Manual Thickness gauge PCE-CT 30

Similar documents
Instruction Manual. Coating Thickness Gauge. Optionally with Memory

Coating Thickness Gauges

TABLE OF CONTENTS 11.0 WARRANTY

MANUAL ELECTROMAGNETIC FIELD RADIATION TESTER EMF 823

Manual Calibrator PCE-IC1

Model LE-300C/LH-300C/LZ-300C Coating Thickness Tester. Operating Manual

MANUAL TH-134 TH-134

Elcometer 415. Coating Thickness Gauge. Operating Instructions

NOTES TABLE OF CONTENTS

Manual Balanza dosificadora PCE-ABZ 200C

Elcometer 415. Coating Thickness Gauge. Operating Instructions

Operating manual Platform/floor scales

PORTAGAUGE 4 USER MANUAL

Operating Instructions Precision balance

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

DIGITAL FORCE GAUGE FM-204

Elcometer 311. Elcomotor Refinishing Gauge. Types F and FNF. Operating Instructions

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Operating instructions Platform/floor scales

Diesel Cooker x100. Operating and Maintenance Instructions

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

Inclinometer for Electronic Wheel Alignment Machines

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

Portable pressure calibrator, Wally Box III Model CPH7600

BRAKE TESTER DECELEROMETER

Operating and Maintenance Instructions. Abteilung TB, Schell Seite 1 8 SERIES 56

CITIZEN. series. Precision Balances

Inlet Controller SB3500 USER'S MANUAL

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

Manual Rotation Meter PCE-AT 5

POWER. Switch opening. Enter/Exit Menu Menu Scroll Increase/Decrease Setpoint GCE SERIES MODEL 10AFE MODEL 20AFE

Single-Input Thermocouple. Thermometers Type J, K, T

200 m IP67. Partner for specialist retailers. Precision Offers. In Germany at home in demand worldwide. valid until

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

B-RAD Select USER MANUAL TABLE OF CONTENTS

COATING THICKNESS GAGE NOVOTEST TP-1

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Injector. General Information CAUTION. Use only the specified injector for the engine.

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

DIGITAL TORQUE GAUGE MODEL BTGE-G

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

OPERATING MANUAL EARTH RESISTANCE METER MRU-20

Flue Gas Analyzer IMR 1100F

How do I get the most out of my new smart energy display?

Digital Torque Wrench

Ultrasonic heat meter

Lumitester PD-30. Instruction Manual. Table of Contents

Battary powered cutting tool. AS6-S32 Art convincing solutions. Video

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Visit us at

DISCHARGER-ANALYZER BDX USER'S MANUAL

How to use the NOx sensor emulator NOXEM Part 1

Temperature multi-function calibrator Model CTM

RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs

Operating Instructions For The X-Seal Manual Thermal Sealer

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Accessories Encoders COUNTERS CONTROLLERS ENCODERS. Features. Cable-operated mechanism

testo 535 Instruction manual

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

INSTRUCTION MANUAL. Handy Polaris

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

CED PRO II. High Precision Electronic Scale Instructions

Reference Only. *B: Bulk packing also available. Inductance. Tolerance M:±20% N:±30% 0.150±25% 1.0 * * N:±30% 0.23±25% 0.8 *2 0.

STREAMLINER M 500 cc Instructions. User Operating Manual

Proline Prosonic Flow 93T Portable

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Electro-hydraulic crimping tool AH-12. Art convincing solutions. Video

OSLON 9 PowerCluster IR

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

Model DS7060 Handrail Scale. User Manual

Extrusion Plastomelter -Standard Operating Procedure [Updated June 30, 2015]

Electro-hydraulic crimping tools SD300-6M / SD400-6M. Art /M / /M. convincing solutions. Video /M Video /M

USER GUIDE KAS-840-DEN KAS-850-RDEN

Instruction Manual. Single-Input Thermistor Thermometer (Model )

AUTOMECH MACHINES & TOOLS TRADING EST.

NIKI T34 pump. Knowing your way around the NIKI T34 pump

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

NOTE: THESE PROCEDURES ARE THE SAME AS BEING IN THE SERVICE MODE. NOTE: ONCE THE UNIT IS POWERED DOWN THE VALUES FOR C4 WILL BE GONE.

