Wind Power Inverter WINDY BOY 5000A/6000A

Similar documents
PV inverter SUNNY MINI CENTRAL 7000HV

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

System Monitoring SCHOOLMETERBOX AU

System Description SMA FLEXIBLE STORAGE SYSTEM in the United Kingdom

Operating parameters WINDY BOY

Wind Power Inverter WINDY BOY 1100LV

Wind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US. 1 Notes on this addendum. 1.1 Validity. 1.2 Target group

PV Inverter SUNNY BOY 3300/3800

Wind Power Inverter WINDY BOY 1200/1700

Multi-Function Interface MULTI-FUNCTION RELAY

Accessories for power generation plants in Italy SMA GRID GATE

Version: 1.0 Mat.-Nr.: DBUS-WB50-80US

PV Inverter SUNNY BOY 3300/3800

PV inverter SUNNY BOY 2100TL

Charge controller SUNNY ISLAND CHARGER

Operating Parameters SUNNY BOY / SUNNY MINI CENTRAL

System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function

User Manual SMA FUEL SAVE CONTROLLER 2.0

KeContact P20. User manual

YSmart Technology Co., Ltd. User Manual. GTI Grid Series. GTI Series Inverters for Grid-connected PV system

Wind Power Inverter WINDY BOY 3600TL / 5000TL

User Manual SMA FUEL SAVE CONTROLLER 2.0

Operating Manual SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H SUNNY REMOTE CONTROL. SI30M-44M-60H-80H-BE-en-33 Version 3.3 SUNNY REMOTE CONTROL

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Operating Parameters SUNNY BOY/SUNNY MINI CENTRAL/WINDY BOY

Installation - Quick Reference Guide Off-Grid Systems

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

Operating Manual NA-BOX 12

Important instructions

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

DC Master 24/ A

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

System Description SMA FLEXIBLE STORAGE SYSTEM with BatteryBackup Function

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER

Grant Grid-Connected Inverter For Grant Solar PV Systems. Installation & User Instructions

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Operating manual UPS - System

Assembly and Maintenance Manual Type ASNU

Oil-free piston compressors KK and piston vacuum pumps KV

Installation Manual SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/ 760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

PSU1 Power Supply Unit

OPERATING MANUAL. Wind / Solar Hybrid - Charge Controller 24V 1000w. i/hcc Charge Controller

Assembly and Maintenance Manual Type AS

SMA Export Control Solution

Operating manual. Custom made gearboxes

Mod: KLD6-12/35XLAS-N

Swing Piston Compressors and Vacuum Pumps

7 MODES OF OPERATION INVERTER STATUS Standby: The PV string can only provide just enough voltage to minimum requirements of the controller.

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Sunny Tripower. Can do everything that we can

Galaxy Receiving and Unpacking 09/

Technical Manual Electrical Power Supply System T4002

Operating Instructions. bluesmart Active

Micro Inverter with Communication Unit SUNNY BOY 240-US SUNNY MULTIGATE-US

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

Planning Guidelines SMA SMART HOME The System Solution for Greater Independence

Operating Manual SUNNY BOY 3600 / 5000 SMART ENERGY BATTERY PACK SMART ENERGY

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Simple and secure monitoring

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

Certificate of Conformity self-generation unit

Assembly and Maintenance Manual Type RSBW

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Sinewave Inverters. SWING 150VA and 300VA. User s manual

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Service Manual for Installers SUNNY TRIPOWER 5000TL/6000TL/7000TL/8000TL/9000TL/ 10000TL/12000TL

Exchange of rollers from the XTS-Mover

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Operation of a CDP in SPLIT-PHASE installations

SUNNY BOY 2000HF / 2500HF / 3000HF

Installation Instructions

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

MICRO-INVERTER OMNIKSOL M-300

Battery Charger. Series EASY Charger. User s manual

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Certificate of Conformity self-generation unit

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation Manual Retrofitting of the Option "Noise Reduction" SUNNY CENTRAL of the CP XT Series and SUNNY CENTRAL STORAGE

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions

Bosch Smart Home. Door/Window Contact Instruction Manual

Pure Sine Wave Inverter 600W-24V User Manual

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Technical Information PV Inverters

BMW i. Freude am Fahren. BMW i Wallbox Plus. Owner's manual

Original Operating Manual

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

I. Safety precautions

Transcription:

Wind Power Inverter WINDY BOY 5000A/6000A User Manual WB5A-6A-BA-BEN114530 TBEN-WB50-60A Version 3.0 EN

SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Manual......................... 5 1.1 Validity............................................ 5 1.2 Target Group....................................... 5 1.3 Additional Information................................ 5 1.4 Symbols Used....................................... 6 2 Safety.......................................... 7 2.1 Intended Use........................................ 7 2.2 Safety Instructions.................................... 8 2.3 Explanation of Symbols............................... 9 2.3.1 Symbols on the Inverter...........................................9 2.3.2 Symbols on the Type Label...................................... 10 3 Product Overview............................... 11 4 Display........................................ 12 4.1 Operation......................................... 12 4.2 Display Messages during Operation.................... 12 4.3 Display Messages during a Disturbance................. 13 4.4 DC Overvoltage.................................... 13 5 LED Signals..................................... 14 6 Visual Inspection, Maintenance and Cleaning........ 16 7 Troubleshooting................................. 17 7.1 Status Messages.................................... 17 7.2 Measurement Channels.............................. 18 8 Glossary....................................... 19 9 Contact........................................ 20 User Manual WB5A-6A-BA-BEN114530 3

Table of Contents SMA Solar Technology AG 4 WB5A-6A-BA-BEN114530 User Manual

SMA Solar Technology AG Information on this Manual 1 Information on this Manual 1.1 Validity This manual applies to the following device types: WB 5000A WB 5000A-11 WB 5000A-IT WB 6000A WB 6000A-11 WB 6000A-IT 1.2 Target Group This manual is intended for the operator. 1.3 Additional Information You will find additional information on the device-specific technical data in the installation manual provided. You will find additional information on special subjects (e.g. description of the operating parameters) in the download area at www.sma.de/en. User Manual WB5A-6A-BA-BEN114530 5

Information on this Manual SMA Solar Technology AG 1.4 Symbols Used The following types of safety precautions and general information are used in this manual: DANGER! DANGER indicates a hazardous situation which, if not avoided, will directly result in death or serious injury. WARNING! WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION! CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE! NOTICE indicates a situation that can result in property damage if not avoided. Information Information provides tips that are valuable for the optimal installation and operation of the product. 6 WB5A-6A-BA-BEN114530 User Manual

SMA Solar Technology AG Safety 2 Safety 2.1 Intended Use The Windy Boy is a wind energy inverter, which converts rectified current of a small wind turbine system into AC current and feeds this energy into the power distribution grid, domestic grid or the Sunny Island system. Principle of a small wind turbine system with a Windy Boy Furthermore, the Windy Boy can be used as an inverter for power conversion units based on permanent magnet generators (hydro power system, combined heat and power plant, diesel generator, etc.). The manufacturer of the small wind turbine system or generator should have approved his plant for operation with this Windy Boy (also see the Windy Boy planning guidelines in the download area at www.sma.de/en). When designing the PV plant, ensure that the permitted operating range of all components is maintained at all times. In addition ensure that through the use of appropriate protective measures the maximum permissible input voltage of the inverter is not exceeded. SMA Solar Technology AG offers you the corresponding components, such as the Windy Boy Protection Box (overvoltage protection for wind power inverters including the rectifier). User Manual WB5A-6A-BA-BEN114530 7

Safety SMA Solar Technology AG 2.2 Safety Instructions DANGER! Electric shock caused by high voltage in the inverter Even when no external voltage is present, there can still be high voltages in the inverter. The following work should be carried out by electrically qualified personnel only. Electrical installation Repairs Modifications CAUTION! Risk of burns through contact with the enclosure during operation Only touch the enclosure lid and display during operation. NOTICE! Damage to the inverter through overvoltage, if the yellow LED flashes 4 times. Inform your installer immediately if the yellow LED should start flashing and the following display message appears. 8 WB5A-6A-BA-BEN114530 User Manual

SMA Solar Technology AG Safety 2.3 Explanation of Symbols 2.3.1 Symbols on the Inverter Symbol Explanation Operation display. Ground fault or varistor defective. Inform your installer. An error has occurred. Inform your installer immediately. You can operate the display by tapping the enclosure lid: Single tap: The backlight switches on or the display scrolls one message further. Two taps in quick succession*: The inverter displays the device type, the firmware version and the configured country setting (see Section 4.2 "Display Messages during Operation" (page 12)). QR-Code ** for SMA bonus program You will find information on the SMA bonus program at www.sma-bonus.com. * This function is valid from firmware version 2.18. ** QR-Code is a registered trademark of DENSO WAVE INCORPORATED. User Manual WB5A-6A-BA-BEN114530 9

Safety SMA Solar Technology AG 2.3.2 Symbols on the Type Label Symbol Explanation Beware of hazardous voltage. The inverter operates at high voltages. All work on the inverter must be carried out by electrically qualified personnel only. Beware of hot surface. The inverter can become hot during operation. Avoid contact during operation. Observe all documentation that accompanies the inverter. The inverter must not be disposed of together with the household waste. Further information on disposal can be found in the enclosed installation manual. CE mark. The inverter complies with the requirements of the applicable EC guidelines. The inverter has a transformer. Direct current (DC). Alternating current (AC). Degree of protection IP65. The inverter is protected against dust intrusion and water jets from any angle. RAL quality mark for solar products. The inverter complies with the requirements of the German Institute for Quality Assurance and Labeling. 10 WB5A-6A-BA-BEN114530 User Manual

