CAV-S Mechanical constant volume fl ow controller, steel

Similar documents
Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Volumetric Flow Limiter VOLKOM

Technical documentation

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers Type RN

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Volume Flow Limiters Type VFL

Mechanical mixing box MBM

CONSTANTFLOW Volume Flow Controllers

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

VAV TERMINAL BOXES TYPE: BA BT

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Round Duct System Model RR-Complete

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

VALVES WITH UM ELECTRIC ACTUATOR

Series 26d Ball Valve

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Technical information

VALVES WITH UV ELECTRIC ACTUATOR

volumetric flow controller Model VRA-Q Smart

VARYCONTROL VAV Dual Duct Terminal Boxes

VAV Terminal Units SDS

Ceiling swirl diffusers

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC

Round Duct System Model RR-Complete

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

4.1 Functional diagram FM100 fume hood monitor... 4 Functional description FM Interfaces Terminal diagram FM100...

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Parts and characteristics

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

CONTENT INTRODUCTION... 3 PRESSURE SENSORS INSTALLATION... 3 PIPES CONNECTION... 4 ELECTRICAL CONNECTION TO THE UNIT... 5

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

7 Services Control and monitoring

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

DATA SHEET TB 26l. BR 26l, BR 26t, BR 26v, BR 26x Multi-port ball valve Ball valve in horizontal and vertical version. Application

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

Rotary Plug Valve BR 23e

BR 26d Ball valve. Stainless Steel. Application: Versions: Special versions:

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

VAV controller. TROX Auranor Norge AS. Telephone Fax

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Round duct grille Model KG-RR

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

BR 20b Ball valve. PFA-lined. Application: Versions:

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

ceiling swirl diffuser Model DQJA / DQJR

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Particle Filter Box FKU

The Innovation Company. LTG Aktiengesellschaft. Technical Brochure. LTG Air Distribution. Highly-tight shut-off damper KLB

Fan coil unit NBS 100/150

Drain ball valve BR 21a

Temperature Sensors. Information Sheet

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Combustion gas damper EKO-JB

Particle Filter Box Model FKF

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

MULTI-LEAF & SHUT-OFF DAMPERS Product Catalogue

For installation into ductwork

Access Products. Download Wentyle Download AlnorCAM Buy via B2B

LTG Air Distribution. Product Overview

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

FILLING AND CHECK VALVE

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

Round duct diffuser DBB-RR

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating

Ceiling diffuser 4DE

Mixing Box MBE / MBP

OPERATING INSTRUCTIONS

Transcription:

Product description Function description Features Product description The mechanical constant fl ow volumetric controller CAV-S is made of galvanized steel and works independently without requiring additional energy. The housing design is available in round or rectangular CAV-S, round Functions description The central ball-bearing fl ap is moved by the air current. The control unit with control cam, spring and damper is attached to the outside of the galvanised sheet steel housing. The required volumetric fl ow is set in-factory. An adjustment of the volumetric fl ow at a later stage is possible (setting cam on housing). The control unit is protected with a cover. The controller can be assembled in any assembly position. CAV-S, rectangular For maintenance, service, retrofi tting, etc., inspection openings in suffi cient number and size must be provided onsite. Available connections are socket/socket, fl ange/fl ange or pipe/pipe. The constant volume fl ow controller CAV-S is suitable for supply and exhaust air fl ow control and the air volumes setpoints are step adjustable (1...10 steps). To ensure accuracy, a suffi cient fl ow route should be maintained. Attention: The CAV-S is an adjusted controller working by the mechanism of action principle. Tampering with the controller, whether manually or mechanically, is prohibited. When a high volumetric fl ow setting has been selected, the damper leaf must never be closed manually. Otherwise, the control mechanism will be changed, resulting in a loss of control accuracy. The range of application must always be complied with. If the CAV-S is used beyond its allowed range of application, this will result in mechanical overload and thus in a loss of control accuracy. We would like to point out that to clean the stainless steel design, only suitable corresponding cleaning materials must be used! Features Housing design available in round or rectangular Self-acting constant flow regulator made of galvanized steel Suitable for supply or exhaust air volume control Mountable in any position Externally accessible adjuster for adjustable volume fl ow rate setpoints Flow range > 7:1 Control spring stainless steel Low friction damping element Differential pressure range 50.. 500 Pa High accuracy of the adjusted volume flow rates of ± 5 %, based on VNOM Operating temperature 10 to +50 C Storage temperature -20 to +60 C Without auxiliary power Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com 1

