Live Wire Owner s Manual

Similar documents
Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

MODEL 901 OPERATING INSTRUCTIONS

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

ELB ELB

5. Alignment and Adjustments

OPERATORS MANUAL FOR KAFURTER ROTARY TOPPERS MODELS: TP110, TP140, TP160, TP170

SAFETY BULLETIN ELECTRICITY THE RULES HOW TO STAY SAFE WHEN WORKING AROUND POWER LINES AMERICAN CONCRETE PUMPING ASSOCIATION

Owner's Manual. Remote Security and Convenience System INS0866 8/98

PHASERS. Operating and Instruction Manual. a n d A C C E S S O R I E S

BASIC ELECTRICAL MEASUREMENTS By David Navone

Operation Guide. Operation Guide. Winnebago Hydraulic Leveling Systems by Kwikee. Introduction. Table of Content WARNINGS

R & D SPECIALTIES ROTROL I USER'S MANUAL

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

82V LITHIUM-ION BATTERY CHARGER GC 400

PowerOhm Installation Manual for BM R Series Braking Modules

1. Inspection and Maintenance

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

HI-POT/CONTINUITY TESTER Model PLEP01

Owner and Operating Manual for

INSTALLATION: HOW IT WORKS: SensiStat Energy Saver Refrigeration Controller. both the holding plate temperature and refrigeration box temperature.

Operation Guide. Hydraulic Leveling Systems #2000, #2010, #3000, and # Table of Content. Introduction

G76x Direct Spark Ignition Controls

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

LTX RF LEVEL SENSOR. Instruction Manual

User s Manual. Automatic Switch-Mode Battery Charger

Mini Multimeter with Non-Contact Voltage Detector (NCV)

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS

PLEASE READ THOROUGHLY PRIOR TO USING VILO Vinyl Liner Leak Locator

GENERAL <ELECTRICAL>

GENERAL <ELECTRICAL>

OPERATING INSTRUCTION

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

PowerOhm Installation Manual for LG ATV Series Braking Modules

SensiStat Energy Saver Refrigeration Controller Revision 1.14

USER S GUIDE HIGH INTENSITY ULTRASONIC PROCESSOR

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

Laser Receiver Model MCR3. Operator's Manual

OPERATION MANUAL ESX-2

Installation Instructions K656CY, K656CH and K656I Deadbreak Receptacles

Battery Charger JCB-FCH12Li

Differential Pressure Transmitter

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

PowerOhm Installation Manual for BM R Series Braking Modules

Change Your Tail Wheel Bearings (and Races)

Document ID# Cadillac CTS

TABLE OF CONTENTS. Page 1

3 Phase Smart Controller

PowerLevel s e r i e s

Transfer Switch GPTS 30

ITS-50R TRANSFER SWITCH OWNER S MANUAL

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

Installation and User Manual. with RAIN SENSOR.

JUMP STARTING POWER PACK QUICK START GUIDE. Model No. 66.1

Owner s Manual with Assembly Instructions Please read this manual and save it. For Model RC09075

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

JUMP STARTING POWER PACK QUICK START GUIDE. Model No. 44.1

HYDRAULIC LEVELING SYSTEMS OPERATIONS MANUAL (For systems with touch pad part number , , , , or no number at all)

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

A.W. SPERRY INSTRUMENTS INC.

OPERATOR S MANUAL HWH COMPUTER-CONTROLLED 700 SERIES LEVELING SYSTEM. FEATURING: Touch Panel Leveling Control Air Leveling With Tag Axle Dump

PORTAGAUGE 4 USER MANUAL

MODEL MAS BAR TO BAR TESTER INSTRUCTIONS

Road Service Quick Reference Guide 2016 Lincoln MKT. Quality and Education Services AAA Automotive 1000 AAA Drive Heathrow, FL 32746

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Product Installation Instructions. Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526

PATENT PENDING. Phone: (877) Operation and Service Manual

Informer Compact Series

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM Cap Sensors

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Table of Contents Title Page No.

