Auxiliary Relay. Type CV2

Similar documents
Auxiliary Relay. Type RXP8n, RXPQ8n

Auxiliary Relay. Type P8n, PQ8n, PN8n

Bistable Relay. Types PSU6n, PSU14n.

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

Integrated water management solutions

Bistable Relay. Types PSU6n, PSU14n. Station Automation & Protection. ABB Substation Automation Products

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Distribution transformers Efficiency over life-cycle

Reverse power relay and protection assemblies

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Multi-purpose percentage restraint differential protection

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

MEDIUM VOLTAGE SWITCHGEAR

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Functions provided by measuring relays in railway equipment

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Quality Products, Prompt Service, Trustful Relationships.

Motor Protection Circuit Breaker

Publication No.: PSG

Inductive Proximity Sensor

Outdoor vacuum breaker for railway applications - FSK II

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Catalog. Low voltage General performance IE3 efficiency cast iron motors

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Technical Information

OUTDOOR OFF LOAD DISCONNECTORS HCB/HDB Range

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

Inductive Proximity Sensor

3TM Vacuum Contactors

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Type DTH 31, 32 DTTM 11, 12 High Speed Biased Differential Relays

The most widely used motors from the world leaders

Indoor Metal Clad Switchgear Type:Cubicle VHA 36 SF6 Circuit Breaker HPA 36 Rated Voltage: ABB Power Distribution

Breaker failure relay REB 010

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Metal Clad VCBs ~ Mk1

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

AF series contactors (9 2650)

Flame Proof Motors For Hazardous Environment JHX

Current accuracy class. Sensor principles

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Inductive Proximity Sensor

Technical Information

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

LA Motor Protection. A South African Company to be Proud of

Essential equipment for all your requirements

6R MATRIX. Modular Relays. rms. Auxiliary, Trip & Supervision Relays

C1000 Series Automatic Cap Bank

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

AF series contactors (9 2650)

RAPIER DSB Disconnectors

Surface mounting, flush mounting, and DIN track mounting

CI-TI Contactors and motor starters Types CI 61 - CI 98

Series CA5 Contactors

Unitole UP kv Primary substations Motor control centres

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Unitole UP kv Primary substations Motor control centres

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

PIX-H Metal-clad switchgear up to 17.5kV

The contactor for large horsepower applications

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

ML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A

UMBW-UL489 and UL1077 Listed

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

EMPAC Metal enclosed capacitor bank for wind applications

About us. Switchgear Factory, Mumbai

CP Automatic capacitor bank

Industrial contactors CTX-1

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Programmable Logic Controller. Mat Nor Mohamad

RESIDUAL CURRENT CIRCUIT BREAKER

Contactor V-Contact VSC/P

Motor Protection Circuit Breakers

F-Series. Circuit Breaker

TECHNICAL DESCRIPTION

JOSLYN CLARK VACUUM CONTACTOR FEATURES

F-Series. Circuit Breaker

Powering business worldwide

Motor-drive mechanism, type BUL. Technical guide

Low & Medium Voltage Vacuum Contactors

SD Series Non-Fused Load Switches

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

Transcription:

Auxiliary Relay Type CV2

ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering environmental impact. The ABB Group of companies operates in around 100 countries and employs over 1,07,000 people. In India, ABB serves customers with the complete range of power and automation technologies. The company has a vast installed base, extensive manufacturing facilities and a countrywide marketing and service presence. As a part of its Power Technologies offering, ABB serves electric, gas and water utilities as well as industrial and commercial customers with a wide range of products, systems and services for power generation, transmission and distribution. ABB s system offering ranges from Electrical Balance of Plant (EBOP) for power plants, bulk power transmission, turnkey substations and complete electrification to utility automation and power distribution. The product offering covers a wide spectrum of technologies across the entire voltage range including indoor and outdoor circuit breakers, air and gas insulated switchgear, disconnectors, capacitor banks, reactive power compensators, power transformers, distribution transformers, instrument transformers, Compact Secondary Substations (CSS) and Ring Main Units (RMU). Advantage ABB 120 years of technology and innovation Unparalleled domain competence Global experience Complete solution capabilities Large installed base Environment-friendly technologies 2 ABB

Auxiliary Relay Features Small size High degree of reliability, even when it has been idle for a long time Mechanical operation indicator High contact rating 2 or 4 contacts with double interruption Three mounting variants Wide range of voltage and low power consumption Application The indicating relay type CV2 is intended for use in control and protective systems in industrial plants and power stations, where it is mainly used in conjunction with electronic control systems, particularly where a visual indication of a given function is required. Design & Principle The indicating relay type CV2 is an instantaneous hinged-armature relay with two contacts. These may be either two normally open contacts, or one normally open and one normally closed. (Two normally closed contacts cannot be supplied.) The magnetic system comprises the fixed core and the hinged-armature which actuates the contacts. When the coil is de-energised, the armature is reset to its original position by a spring. When the relay picks up, an indicating knob pops out. When the relay is in its normal state, prior to pick-up the knob is black, but when it picks up, there appears an orange ring. The indicator can be reset simply by pressing the knob back in. Separate relays can be supplied without hood for incorporation in other equipment. For pairs of relays various modes of mounting are possible as shown below. Type designation of auxiliary relays: CV2 A D H RM M RN N J 2J Basic auxiliary relay for AC Voltage for DC Voltage with single element without protective cover with single element mounted on sheet-metal base with double element mounted on sheet-metal base with single element mounted on plug-in base with double element mounted on plug-in base with single element mounted in1/2 S size, flush mounting case with double element mounted in 1/2 S size, flush mounting case Available types: CV2AJ, CV2DJ CV2DRM, CV2DRN, CV2DH, CV2A2J, CV2D2J CV2DM, CV2DN Technical data Rated voltage (U N ) 24,30, 48, 110,220, 250 DC 24,30,48,110,240 AC (with Rectifier) available only in 1/2S size mounting case Operating range + 10% to - 20% of U N Frequency 50 Hz +/-5% Pick-up voltage (%U N ) < 75% Drop-off voltage (%U N ) >15% Pick-up time at U N (typical) 20-35ms Maximum power consumption DC 3W AC 2.5 VA Insulation tests Dielectric test 2kV, 50Hz, 1min. as per IEC 60255-5 Impulse voltage test 5kV, 1.2/50micro sec. 0.5J., as per IEC 60255-5 Insulation resistance >100 M ohms at 500V dc. as per IEC 60255-5 Mechanical life Switching rate 1x 10 6 switching operations. as per IEC60255-6 Up to 1000 operations per hour at full breaking current, or 3600 times per hour with reduced breaking current

