Compact Lifts 1 Jan 09 Global Lift Equipment Ltd Unit s 40-4 3 A shm o unt Ente rp ri se P a rk, Flint, Flint shire, C H6 5YL. Tel: 01352 735400 Fax: 01352 735733 Email:sales@global-lift.com Web: www.global- lift.com
Compact Lifts CONTENTS Page 1-2 GLE/Compact 36/1 Technical Data Page 3 Plan of Lift Shaft Page 4-8 General Arrangement Draw ings Page 9-10 GLE/Compact 36/2 Technical Data Page 11 Plan of Lift Shaft Page 12-16 General Arrangement Draw ings Page 17-18 GLE/Compact 42/1 Technical Data Page 19 Plan of Lift Shaft Page 20-24 General Arrangement Draw ings Page 25-26 GLE/Compact 42/2 Technical Data Page 27 Plan of Lift Shaft Page 28-32 General Arrangement Draw ings Page 33 Finishes Plastic Laminate & Skinplate Page 34 Stainless Steel Page 35 Linoleum & Dotted Rubber Page 36-38 Schedule Of Materials All 4 Lifts Page 39 Guide Fixing Detail Typical Draw ing For All 4 Lifts
GLE/Compact Range 36/1 LIFT TECHNICAL DATA: PAYLOAD: 225 Kg. SPEED: 0.5mps TRAVEL: 3.2 mtrs per floor (Note! Floor to floor height cannot be less than 2.5 mtrs. As this is minimum height for landing door equipment) PLUNGER POSITION: INDIRECT SIDE ACTING 2:1 STOPS/DOORS: 2-5 FRONT ONLY CONTROLLER TYPE: F.A.P.B. DOORS TYPE: FOUR PANEL CENTRE PARTING POWER OPERATED DOORS, VF DRIVE MACHINE ROOM POSITION: ADJACENT TO HOISTWAY LIFT RULE: EN 81.2 95/16/EC - HOISTWAY DIMENSION: WIDTH 1054 mm. DEPTH 1124 mm. MINIMUM HEADROOM: 3290 mm. MINIMUM PIT: 1075 mm.(en81 requirement) DESCRIPTION OF MATERIALS: Lift car guide rails with fishplates and bolts. Full height supporting RSA steels. 2.5 metre length guides. Adjustable guide rail brackets. Clamping bolts to fix guide rails to the brackets. 2:1 cantilev ered carf rame with guide shoes, instantaneous safety device, lift carf ixings, lubricators, sole plate with rope f ixings, steel buffer supports, piston fixing brackets, buffers. Slack rope dev ice with test dev ice (as per EN 81.2 lift rules - art. 9.10.4 ). Steel sheet lift car, 904 wide x 700 deep x 2150 mm., built in self supporting Skinplate panels - (choice of colour ), one entrance, power operatedf our panel center parting doors 600x2000 mm., matching colour Skinplate. VF door operator, f ull height door detector, car station with stainless steel face plate mounted on side wall. Linoleum f loor covering, direct lighting, emergency light recessed in the car station panel. Hy draulic pump unit with Blainv alve, start delta start, supply 415 V. Hy draulic piston with rupturev alve. (one piece). (Option for split ram) Accessories: 6 m. Flexible 1 ¼ hy draulic hose. 4 off hosef ixing brackets. Traction rope. Flex. cables andf ixing brackets under the car, in the hoistway. Car top maintenance box. Microprocessor controller, F.A.P.B., with motor protection, phase relay, f loor lev el indication (powered by battery - As per EN 81.2 art. 12.9.3), alarm bell and battery, upward re-lev eling of lift car (as per EN 81.2 lift rules art. 14.2.1.5 ). Complete hoistway set of switches and electronic sensors. DMG Tactile car and landing push buttons with call acceptance illumination. Stainless steel f aceplates. All f ixtures mounted at low lev el as per Part M Building regulations and EN81-70. IN THE CAR: Floor, door open and alarm buttons. Autodialler. Overload audio/v isual Indicator. Digital position indicator. ON THE LANDINGS: Call button with call acceptance illumination. Digital position indicator at mainf loor. Power operated f our panel centre parting landing doors 600x2000 mm., as per EN 81, single skinned door panels, epoxy grey RAL 7012. Ov erload dev ice by means of pressure limit switch. Saf ety rail on car top Pit safety switch Machine room temperature sensor Alarm button on car top. Pit prop and hy draulic oil included 1