Operators Manual. True RMS Voltstik. Radio Linked Multiple Reading Voltmeter. SensorLink

Owner s Manual with Assembly Instructions Please read this manual and save it. For Model RC09037

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

Under Axle Jack Max. Capacity: 25 Tons

Safety Working with LV Drives

Road Service Quick Reference Guide 2016 Lincoln MKX. Quality and Education Services AAA Automotive 1000 AAA Drive Heathrow, FL 32746

IN-LINE HYDRAULIC FLOW TESTER

IEEE Insulated Conductors Committee. Subcommittee B, Cable Accessories

Road Service Quick Reference Guide 2016 Lincoln MKZ / MKZ Hybrid. Quality and Education Services AAA Automotive 1000 AAA Drive Heathrow, FL 32746

WARNING ATTENTION. Please read this information carefully before operating your safe.

Road Service Quick Reference Guide 2016 Lincoln MKC. Quality and Education Services AAA Automotive 1000 AAA Drive Heathrow, FL 32746

Model Insulation Tester / Megohmmeter. User Manual

SawStop Quick Start Guide

An unwritten rule says that when a. Cures for a sick spot welding machine. Figure 1. To test the secondary of the welding machine,

The Presidium Gem Tester features the following:

Marin Control Digital

Instruments and Meters

GENUINE MUD FLAP (REAR)

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY

Thunder Power Tarp Kit Operation Guide

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

MODEL UC 14YFA. Hitachi. Power Tools TECHNICAL DATA AND SERVICE MANUAL CHARGER UC 14YFA SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT

Presenter s Notes SLIDE 1. Before darkening the room, offer a welcome and overview. Begin by introducing the program and its topic:

Probe Driver for Visual Plus 3. (c) , Saryna Technologies LLC/Advanced Inspection Technology

Installation, Operation and Maintenance Manual

Self-Testing Industrial Series

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Transcription:

Live Wire Owner s Manual Battery Replacement Introduction Features Precautions Tool Description Purpose Using the Tool Model MB0414L, MB0414H www.origocorp.com Operating the Tool How it Works Quick Summary Notes FOR INFORMATION Greg Piesinger President Origo Corporation 480-473-1995 gpiesinger@origocorp.com MB0414L Rev. 031001 All rights reserved, Origo Corporation, 2004

Live Wire Owner s Manual - Model MB0414L, MB0414H 1 Battery Replacement The first indication of a low battery is a steady pulsing of the lights during a measurement. The Live Wire requires a certain level of voltage to turn on and once this has been done, load may draw a weak battery down to a level where the tool must shut off. After that occurs, the battery voltage will rise above the limit voltage again turning the tool on, thus repeating the process. The result of this cycle is a discernable steady pulse of the lights until the battery completely fails. Replace the battery immediately. To access the battery compartment, use a screwdriver to remove the four (4) corner screws on the back of the body of the instrument. Replace with new alkaline 9VDC battery. Introduction Thank you for purchasing the Live Wire by Origo. You now own the finest URD status indication tool on the market today. It is mandatory for users to read this manual carefully and to understand the capabilities and limitations of this tool, as it contains IMPORTANT safety information. If you have any questions on how to use the tool or how to apply it in the field, call Origo Corporation at 480-585-1844. For technical questions by maintenance shop personnel, call Returns, Warranty, and Technical Support at 480-473-1987.

Live Wire Owner s Manual - Model MB0414L, MB0414H 2 Features Live Wire MB0414L Detects Energized Status in URD Un-Jacketed Cables Detects Energized Status in URD Jacketed Cables Attaches easily to hotstick 9VDC alkaline battery Precautions IMPORTANT!! Because you entrust your personal safety with this instrument, always test the battery before every operation. If you suspect for any reason that the instrument may be damaged or abused, thus affecting the operation of the tool, return the tool immediately to Origo for evaluation and/or repairs. Follow all proper procedures deemed safe by your company or OSHA and wear PPE, Personal Protection Equipment at all times when verifying any cable s energized status. This tool shall only be used by qualified and trained personnel. CAUTION: Never contact the Spring Probe and the Barrel to the semi-conductive layer at the same time. This will result in obtaining a false dead GREEN light indication due to a valid resistive value being read by the tool but no voltage potential. WARNING: Never contact energized parts or conductors with any portion of the Live Wire tool. The tool is NOT to be applied to any energized source and will result in catastrophic failure of the instrument. PRECAUTION: Always take a multitude of samples and never depend on only one reading. Due to variations in semi-conductive values, the user must consider an average of samples.

