UNIT FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET

Similar documents
PANEL FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET

PANEL FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET

INSTRUCTION AND USE MANUAL

CONTROL AND PROTECTION PANEL FOR TRACTOR-PUMP CTR-087/0N THE TRACTOR/PUMP IS STOPPED WHEN THERE ARE ANOMALIES (VIA ELECTROMAGNET) CONCERNING:

CONTROL UNITS FOR IRRIGATION MOTOR PUMPS AND PUMP WATER PRESSURE CONTROL

Type CIM-131. ELCOS SRL - Parma - GB - CIM-131 1

Fire Fighting Diesel Pump Control Panel in Compliance with EN Standard User Manual

DIESEL-EN - User Manual

USER INSTRUCTIONS FOR SLIDING DOORS

FIREPAK-E21 & FIREPAK-ED21

SPEEDRIVE INSTRUCTIONS MANUAL

AUE-AUD-AU2E AU2D-AUED

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

PSM72H Push-Button Start Module

ECONOMISER SERIES E2T USER MANUAL

PUR (A, B, C, D) INSTRUCTION FOR VARIABLE SPEED WITH WIRING DIAGRAM FOR EMX P10 ROTOR SIZE

CONTROL, PROTECTION AND VISUALIZATION ELECTRONIC MANUAL CEN- TRALITE FOR GENERATING SETS CMD2.0

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

SAFETY- FLY 700 P USER MANUAL FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR MIT

ENGINE PROTECTION BOARD PDM1

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Level Measuring Sensor for Diesel Fuel Tanks

IGLOO IGLOO EASY INSTRUCTION MANUAL

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

TITANO 400V SLIDING GATE OPENER

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

DEEP SEA ELECTRONICS PLC

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

P445 Series Electronic Lube Oil Control

DIESEL Engine Fire Pump Controllers Features

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Controller Specification Sheet

ELECTRIC AND ELECTRONIC ACCESSORIES. motralec

DKG-114 MANUAL AND REMOTE START UNIT

E Series CE Approved Intermittent Pilot Ignition Control

DEEP SEA ELECTRONICS PLC

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

MAINTENANCE AND USER MANUAL

PowerView PV380-R2 Mechanical Configuration

The measurements module provides the following engine features information:

GL1200T Cut & Seal. (GL1200 Seal only)

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Nortoft Electronic A/S Sejrupvej 38 Sejrup DK-7323 Give Denmark

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

SIZING OF SOLAR GENERATOR

GCU-10. Automatic Engine Control Unit Operators Manual

Operating manual UPS - System

DEEP SEA ELECTRONICS PLC

PRO series programmer

USE AND MAINTENANCE MANUAL AQUA IONIC PLUS. Aqua Ionic Plus MAN00016 Rev. B / 22

Red #22 Power. Red #14. Brown #18. Ign/Acc/Start. White#14. Tachometer Foot-Brake Door Pin Pos Trunk/Hatch (open) (-) while running Lock Arm

Automatic concealed bollards 275 H600 and 275 H800 Control station

PULSE-8: MASTER PULSATION CONTROL

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

GENERALITIES TECHNICAL FEATURES

OS3050 OS3051. Controller for reverse osmosis plants. Instruction manual. Softwareversion 3.04

USER MANUAL AND INSTALLATION GUIDE ENGINE RPM AND NOS SHIFT COUNTER NOS DELAY TIME IN SECONDS NOS START PERCENT NOS FINAL PERCENT

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

STANDARD OWNER S MANUAL

Mod: KLD6-12/35XLAS-N

Installation and Operation

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

Operating Instructions

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating instructions Flow monitors SI5000 SI / / 2007

SDM72 Start on Demand Modules

Pump controller and protection for one pump Multicontrol. +info: INSTALLATION AND OPERATION. Mod. Vigilec mini (V1N)

POLE STAR PRO. Installation and instruction manual.