GLE/Compact Range 36/1 ADDITIONAL OPTIONS: Split Piston Stainless steel car door Stainless steel landing entrance (per entrance) Plastic laminate car interior Digital position indicator ( per unit) Folding seat Automatic descent and door open (This feature requires loss of mains (switched off) and the integrity of the safety circuit maintained.) Whilst the existing shaft and car sizes prevent complete conformity to DDA requirements, the following options are other requirements to satisfy EN81-70, and will ensure compliance with the (DDA) Disability Discrimination Act in all other respects. Full height door detector Half height saf ety mirror to rear of car Raised head exit floor button in the car Handrail with turned ends Green pictogram to the COP indicating alarm operation Yellow pictogram to the COP indicating alarm receiv ed Arriv al gong Next direction of trav el arrows (extra cost per floor) Comf ort tone (at each push button, car and landing) Voice synthesizer 2
PLAN OF LIFT SHAFT GLE/Compact Range 36/1 3
GLE/Compact Range 36/2 LIFT TECHNICAL DATA: PAYLOAD: 225Kg. SPEED: 0.5 mps TRAVEL: 3.2 mtrs per floor (Note! Floor to floor height cannot be less than 2.5 mtrs. As this is minimum height f or landing door equipment) PLUNGER POSITION: INDIRECT SIDE ACTING 2:1 STOPS/DOORS: 2-5 FRONT ONLY CONTROLLER TYPE: F.A.P.B. DOORS TYPE: TWO PANEL SIDE OPENING POWER OPERATED DOOR,VF DRIVE MACHINE ROOM POSITION: ADJACENT TO HOISTWAY LIFT RULE: EN 81.2 95/16/EC HOISTWAY DIMENSION: WIDTH 1054 mm. DEPTH 1054 mm. MINIMUM HEADROOM: 3290 mm. MINIMUM PIT: 1075 mm. (legal requirement) DESCRIPTION OF MATERIALS: Lift car guide rails with fishplates and bolts. Full height supporting RSA steels. 2.5 metre length guides. Adjustable guide rail brackets. Clamping bolts to fix guide rails to the brackets. 2:1 cantilev ered carf rame with guide shoes, instantaneous safety device, lift carf ixings, lubricators, sole plate with rope f ixings, steel buffer supports, piston fixing brackets, buffers. Slack rope dev ice with test dev ice (as per EN 81.2 lift rules - art. 9.10.4 ). Steel sheet lift car, 690 wide x 860 deep x 2150 mm., built in self supporting Skinplate panels - (choice of colour ), one entrance, power operated two panel side opening doors 600 x 2000 mm., matching colour Skinplate. VF door operator, f ull height door detector, car station with stainless steel face plate mounted on side wall. Linoleum f loor covering, direct lighting, emergency light recessed in the car station panel. Hy draulic pump unit with Blainv alve, start delta start, supply 415 V Hy draulic piston with rupturev alve. (one piece). (Option for split ram) Accessories: 6 m. f lexible hydraulic hose 1"1/4.. 4 off hosef ixing brackets. Traction Rope Flex. cables andf ixing brackets under the car, in the hoistway. Car top maintenance box. Microprocessor controller, F.A.P.B., with motor protection, phase relay, floor level indication (powered by battery - as per EN 81.2 art. 12.9.3), alarm bell and battery, upward re-lev eling of lift car (as per EN 81.2 lift rules art. 14.2.1.5 ). Complete hoistway set of switches and electronic sensors. DMG Tactile car and landing push buttons with call acceptance illumination. Stainless steel faceplates. All f ixtures mounted at low level as per Part M Building regulations and EN81-70. IN THE CAR: Floor, door open and alarm buttons. Autodialler. Overload audio/v isual Indicator. Digital position indicator. ON THE LANDINGS: Call button with call acceptance illumination. Digital position indicator at mainf loor. Power operated two panel side opening landing doors 600x2000 mm., as per EN 81, single skinned door panels, epoxy - grey RAL 7012. Ov erload dev ice by means of pressure limit switch. Safety rail on car top Pit safety switch Machine room temperature sensor Alarm button on car top Pit prop and hydraulic oil included 9
