 4. 3. 2. 1. Cv Calculated Cv 1. 8. 6. 2. 1 2 3 4 5 6 7 8 9 1 11 12 13 Analog Setpoint Percentage 4. Kv * Graph data is representative and each valve needs to be characterized with the application to optimize performance. ENTEGRIS, INC. USER GUIDE 13

Operating Environment Storage Temperature Range The proportional control valve can withstand storage temperatures between -4 65 C (-4 149 F) with no permanent effect on the performance of the device. Operating Ambient Temperature Range The proportional control valve is designed to operate in ambient temperature, cleanroom environments. Units are specified to operate at temperatures of 1 65 C (5 149 F). For operation above 65 C (149 F), contact the factory. Operating Process Temperature Range Units indicated have a range of acceptable process temperatures of 1 65 C (5 149 F). For operation above 65 C (149 F), contact the factory. Line Pressure The system line pressure (measured at the inlet of the unit) can be -1 415 kpa (-14.5 6 psig) for C V 1 C V 4 range. For C V 7 C V 8 range, the system line pressure can be -1 55 kpa (-14.5 8 psig). Unit Enclosure The standard NT Proportional Control Valve cover is factory sealed and should not be tampered with or opened. Spray-down or temporary immersion will not compromise the performance of the unit. NOTE: Any attempt to remove, tamper with or open the proportional control valve cover will void the warranty. Operation and Use Recommendations NOTE: Unit is shipped in an open state. System Valving Considerations The NT Proportional Control Valve, Model 63 can be installed with upstream and/or downstream on/off valves. However, some precautions should be taken to ensure longevity and proper operation of the proportional control valve. The proportional control valve will close under two conditions: 1) Zero value setpoint 2) Valve Homing signal command activated If the proportional control valve closes while upstream or downstream valves are closed, this may create a high level pressure condition in the fluid tubing due to compressed liquid. This high pressure condition may lead to inaccurate homing of the device Figure 5. Installation and operation example with two on/off valves 14 USER GUIDE ENTEGRIS, INC.

(indicated by temporary port-to-port leaking), a small amount of media escaping via the weephole, and/or damage to the device. To address this issue, one possible solution is to keep the on/off valves upstream and downstream of the proportional control valve open at all times. If this is not possible, the proportional control valve should be closed first, allowing adequate time before either the upstream or downstream valves are closed. Valve Under No-power Condition The proportional control valve does not rely on a spring to close. The motor movement is electrical. Loss of electrical power will suspend the valve movement. For example, if the valve was partially open during loss of power, the valve will remain partially open. Normal operation will resume when power is reapplied. In an unpowered state, the valve could be forced open with excessive line pressure. Performance Response Time Response time is defined as the length of time required for the proportional control valve to complete valve movement to match a new setpoint signal. The maximum response time for C V 1 4 is <2 seconds from 5 95% full scale. The maximum response time for C V 7 8, is <4 seconds from 5 95% full scale. The proportional control valve will accept setpoint changes within 5 milliseconds of receiving the new setpoint value. When power is first applied to the unit (for example, during a startup sequence), the unit will reach the correct valve position within ten seconds. Temperature Increase at Unit Enclosure You may notice a slight temperature increase of the unit cover while in an ambient environment after warmup, when idling or while controlling flow. This is normal. Operational Reliability Redundant Process Seals All internal process wetted seals are redundant, i.e., there is a secondary seal that prevents process fluid from reaching the interior of the device in the case of a primary seal failure. Weep holes are provided from the secondary containment regions. Drop and Topple If the unit topples over from a 45-degree angle onto a bench top, the performance will not be compromised and the unit will not be externally damaged. Cable Pull The cable will withstand a static pull test of 9.1 kg (2 lbs.) straight and 4.5 kg (1 lbs.) at 9 degrees without being damaged. ENTEGRIS, INC. USER GUIDE 15