Electrical operating instructions

2 PORT MOTORISED VALVE (28 mm)

Operating Instructions

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

Ex m Solenoid Operator Type 0519

KONGSKILDE KONNECT 1000

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

INSTALLATION GUIDE Table of Contents

Flight Systems. Replacement for KASSEC DESCRIPTION

VW7 INSTALL GUIDE OL-BLADE-AL(DL)-VW7-EN. Alarms & Remote Start Automotive Data Solutions Inc.

Wireless Radiator Valve

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

Sieve Shaker 200mm/300mm - 8/12 inch SV003

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

MAGNETIC MOTOR STARTERS

Two Channel Remote Shutdown Device

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Safety Valve HM-SV Installation, maintenance and startup guide

MG300 USER GUIDE. Ver. 3.2 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MG300.4, MG300.6, MGV30.4 AND MGV30.6

Three-Phase Soft Starters

Tina 4A Connection block

Stratomaster Maxi Single

Instruction, Use and Maintenance Manual CONTROL UNITS J-GIOTTO TOP

Safety Sensor CSS 180 Product Information

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

EC200 ELECTRONIC CONTROL SYSTEM

Transcription:

UNIT FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET INSTRUCTION AND USER MANUAL TYPE CIM-50/0 By simply starting, it automatically controls the motor pump Pump water electronic pressure switch Digital pump water pressure gauge Assembly also on the machine and in the open air. MOUNTING AT PANEL MADE TO: PROTECT motor pump sets by stopping them in the event of: low oil pressure over-temperature belt breakage minimum fuel level low coolant level low pump water pressure pump water overpressure A available low fuel pressure DISPLAY on the panel the functions of: hour-meter oil pressure gauge water or oil thermometer tachometer pump water pressure gauge timer fuel level gauge pump protection exclusion battery and oil lights protections intervention emergency stop PARMA ITALY Tel. +9 05/770 Fax +9 05/708 GB CIM-50/0 E-mail: info@elcos.it - HTTP://www.elcos.it

PUMP WATER PRESSURE IS DISPLAYED A AVAILABLE BRIEF INSTRUCTIONS After starting, the motor pump protects itself automatically ENGINE OIL PRESSURE IS DISPLAYED ENGINE WATER OR OIL TEMPERATURE IS DISPLAYED MOTOR PUMP OPERATING SPEED IS DISPLAYED PRESS TO SELECT THE DISPLAYED FUNCTION, EACH TIME IT IS PRESSED, THE INSTRUMENT INDICATED BY THE DISPLAY CHANGES. PRESS IF YOU WANT TO SET WORKING TIME ( UP TO 96 HOURS) THE FUEL LEVEL IS DISPLAYED ACCUMULATED OPERATION HOURS ARE DISPLAYED PRESS TO ADJUST WATER PUMP ELECTRONIC PRESSURE SWITCH EMERGENCY STOP STOP % STOP h! M A C RPM P CUMULATIVE ALARM LOW FUEL PRESSURE PRESS UNTIL THE SIGNS START FLASHING TO EXCLUDE PUMP PROTECTION. TO RE-ACTIVATE PROTECTION, PRESS AGAIN UNTIL THEY SWITCH OFF. WATER PRESSURE IS REGULAR ENGINE PROTECTIONS ARE ACTIVE PUMP PROTECTION IS ACTIVE THE BATTERY IS NOT CHARGING LOW ENGINE OIL PRESSURE 0 AUT. AVV. STOPPAGE DUE TO LOW FUEL LEVEL STOPPAGE DUE TO INSUFFICIENT ENGINE OIL PRESSURE STOPPAGE DUE TO LOW COOLANT LEVEL STOPPAGE DUE TO LACK OF BATTERY CHARGING (BELT BREAKAGE) STOPPAGE DUE TO HIGH ENGINE TEMPERATURE STOPPAGE DUE TO LOW PRESSURE OR PUMP WATER OVERPRESSURE OR ELECTRONIC PRESSURE GAUGE (TRANSMITTER) INTERRUPTED. IN THIS CASE, THE ANOMALY IS HIGHLIGHTED BY THE FLASHING WARNING LIGHT. LOW PRESS. OVERPRESS. DISCONN'ED 0 AUT. AVV. START KEY - OFF - STOPPAGE IN ALL OPERATING CONDITIONS - RESTORE PROTECTIONS, CANCEL PUMP PROTECTION EXCLUSION AND TIMER, DEACTIVATE INSTRUMENTS. - CONTROL UNIT SUPPLY - TURNS ALL THE LIGHTS ON FOR SECONDS ( EFFICIENCY CHECK ) - PRESSURE SWITCH ADJUSTING (SEE PAGE ) - MOTOR PUMP START UP GB CIM-50/0

