Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

Similar documents
LE Fluorescent Ballast

PC T8 TEC, W PC TEC

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Induction lamps and control gear

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

FL ballasts Electronic fixed output PC T8 PRO, W PC PRO T8

PC T8 PRO, W T8 fluorescent lamps

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Emergency lighting units PC COMBO

Electronic ballasts for fluorescent lamps Professional electronic ballast

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

FL ballasts Electronic fixed output

FL ballasts Electronic fixed output

Emergency lighting units PC COMBO

Most reliable standard, energy-efficient solution

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

TrustSight LED Emergency Lighting

TrustSight LED Emergency Lighting

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Input Current at 240V (A) Max. Input Power (W) Enclosure

Emergency lighting units EM powerled

Commercial product name Power Factor Lamp power Voltage Warm Up Time to 60% Light

EM BASIC V 50/60 Hz

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

HID-PV m PGJ5 20/P CDM LPF

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Philips MASTER LEDtube InstantFit Standard Output 1500mm

Emergency lighting units EM Inverter

Emergency lighting units EM powerled

Input Current at 240V (A) Max. Input Power (W) Dimming Method 1-10V Isolated. Enclosure

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Table of contents. Electronic ballasts for fluorescent lamps Introduction 3

Product Overview. Key Features. (ship.unit) PARATHOM MR ,5 W 2700 K 210 GU mm 50 mm 32 g

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

Switching Power Supplies

QTi 2X28/54/35/49 GII

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Fluorescent and compact fluorescent lamps control gear

Emergency lighting units EM INVERTER

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

ICN2S40N35I Ele Ballast (2) F40T V

Emergency lighting units EM series. EM BASIC, V BASIC version

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

High intensity discharge control gear

lower your cost? Maintain the spilling or NEW! PLS 9/11W replacement PLL 55W replacement Real professionals count on Philips LED PL lamps

LED Driver Linear / area fixed output

Shatterfree fluorescent lighting

LED Driver Compact fixed output

LED Driver Compact fixed output

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

LED control gear Compact fixed output

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet

The Power Behind Energy

Input Current (Amps) Input Power (ANSI Watts)

EcoSystem Multiple Control Input Ballasts

CATALOGUE.

Photo courtesy of Seattle Public Library

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

Input Power (Watts) (min/max)

GB60S 60W Single Output General Purpose Series

Max. Input Power (W) Input Current v 2 2 0v 2 40v. Enclosure

PARATHOM CLASSIC A60 advanced frosted PROMO. Product Overview. Key Features. (ship.unit) E27 60 mm 110

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

EcoSystemR Multiple Control Input Ballasts

Component Systems. for Lighting Applications. January 2018

Reduce Maintenance Costs *

Datasheet. OSRAM SubstiTUBE Trio 2

Safety Standards. Model Number:

Emergency lighting units EM converterled

ST8V 21.5 W/ mm EM

Optanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS:

Input Power (Watts) (min/max)

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

DALI 650mA LED Driver

QTi DALI 1X36/ DIM

Emergency lighting units EM converterled

Emergency lighting units EM converterled

Product Overview. & clear sparkling. Key Features

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Technical information MINI NICOLE, NICOLE & MAXI NICOLE LUMINAIRES

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

Input Power (Watts) (min/max)

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

Max. Input Power (W) Input Current. Inrush 347V Vin 60/ C. 480V Vac Vin 85 / 115. Dimming Method.

Transcription:

Reliability with the most essential intellect Philips HF-Essential Electronic ballasts for TL5 lamps

HF-Essential - Reliability with the most essential intellect Electronic ballasts for TL5 lamps The cost-saving HF-Essential II is an ideal for entry-level product for EM system users who wants to benefit from the advantages provided by electronic ballasts. The reliable design gives optimum performance with all necessary compliance with international standards. Features Energy efficient CELMA A2 CE & Kema compliance Robust design for 45,000 hour lifetime at Ta=50 C and >6,000, average on/off switches on one lamp Warm, flicker-free start (< 1.6 s), no igniter needed High power factor 0.95 with THD < 18% Automatic restart after voltage dip or lamp exchange Suitable for DC emergency operation, 184V to 276V (at 0 C) High frequency operation; eliminating eye strain as caused by electromagnetic ballasts EMC compliant to EN 55015 2006 + A1 2007 Connectors with wire release possibility designed for manual and push-in robot wiring Quality We ensure optimum quality regarding: Product safety: Ballast is protected against excessive mains voltage and a safety stop is automatically activated in case of lamp failure. System supplier: As a manufacturer of both lamps and electronic ballast, Philips ensures that optimum lamp/ballast performance is maintained from the earliest development stage. International standards: Our ballast complies with all relevant international rules and regulations related to safety, energy efficiency, immunity, hazardous substances and EMC. Details can be found in the compliance and approval section. Compliances and approvals RFI 9kHz-30 MHz EN 55015 RFI 30 MHz-300 MHz EN 55015: 2006+A1:2007 RFI when operated on DC EN 55015: 2006+A1:2007 RFI > 30 MHz EN 55022 B Harmonics EN 61000-3-2 Immunity EN 61547 Safety EN 61347-2-3:2000 + A2:2006 Safety when operated on DC Vibration & bump tests IEC 60068-2-6 Fc IEC 60068-2-29 Eb Quality standard ISO 9000-2008 Environmental standard ISO 14001; 2004 CELMA Energy classification EEI=A2 Approval marks KEMA-KEUR CE marking Applications Ideal for entry-level product for EM system users who wants to benefit from the advantages provided by electronic ballasts. Optimized for use in applications where infrequency switching is anticipated Class I fixtures use in office buildings, hospitals, supermarkets, department stores, schools and car parks

