HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

FUSES. Safety through quality

Medium Voltage current limiting Fuse links

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Medium Voltage current limiting Fuse links

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

High voltage high-breaking capacity VV fuse-links

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

STROM SICHER SCHALTEN

W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

15/60 15/60. FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. Operating and maintenance instructions

Limitor -G General Purpose Fuses

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

High voltage current limiting Fuse links type CEF

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH D MOOSBURG TEL. ( ) FAX ( )

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Rated voltage 12 kv to 38.5 kv Rated current 630 A to 2500 A

Fuses are the most effective and economic ways of protection against short circuits in m.v. installations.

Use of switch-fuse combinations at the medium-voltage level for the protection of distribution transformers siemens.com/tip-cs

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

High-Voltage Fuse Links according to IEC

Thermal system protection of switchgear through high voltage fuse links with integrated temperature limiter under consideration of IEC 420:1990

High-voltage high-breaking capacity VV fuse-links

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

HIGH VOLTAGE FUSE-LINKS HIGH VOLTAGE FUSE-LINKS WITH THERMAL STRIKER HIGH VOLTAGE FUSES POWER NEEDS CONTROL

Miniature Circuit-Breakers (MCBs)

High-voltage high-breaking capacity VV fuse-links

Medium voltage products. Fuses

EUROPEAN HIGH VOLTAGE FUSES

Medium voltage products. Fuses

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

3.2. Current Limiting Fuses. Contents

HV-Fuse-links SSK type SSK 10/02

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled

Medium voltage fuses - European Fuses

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

LG HRC Power Fuses ISO 9001 ISO 14001

IEC Standard Back-Up Fuse-Links

I-1 DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE. Overview

34-SDMS-02 SPECIFICATIONS FOR

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

NEOZED D0 fuse-links gg 400/440VAC

MV SWITCHGEAR 511. CF / SOLEFUSE / TEPEFUSE / MGK MV current limiting fuses With thermally operated striker From 3.6 to 36 kv

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. ( ) FAX ( )

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

H 29 H 29 H 29 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

RBA Catalog Numbers and Information

X-Limiter full-range current-limiting fuse

Applications. Fuse range selection. Motors Power transformers. Voltage (kv)

Electrical Protection

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Contactor-Fuse Combination 3TL62 / 63 / 66

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

Protistor size 70 gr 690VAC (IEC)

DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE

THE PROTECTION OF INDUSTRIAL CAPACITOR BANKS BY CURRENT LIMITING FUSES. By M.J. Smart and B. Wadcock

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

Mica Element Support. Compacted Quartz Sand. Length B

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

General information on current-limiting fuse-links. The main characteristics of the CNC fuse-links. Construction. Operating.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

OHB Outdoor sulphur Hexafluoride circuit-breaker

CYLINDRICAL FUSES CYLINDRICAL FUSES

Medium voltage fuses Medium voltage fuses

MEDIUM VOLTAGE DIN Fuse-Links

SWITCHGEAR DIVISION PRODUCT PROFILES

Semiconductor Fuses European Fuses

onlinecomponents.com

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

RAPIDPLUS. high speed fuse links for semiconductors

Connect - Contact - Control. Fuses for high-voltage switchgear F-HS, F-VS Series Ø 60. F 185.en

Control Circuit Protection

RAPIDPLUS. high speed fuse links for semiconductors

Extensible Unit - VCE2a

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast).

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

HD4. Gas insulated MV circuit-breakers kv A ka

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

Power systems Protection course

FUSE: SAFE & RELIABLE

Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES

INDUSTRIAL CYLINDRICAL FUSE LINKS

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Bussmann series NH catalogue. Leadership in circuit protection

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

Ultra-Rapid Fuse Links for the Protection of Semiconductor Rectifiers

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

NX indoor current-limiting fuses

HIGH VOLTAGE CURRENT LIMITING FUSE-LINKS CAPABLE OF BREAKING ALL CURRENTS THAT CAUSE MELTING OF THE FUSE-ELEMENT. D. van der Scheer H.F.J.

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Transcription:

HH DRIESCHER - High-voltage high breaking capacity fuses from 1 kv up to 36 kv HH HH ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-866 MOOSBURG TEL. +9 87 61 6 81-0 FAX +9 87 61 68 11 37 http://www.driescher.com infoservice@driescher.de

DRIESCHER - High-voltage high breaking capacity fuses according to EN 608-1 3 5 6 8 9 11 1 General description types design the striker pin H.v.h.b.c. fuses type STA with striker and thermal protection up to 0 A H.v.h.b.c. fuses type SSK with striker and thermal protection up to 1 A Limitation of short-circuit current Time-current characteristic for h.v.h.b.c. fuses 6,3 A up to 0 A Recommended protection for DRIESCHER - Switch-fuse combination Thermal protection Testing cartridge Bypass tubes fuse tongs fuse holders fuse extension ø Striker pin 35 Weather-resistant foil 33 Integrated thermal cut-out Sealing compound Ferrule fitted Fuse element support Ceramic insulating tube Pure-silver fuse element welded to connecting strip e Weld to contact ferrule Silica sand Rated voltage in kv e in mm 33 7 5 d Pic.: 1

