Wind Turbine Technical Specifications

Similar documents
Wind Kids Series Wind Turbine Specification

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS

10KW 3 Phase Off Grid Hybrid System

Model: H kW. Features: 1. SCF Supercritical generator. 2. NSK bearings. 3. PLC integrated with Siemens module. 4. Low noise

Solar Inverter 3kW-8kW Inverter (off-grid)

Application. Battery. Public Grid GS HYBRID INVERTER

400W / 600W / 1000W / 1500W DIY Wind Turbine

Model: H4.6-3kW / H6.4-5kW / H8.0-10kW / H9.0-20kW

Specification of High quality Intelligent Inverter with Built-in MPPT Controller I-P-HPC series

Model: H kW. I. Features: 1. SCF Supercritical generator. 2. SKF bearings. 3. PLC integrated with Siemens module. 4.

H4.6-3kW/H6.4-5kW/H8.0-10kW/H9.0-20kW. Technical Overview ANHUI HUMMER DYNAMO CO., LTD.

ned100 Wind Turbine Generator a step towards your energy independence

2,600W Wind/Solar Hybrid System HY-W2S6

Some admonitions you must know before using DS600

SOLAR OFF-GRID MPPT PCU ESM3K/48, ESM5K/96, ESM7K5/120, ESM10K/120

Photovoltaics. MPI Hybrid Series

SANGSTER 300W Off grid wind power supply systems System

Solar-Wind. Solar-Wind Hybrid LED Street light. Advantages and Benefits

RW-30kW variable pitch wind turbine

Anakata New Generation Wind turbines 400W-1400W

MERU Solar Off-Grid Inverters

FD21-50 GHREPOWER. Version: 3.0

Solar Inverter Manual

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Content. Introduction Products... 4 AVR05TX... 6 AVR1KTX... 7 AVR2TX... 8 AVR3TX Energy Tower AVTO1000/

00 W(Edited on Aug. 23rd, 2011) Mod. noram. tures

Energy.ca. www. Energy.ca. www. .GreenerEnergy.

Don't let the shadows of yesterday hide the sunshine of tomorrow Nandina Morris

PWM WIND SOLAR HYBRID CHARGE CONTROLLER USER MANUAL

PWM WIND(SOLAR) CONTROLLER USER MANUAL

HOW TO USE H5000B TO RUN 5KW OF ENPHASE M250 OFF-GRID

6M 30w solar wind hybrid street light

WIND MILL 2000W 96V+STAND

青岛恒风风力发电机有限公司 QINGDAO HENGFENG WIND POWER GENERATOR CO.,LTD

Engineer Solar Limited

Wind Energy System.

POWER. Inverters.

WELCOME! Small Wind Generators. Structure of this Presentation. Where is this? Where is this? Introduction to Wind Energy

SOLAR POWER PACKS OFF-GRID SYSTEMS (150Wp-10kWp:Single Phase)

Qualification certificate

9kW Multi Wind-Lens Turbine Specification (3kW WL turbine x 3 units)

OFF GRID SOLAR INVERTER

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type>

Solar inverter AX-series

BYD Distributed Energy Storage System (DESS) Integrated Type (European Version)

The wind/solar hybrid controller is control device which can control wind turbine and solar panel at the same time and

PRAMAC Wind Generators are Vertical Axis Turbines (Darrieus H-shape type), since: Moreover they are very small in size.

Zhejiang Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital of China's electrical appliances" Wenzhou.

Wind-Electric Systems

WIND ENERGY MODULAR TRAINER WITH CONNECTION TO MAINS DL WIND-A1G

The wind/solar hybrid controller is the control device which can control wind turbine and solar panel at the same time and

brighter future take charge of your family s energy future harvest power year-round, night and day with a wind+solar hybrid system from Pika.

Performance of Photovoltaic and Wind Hybrid Inverter

User s Manual Wind/Solar Hybrid Controller

Pure sine wave charger inverter Product Manual

AH-5kW pitch controlled wind turbine on grid system

Solardyne Corporation Renewable Home Power Design Guide Call

Mass Combi Ultra 24/ (230 V)

Future Electronic Power Distribution Systems A contemplative view

WIND TURBINE ELECTRICAL AUTOCONTROLLOR

Dimon Technology Ltd. Dimon Technology Ltd.

On Grid Wind Turbine(wind solar hybrid)controller

MATERIAL DATA SHEET* ALPANA d.o.o.

SMART 1000 / 2000 SERIES

new energy leads low carbon life.

Wind/Solar Hybrid Controller User Manual. Model: HY-C10-24AWM and HY-C10-48AWM

Off-Grid Solutions (Solar Controller & Invertor)


March Powerhouse Wind Ltd. Document Technical Summary for Thinair 102.

Ampd Silo. Energy Storage System. Maintenance-free Li-ion energy storage for mission critical backup. Power to Empower

Technical Specifications of Solar PCUs

The Evolution of Vertical Wind Technology

User Manual. Wind and Solar Hybrid Charge Controller 1KW / 2KW 48VDC. HCON Series

MPPT Solar Charger With Constant Current Driver

Operating & Installation Manual

200w-600w Wind Solar Hybrid Street Light Controller

Unit 32 Three-Phase Alternators

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

YOUR POWER STORAGE SOLUTION!

Yueqing Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital

GE USER MANUAL

wind turbine system For New Design

Wind-Solar Hybrid Power Generation Systems. Energy Pvt. Ltd.

HY10-AD7.8 WIND TURBINE

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

Configuration Diagrams

Parts Catalogue. Solar (PV) Panels. Mounts. Inverters. Power Panels. Battery Monitors. Charge Controllers. Meters. Batteries. And more...