How to use the NOx sensor emulator NOXEM

Glastonbury Tap Range Installation Instructions and User Guide

SLA Battery Capacity Analyzer

GLASS LINING TECHNOLOGIES. Bottom Outlet Valves

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

TP Series OWNER S MANUAL. Price Computing Scale (VER.2)

Reference Only. Inductance Frequency (μh) Tolerance Typ Max (MHz min.) 85 *

Lumitester PD-20 Control Kit

Installation and Operational Instructions for EAS -Compact overload clutch, Type 49_. 4._ Sizes 4 and 5

OPERATION & MAINTENANCE INSTRUCTIONS

EASZ-TG11 ULTRASONIC THICKNESS GAGE USER'S MANUAL. Version V1.0 NA

MCF3 25CT Inrush-withstand

Safety instructions. Always... Never... Fire hazard! Dear customer,

Operation Manual LAM 10M IR 3A LASER AIMING MODULE / TARGET POINTER. 105 Sparks Ave., Toronto, ON, M2H 2S5, Canada

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

Superstatic 440. Static Heat- and Cooling Meter. Application

Transcription:

www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk http://www.industrial-needs.com/ Manual Thickness gauge PCE-CT 30

Instruction Manual info@tursdaletechnicalservices.co.uk Coating Thickness gauge SaluTron ComBi D3 Congratulations on the purchase of our coating thickness gauge SaluTron ComBi D3! The gauge belongs to a range of non-destructive coating thickness gauges. It is easy annd handy to use and allows the user to make all the necessary adjustment with the aid of a manue this allows for change to be implemented quickly and simply. The gauge can be used for a wide variety off applications and have a large measur- ring range of 0 to 3,5 mm to offer. Modern electronics and the robust casing guarantee an extended lifetime for the high precision instruments. Attention! Automatic selection of the measurement method magnetic or eddy current. Place the device on Fe-groundmaterial, left on top the display shows Fe. Place the device on NFe-groundmaterial, left on top the display shows NFe. To work with the device without automatic (switch over manual from Fe or NFe) Press the MODE-Key 2 times. It shows GAG on the display. Press ENTER, it shows AUT Auto. Press MODE it shows Fe Auto. Once more press ENTER, it shows Fe and a measuring value. The device is now in the normal manual measuring method. To get into the manual measuring ( Fe ornfe ). method proceed as follow: Press the MODE -Key 2 times, the display shows GAG. Press ENTER, it shows AUT AUTO on the display. Press MODE, it shows Fe AUTO..Press MODE, it shows nfe AUTO. Press the MODE -key 2 times, it shows AUT and then Fe. Press ENTER key, it shows a measuring value. The device is in the measuring mode and ready for measuring applications. Press the MODE -Key 2 times, the display shows GAG. Press ENTER, it shows AUT AUTO on the display. Press MODE, it shows Fe AUTO..Press MODE, it shows nfe AUTO. Press the MODE -key 2 times, it shows AUT and then Fe. Press ENTER key, it shows a measuring value. The device is in the measuring mode and ready for measuring applications. To go back again into the automatic measuring methode ( Fe or nfe ) proceed as follow: Press MODE -key 2 times, it shows GAG on the display. Press ENTER, it shows Fe. or nfe Press MODE -key 2 times it shows AUT. Press ENTER once more, it shows Fe AUTO or nfe AUTO. The device is now in the automatic application. 2

Table of contents Instruction Manual... 2 Attention!... 2 Switch the device on... 4 System overview. SaluTron ComBi D3... 4 Handling and storage... 4 Battery exchange... 5 Zero calibration... 5 Operation... 5 Taking measurements... 5 Switching the gauge ON/OFF:... 6 Using the menu:... 6 Display massages... 6 Delivery... 7 Technical Specifications... 7 3