Live Wire Owner s Manual - Model MB0414L, MB0414H 3 ALERT: The Heater Adapter retains a harmful amount of heat for a very long time. Always use the supplied heat pad for installation and removal. ADVICE: Spiking must be performed while using all safety procedures adopted by your company and/or by OSHA. Remember to always wear your PPE when performing any status verification or working on or around URD cables. and Always Spike Your Cables Tool Description 1. Universal Hotstick Adapter 2. Fiberglass Hotstick Extension 3. Status Light Panel 4. Nomenclature 5. Stainless Steel Barrel 6. Heater Adapter Threads 7. Spring Probe

Live Wire Owner s Manual - Model MB0414L, MB0414H 4 Purpose The Live Wire instrument is designed to determine the voltage status of URD cables. It is intended to be used in dig-in and cut-in situations to indicate if the URD cable in question is either energized or de-energized prior to working on or spiking the cable. If the Live Wire light panel indicates the cable is live, (RED light), then spiking of the energized cable is obviously not recommended and further steps must be taken to ensure a de-energized state of the cable. If the Live Wire indicates the cable is de-energized or dead (GREEN light), then spiking procedures can be continued if needed for the job. Other indications of the light panel and their meanings are addressed further in this booklet. Dead or De-energized ( Green ) Indication Spiking must be performed while using all safety procedures adopted by your company and/or OSHA. Remember to always wear your PPE when performing any status verification or working on or around URD cables.

Live Wire Owner s Manual - Model MB0414L, MB0414H 5 Using the Tool Non-Jacketed / Direct Buried Concentric Cables On non-jacketed URD cable, the condition of the semi-conductor layer varies considerably depending on the cable s age and exposure to the elements. It is not unusual to find either small spots or large areas of the semi-conductor layer that have degraded. When the semi-conductor layer degrades, its resistance may increase to the point where the Live Wire tool either will not turn ON or the OPEN light will illuminate on the light panel. However, in most cases, by simply probing other areas on the cable, a good area of semi-conductor can be found and a correct indication of status can be obtained. The user should always take multiple samples on any URD cable to make sure of a correct determination of energized status. On excessively corroded URD cable, it may be necessary to hot-brush the URD cable, in the area to be probed, to remove concentric and semiconductor corrosion thus allowing the Live Wire tool to either turn ON or to extinguish its OPEN light. TIP: The use of a hot clamp placed around the cable with a hot stick can also assist in obtaining correct and accurate indications. See How It Works section for more information on when to use the hot clamp. TIP: Simply cleaning the cable, by pouring water on the area to be tested, greatly increases the ability of obtaining a status light. Dirt or other foreign material can cause a complete loss of status acquisition capability and will many times prevent the Live Wire from turning ON. Jacketed Concentric Cables All jacketed cables, including semi-conductive jackets, require the Heater Adapter; part number MB0414H, to be attached to the Live Wire. Heated intrusion into the jacket is necessary to make contact to the concentric neutral and the semi-conductive layer. High temperatures caused by sun exposure or overload can cause a large increase in the semi-conductor layer resistance on some cables which will give an OPEN light status. A cool down period is recommended.