General description DRIESCHER h.v.h.b.c. fuses are automatic and selectively acting medium-voltage switchgears for the voltage range from 6 to 36 kv. With their extremely fast short-circuit interruption they reliably protect transformers, cables, capacitors and switching installations against the thermal and dynamic effects of short circuits. DRIESCHER h.v.h.b.c. fuses are designed for installation in air and gas-insulated switches in outdoor switches in troublesome climates Their dimensions are in compliance with the DIN 36 and meet the requirements of DIN EN 608-1, IEC 60787, IEC 606, IEC 6059, and EN 671-5. Types DRIESCHER h.v.h.b.c. fuses are back-up fuses which can interrupt all currents from the rated breaking current I 1 down to their smallest breaking current I 3. All types of our h.v.h.b.c. fuses are made with porcelain tubes which are glazed brown for use indoors and outdoors. The contact faces of the ferrules are of the same diameter irrespective of type, rated current and rated voltage. Design All h.v.h.b.c. fuses with a striker impact force of N are provided with integrated thermal protection as standard. H.v.h.b.c. fuses are also available with a release force of 1 N, but without thermal protection. Rated Voltage 1 kv kv 36 kv Part No: 796 15... (according to A) 796... (according to A) 796 35... (according to A) The parallel connected fuse elements of the DRIESCHER h.v.h.b.c. fuses are made of pure silver. The fuse element design and manufacturing method of the reduced cross section areas ensure a close characteristic tolerance. These fuse elements are wound on a star-shaped ceramic support and are welded at the end by resistance welding at the silver plated ferrules. The copper ferrules are pressed onto the porcelain tube, i.e. they are mechanically connected to the porcelain tube and are additionally provided with a permanent elastic sealing. The striker pin The energy storage mechanisms installed in the h.v.h.b.c. fuses operate immediately when the fuse element melts or by activate of the thermal protection. The striker pin, which is available with a release force of or 1 N, mechanically operates the breaker mechanism of a load-break switch or operates a special device for remote indication. 3

H.v.h.b.c. fuses with striker and thermal protection up to 0 A Type STA, release force N Rated Rated e d Weight Rated breaking Minimum breaking power loss Part No. voltage [kv] current [A] [mm] [mm] [kg] current I 1 [ka] current I 3 [A] [W] 6,3 31,5 0 1 0,0,0,0,0 3,8 3 3 56 70 90 1 1 170 3 390 600 8,5 11, 8 8 3 9 38 56 76 159 96 797 00 797 00 797 006 797 0 797 0 797 0 797 0 797 030 797 0 797 0 797 0 797 0 797 0 797 1 797 0 6,3 31,5 0 1 0,9,9,9 5, 5, 5,6 3 3 56 70 90 1 1 170 3 390 600 13,5 9 5 59 6 56 7 6 8 13 17 3 3 16 797 00 797 00 797 006 797 0 797 0 797 0 797 0 797 030 797 0 797 0 797 0 797 0 797 0 797 1 797 0 6,3 31,5 0 7 7 7 7 7 7 7 7 7 7 7 7 7,6,6,6,6,6,6,6 3,5 3,5 6,0 6,0 6,0 6,0 3 3 56 70 90 1 1 170 3 1 35 78 79 66 87 1 186 15 797 3000 797 3000 797 30006 797 300 797 300 797 300 797 300 797 30030 797 300 797 300 797 300 797 300 797 300 Dimensions e and d see page, Pic.: 1

H.v.h.b.c. fuses with striker type SSK and thermal protection up to 1 A Type SSK, release force N High-voltage high breaking capacity fuses type SSK for the protection of high power transformers with a special alignment to the rated transient current of switch-fuse combinations according to EN 671-5 These high-voltage high breaking capacity fuses complete the existing product range.the fuses are specially used in switches with relatively low values of switch opening timesand of the transient current which are used in front of transformers with a power of more than 0 kva. (Because of the favourable relation between transient current of the fuse and the rated transient current of the switch in case of lower transformer powers, standard fuses can be used). The determination of the rated current of the fuses for the transformer protection is effected according to the recommendations of the fuse manufacturers following VDE 00 Part. The main aim was to reduce the melting times below 0 ms clearly, without influencing further fuse characteristics in a negative way. The requirements for a lower temperature rise have been successfully carried out, the output in the rated operation of the corresponding transformer is only 70 to 75 watt. Further on, the kwn low value of the minimum breaking current of our standard high-voltage high breaking capacity fuses in the height of 3.5 times of the rated current was kept the same. Advantages: quick time-current behaviour in the transition range of "quick switches suitable for high transformer capacity low output low temperature rise low values of the minimum breaking current I3 Rated Rated e d Weight Maximum breaking Minimum breaking Power loss Part No. voltage [kv] current [A] [mm] [mm] [kg] current I 1 [ka] current I 3 [A] [W] 0 1,0,0,0 3,8 60 3 6 76 98 135 797 190 797 190 797 190 797 191 0 1,9 5, 6,3 60 3 13 188 77 797 90 797 90 797 91 5