Order code: Mechanical constant volume flow controller - round CAV - 250 - S - 0-0 - 0 - RR Type Diameter DN [mm] 80, 100, 125, 160, 200, 250, 315, 400 80... 400 Material case Galvanized steel Stainless steel 1.4301 Stainless steel 1.4571 S V2 V4 In- Outflow Pipe connections Remarks RR Pipe Pipe Steel and stainless steel FF Flange Flange Steel and stainless steel Acoustic cladding 0 without D with DD-coating 0 without DD with Rubber lip seal 0 without G with Ordering example: Mechanical constant volume flow controller, round Diameter 250, galvanized steel, without rubber lip seal, without DD-coating, without insulation shell, pipe/pipe. Make: SCHNEIDER Type: CAV-250-S-0-0-0-RR Order code: Mechanical constant volume flow controller - rectangular CAV - 400-200 - S - 0-0 Type Width B [mm] 200, 300, 400, 500, 600 200... 600 Height H [mm] 100, 150, 200, 250, 300, 400 100... 400 S Acoustic cladding 0 without D with DD-coating 0 without DD with Material case Galvanized steel Ordering example: Mechanical constant volume flow controller, rectangular Width=400 mm, Height=200 mm, Galvanized steel, without DD-coating, without insulation shell. Make: SCHNEIDER Type: CAV-400-200-S-0-0 2 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com

Volumetric flow range CAV-S-round Volumetric flow range CAV-S-rectangular Nominal size V (m³/h) V [l/s] NW [mm] min. max. min. max. 80 31 210 9 58 100 48 383 13 106 125 81 558 23 155 160 112 902 31 251 200 177 1442 49 401 250 240 2280 67 633 315 326 3299 91 916 400 429 4571 119 1270 Installation information To avoid unnecessary controller errors, the min. distances according to the following table / drawings must be observed. For combinations of several connection pieces or pieces with fi re dampers or silencers, the larger minimum distances must be observed. The volumetric fl ow controllers round and rectangular can be assembled with horizontal or vertical damper axis. V (m³/h) V [l/s] Width x Height min. max. min. max. B [mm] H [mm] 200 100 50 820 14 228 300 100 48 1161 13 323 300 150 213 1484 59 412 300 200 224 1830 62 508 400 446 2924 124 812 500 723 3188 201 886 600 656 3517 182 977 400 250 571 3180 159 883 500 712 4219 198 1172 600 767 4690 213 1303 400 300 661 4441 184 1234 500 871 5020 242 1701 600 395 5784 110 1607 400 400 276 5630 77 1564 500 806 6125 224 1701 Distance to: round rectangular Connection piece with bend 1 x D 1 x diagonal Other connection pieces: 2 x D 2 x diagonal branching or reducing piece, T-junction, etc. Fire damper 2 x D 2 x diagonal Silencer 2 x D 2 x diagonal Installation information CAV-S-round Distance to a connection piece with bend Installation information CAV-S-rectangular Distance to a connection piece with bend Distance to other connection pieces ( e.g. branching or reducing piece, T-junction, etc.), fi re damper or silencer Distance to other connection pieces ( e.g. branching or reducing piece, T-junction, etc.), fi re damper or silencer Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com 3