Live Wire Owner s Manual - Model MB0414L, MB0414H 6 Operating the Tool 1. Always check the battery before using the Live Wire tool. This can be done by shorting the Barrel to the Spring Probe and viewing a SHORT light indication. Pressing a knife blade or coin against the Spring Probe until the metal makes contact with the Barrel is recommended. If the SHORT light does not appear or if the SHORT light pulses on and off repeatedly, the battery needs replacing. 2. Always attach the Live Wire tool to the appropriate length of hotstick advised by your company s safety regulations and/or by OSHA. Battery Check 3. Make every attempt to hold the tool s Barrel perpendicular and near the center of the cable s diameter. Non-Jacketed URD Cable 4. Apply the Spring Probe protruding from the Barrel against the semiconductive layer. Press firmly and with enough pressure to compress the Spring Probe until the Barrel makes contact with the concentric wire. 5. Be as steady as possible and allow the light panel to process the reading. Although this requires only seconds to complete, the tool is evaluating many measurements. Light panel flickering is common during this time. The user should ignore any quick flashing of lights or actions in the light panel and wait for a steady and determined light indication. This process of evaluation occurs each time the tool is reapplied or moved.

Live Wire Owner s Manual - Model MB0414L, MB0414H 7 6. DO NOT ROCK THE TOOL. Rocking or adjusting the tool while being pressed can cause damage to the Spring Probe or the Barrel threads used to attach the Heater Adapter and does not give the user any advantage in sampling. Simply reapply the tool in another area of the cable. 7. If NO lights or a steady OPEN light is obtained, simply move the tool to a new location on the cable. If all samples indicate OPEN, the user can ascertain that either the URD cable is corroded or the semiconducting layer of the cable has degraded to a point where the resistance is higher than the Live Wire tool permits. TIP: Correct Application Ground currents or EMF can induce current flow on the semi-conductor. Excessive amounts can cause the Live Wire to indicate a RED or an UNKNOWN light on a de-energized cable. To avoid this, the user may decide to apply an appropriate size hot tap, clamp around the cable near the test area. This provides a very stable connection between the concentric and semi-conductor and allows for a correct indication of dead or GREEN light. Jacketed URD Cable 8. Follow steps 1 through 3. 9. Attach the Heater Adapter, part number MB0414H to the threaded end of the Live Wire tool. 10. Insert the supplied thermometer into the hole in the end of the Heater Adapter.

Live Wire Owner s Manual - Model MB0414L, MB0414H 8 Thermometer Insertion 11. Apply heat to the large metal end forward of the white insulator using a propane or heat gun until the temperature reaches 200 degrees Centigrade. DO NOT HEAT THE METAL STEM OR THE GLASS DIAL OF THE THERMOMETER. AVOID HEATING THE ADAPTER HIGHER THAN THE RECOMMENDED DEGREES AS THESE EXCESSIVE TEMPERATURES MAY RESULT IN DAMAGE Heating the Adapter 12. Remove heat and temperature gauge.

Live Wire Owner s Manual - Model MB0414L, MB0414H 9 13. Hold tool as perpendicular as possible to cable and place the hot end of Heater Adapter against jacket. Apply small amount of pressure, or just allow the weight of the tool and hot stick, to begin intrusion. The Heater Adapter will slowly melt into the jacket and make contact with the concentric neutral and the semi-conductive layer underneath. Withdraw as soon as a light indication is given and repeat. It is common to obtain SHORT indications due to the center of the Heater Adapter being applied onto or near a concentric. Simply move a small distance from the original area and take another sample. 14. It may be necessary to re-heat the adapter, but under normal conditions, the Heater Adapter will retain enough heat to allow the user to take multiple samples of status. Heater Removal 15. Sampled cable not spiked may be repaired using either semiconductive tape or an appropriate Jacket Repair kit.

Live Wire Owner s Manual - Model MB0414L, MB0414H 10 Heater Penetration NOTE: THE HEATER ADAPTER IS INTENDED FOR PRE-SPIKING USE ONLY. RANDOM SAMPLING OF JACKETED CABLES IS NOT RECOMMENDED. Short Indication 16. When finished, wipe off melted jacket material from the heater. BE VERY CAREFUL NOT TO GET JACKET MATERIAL IN THE THERMOMETER HOLE. Q-tips work very well for removing melted jacket material.