GLE/Compact Range 36/2 ADDITIONAL OPTIONS : Split piston Stainless steel car door Stainless steel landing entrance (per entrance) Plastic laminate car interior Digital position indicator ( per unit) Folding seat Automatic descent and door open (This f eature requires loss of mains (switched off) and the integrity of the saf ety circuit maintained.) Whilst the existing shaft and car sizes prevent complete conformity to DDA requirements, the following options are other requirements to satisfy EN81-70, and will ensure compliance with the (DDA) Disability Discrimination Act in all other respects. Full height door detector Half height saf ety mirror to rear of car Raised head exit floor button in the car Handrail with turned ends Green pictogram to the COP indicating alarm operation Yellow pictogram to the COP indicating alarm receiv ed Arriv al gong Next direction of trav el arrows (extra cost per floor) Comf ort tone (at each push button, car and landing) Voice synthesizer 10
GLE/Compact Range 36/2 PLAN OF LIFT SHAFT 11
GLE/Compact Range 42/1 LIFT TECHNICAL DATA: PAYLOAD: 400Kg. SPEED: 0.5 mps TRAVEL: 3.2 mtrs per floor ((Note! Floor to floor height cannot be less than 2.5 mtrs. As this is minimum height f or landing door equipment) PLUNGER POSITION: INDIRECT SIDE ACTING 2:1 STOPS/DOORS: 2-5 FRONT ONLY CONTROLLER TYPE: F.A.P.B. DOORS TYPE: THREE SPEED SIDE OPENING POWER OPERATED DOORS, WITH VF DRIVE MACHINE ROOM POSITION: ADJACENT TO HOISTWAY LIFT RULE: EN 81.2 95/16/EC - HOISTWAY DIMENSION: WIDTH 1270 mm. DEPTH 1450 mm. MINIMUM HEADROOM: 3290 mm. MINIMUM PIT: 1075 mm. (legal requirement) DESCRIPTION OF MATERIALS: Lift car guide rails with fishplates and bolts. Full height supporting RSA steels. 2.5 meter length guides. Adjustable guide rail brackets. Clamping bolts to fix guide rails to the brackets. 2:1 cantilev ered carf rame ty pe 01.1200.65. with guide shoes, instantaneous saf ety dev ice, lift car fixings, lubricators, sole plate with ropef ixings, steel buffer supports, piston fixing brackets, buffers. Slack rope dev ice with test dev ice (as per EN 81.2 lift rules - art. 9.10.4 ). Steel sheet lift car, 1120 wide x 995 deep x 2150 mm., built in self supporting Skinplate panels - (choice of colour), one entrance, power operated three speed side opening doors 800x2000 mm., matching colour Skinplate. VF door operator, f ull height door detector, car station with stainless steel face plate mounted on side wall. Linoleum f loor covering, direct lighting, emergency light recessed in the car station panel. Hy draulic pump unit with Blainv alve, start delta start, supply 415 V. Hy draulic piston with rupturev alve. (one piece). (Option for split ram) Accessories: 6 m. Flexible 1 ¼ hy draulic hose 4 off hosef ixing brackets. Traction rope Flex. cables andf ixing brackets under the car, in the hoistway. Car top maintenance box. Microprocessor controller, F.A.P.B., with motor protection, phase relay, f loor lev el indication ( powered by battery - as per EN 81.2 art. 12.9.3), alarm bell and battery, upward re-lev eling of lift car (as per EN 81.2 lift rules art. 14.2.1.5 ). Complete hoistway set of switches and electronic sensors. DMG Tactile car and landing push buttons with call acceptance illumination. Stainless steel faceplates. All f ixtures mounted at low level as per Part M Building regulations and EN81-70. IN THE CAR: Floor, door open and alarm buttons. Autodialler. Overload audio/v isual Indicator. Digital position indicator. ON THE LANDINGS: Call button with call acceptance illumination. Digital position indicator at mainf loor. Power operated three speed landing doors 800x2000 mm., as per EN 81, single skinned door panels, epoxy-grey RAL 7012. Ov erload dev ice by means of pressure limit switch. Saf ety rail on car top Pit safety switch Machine room temperature sensor Alarm button on car top Pit prop and hy draulic oil included 17