ADJUSTING THE PUMP WATER ELECTRONIC PRESSURE GAUGE (TRANSMITTER) It controls the pressure of the system, replacing the conventional pressure switch. PUMP PROTECTION No adjusting is required P The protection of the pump is enabled when the PUMP PROTECTION ACTIVE information comes on, after the water pressure has been steady for consecutive minutes and in any case after 0 minutes from starting of the engine. Intervention of the protection occurs 5 seconds after the pressure goes up or down by two bars, stops the engine and is shown on the display: OVERPRESS. Pump water overpressure or INSUFF. LOW PRESS. Low pressure (low pressure) It is possibile to change the two bars of the pressure lowering (low pressure) by using the key This change is cancelled when the engine stops. OVERPRESSURE remains set to two bars, this value is added to the working pressure (for example, working pressure 9 bar overpressure bar) WORKING PRESSURE TIMER Enabled with key on AUT, it makes it possible, if necessary, to have the motor pump work for an adjustable length of time (96 hours maximum), at the end of which it stops and the WORK TIME OVER sign lights up on the display. STOP Press to adjust the value of low pressure (PRESSOSTAT) PRESSOSTAT 7 The work time is set by pressing the push-button ( lights up) until the desired value appears on the DISPLAY. Press to select the pump water pressure gauge On releasing the push-button, the timer automatically starts working, continously displaying the remaining work time. CANCELLING THE SET TIME To zeroing the set time there are two methods: - keep the push-button pressed until it reaches zero. - by turning the starter key onto "ZERO" (the engine pump will stop). PUMP PROTECTION EXCLUSION (ENABLED ONLY WITH ENGINE RUNNING) The push-button excludes pump protection: - exclusion is obtained by keeping it pressed for at least consecutive seconds; the function is indicated by the two intermittent lights. - this exclusion is cancelled by pressing the push-button, again or by turning the start key onto "ZERO". OIL AND BATTERY INDICATOR LIGHTS Lit up with key on "AUT", they switch off with the engine running and regular oil pressure and battery charge system. ENGINE PROTECTIONS The engine protections are enabled when the ENGINE PROTECTIONS ACTIVE light M comes on (0 seconds after the end of starting impulse and however minute after positioning the key on AUT ). Interventions of the protection probes (fitted on the engine), indicated by the relevant lights, stop the engine, they are memorised and can be split into two groups. Delayed by seconds for: Delayed by 5 seconds for: - OIL PRESSURE SWITCH - OVERTEMPERATURE SWITCH - A - BATTERY CHARGE ALTERNATOR (ALTERNATOR BELT BREAKAGE) - FUEL LEVEL SWITCH - Fuel reserve flashing signal: 0% fuel reserve (T) (WITHOUT ENGINE STOP) - Signal always on: stop for minimum fuel level (W) - PROBE FOR COOLANT LEVEL - LOW FUEL PRESSURE GB CIM-50/0