Short-circuit current limitation DRIESCHER high-voltage high breaking capacity fuses already break during the current rise in the first loop of short-circuit current. They are thus short-circuit current limiting. The progress of a short circuit break is shown in the figure below. Without a fuse connected upstream the short-circuit current would behave as shown by the broken line I k (t) and reach the maximum value I p (peak shortcircuit current). The current limiting action of the fuse, however, only permits the cut-off current i D to rise up to the height of the melting current i s (full line). During the arcing time t L the current decreases with increasing arc length and is finally broken in the vicinity of the voltage zero passage. The currentlimiting action of the fuses relieves equipment and system parts of thermal and dynamic stress. It is clear that the application of current-limiting fuses is particularly advantageous in older installations which have t been designed for the increase in system short-circuit levels. The value of the cut-off current is influenced by the design of the fuse. It also depends on the rated current (fuse element cross section), the rate of current rise and the moment in which the short circuit occurs. i s melting current i p i D i k (t) i p cut-off current behaviour of short circuit current when fuse is replaced by metal link peak short-circuit current Voltage i k (t) t s t L pre-arcing time arcing time Current t s i s = i D t L 6

Short-circuit current limitation From the following diagram the cut-off current of the DRIESCHER high-voltage high breaking capacity fuses can be determined as a function of the r.m.s. value of the symmetrical component and of the rated current. The prospective short-circuit current I k " is expressed by the r.m.s. value of the symmetrical component of the short-circuit current I k (t) at the instant of the short circuit which would flow at the position of installation if the fuse were replaced by a link. The cut-off currents determined give the maximum value which might occur for a given r.m.s. value of the symmetrical component of the prospective short-circuit current with highest rate of current rise. Actual values are thus, as a rule, below the values determined. 3 8 6 8 6 1 8 6 0 A 1 A 0 A A A A A A A A A A A cut-off current in ka 0 8 6-1 6 8 0 6 8 1 6 8 6 8 3 r.m.s. value in ka 7

Time/current characteristics for DRIESCHER h.v.h.b.c fuses from to 0 A The diagram below shows the pre-arching time/current characteristics of DRIESCHER h.v.h.b.c fuses with rated currents from to 0 A. Close tolerances of the elements (tolerance 0.003 mm), stringent controls during manufacture and a conscientious electrical checking of the required values on finished fuses assure that the characteristics are being met within narrow limits. 5 5 5 Current in A 3 5 0 A 1 A 0 A A A A A A A A A 5 A A 3 5 5 1 5 0 5-1 5-5 Time in s 1 8

Application of switch-fuse combination in accordance with EN 671-5 on distribution transformers Switch-fuse combinations are used for operational medium voltage-side on and off switching of distribution transformers in secondary substations. They additionally have the task of protecting these transformers against the impact of internal and external faults. These combinations comprise a functional unit of switch disconnectors and back-up fuses. By means of the fuses the breaking capacity of the combination is extended beyond that of a simple switch disconnector up to the rated short-circuit breaking current. The high-voltage high breaking capacity fuse, according to statistics of the VDN (German Association of Electricity Network Operators) is rated as reliable transformer protection. The h.v.h.b.c. fuse in combination with a switch disconnector provides a simple solution which is very ecomical to procure and run. This provides a clear-cut advantage over a circuit breaker with the associated current transformers and overcurrent time protection. Besides this, the h.v.h.b.c. fuse has a current limiting effect when short-circuits occur and reliably interrupts the fault current of the first half cycle. These properties are advantageous for the dimensional design of the network. The following tables give fuse recommendations which take the following points into account: inrush current when switching on off-load transformers permissible overload 1% primary short-circuit interruption upon secondary terminal short circuit The manufacturer of the combination will provide a recommended list of suitable fuse makes. Type STA SSK Manufucturer DRIESCHER Moosburg Siba Lünen Recommended protection for DRIESCHER - Switch-fuse combination in accordance with EN 671-5 Fuse-Type STA and Type SSK High-voltage high breaking capacity fuse link for Ur = 1 kv Fitting dimensions of fuses e = -1 mm Ratedtransformerpower [kva] Possible application of the switch-fuse combination Rated voltage U r = 1 kv H7 H M3007 Rated current of the h.v.h.b.c. fuse mind. (A)** max. (A) 0 1 0 0 315 0 0 0 0 00 1 00 delayed* delayed*, Type SSK 0, Type SSK 1, Type SSK circuit-breaker * Tripping delay of the switch: ms +0/- ms ** only recommended when l.v.h.b.c. fuse is installed on the low voltage side. 9