Switch the device on Automatic display average value Ave and number of measurements n. Switch the device on, the display shows Cd3 or the last measuring value. Press ON/OFF short, the display shows Ave and measuring results (measurements before). Press again ON/OFF, it shows n. N mean the number of measurements.if the store should become deleted proceed as follow: Importand! In the normal measuring application manual or automatic go on like follow: Press MODE, it shows rsl. Press ENTER, it shows no. Press MODE again, it shows YES. Press ENTER, it shows the last measuring value in the normal measurement mode. Now check the store is empty. Press ON/OFF, it shows Ave---. Once more press ON/OFF, it shows n 0. The store is empty. Once more press ON/OFF. The store is empty and the device is in the normal measuring mode back again. Automatic or manual. The store become deleted if the device is in the normal measuring mode. The device is easy to operate. Also the menue on the display makes all addjustments quick, easy and simple. System overview. SaluTron ComBi D3 The coating thickness gauges D3 are simple, costeffective handheld devices (Type ComBi D3 plus: RS 232 interface and memory for data logging purposes). The SaluTron ComBi D3 is built for two applications The gauge SaluTron ComBi D3 - measures all non-magnetic coatings such as synthetics, laquers, enamels, copper, chromium, zinc, etc. on steel or iron. Also the gauge SaluTron ComBi D3 measures all isolating coatings such as laquers, synthetics, enamels, paper, glass, rubber, etc. on copper, aluminium or brass. This includes eloxal coatings on aluminium as well. The SaluTron ComBi D3 gauge posses a CE sign and conform to the following specifications: DIN 50981, 50984 ISO 2178, 2360, 2808 BS 5411 (3, 11) 3900 (c, 5) ASTM B499, D1400 Handling and storage The SaluTron ComBi D3 gauge is a high-tech precision instruments with a wide scope of aplications. It is therefore of great importance that the unit is handled with care to ensure an extended life and as a pre-requisite for precise and accurate measurement results. The following guidelines are to be followed to achieve the above: 1. Protect the gauge against dirt and dust, and do not let the gauge drop! 2. Protect the gauge from dirt, dust, humidity, chemicals and aggressive vapours. 3. After use please store the gauge in the protective case. 4. Avoid direct, strong sunlight and temperature-shocks as these can have a negative influence on the measurement result. 5. The instrument housing is resistant to most chemical cleaners, use a soft, moist cloth for cleaning. 6. Exact measurements can only be taken with a clean probe. The probe therefore has to be checked and cleaned regularly so that any paint residue and iron fragments can be removed from the probe and the ruby tip. 4

7. If the gauge is not to be used for an extended period of time, the battery should be removed to avoid battery acid spilage and the resultant destruction of the electronics. If the gauge has a fault condition, please return it to the agent who will assist you if possible or return the gauge to the factory for repair. No other repairs should be attempted under any circum-stances. Battery exchange The SaluTron ComBi D3 gauge is powered by a 9 V alkaline battery. The battery compartment can be found in the top back portion of the instrument. If a B appears in the display, the battery has to be exchanged. If a replacement battery is not available immediately, several measurements can still be taken until the gauge shuts down (the display shows BAT ) completely. Zero calibration The gauge has to be zeroed anew when different measurement jobs are called for, when the gauge is used for the first time, after a new battery has been inserted or periodically. Place the gauge on the iron plate or the Al-plate in the instrument casa. You can also use a piece of uncoated Fe- or NFe-metal (substrate) as used in your process. Take care to place the probe evenly onto the substrate. If the displayed value is out of the basic tolerance range, the instrument has to be zeroed. The following steps are to be taken to zero the gauge - Remove the gauge from the zero plate or the substrate. - Press the top left button ZERO. The display shows P-O.O - Place the gauge onto the zero plate or the substrate again. The display shows PinF and automatic the last indication. Place on zero plate again. The display shows 0. The unit is now ready for accurate measurements. Note: If the measurement is repeated on the same spot on the zero plate, the gauge will not necessarily show 0.0 my/mils as surface roughness and dirt, etc. can cause differences. Operation Switching the gauge ON: There are two methods to switch the gauge on: 1. The gauge can be switched on manually with the ON/OFF button. The display will show Cd3. 2. The gauge can also be placed on a test piece. It switches on automatically and display also Cd3. It switches automatically off after 40 sec. if no measurement is taken. The gauge is now ready for use. Choose the function: To measure on steel or iron or on non ferrum. Press button Mode. Stop with pressing when shown on the display GAGU. Press Enter. The display shows nfe or Fe. If you like the function Fe press Mode button. The small n for nfe is off. Press Enter button. The display shows - and the last result is shown on the display. Press Zero button and start measuring. Taking measurements - Place the gauge perpendicular onto the surface of the test piece. - Place the probe evenly and ensure that it does not sway. - To get the best results, place the thumb on the position indicated with the other fingers behind the gauge for balance. - A tone is emitted and the result of the measurement is indicated on the display. 5