Contacts Rated voltage Rated current Max. making current 250V DC/AC 10 A 30 A Max. Breaking capacities Voltage 24-60 V 110V 125 V 220V Contacts 1 2 in 1 2 in 1 2 in 1 2 in Series Series Series Series DC resistive load 16A 20A 8A 15A 6A 15A 1.1A 6A DC inductive. L/R =15ms 7.5A 10A 3A 10A 2.5A 8A 0.8A 3.5A AC 50Hz resistive 20A - 20A - 20A - 20A - AC 50Hz inductive 20A - 20A - 20A - 20A - (Cosf =0.3) Environment tests Dry heat test IEC 60068-2-2 +55 o C and +70 o C Dry cold test IEC 60068-2-1-10 o C and -25 o C Damp heat cyclic test IEC 60068-2-30 12hrs+12hrs cycle at+55 o C/+25 o C with RH98% for 6 days Storage test IEC 60068-2-8 +70 o C for 72 hrs and -25 o C for 72 hrs. Vibrations test Vibration response Endurance test IEC 60255-21-1 Class-1 10-150Hz, 0.5g, 3 axis IEC 60255-21-1 Class-1 10-150Hz, 1.0g, 3 axis Electromagnetic compatibility requirements High frequency disturbance test IEC 60255-22-1 1MHz 2.5kV common mode, and 1kV differential mode Weight Type...N : 0.69 kg. approx. Type...M : 0.68 kg. approx. Type...2J : 0.85 kg. approx. Ordering details Relay type Auxiliary Voltage Contacts configuration

Connection diagram and contact configuration Fig.1 Relay with one element on plug-in base, on sheet-metal base or in 1/2 S case mounting. Fig.2- Relay with two elements on plug-in base, on sheet-metal base or in 1/2 S case mounting. Fig.3- Relay for ac voltage with one element in 1/2 S case mounting. Fig.4- Relay for ac voltage with two elements in 1/2 S case mounting.

Dimensions Fig. 5- Plug-in base mounting Fig.6-1/2 S case mounting. Fig. 7- Sheet-metal base mounting. Legend Aa : Terminals Db : Mounting hole E01 : Cut-out for rear wiring. * : Space for removing hood. Ls : Operation signal Ob : Fixing screw

Ordering details Refer type designation for selection and mark ( ) appropriate boxes Type : CV2DRM Qty... Item no... CV2DM Qty... Item no... CV2DH Qty... Item no... Aux Voltage : 24VDC Contacts 2N/O + 0N/C 30VDC 1N/O + 1N/C 48VDC 4N/O + 0N/C 110VDC 2N/O + 2N/C 220VDC 3N/O + 1N/C 250VDC Type : CV2DRN Qty... Item no... CV2DN Qty... Item no... Aux Voltage : 24VDC Contacts 2N/O + 0N/C 30VDC 1N/O + 1N/C 48VDC 4N/O + 0N/C 110VDC 2N/O + 2N/C 220VDC 3N/O + 1N/C Type : CV2DJ Qty... Item no... CV2AJ Qty... Item no... CV2D2J Qty... Item no... CV2A2J Qty... Item no... Aux Voltage : 24VDC Contacts 2N/O + 0N/C 30VDC 1N/O + 1N/C 48VDC 4N/O + 0N/C 110VDC 2N/O + 2N/C 220VDC 3N/O + 1N/C 250VDC 24VAC 30VAC 48VAC 110VAC 240VAC

1MDB08201 -YN 08- ABB Limited Distribution Automation Maneja, Vadodara 390 013, India. Tel: +91 265 2604384/5/6 +91 265 2604397 Fax:+91 265 2638922 E-mail: aicds@in.abb.com Regional Marketing Offices: North No.14, Mathura Road P.O. Amar Nagar Faridabad 121 003 Tel: +91 129 2275592, 2279627, 5049000 Fax: +91 129 2279692/5019 West ABB House Dr. S B Path Ballard Estate Mumbai 400 038 Tel: +91 22 56318231 39 Fax: +91 22 56318276/77 South Embassy Star, 1st Floor No. 8, Palace Road Vasanth Nagar Bangalore 560 052 Tel: +91 80 22949779 Fax: +91 80 22949808 www.abb.co.in East 4th Floor No. 9 Elgin Road Kolkata 700 020 Tel: +91 33 22832906/8 Fax: +91 33 22832990 Central 4th & 5th Floor, Maruti Heights Aamanaka, G E Road, Raipur 492 099 Tel: +91 771 4701016 Century Plaza No. 3C, 3D & 3F, 3rd Floor 561 / 562, Anna Salai Teynampet (Mount Road) Chennai 600 018 Tel: +91 44 24340201 Fax: +91 44 24340282