Diagnostic Guide Symptom Possible Causes Suggestions 1. Unit is unresponsive 2. Unit is unable to meter flow 3. Unit operation is unstable 4. Unit causes high pressure when closing 5. Unit does not close 6. Unit leaks fluid out of weep hole No power No setpoint signal Rezero line active Unit is undersized Unit is oversized Unstable setpoint signal Unit installed backwards Unstable pressure Unstable setpoint signal External valving External valving entrapping a fixed volume Foreign object in valve Overpressure on unit Check power connections or fusing. Check setpoint wiring for correct setup. Verify setpoint code of the proportional control valve matches your wiring setup and applied setpoint. Clear rezero line. Use a larger C V unit. Use a smaller C V unit. Check wiring and setpoint electrical stability. Verify inlet/outlet connection. Check applied pressure stability and/or stability of downstream backpressure. Check wiring and setpoint electrical stability. Verify the unit does not close against a fixed volume, trapped between valves (the proportional control valve can be one of the two valves). Stepper motor valve closes and creates entrapped fluid. Close unit before closing external valve. See page 14 for more information. Clear obstruction with back flush/ forward flush procedure. Intermittent single overpressure event. Monitor for future instances. Continuous diaphragm rupture. Call factory for more information. 16 USER GUIDE ENTEGRIS, INC.

Maintenance Normal Operation During normal operation, the standard NT Proportional Control Valve, Model 63 requires no maintenance, other than a periodic valve homing of the unit. In applications with greater movement duty cycle, more frequent valve homing is recommended. At the time of unit power-up, and any subsequent power cycle, the proportional control valve will perform a valve homing procedure before becoming active. Valve Homing Function NOTE: The following procedure must be followed precisely to ensure proportional control valve homing. 1. The proportional control valve homing function requires the use of the same 24 VDC ±1% power source that is used to power the unit. 2. Apply 24 VDC ±1% to the 8-Green/Pin J wire to initiate valve homing routine, for a minimum of 1 second. The 24 VDC for valve homing must use the same ground as the ground 2-Black/Pin E wire. Only apply 24 VDC to this 8-Green/Pin J wire, long enough to re-home the valve. The valve homing will be complete within 5 seconds. NOTE: The valve homing function will remain active and at home position as long as 24 VDC is applied to the valve home input wire. In most applications, the valve homing procedure may be automated using switches, a PLC or other logic proportional control valve devices. ENTEGRIS, INC. USER GUIDE 17

Reference Physical Specifications Materials of construction: Wetted parts Nonwetted parts Body and diaphragms PTFE or PFA Polypropylene, Viton, PVDF Response time: C V 1 C V 4 <2 seconds from 5 95% full scale Pressure range*: Over pressure limit: C V 7 C V 8-14.5 6 psig (C V 1 C V 4) 1 psig Process temperature**: 1 65 C Setpoint input signal: Enclosure: Connection type: <4 seconds from 5 95% full scale -14.5 8 psig (C V 7 C V 8) 4 2 ma, 1 VDC, 5 VDC; separate homing line also included NEMA 5 / IP54 Flaretek tube fitting and Pillar Super 3 tube fitting Note: Preliminary specifications and features subject to change. * Please consult the factory for pressure ranges from 6 8 psig. ** Please consult the factory for temperatures from 65 8 C. Electrical Specifications Input voltage: Input current: Impedance of setpoint input (voltage): Voltage drop, current setpoint input: Electrical connection: 24 VDC ±1%, regulated 1. A nominal, 1.2 A peak 37 kohm <4.6 Volts @ 2 ma @ 23 ohm FEP or PVC-jacketed cable 18 USER GUIDE ENTEGRIS, INC.