Live Wire Owner s Manual - Model MB0414L, MB0414H 11 17. Remove the heater using the supplied insulated storage bag. CAUTION: THE METAL END OF THE HEATER ADAPTER CAN RETAIN HARMFUL HEAT FOR UP TO AN HOUR AFTER USE. How it works The key to the Live Wire is the capacitance coupling between the conductor and the semicon. (You could relate this coupling to that used on the voltage probe on elbows.) This capacitance coupling results in current flow between the semicon and the neutral wires. The Live Wire first must measure resistance to ensure that it has the proper connection to the neutral wires and the semicon. Corrosion or degraded semicon can prevent a proper connection to the neutral and semicon. Exposure to contaminants and age can degrade semicon to the point that its resistance becomes too high to obtain a valid status indication. If the resistance is correct, the Live Wire can then detect the voltage between the semicon and neutral and use it to indicate the cable status. To be safe, this voltage must either be below a low threshold to indicate that the cable is dead or GREEN and above a higher threshold to indicate that the cable is live or RED. If it is between the two thresholds, the Live Wire will indicate the status as UNKNOWN. The user need only reapply the tool to another spot to obtain a valid status indication. Corroded or detached neutral wire can cause the voltage measurement to be taken over a length much longer than the normal 1/8 gap between the neutral and semicon. Ground currents, which are always present, can give rise to small voltage differences over this longer measurement length which can be falsely interpreted as coming from the center conductor of a live cable. By using the cable clamp or hot tap, the user forces the probe voltage measurement to be taken over the desired 1/8 gap which eliminates this source of error. On jacketed cables, the jacket material both prevents neutral corrosion and holds the neutral tight against the semicon thus eliminating this source of error. Finally, the user will at times encounter situations in which the tool will not be able to indicate cable status due to the poor condition of the cable. The Live Wire tells the user this via the OPEN and SHORT lights. If the semicon has degraded to a point of becoming an insulator, a tic tracer or other no contact voltage sensor may be used for attempting status. If the tic tracer says the cable is live, it probably is live. However, if it says it is dead, one can t be sure because the semicon may still be enough of a semiconductor to prevent the tic tracer from detecting the center conductor voltage.

Live Wire Owner s Manual - Model MB0414L, MB0414H 12 Remember, the most important factor in determining voltage status in URD cables is to always follow your company s and OSHA safety rules. TIP: Never Rock, twist or move the Live Wire tool in an attempt to get a better sample. This only causes the tool to try to re-establish and will cause the lights to flash randomly. The flashing of the lights is similar to the movement of the needle on an analog voltmeter or the rise in numbers on a digital voltmeter. Always Wear Your PPE Quick Summary NO LIGHTS = Either battery is dead, URD cable is corroded, or semi-conductor resistance is too high to turn on the Live Wire tool. ON / SHORT = Spring Probe and Barrel are shorted against concentric or semi-conductor resistance is too low to obtain a valid status indication. ON / UNKNOWN = Live Wire tool has turned on and URD cable resistance is in range but voltage is too high to indicate GREEN and too low to indicate RED. ON / OPEN = Either URD cable is corroded or semi-conductor resistance is too high to obtain a valid status indication. ON / GREEN = URD cable is Dead or de-energized. ON / RED = URD cable is Live or energized. CAUTION The Live Wire has been thoroughly tested and has worked correctly on all URD cables encountered thus far. However, since the age of URD cables in the field span a period of more than 30 years, it was impossible to test the Live Wire on every type of cable or in every possible environment. Therefore, the possibility exists that a unique situation might be encountered in which the Live Wire will fail to give the correct status indication.

Live Wire Owner s Manual - Model MB0414L, MB0414H 13 Because of the nearly infinite variation in cable characteristics and testing situations, it may be impossible to totally eliminate all hot spiking. However, the design goal of the Live wire was to reduce the incidence of live spiking by a very large factor. Since the possibility of live spiking still exists, it is important to follow all safety procedures and Always Spike Your Cables TIP: A primary feature of the Live Wire is that the OPEN, and SHORT lights inform the user when the cable condition is such that a reliable status measurement cannot be obtained. If, after cleaning the cable and multiple attempts, the unit fails to turn ON or extinguish these lights, it indicates that status information cannot be obtained on this cable. Severely Corroded Semi-Conductor and Concentric Notes Always spike my cables Always wear my PPE Do a Safety Favor, think Safety Every Day