FOR RADIATORS WITH PLASTIC EXPANSION TANK INSTALLING THE CONTROL UNIT COOLANT LEVEL PROBE FOR RADIATORS WITH METAL EXPANSION TANK 55 SCREW ELECTRODES 55 ROD ELECTRODE WARNING! IF THE FUNCTION - LOW COOLING LIQUID LEVEL IS NOT USED: CONNECT / ORANGE WIRE TO EARTH / ORANGE D TO REPLACE THE FUSES, REMOVE THE COVER FROM THE CONTROL UNIT /4 GAS /8 GAS PUMP WATER PRESSURE TRANSMITTER CABLE The control unit has been designed to control stopping with an ELECTROMAGNET SET UP WATER OR OIL THERMOMETER OIL PRESSURE GAUGE CONNECTION OF EMERGENCY BUTTON 4 4 BEFORE CONNECTING THE EMERGENCY BUTTON REMOVE THE CONNECTOR WITH THE JUMPERS BLACK/VIOLET 4 C BLUE/BROWN B CONNECTOR C STOP SYSTEM SET UP To stop with the SOLENOID VALVE cut and isolate the BLUE/BROWN lead To view the water/oil THERMOMETER and the oil pressure GAUGE, connect the transmitters to the respective wires of the control unit, then CUT and isolate the BLACK/VIOLET wire STOP SYSTEMS EXCITED IN STOP MODE WARNING! : IT IS NOT POSSIBLE TO MOUNT THE EMERGENCY STOP BUTTON ONASTOP SYSTEM WITH ELECTRO- MAGNETS 85 0 86 87 EXCITED WHILE RUNNING 85 0 86 87 SOLENOID to close the fuel 7 Run the engine at a costant and known rpm value (for example by means of a portable revolution counter) 4 RPM TACHOMETER ADJUSTMENT ELECTROMAGNET to activate the engine stop lever Select the instrument TACHOMETER, keep the button depressed for at least 5 seconds and simultaneously press increase or decrease until the correct reading appears on the display. Release the buttons and wait until OK appears on the display. GB CIM-50/0

55 6/8 INSTALLING THE CONTROL UNIT WIRING DIAGRAM TO CONNECT THE EMERGENCY BUTTON FROM 5/54 OF START KEY, see page 4 (connector C) A MAX USABLE FOR HEADLIGHT OR AUXILIARIES CONNECTOR CONNECTOR /ORANGE 0 CONNECTOR 9 8 7 D 6 5 4 6 5 4 GREY WHITE/RED GREEN BROWN (ONLY FOR PERMANENT MAG.) WHITE /7 SKY-BLUE 4 + BATTERY A MAX 97 4 BLACK/BLUE 8 ORANGE/BROWN A 9 WHITE/VIOLET WHITE/GREEN 40A MAX BLACK 0 RED 50 ORANGE 8 40 ORANGE/ BLUE T INDICATOR W RESERVE A MAX 7 57 RED/GREEN CABLE,5m INSULATE POSSIBLE CABLES NOT CONNECTED STOP SYSTEMS SEE PAGE 4 CHARGE BATTERY ALTERNATOR: PRE-EXCITATION DO NOT USE PERMANENT MAGNETS RED 6 8 7 7 CONNECTION SYSTEM FOR EXTRACTING THE W TERMINAL IN PRE-EXCITATION BATTERY CHARGE ALTERNATORS. R W B+ D+ + LE G R G L + B C WHITE/RED + BATTERY GREEN BROWN WHITE/RED + BATTERY GREEN BROWN TO TACHOMETER (WHITE/RED WIRE) ACCESSORIES AVAILABLE ON REQUEST (/7) ELECTROMAGNET OR SOLENOID VALVE () OIL PRESSURE SWITCH (4) THERMOSTAT (8) FUEL FLOAT FOR INDICATORAND RESERVE (97) OIL PRESSURE TRANSMITTER () TEMPERATURE TRANSMITTER (55) COOLANT LEVEL PROBE (7) PUMP WATER PRESSURE TRANSMITTER (SUPPLIED) (6) PERMANENT MAGNETS CHARGEALTERNATOR (7) BATTERY CHARGEALTERNATOR REGULATOR (8) PRE-EXCITATION CHARGEALTERNATOR (40) STARTING MOTOR (4) BATTERY (57) GENERALALARM LIGHT (9) AAVAILABLE FOR PROTECTION PROBE (8) FUEL PRESSURE SENSOR SELECT LANGUAGE The language set up is ITALIAN; the languages that can be selected are: ENGLISH, FRENCH, GERMAN, SPANISH and PORTUGUESE. ON Move DIP ON Move DIP switch to ON switch to OFF (BOSCH, MARELLI, LUCAS, ECC...) To diode bridge (inside alternator) } ITALIANO Press to select the desired language ENGLISH Press and wait for OK to be written GB CIM-50/0 5