GLE/Compact Range 42/1 ADDITIONAL OPTIONS: Split piston. Stainless steel car door Stainless steel landing entrance (per entrance) Plastic laminate car interior Digital position indicator ( per unit) Folding seat Automatic descent and door open (This f eature requires loss of mains (switched off) and the integrity of the saf ety circuit maintained.) Whilst the existing shaft and car sizes prevent complete conformity to DDA requirements, the following options are other requirements to satisfy EN81-70, and will ensure compliance with the (DDA) Disability Discrimination Act in all other respects. Full height door detector Half height saf ety mirror to rear of car Raised head exit floor button in the car Handrail with turned ends Green pictogram to the COP indicating alarm operation Yellow pictogram to the COP indicating alarm receiv ed Arriv al gong Next direction of trav el arrows (extra cost per floor) Comf ort tone (at each push button, car and landing) Voice synthesizer 18
GLE/Compact Range 42/1 PLAN OF LIFT SHAFT 19
GLE/Compact Range 42/2 LIFT TECHNICAL DATA: PAYLOAD: 400Kg. SPEED: 0.5mps TRAVEL: 3.2 mtrs per floor ((Note! Floor to floor height cannot be less than 2.5 mtrs. As this is minimum height f or landing door equipment) PLUNGER POSITION: INDIRECT SIDE ACTING 2:1 STOPS/DOORS: 2-5 FRONT ONLY CONTROLLER TYPE: F.A.P.B. DOORS TYPE: THREE SPEED SIDE OPENING POWER OPERATED, VF DRIVE MACHINE ROOM POSITION: ADJACENT TO HOISTWAY LIFT RULE: EN 81.2 95/16/EC -------------------------------------------------------------------------------------------------------------------------- HOISTWAY DIMENSION: WIDTH 1372 mm. DEPTH 1250 mm. MINIMUM HEADROOM: 3290 mm. MINIMUM PIT: 1075 mm. (Legal requirement) DESCRIPTION OF MATERIALS: Lift car guide rails with fishplates and bolts. Full height supporting RSA steels. 2.5 metre length guides. Adjustable guide rail brackets. Clamping bolts to fix guide rails to the brackets. 2:1 cantilev ered carf rame with guide shoes, instantaneous safety device, lift carf ixings, lubricators, sole plate with rope f ixings, steel buffer supports, plungerf ixing brackets, buffers. Slack rope dev ice with test dev ice (as per EN 81.2 lift rules - art. 9.10.4 ). Steel sheet lift car, 1007 wide x 1020 deep x 2150 mm., built in self supporting Skinplate panels - (choice of colour ), one entrance, power operated three speed side opening doors 800x2000 mm., matching colour Skinplate. VF door operator, f ull height door detector, car station with stainless steel face plate mounted on side wall. Linoleum f loor covering, direct lighting, emergency light recessed in the car station panel. Hy draulic pump unit with Blainv alve, start delta start, supply 415 V. Hy draulic piston with rupturev alve (one piece). (Option for split ram) Accessories: 6 m. Flexible 1 ¼ hy draulic hose. 4 off hosef ixing brackets. Traction rope. Flex. cables andf ixing brackets under the car, in the hoistway. Car top maintenance box. Microprocessor controller, F.A.P.B., with motor protection, phase relay, f loor lev el indication (powered by battery - as per EN 81.2 art. 12.9.3), alarm bell and battery, upward re-leveling of lift car (as per EN 81.2 lift rules art. 14.2.1.5 ). Complete hoistway set of switches and electronic sensors. Full height door detector. DMG Tactile car and landing push buttons with call acceptance illumination. Stainless steel faceplates. All f ixtures mounted at low level as per Part M Building regulations and EN81-70. IN THE CAR: Floor, door open and alarm buttons. Autodialler. Overload audio/v isual Indicator. Digital position indicator ON THE LANDINGS: Call button with call acceptance illumination. Digital position Power operated three speed landing doors 800x2000 mm., as per EN 81, single skinned door panels, epoxy-grey RAL 7012. Ov erload dev ice by means of pressure limit switch. Saf ety rail on car top Pit safety switch Machine room temperature sensor Alarm button on car top Pit prop and hy draulic oil included 25