User Manual HomeGrid 5000 HD

Current Automation Catalogue Page 27

Conclusions. Fall 2010

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING B.ENG (HONS) ELECTRICAL & ELECTRONIC ENGINEERING EXAMINATION SEMESTER /2017 RENEWABLE ENERGIES

Solar PCU/Inverter 1 KVA to 100 KVA

Wind Turbine Guidebook. For HYenergy HY-400, HY-600, HY-1000, HY-2000, HY-3000 Off-grid Models

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical specifications. Wind Turbine GS 21 S. Power 60 kwp

Brochure. Wind turbine generators Reliable technology for all turbine applications

Transcription:

Wind Turbine Technical Specifications Model: SIKCO Wind 2000 Quick Details Place of Origin: Kharghar Brand Name: SIKCO Capacity 02 KWh / day Rated power: 100W Max power: 180W Output voltage: DC12V/ DC 24V Rated wind speed: 4.9 m/s Rotor diameter: 2.4 m Blade material: GFRP Start-up wind speed: 1.9 m/s Work wind turbine speed: 200r/min Number of blades: 3 Turbine weight: 18 kg Except blades Each Blade weight 2 kg Turbine Blade Blade Material Property Glass fiber reinforced plastic (GFRP) Technical name Density [g/cm 3 ] 1.2 1.35 Thermal conductivity [W/(m K)] 0.24 0.38 Yield strength [MPa] 41 60 Young's modulus [psi] 480000 Flexural strength (yield) [psi] 11500 Compression strength [psi] 9400 Coefficient of thermal expansion (linear) [mm/(mm C)] 5 10 5 Vicat B [ C] 65 100 Resistivity [Ω m] 1000 Surface resistivity [Ω] 10 13 10 14 Fiber-reinforced polymer

Controller Intelligent Micro processor Protection against short circuit, over and under voltage Voltage range Current Range High speed condition Reverse connection provided Wattmeter / Voltmeter / Ammeter / KWH meter Battery over and discharge provided Over current protection Output over voltage Manual locking Over speed protection in gusty wind Working temperature Relative humidity (Digital) 12V-24 V (Auto selection) 05 A - 15 A Load bypass to dump load (Digital) (Unload to dump load) Auto yaw movement / flexi blade 0-55 C 0-95% RH Alternator Body Aluminum casting Winding Copper Magnet Permanent Double bearing Model SIKCO Wind 2000 Rated Power (Watts) @4.9 m/sec 100 Maximum power (Watts) 180 watts Design Voltage (V) DC 12 Rated Rotation (rpm) 200 Size in dia (mm) 200 Pole pairs 8 Work Temperature( C) -30 C to +65 C Generator Style 3-phase AC PM Startup Torque (N m) 0.9 Net Weight (kg) 04 Make SIKCO Cable Polycab / Finolex/ Equivalent Start-up / Cut-in wind speed 1.9 m/s & 2.9 m/s Design wind speed 4.9 m/s Cutout speed 21 m/s

Turbine Basic Specifications: 1. Low speed permanent magnet generator 2. Low starting torque, High generating efficiency 3. Glass fiber high efficiency blades 4. SKF bearing with high performance 5. Balanced yaw system 6. Designed for minimal maintenance and easy install 7. Downwind and auto control of speed 8. The span life is 20~25 years. High quality and competitive price guarantee SIKCO a huge market all over India and in Africa as well. Micro-processor based intelligence controller 1. Showing line voltage output. 2. Have the auto-protection function of the batteries Reverse protection, anti-disconnect battery protection, battery damage protection. 3. When the charge current is high in strong wind, controller can load the wind turbine automatically by passing extra power to dump load. And charging the battery with low current. 4. The wind turbine loads uniformly with fully loaded all the time. Pure sine wave inverter (Off grid) 1. Pure sine wave output can drive any household appliances. 2. Use integrated circuit, less wire connection. 3. Adopting micro-processor technology, improving system integration. 4. Excellent protection includes over voltage shutdown, under voltage shutdown, over current 5. UPS mode and Inverter mode

Pure sine wave hybrid inverter (On grid ) 1. When solar/wind energy is sufficient then total o/p load will be on solar/wind through MPPT & Inverter. Excess solar/wind power will charge batteries. 2. When solar/wind energy is weak then inverter is taking DC source from solar & balance from batteries. 3. When batteries reach 75% discharge level (25% kept as a buffer) the o/p load is shifted to grid and change over time will be 1 to 2 seconds. 4. After shifting load to grid (bypass) the batteries are charged from solar/wind energy and if solar energy not sufficient to charge the batteries, then remaining DC power is taken from grid chargers (Inverter is acting as a grid) 5. Once the batteries are fully charged then load is shifted back to inverter from grid. 6. During change over from inverter to grid (i.e 75% battery discharged) and if grid supply is not present then again load is shifted to inverter to use buffer battery backup (i.e balance 25%) 7. When grid returns during inverter which is working on buffer battery backup then the load is shifted to grid & batteries are charging through solar/wind or grid as per bidirectional logic. Competitive Advantages: Down Wind Turbine is small in size, and simple in design. It fully uses lift and drags force, easily produce rated power at low wind speed. 3 Phase Permanent Magnet AC Generator, direct driven, no gearbox, and not need Tail. Less maintenance due to simple construction. It has perfect performance in low wind speed. With low rpm of generator; controller can be MPPT, on grid; inverters can be pure sine wave with automatic off-grid interface or directly on grid invertors. Furling less design Can be installed on the building rooftop Uses downwind designs

ons Life time service assurance Packaging & Delivery Packaging Detail: Metal piping frame / Plywood box/case Delivery Detail: 21 working days after clear PO