Electrical Data and Ballast/ Combinations Type (W) Product Description 12NC Dimensions LxWxH Power System Power Energy Efficiency Index For luminaires with 1 lamp T5 HE 1x14 HF-Essential 114 TL5 220-240V 913713039366 275x19.8x21.3 14W 17W A2 T5 HE 1x21 HF-Essential 121 TL5 220-240V 913713039466 275x19.8x21.3 20W 24W A2 T5 HE 1x28 HF-Essential 128 TL5 220-240V 913713039566 275x19.8x21.3 28W 33W A2 For luminaires with 2 lamps T5 HE 2x14 HF-Essential 214 TL5 220-240V 913713039666 275x30x25.5 28W 33W A2 T5 HE 2x28 HF-Essential 128 TL5 220-240V 913713039766 275x30x25.5 56W 62W A2 For luminaires with 4 lamps T5 HE 4x 14 HF-Essential 414 TL5 220-240V 913713039866 260x40x25.4 56W 64W A2 Technical data for installation Mains operation Rated mains voltage: 220-240 V With tolerances for safety: ±10% 198-264 V Mains frequency: 50/60 Hz Operation frequency: > 42 khz Power factor: 0.95 Earth leakage current: < 0.5 marms per ballast Ignition time: <2.0 sec Overvoltage protection: 2 hrs at 276 V AC, Under voltage protection: 48 hrs at 184 V AC Max cable length hot side: 0.75 m Total wire capacitance between hot and cold lamp wires: Max. 150 pf Total wire capacitance between lamp wires to ground: Max. 150 pf Insulation resistance test from both main inputs to Earth: 500V DC (not between Line and Neutral) Automatic restart after lamp replacement: Yes Tested with a dip down to: 30% DC/Emergency operation Nominal light output is obtained at DC voltage: Required battery voltage for guaranteed ignition: Required battery voltage for burning lamps: DC switchover time: 220-240 V 198-276 V 184-276 V 180-200 ms

Dimensions in mm (nom) Installation Instructions Temperatures Temperature range to ignite lamp with ignition aid 0 ºC to +50 ºC Max. Tcase 75 ºC Failure rate 0.33% per 1000 hrs at 75 ºC Type A1 A2 B1 C1 D1 HF-E 114 TL5 275 265 19.8 21.3 4.2 HF-E 121 TL5 275 265 19.8 21.3 4.2 HF-E 128 TL5 275 265 19.8 21.3 4.2 HF-E 214 TL5 275 265 30 25.5 4.2 HF-E 228 TL5 275 265 30 25.5 4.2 HF-E 414 TL5 260 250 40 25.4 4.2 Lifetime of a ballast depends on the temperature of the ballast. This means there is a relation between the Tc point on the ballast and its lifetime. The HF- E ballast has a specified lifetime of 30.000 hrs, with a maximum of 10% failures guaranteed, at a measured Tcase of 75ºC. For more information regarding this subject consult the Philips Application guide to fluorescent lamp control gear. Wiring Recommendations The lead length is dependent on the capacitance of the cable. Earthing is not required for the device to operate. Connection to earth reduces radio interference. With standard solid wire 0.5/0.75 mm2 the capacitance of the lead is approx. 200 pf/m. This value is influenced by the way the wiring is made. In borderline cases the capacitance must be measured inside the luminary. Keep lamp wires short. connection with twin ballast should be made with symmetrical wiring. Max cable length hot side 0.75 m Hot leads and cold leads should be separated as much as possible. To avoid the damage of the control gear, the wiring must be protected against short circuits to earth. Wiring type and cross section The wiring can be in flexible cable with ferrules or solid cable with a cross section of 0.5 1.5 mm². For perfect function of the simple to use push-wire terminals the strip length should be 8 9 mm. WAGO 250

Wiring Diagram