GLE/Compact Range 42/2 ADDITIONAL OPTIONS : Split piston Stainless steel car door Stainless steel landing entrance (per entrance) Plastic laminate car interior Digital position indicator ( per unit) Folding seat Automatic descent and door open (This f eature requires loss of mains (switched off) and the integrity of the saf ety circuit maintained.) Whilst the existing shaft and car sizes prevent complete conformity to DDA requirements, the following options are other requirements to satisfy EN81-70, and will ensure compliance with the (DDA) Disability Discrimination Act in all other respects. Full height door detector Half height saf ety mirror to rear of car Raised head exit floor button in the car Handrail with turned ends Green pictogram to the COP indicating alarm operation Yellow pictogram to the COP indicating alarm receiv ed Arriv al gong Next direction of trav el arrows (extra cost per floor) Comf ort tone (at each push button, car and landing) Voice synthesizer 26
GLE/Compact Range 42/2 PLAN OF LIFT SHAFT 27
Compact Lift - Finishes PLASTIC LAMINATE SKINPLATE (PLALAM) 33
Compact Lift - Finishes STAINLESS STEEL 34
Compact Lift - Finishes LINOLEUM DOTTED RUBBER 35
Schedule Of Materials DESCRIPTION 42/1 42/2 36/1 36/2 GUIDE RAILS Car Guide Rails T 89/B T 89/B T 89/B T 89/B Fishplates and bolts & screws Included Included Included Included GUIDE RAIL BRACKETS Car guide rail bracketry assembly Included Included Included Included RSA supporting steels Included Included Included Included CLAMPING BOLTS Clamping bolts assembly with Included Included Included Included screws Ribbed and flat shims Included Included Included Included RAM HEAD PULLEY Ram Head Pulley Included Included Included Included CAR FRAME 2:1 rope car frame equip. With Included Included Included Included instantaneous saf ety dev ice Car buffers Cellasto 5C Cellasto 5C Cellasto 5C Cellasto 5C Pit Prop w/out contact Included Included Included Included Galv anized rope anchors and rope Suitable f or diam.9 Suitable f or diam.9 Suitable f or diam.9 Suitable f or diam.9 clamps mm. mm mm mm CAR CAGE BASIC BASIC BASIC BASIC Car construction type Self -supporting Self -supporting Self -supporting Self supporting Car dimensions 1032wx1020dx2150h 1120wx1020dx2150h 714wx860dx2150h 904wx724dx2150h Rear and side walls Front Return Panel Skinplate (PLALAM) Skinplate. P8, or colour as the walls Skinplate (PLALAM) Skinplate. P8, or colour as the walls Skinplate (PLALAM) Skinplate. P8, or colour as the walls Skinplate (PLALAM) Skinplate. P8, or colour as the walls Skirting Skinplate. P8, or colour as the walls Skinplate. P8, or colour as the walls Skinplate. P8, or colour as the walls Skinplate. P8, or colour as the walls Ceiling White painted White painted White painted White painted Lighting Surf ace mounted f luorescent Surf ace mounted f luorescent Surf ace mounted f luorescent Surf ace mounted f luorescent Flooring type Fixed Fixed Fixed Fixed Floor f inishes PVC - V3 PVC - V3 PVC - V3 PVC - V3 Car Operation Panel Stainless steel Stainless steel Stainless steel Stainless steel Full Height Door Detector Included Included Included Included Car Natural ventilation EN81 EN81 EN81 EN81 Car sill support Included Included Included Included Car apron EN 81 Included Included Included Included Car door panels Epoxy - grey Epoxy - grey Epoxy - grey Epoxy grey PUMP UNIT Valv e unit Blain Blain Blain Blain Ty pe of oil BP Energol Hlphm46 BP Energol Hlphm46 BP Energol Hlphm46 BP Energol Hlphm46 TRACTION ROPES Traction Rope - Seale 152, dia. 9 mm N 4 lengths - inc. N 4 lengths - inc. N 4 lengths - inc. N 4 length - inc. 36