- If the gauge is removed from the test piece prematurely, or placed incorrectly, or the zero calibration is attempted on the incorrect substrate, then the display will show Erro (error). - If the coating thickness exceeds the maximum range (3500 my) or if the gauge is placed on the incorrect substrate (eg, wood, paper, cardboard, etc), then the display will show InFi (infinite). - For measurements on spinerical surfaces (eg, rods, pipes, corrugated surfaces, etc.) the V groove will assist in the placement of the probe. - Do not take measurements on magnets or in magnetic fields! Switching the gauge ON/OFF: The gauge switches on automatically when being placed on the surface and turns off automatically after about 40 sec. when no other measurement is taken. To switch the gauge manual by hand, press the ON/OFF -key. It shows automatically the last measuring value. The device is ready for new measurement. To switch off the gauge press ON/OFF -key approximately 5 sec. Using the menu: The menu can be used to configure / view the following features: 1. The measurement method single point measurements or continous measurements to find the coating thickness average. 2. The unit for the digital read-out The result can be displayed in my or in mils. (This is indicated by a line next to the respective unit). 3. The audible tone can be switched on/off. 4. The serial number of the particular gauge can be viewed. The menu is accessed by pressing the mode button. Consecutive pressing of the mode button will cause the program to cycle through all the available parameters as mentioned above. If the parameter is to be changed, the Enter button is pressed. Once the desired set-up has been found, the mode button is pressed once again to activate the desired mode. For example, to change the measurement method, the mode button is pressed until the display shows ConT. The Enter button is then pressed to toggle the display between "OFF and ON (OFF = single point measurement, ON = continous measurement). Once the desired mode of operation has been chosen, the mode button is pressed again to activate the measuring-type. Display massages ErO Incorrect usage InF Incorrect substrate, coating thickness out of range B Battery should be replaced soon BAT Battery needs to be replaced now Cd3 Instrument identifier: SaluTron ComBi D3 CnT Continuously measuring- mode to be used when the average coating thickness is to be found by moving the gauge around on the substrate OFF/ By pressing the ENTER -key the ON user can toggle between the point measuring and the continuous measuring modes once the MODE -key has been pressed UnT By pressing the ENTER -key the user can toggle between µm and mils-mode once the MODE -key has been pressed 6

bep Switch the tone ON/OFF for ZERRO, Mode, ENTER, ON/OFF Sn Press ENTER -key. The serial number is blinking GAG Switch over from Fe or NFe. Press ENTER -key. Select Fe or NFe with MODE and ENTER key. AUT Automatic identification of the substrate (iron, steel or non ferrous material) n Number of measurement Ave-- Store is empty AUTO The device switches always automatically to Fe or NFe depending of the groundmaterial Fe or NFe rsc Delete store YES Yes! no No! Measuring Press the MODE -key after every result configuration change with the MODE and ENTER -key to ensure that the gauge is in the standard measuring mode again. Delivery The electronic coating thickness gauge SaluTron ComBi D3 can be used immediately upon delivery. It is delivered with a carrying case, which includes an enclosed zero plates, a 9-volt battery (alkaline) and the instruction manual Option: Gauge D3 plus with RS 232 connection, memory, transfer cable to a PC, statistics-function, Infrared-Mini-Thermoprinter SP 100. Technical Specifications Substrate: Steel or Iron: Non-magnetic metals such as zinc, copper, brass, aluminium, stainless steel: Continous measuring range for both gauges: 0-3500 my or 0-200mils Digital display resulution: from 0.0 999 my Resulution: from 1.00 3.5 mm or from 0.00 140 mils 0.1 my in the range of 0.0 99.9 my 1 my in the range of 100 999 my 0.01 mm in the range of 1.00 3.5 mm Or 0.01 mils in the range of 0.00 9.99 mils 0.1 mils in the range of 10.0 99.9 mils 1.0 mils in the range of 100 140 mils Repeatability: +/- (1my+2%) 0f 0-1000 my 3.5% of 1001-3500 my 7

Tolerance: +/- 1.0 my or +/- 0.06 mils Smallest measurable area: 10 x 10 mm2 (0.4 x 0.4 ) Minimum curvature: convex: 5 mm or 0.02 concave: 30 mm or 1 Minimum substrate: thickness: Fe: 0.20 mm or 8 mils NFe: 0.05 mm or 2 mils Temperature range: Storage: -10 C - +60 C (14 F 140 F) Operation: 0 C - +60 C (32 F 140 F) Probes: Single point Power supply: 9 Volt E block alkaline Dimensions: (LxBxH) 118x58x38 mm Weight: Approx. 150 g with the battery Technical data subject to change without notification In this direction will find a vision of the measurement technique: http://www.industrial-needs.com/measuring-instruments.htm NOTE: "This instrument doesn t have ATEX protection, so it should not be used in potentially explosive atmospheres (powder, flammable gases)." 8