Nominal size Constant air volume flow controller - round Step adjustable volume flow setpoints [m³/h] NW [mm] Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 80 31 37 47 89 127 160 186 204 209 210 100 48 64 128 195 248 302 332 352 379 383 125 81 95 199 277 355 411 470 506 526 558 160 112 144 233 352 501 624 733 823 871 902 200 177 262 440 577 843 952 1129 1250 1362 1442 250 240 346 541 844 1156 1498 1781 1990 2167 2280 315 326 555 957 1356 1882 2293 2661 2907 3128 3299 400 429 853 1545 2039 2672 3284 3660 4118 4365 4571 Width x Height Constant air volume flow controller - rectangular Step adjustable volume flow setpoints [m³/h] B [mm] H [mm] Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 200 100 50 114 247 374 521 602 699 737 790 820 300 100 48 190 210 360 583 763 880 1041 1142 1161 300 150 213 259 432 620 853 986 1169 1290 1392 1484 300 200 224 319 400 729 958 1198 1333 1589 1731 1830 400 446 789 1128 1534 1819 2199 2406 2662 2813 2924 500 723 778 1270 1501 1988 2335 2730 2931 3078 3188 600 656 786 1170 1540 1976 2449 2733 3152 3307 3517 400 250 571 883 1200 1559 1963 2351 2752 2931 3075 3180 500 712 996 1368 1778 2334 2846 3233 3700 4005 4219 600 767 950 1344 1920 2531 3077 3668 4061 4408 4690 400 300 661 1013 1485 1994 2553 3141 3579 3954 4269 4441 500 871 1352 1766 2389 3070 3665 4255 4519 4826 5020 600 395 1159 1519 2255 2925 3779 4454 4933 5447 5784 400 400 276 1373 1813 2831 3523 4123 4717 5134 5405 5630 500 806 1539 2248 3151 3823 4436 4983 5405 5813 6125 4 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com

Flow generated noise CAV-S, round Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com 5

Radiaded noise CAV-S, round 6 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com

Radiaded noise CAV-S, round, with acoustic cladding Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com 7

Flow generated noise CAV-S, rectangular 8 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com

Flow generated noise CAV-S, rectangular Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com 9

Radiaded noise CAV-S, rectangular 10 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com

Radiaded noise CAV-S, rectangular Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com 11

Radiaded noise CAV-S, rectangular, with acoustic cladding 12 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com

Radiaded noise CAV-S, rectangular, with acoustic cladding Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com 13

Models and dimensions The CAV-S, rectangle is only delivered in right-hand design. If the control unit is required on the left-hand side, the CAV- S must be rotated by 180. Nominal size NW [mm] Available sizes CAV-S, round ØD [mm] L [mm] 80 78 290 100 98 290 125 123 290 160 158 290 200 198 290 250 248 390 315 313 390 400 398 490 Available sizes CAV-S, rectangle Height H Width B 200 300 400 500 600 100 x x - - - 150 - x - - - 200 - x x x x 250 - - x x x 300 - - x x x 400 - - x x - x = available - = not available LR = Air fl ow direction No liability for misprint or modifi cations All rights reserved SCHNEIDER Tender specification CAV-S, round Mechanical volumetric fl ow controller type CAV-S, in round design, right-hand model, for constant volumetric fl ow regulation for duct connection to DIN EN 12237. Housing and control damper made of galvanised sheet steel, control housing made of plastic. Externally accessible adjusting for step adjustable fl ow rate setpoints. Differential pressure range 50 to 500 Pa, tolerance range typically ± 5 %, operating temperature 10 to +50 C. Product: SCHNEIDER Type: CAV-S Size: Tender specification CAV-S, rectangle Mechanical volumetric fl ow controller type CAV-S, in rectangle design, right-hand model, for constant volumetric fl ow regulation for duct connection to DIN EN 12237. Housing and control damper made of galvanised sheet steel, control housing made of plastic. Externally accessible adjusting for step adjustable fl ow rate setpoints. Differential pressure range 50 to 500 Pa, tolerance range typically ± 5 %, operating temperature 10 to +50 C. Product: SCHNEIDER Type: CAV-S Size: SCHNEIDER Elektronik GmbH Phone: +49 (0) 6171 / 88 479-0 Industriestraße 4 Fax: +49 (0) 6171 / 88 479-99 61449 Steinbach Germany e-mail: info@schneider-elektronik.de 14 Technical Documentation CAV-S Date: 11/2012 Subject to change without prior notice www.schneider-elektronik.com