Schedule Of Materials DESCRIPTION 42/1 42/2 36/1 36/2 TRAILING CABLES Flat trailing. Cable 16x0.75 h05vvh6f 2 lengths 2 lengths 2 lengths 2 lengths +g/v Pre-wired car top inspection box Included Included Included Included CONTROL PANEL APB APB APB APB Basic Controller type Down collectiv e Down collectiv e Down collectiv e Down collectiv e Door operator type VVVF4 VVVF4 VVVF4 VVVF4 Car loading system Display f ull / over Display f ull / over Display f ull / over Display f ull / over load load load load Car and GF landing position Digital Digital Digital Digital Call accepted signal Car /landings Car/landings Car/landings Car/landings Door open/close buttons Included Included Included Included ALARM button Included Included Included Included 2-way Intercom Car/Controller Car/Controller Car/Controller Car/Controller EMC f ilter Included Included Included Included Plug-in ty pe pre-wiring Included Included Included Included HOISTWAY INFORMATION Proximity switches/limits Included Included Included Included Singalling encoders PLR PLR PLR PLR PUSH BUTTON UNITS Standard COP Stainless steel Stainless steel Stainless steel Stainless steel Push buttons f or Car Call accepted + alarm + door open/ close Car Call accepted + alarm + door open/ close Car Call accepted + alarm + door open/close Car Call accepted + alarm + door open/ close Basic push button type Series BL Series BL Series BL Series BL Acoustic andv isual Overload Included Included Included Included Emergency lamp Included/IncorporatedIncluded/Incorporated Included/ Incorporated Included/ Incorporated Handf ree phone Included Included Included Included Plug-in pre-wiring Included Included Included Included LOWEST LANDING (GF) PUSH BUTTON UNIT Ty pe, st/steel plate - dim. 100 mm St/steel S.B: St/steel S.B. St/steel S.B: St/steel S.B. INTERMEDIATE LANDING PUSH BUTTON UNIT Ty pe, st/steel plate - dim. 100 mm St/steel S.B: St/steel S.B. St/steel S.B. St/steel S.B. HIGHEST LANDING PUSH BUTTON UNIT Ty pe, st/steel plate - dim. 100 mm St/steel S.B. St/steel S.B. St/steel S.B. St/steel S.B. AUTODI ALLER Handsf ree, car, car top and pit. Included Included Included Included 37
Schedule Of Materials DESCRIPTION 42/1 42/2 36/1 36/2 AUTOMATIC DOORS 3PSO 800mm 3PSO 800mm 2PSO 600mm 4PCP 600mm Door Operator VVVF3 VVVF3 VVVF3 VVVF3 Apron acc. To EN81 + sill support Included Included Included Included Main landing landing door with Epoxy - grey Epoxy - grey Epoxy - grey Epoxy - grey panels Door f ixing ty pe C Included Included Included Included Other f loors landing door with Epoxy - grey Epoxy - grey Epoxy - grey Epoxy - grey panels Door f ixing ty pe C Included Included Included Included Emergency key Included (1) Included (1) Included (1) Included (1) ELECTRICAL WIRING MATL. Plug-in pre-wiring Included Included Included Included Pit switch Included Included Included Included TECHNICAL LITERATURE Installation, Operation and Maintenance Manual (acc. To 95/16CE) TEST ty pe Certif icate (acc. To EN 81/99-95/16CE) Included Included Included Included Included Included Included Included 38
Compact Lifts For further details on any of the above items, contact our Sales Department at the office below GLE reserve the right to modify any product detail/specification contained within this publication without prior notice. Global Lift Equipment Ltd Unit s 40-4 3 A shm o unt Ente rp ri se P a rk, Flint, Flint shire, C H6 5YL. Tel: 01352 735400 Fax: 01352 735733 Email:sales@global-lift.com Web: www.global- lift.com