PRO ACID System Service / Site : QUAL / France Référence : 0016 Version : V.04.0 Date version : 07/07/2014 Page : 1/9 USER GUIDE
500 1700 244 Pro ACID System - Installation 140 75 E A Filter gasket 3 wall plugs S7 3 S/st screws 5,5x38 Water pressure 2 to 6 bars WATER B Fiber gasket D Quick coupler F C 2 wall plugs S7 2 S/st screws 5,5x38 2 rondelles L6 inox. 160 IMPORTANT! Ajuster! la longueur du tuyau d aspiration Adjust the pour lenght que of la hose crépine to the yellow repose filter that verticalement rest upright sur le on fond the du bottom bidon 150 OPTION S/st can holder. (5L) These installation dimensions are indicative Les cotes d installation (en mm) sont données à titre indicatif FILTER MONTAGE GASKET DU JOINT ASSEMBLY FILTRE IMPORTANT! Respect the gasket orientation FIBER MONTAGE GASKET DU JOINT ASSEMBLY FIBRE Fiber gasket Adaptator Coupler MONTAGE BLUE RING DU COUPLEUR QUICK COUPLER RAPIDE A MONTAGE DILUTION DES TIP BUSES BAGUE ASSEMBLY BLEUE DE ASSEMBLY DILUTION A B C D Check valve Tip Hose Outillage Needed nécessaire tools : 1 drill : 1 forêt Ø 7mm Ø 7mm and 1 et screw 1 tournevis driver cruciforme 1_PULV ACIDE Sy stem (PVC) 1_Bag w ith connection kit = 1_Suction line (cry stal hose) L:2,5m 1_Inlet hose of w ater (L: 2m) Ø12/19mm 1_Ø12/19mm Discharge hose, 10, 15 or 25m according to model 1_Stainless steel lance no-scratch L: 60 or 120cm according to model 1_Instruction sheet Coupler Blue ring Hose insertion Clamping ring PACKING LIST OF THE PULV ACIDE SYSTEM E WAND ASSEMBLY Handle Nut + gasket Wand 1_Yellow filter w ith w eight. 1_Bag of 15 tips 1_Nipple for quick coupler M-F3/4" 1_Quick coupler ring blue 1_Quick coupler ring red 1_Bag w ith screw s and gaskets1 Rubber gasket blue 3/4" 1_Green fiber gasket 3/4" 3 S/st screw s. Ø5,5x 37 3 w all plugs S7 PERÇAGE HOLE OF THE DES BOUCHONS TAPE F 1 trou Ø10mm NTPUASLB V.04.0 p.6/9
NTPUASLB V.04.0 p.7/9 Pro ACID System - Use A Water pressure 2 to 6 bars Maximum temperature working= 20 C CLOSE B OPEN Safety rules S36/37/39 Wear protection coat Wear protection gloves Wear protection glasses and mask USE 1 Open the valve inlet water «A» 2 Press the lever «B» handle spraying. 3 Wait a few seconds the rise of production in the suction line. 4 Close the inlet vale «A» after use. CAUTION ALWAYS orientate spray in direction of surfaces to treat. NEVER orientate spray in direction of people, animals or plants ALWAYS w ait few seconds for a good product and w ater mix ing. ALWAYS close w ater inlet v alv e after each use. WATER PRESSURE must be included on 2 bar to 6 bar. MAXIMUM w orking temperature is 50 C ALWAYS keep the unit on frost protection TABLEAU DE DILUTION PULV ACIDE Couleur Produit Couleur Produit Pink 0,5% Blue 9,4% Purple 1,3% White 10,4% Turquoise 1,5% Red 12,6% Dark brow n 2,2% Beige 15,3% Yellow 2,6% Black 16,4% Orange 3,8% Grey 16,6% Green 5,8% Without tip 17,0% Light brow n 7% Incolore Bouchon This table is done to help you to choose a tip according to expected concentration METHOD OF DILUTION CALCUL EXEMPLE: 15 (A) x 100%= 1.5% 1000 (B) (This drawing is an exemple) Volume A (15 cl ou 150 ml) Volume B (1000 cl ou 10 000 ml) CONDITIONS DES TESTS Dynamic water pressure = 2,5 bars 25m hose 60cm et 120 cm wand Volume A : breathed product Volume B : solution (water + breathed product)
NTPUASLB V.04.0 p.8/9 Pro ACID - Troubles Water pressure 2 bars to 6 bars Maximum temperature working: 20 C Check valve cleaning Spring Ceramical ball O ring MAINTENANCE? PULV ACIDE system does not aspire product. 1 Check the pressure of the water system (minimum : 2 bar, max : 6 bar) 2 Check that the filter gasket is not dirty or scaled. (clean or 3 Check that the yellow filter of the suction line is submerged in the product, and the hose is not pinched, folded, or closed. 4 Verify that the tip is not clogged. (clean or 5 Check that the yellow filter of the suction line is not dirty. (clean or 6 Check that the spray handle is not dirty or calcified. (clean or 7 Check that the flat spray nozzle is not dirty or calcified. (clean or? The product can filled with water.. 8 Verify that the check valve is not dirty or calcified. (clean or Spray nozzle cleaning Nut of lance Gasket Flat spray nozzle Nozzle holder
NTPUASLB V.04.0 p.9/9 1 2 19 16 Pro ACID- Description 3 Water pressure 2 bars to 6 bars WATER 9 10 11 12 13 14 7 8 18 4 5 6 17 15 Safety rules S36/37/39 Wear protection coat 20 Wear protection gloves Wear protection glasses and mask PULV ACIDE system is intended for the determination and application of shampoo for automobile bodies. ACCESSORIES AND SPARE PARTS PULV ACIDE Designation Repère Back plate PULV ACIDE - White PVC 1 Personnal logo 2 Hose connection Ø12/19 - Lg 2m - Green 3 Fiber gasket 3/4" black (bag of 10) 4 Nipple for quick coupler 3/4" 5 Brass quick coupler blue 6 Stop vlave 7 Venturi assembly PVDF 8 Dilution tips (bag of 15) 9 Check valve White/Yellow (gasket FPM) 10 S/st screw M5x45 (x2) 11 Hose blocker (PVDF) 12 Hose connection nut 13 Suction line Lg: 2m (Cristal hose Ø 6/9) 14 Yellow filter with weight 15 Spray handle with quick coupler 16 PVC wand no-scratch. Lg: 60 or 120 cm (depend of version) 17 Blue discharge hose Ø12/19 PVC. 10,15, or 25m (depend of version) 18 Filter gasket 3/4" black (bag of 5) 19 Spray nozzle (60-9,8L/mn) 20 spray nozzle holder 20