OPERATION CONTROLLING THE CONNECTION OF THE PUMP WATER ELECTRONIC PRESSURE GAUGE (Transmitter) Turning the key to the AUT position stops the electronic pressure gauge. Control is activated minute after the completion of the starting pulse. Intervention is highlighted by the relevant indicators and stops the motor pump after seconds. DISCONN'ED flashing warning light To exclude intervention, press the push-button PUMP PROTECTION EXCLUSION. PUMP PROTECTION The pump protection is enabled with the switching on of the ACTIVE PUMP PROTECTION (after minutes of stable water pressure, indicated by the visual signal REGULAR PUMP PRESSURE case, 0 minutes after the start of the motor pump). consecutive and, in any The intervention of the protection (5 seconds after the increase or decrease of the pressure) stops the engine and is indicated by the visual signal for LOW PUMP WATER PRESSURE or WATER PUMP OVERPRESSURE. RESET: is obtained by turning the start key onto "ZERO". STOPPING THE ENGINE PUMP The control unit shuts down the engine in four conditions: - turning the starter key onto "ZERO - protection intervention - timer intervention at the end of the work period - through intervention of the external emergency. The unit adapts to two different stop systems - by working the ELECTROMAGNET for 0 seconds which pulls the STOP lever - by cutting off power to the SOLENOID VALVE shutting off the flow of fuel. GENERAL ALARM This can be obtained by fitting on the outside an optical and/or acoustic signaller to be connected to the RED/GREEN wire. It is activated on protection intervention. EMERGENCY STOP It can be obtained in all functioning conditions, mounting one or more release-type buttons. It is indicated by the visual signal! and enables the general alarm. INSTRUMENT SELECTION The control unit comprises six instruments: h HOUR METER - Total hours of operation (with the engine running the signal pulsates, to indicate the correct functioning of the HOUR-METER). INSTRUMENTS WHICH CAN BE SELECTED IN SEQUENCE BY PRESSING THE BUTTON Each time it is pressed, IT SHOWS the next instrument. WHEN THE TIMER IS set, the duration of the display of the instrument is limited to 0 seconds from the activating of the button; the TIMER then reappears. bar C RMP % 6 - PRESSURE GAUGE - Engine oil pressure - THERMOMETER - Engine oil and water temperature - TACHOMETER - Speed of motor pump - PRESSURE GAUGE - Pump water pressure - INDICATOR - Fuel level percentage } TRANSMITTERS FITTED ON ENGINE ON REQUEST GB CIM-50/0