Ordering Information The model number can be established using the following chart. NT Proportional Control Valve 63 Base Model Cv C V 1.16 maximum C V (only F2 / W2) C V 2.68 maximum C V (only F3 / W3) C V 3 1. maximum C V (only F4 / W4) C V 4 2.8 maximum C V (only F6 / W6) C V 7 5.6 maximum C V (available in F6) C V 8 1. maximum C V (available in F8 or W8) Inlet/Outlet Type F2 1 4 Flaretek tube fitting F3 3 8 Flaretek tube fitting F4 1 2 Flaretek tube fitting F6 3 4 Flaretek tube fitting F8 1 Flaretek tube fitting W2 1 4 Pillar Super 3 tube fitting W3 3 8 Pillar Super 3 tube fitting W4 1 2 Pillar Super 3 tube fitting W6 3 4 Pillar Super 3 tube fitting W8 1 Pillar Super 3 tube fitting Electrical Connector Type V6 PVC-jacketed 6 pigtail electrical cable V12 PVC-jacketed 12 pigtail electrical cable V3 PVC-jacketed 3 pigtail electrical cable B6 FEP- jacketed 6 pigtail electrical cable B12 FEP- jacketed 12 pigtail electrical cable B3 FEP- jacketed 3 pigtail electrical cable G1 PVC-jacketed 1 electrical cable terminated with 14-pin Turck connector* G6 PVC-jacketed 6 electrical cable terminated with 14-pin Turck connector* G12 PVC-jacketed 12 electrical cable terminated with 14-pin Turck connector* G3 PVC-jacketed 3 electrical cable terminated with 14-pin Turck connector* Setpoint Input Signal K 4 2 ma L 1 VDC M 5 VDC *14-pin mating cable required for installation Example model number: 63-CV1-F2-B12-K ENTEGRIS, INC. USER GUIDE 19

Ordering Information (continued) Accessories Part Number 14G2 14G5 14G1 Description 2 meter mating cable, 14 pin Turck to pigtail, PVC-jacketed 5 meter mating cable, 14 pin Turck to pigtail, PVC-jacketed 1 meter mating cable, 14 pin Turck to pigtail, PVC-jacketed Certifications CE Certification Please visit www.entegrisfluidhandling.com for the most current information. Repair and Warranty Service Repair and warranty service is available at the Entegris factory. To expedite the return and repair of the product, contact Entegris at +1 8-394-484. A Return Materials Authorization (RMA) number, MSDS requirements and a product packaging and return procedure will be provided at that time. If the product being returned was exposed to a hazardous substance, a copy of the Material Safety Data Sheet (MSDS) for each hazardous substance identified must be included with the returned product. Technical Support For technical support, contact the factory at +1 8-394-484. Please have the complete model number, chemical and application information ready when calling.! WARNING! Mishandling products exposed to a hazardous substance may result in death or serious injury. 2 USER GUIDE ENTEGRIS, INC.

For More Information Please call your Regional Customer Service Center today to learn what Entegris can do for you. Visit www.entegris.com and select the Customer Service link for the center nearest you. Terms and Conditions of Sale All purchases are subject to Entegris Terms and Conditions of Sale. To view and print this information, visit www.entegris.com and select the Legal Notices link from the footer. Product Warranties For Product Warranties, visit www.entegris.com and select the Legal Notices link from the footer. ENTEGRIS, INC. USER GUIDE 21

Entegris, the Entegris Rings Design, Creating a Material Advantage, NT, Flaretek and FluoroPure are registered trademarks of Entegris, Inc. Turck is a registered trademark of Turck, Inc. Viton is a registered trademark of DuPont Dow Elastomers, L.L.C. Pillar is a registered trademark of Nippon Pillar Packaging Company, Ltd. ENTEGRIS, INC. Corporate Headquarters 129 Concord Road Billerica, MA 1821 USA Customer Service Tel. +1 952 556 4181 Customer Service Fax +1 952 556 822 In North America 8 394 483 www.entegris.com 211 214 Entegris, Inc. All rights reserved Printed in USA P/N 1365 (Rev. B 4/14) 362-626ENT-414