SMA Solar Technology AG Product Overview 3 Product Overview Position A B C D E Designation Display Enclosure lid LEDs Green LED = Operation Red LED = Ground fault or varistor defective Yellow LED = Disturbance Ventilation grid Type label for the identification of the inverter via the serial number (Serial No.). User Manual WB5A-6A-BA-BEN114530 11

Display SMA Solar Technology AG 4 Display 4.1 Operation The display shows the current values of your plant. The displayed values are updated every 5 seconds. You can operate the display by tapping the enclosure lid: Single tap: The backlight switches on or the display scrolls one message further. 2 taps in quick succession (valid from firmware version 2.18): The inverter successively displays the device type, the firmware version, the configured country setting and the configuration of the SMA Power Balancer. 4.2 Display Messages during Operation After commissioning, the inverter successively displays the device type, the firmware version, the configured country setting and the configuration of the SMA Power Balancer. If you want to view again the display messages of the startup phase while in operation, double tap the enclosure lid (from firmware version 2.18). Display message Description Inverter device type Firmware version of internal processors Configured country standard of inverter (example: "GER/VDE0126-1-1") Configuration of the SMA Power Balancer (Example: "PowerGuard") Upon error-free connection of the inverter to the power distribution grid, after approximately one minute, the display starts alternating between the messages shown below. Each message appears for 5 seconds, and then the cycle restarts from the beginning. 12 WB5A-6A-BA-BEN114530 User Manual

SMA Solar Technology AG Display Display message Description Energy generated on the current day Status message "Turbine" Current feed-in capacity Voltage of the small wind turbine system After a further 5 seconds or after tapping, the current values of the reactive power Qac and of the displacement power factor cos φ (PF) are displayed. Total amount of energy fed in Total number of operating hours in feed-in operation 4.3 Display Messages during a Disturbance In the event of a disturbance, the inverter displays the status "Disturbance" and an error message. Inform your installer. Display message Description Energy generated on the current day Status message "Disturbance" Operating state Error message Measured value at the time of the disturbance Current measured value (only displayed if a measured value is responsible for the disturbance) 4.4 DC Overvoltage Display message Description The DC input voltage is too high at the inverter. Inform your installer immediately! User Manual WB5A-6A-BA-BEN114530 13

LED Signals SMA Solar Technology AG 5 LED Signals Status Description All LEDs are on The inverter is initializing. All LEDs are off The DC input voltage at the inverter is too low for feed-in. All LEDs flashing The inverter is in the start phase. Green LED on The inverter is feeding in to the power distribution grid. Green LED flashing This flashing can have the following reasons: The inverter is monitoring the power distribution grid and is waiting for the DC voltage to reach a defined limit so that it can begin feeding the grid. Operation interrupted. Power limitation in the inverter. 14 WB5A-6A-BA-BEN114530 User Manual

SMA Solar Technology AG LED Signals Status Red LED on Description A ground fault has occurred or one of the thermally monitored varistors on the DC input side is defective. Inform your installer. Yellow LED on The inverter is in the operating state "Permanent Shutdown". This can have several causes. Inform your installer. Yellow LED blinks The inverter displays a disturbance. This can have several causes. Inform your installer. User Manual WB5A-6A-BA-BEN114530 15

Visual Inspection, Maintenance and Cleaning SMA Solar Technology AG 6 Visual Inspection, Maintenance and Cleaning Visual inspection Check the inverter and cables for any signs of external damage. Contact your installer if you find any damage. Do not perform any repair work yourself. Maintenance and Cleaning Ask your installer to check that the inverter is operating correctly at regular intervals. If the inverter is dirty and the visibility of the operating data and operating states of the inverter is limited, clean the enclosure lid, the display and the LEDs with a damp cloth. Do not use any corrosive substances (e.g., solvents or abrasives) for cleaning. 16 WB5A-6A-BA-BEN114530 User Manual