S.r.l. Via Arandora Star, 8/a-4 PARMA ITALIA Tel. +9 05/770 Fax +9 05/708 E-mail: info@elcos.it HTTP://www.elcos.it UNIT FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET TYPE CIM-50/0 Only for starting and surveillance of the diesel motor pump and stops it if there are anomalies in the parts controlled by probes. It has been designed to be installed also on the machine. NOTICES! Warning: adhere closely to the following advice: - Always install under other equipment which produces or spreads heat. - Always follow the Wiring Diagram on pages 4-5 when making connections. - Check that the line loading and the consumption of the connected equipment are compatible with the technical characteristics on page 8. - All technical interventions must be performed with the engine stationary and terminal 50 of the starter motor disconnected. - Never use a battery charger for the emergency start-up, this could damage the control unit. - To protect the safety of persons and the equipment, before connecting an external battery charger, disconnect the electrical plant terminals from the battery poles. - Never disconnect the battery terminals with the engine running. THIS CONTROL UNIT IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING CONDITIONS: - Where the environmental temperature is outside the limits indicated in the Technical Data on page 8. - Where there are high levels or heat from radiation caused by the sun, ovens or the like. - Where there is the risk of fire or explosions. - Where the panel can receive strong vibrations or knocks. ELECTROMAGNETIC COMPATIBILITY This control unit functions correctly only if inserted in plants which conform with the CE marking standards; it meets the exemption requirements of the standard EN66- but it cannot be excluded that malfunctions could occur in extreme cases due to particular situations. The installer has the task of checking that the disturbance levels are within the requirements of the standards. CONDUCTION AND MAINTENANCE The following maintenance operations should be performed every week: - check that the indicators function; - check the batteries; - check that the conductors are tight, check the condition of the terminals. UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY, THIS CONTROL UNIT IS NOT SUITABLE FOR USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE FOR KEEPING PERSONS OR OTHER LIVING BEINGS ALIVE YOUR ELECTRICAL TECHNICIAN CAN ASK US ANYTHING ABOUT THIS CONTROL UNIT BY TELEPHONING ONE OF OUR TECHNICIANS GB CIM-50/0 7

DIMENSIONS TECHNICAL DATA 84 8,5 m 88 7 D 88 PANEL HOLE B A 00 0mm C 9 86 - BATTERY VOLTAGE SUPPLY Vdc 4 Vdc - VOLTAGE SUPPLY 8 V - CIRCUIT LOADING WITH KEY AT ZERO maat V 9mAat4V - MAX LOAD OF THE OUTPUT: -( STOPPING) A -( STARTING MOTOR) BLACK 40A -( GENERALALARM) RED/GREEN A -( AUXILIARY) BROWN A - TEMPERATURE RANGE -0 +60 C - HOUR-METER 4 DIGITS - OIL PRESSURE GAUGE 0 7 bar - PUMP WATER PRESSURE GAUGE 0 bar - PUMP WATER PRESSURE TRANSMITTER: ALLOWED MAX. PRESSURE bar - ENGINE OIL/WATER THERMOMETER +0 +45 C - TACHOMETER 4000 rpm - TIMER ' 96 h - INSTALLATION CONDITIONS FOR EXTERNAL USE - DEGREE OF PROTECTION: BOX/CONNECTOR IP54/IP0 - CONTROL UNIT WEIGHT,5 Kg - TOTAL WEIGHT, Kg ( CONTROL UNIT + ACCESSORIES + PACKAGE) 7 ORDERING DATA ACCESSORIES KIT - PRE - WIRED FEMALE TYPE CIM-50/0 CODE 008 CONNECTOR CEM-50-56/0 CODE 7080440 - EMERGENCY BRIDGE CONNECTOR CODE 708044 - PUMP WATER PRESSURE TRANSMITTER TYPE TPA-00 NIPPLE F/4" GAS -M/8 GAS CODE 405005 - NUTS KIT CODE 4079906 CONFORMITY DECLARATION The company Elcos s.r.l. assumes full responsibility for declaring that the control unit: Type CIM-50/0 installed and used in the ways and for the purposes described in the user instruction manual complies with the essential requirements and other relevant provisions laid down by the following directives: - 004/08/CE related to the electromagnetic compatibility and that repeals the directive 89/6/CEE, - 0/65/UE on the restriction of the use of certain hazardous substances in electrical and electronic equipment, because it is built and functions in accordance with the harmonized Standards: EN66-, EN66/A, EN6000-4-, EN6000-4-4, EN6000-4-6, EN6059. Parma,06/04/04 President S.r.l. Via Arandora Star, 8/a I 4 PARMA ITALIA Tel. +9 05/770 Fax +9 05/708 E-mail: info@elcos.it - HTTP://www.elcos.it Margini Enzo 8 GB CIM-50/0