SMA Solar Technology AG Troubleshooting 7 Troubleshooting 7.1 Status Messages Your inverter can be in various operating states. These are displayed as status messages, which can vary according to the type of communication. Message Balanced Derating Disturbance, disturbance Error Earthfault Grid monitoring Off Grid Offset Stop Turbine V-Const Waiting Description The inverter has disconnected from the power distribution grid or is limiting its power over a 10-minute average to 4.6 kva (in Italy: 6 kva). The inverter is a part of a 3-phase system with 2 further inverters and is equipped with the SMA Power Balancer to prevent the formation of unbalanced loads. Overtemperature in the inverter. The inverter reduces its output to prevent overheating. To avoid unnecessary output losses, check the plant configuration. Inform your installer. Disturbance. This message appears for safety reasons and ensures that the inverter does not connect to the power distribution grid. Inform your installer. An error has been detected. Inform your installer. Measurement of the insulation resistance of the small wind turbine system. Grid monitoring This message appears during the startup phase before the inverter is connected to the power distribution grid. The inverter is in "Island" mode. This mode is specially designed for operation in an off-grid system. Offset adjustment of the measurement electronics. Operation interrupted. The inverter is in the operating state "Turbine". This mode is specially designed for operation on small wind turbine systems. Constant voltage mode. The connection conditions are not (yet) fulfilled. User Manual WB5A-6A-BA-BEN114530 17

Troubleshooting SMA Solar Technology AG 7.2 Measurement Channels If your inverter is equipped with a communication product, then numerous measuring channels and messages can be transmitted for diagnostics. Measurement channel Balancer Earthfault Error E-total Event-Cnt Fac h-on h-total Iac Ipv Is* Power On Pac PF* Phase Qac* Sac* Serial number Status Vac Vpv Vpv-Setpoint Description Displays the current operating mode of the inverter that is set to the operating parameter "PowerBalancer". Insulation resistance of the small wind turbine system before connecting to the power distribution grid. Identification of the current disturbance/error. Total amount of energy fed in Number of events that have occurred Power frequency Total operating hours Total number of operating hours in feed-in operation Line current Direct current Apparent current Total number of grid connections Generated AC power Displacement power factor cos φ The phase to which the inverter is connected. Reactive power Apparent power Inverter serial number Display of the current operating state Line voltage DC input voltage DC target voltage * From firmware version 2.18 18 WB5A-6A-BA-BEN114530 User Manual

SMA Solar Technology AG Glossary 8 Glossary AC Abbreviation for "alternating current". DC Abbreviation for "direct current". Derating A controlled reduction in performance, usually dependent on component temperatures. SMA Power Balancer The SMA Power Balancer is a serial feature of the inverter. The SMA Power Balancer prevents the formation of an unbalanced load > 4.6 kva (in Italy > 6 kva) during three-phase feed-in. To this effect, 3 Windy Boys are connected via a control line to a 3-phase feed-in unit. Varistor The varistors protect the electronics in the inverter from atmospherically coupled energy peaks, such as may occur when lightning strikes nearby. User Manual WB5A-6A-BA-BEN114530 19

Contact SMA Solar Technology AG 9 Contact If you have technical problems, first contact your installer. We require the following information in order to provide you with the necessary assistance: Inverter device type Inverter serial number Type of connected wind turbine system Blink code or display message of the inverter Optional equipment (e.g. communication products) SMA Solar Technology AG Sonnenallee 1 34266 Niestetal, Germany www.sma.de SMA Service Line Inverters +49 561 9522 1499 Communication: +49 561 9522 2499 Fax: +49 561 9522 4699 E mail: ServiceLine@SMA.de 20 WB5A-6A-BA-BEN114530 User Manual

SMA Solar Technology AG Legal Restrictions The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission. Exclusion of liability The general terms and conditions of delivery of SMA Solar Technology AG shall apply. The content of these documents is continually checked and amended, where necessary. However, discrepancies cannot be excluded. No guarantee is made for the completeness of these documents. The latest version is available online at www.sma.de or from the usual sales channels. Guarantee or liability claims for damages of any kind are excluded if they are caused by one or more of the following: Damages during transportation Improper or inappropriate use of the product Operating the product in an unintended environment Operating the product whilst ignoring relevant, statutory safety regulations in the deployment location Ignoring safety warnings and instructions contained in all documents relevant to the product Operating the product under incorrect safety or protection conditions Altering the product or supplied software without authority The product malfunctions due to operating attached or neighboring devices beyond statutory limit values In case of unforeseen calamity or force majeure The use of supplied software produced by SMA Solar Technology AG is subject to the following conditions: SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by SMA Solar Technology AG. This also applies to the provision or non-provision of support activities. Supplied software not developed by SMA Solar Technology AG is subject to the respective licensing and liability agreements of the manufacturer. SMA Factory Warranty The current guarantee conditions come enclosed with your device. These are also available online at www.sma.de and can be downloaded or are available on paper from the usual sales channels if required. Trademarks All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA Solar Technology AG is under license. SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel. +49 561 9522-0 Fax +49 561 9522-100 www.sma.de E-Mail: info@sma.de 2004 to 2011 SMA Solar Technology AG. All rights reserved User Manual WB5A-6A-BA-BEN114530 23