High-voltage high breaking capacity fuse link for Ur = kv Fitting dimensions of fuses e = -1 mm Possible application of the switch-fuse combination Rated voltage U r = kv H7 / H9 H M3007 delayed* delayed* Rated current of the h.v.h.b.c. fuse mind. (A)** max. (A) 0, Type SSK 1, Type SSK circuit-breaker * Tripping delay of the switch: 0 ms +0/- ms ** only recommended when l.v.h.b.c. fuse is installed on the low voltage side. High-voltage high breaking capacity fuse link for Ur = 36 kv Fitting dimensions of fuses e = 7-1 mm Ratedtransformerpower [kva] 0 1 0 0 315 0 0 0 0 00 1 00 00 31 Ratedtransformerpower [kva] 0 1 0 0 315 0 0 0 0 00 1 00 00 31 00 Possible application of the switch-fuse combination Rated voltage U r = 36 kv H9 H M3007 delayed* delayed* Rated current of the h.v.h.b.c. fuse mind. (A)** max. (A) 0 circuit-breaker * Tripping delay of the switch: 0 ms +0/- ms ** only recommended when l.v.h.b.c. fuse is installed on the low voltage side.

Thermal protection All DRIESCHER h.v.h.b.c. fuses with a release force of N and a rated current of up to 0 A are equipped with thermal protection as standard. This thermal protection is for preventing impermissibly high temperatures developing in insulated or gas-insulated switchgears. Important: Incorrect assignment of the h.v.h.b.c. fuses for the equipment to be protected (e.g. transformer) can lead to faults if a) the fuse is rated too low, through partial break of the fuse element as a result of the starting current inrush which, with auto-reclose, can occur several times in succession in an uncontrolled manner, b) the fuse is rated too high, in that when a short circuit occurs on the transformer low-voltage side (between transformer connection and low-voltage protection) or permanent overload of the transformer, the current flowing through the h.v.h.b.c. fuse is below its minimum breaking current. In these and other cases the thermal protection devices release the striker pin and trip the associated switch usually a load-break switch before the temperatures at the fuse reach a value endangering the thermal strength, of the porcelain tube, for example: Testing cartridge Testing cartridges are used to test the mechanical function of switch disconnectors with mounted high-voltage high breaking capacity fuses and striker in the dead condition. The dimensions are the same like the original high-voltage high breaking capacity fuses according to DIN 36. The release is effected through pressing the push button 1 what causes the ejection of the striker with a release force of 70 N and a path length of 30 mm. During this functional test it is ensured that high-voltage high breaking capacity fuses with a release force of N and a path length of 35 mm are able to release a switch-fuse combination safely and properly. After each release the striker has to be pushed in again. 1 The testing cartridges are clearly marked and have a plastic tube instead of a porcelain tube. Caution! Only use testing cartridges in the dead condition! To keep the release force of the testing cartridges constant for years, it is necessary to store them in a released condition (with released striker). Since April 1st, 03 all testing cartridges are marked through a fabrication number. The corresponding test badge shows the date the testing cartridge has to sent back to the factory for being newly calibrated. Testing cartridge 1 kv kv 36 kv Part No. 77 130 77 130 77 13060 Weight approx. [kg] 3, 5 11

Bypass tubes 1-36 kv For use in place of h.v.h.b.c. fuses. Dimensions according to DIN 36; up to I r max. 300 A Part No. Rated voltage I r Drawing No. 77 1130 1 kv HE -8 77 11 1 kv with heat shrink tube HE -8 77 130 kv HE -8 77 1 kv with heat shrink tube HE -8 77 1330 36 kv HE -8 Holder for 3 x h.v.h.b.c. fuses 6-30 kv, made of hot-galvanised steel plate Fuse holders Part No. 773 600 Drawing No. HH -13 Fuse extension Extensionadapter for h.v.h.b.c. fuses Part No. Rated voltage I r Drawing No. 790 0 from kv to kv HB-611 790 300 from kv to 30 kv HB-611 790 300 from kv to 30 kv HB-611 Fuse tongs The fuse tongs are suitable for specified use (VDE 05) for switchgears according to DIN VDE 01 and EN 671-0. The narrow and symmetrical head of the tongs permits the use of the tongs in small-scale panels. The tongs must be kept in a dry place which is free from dust. Part No. Rated voltage I r Type Drawing No. Length 77 11 77 11 77 11 up to 30 kv up to 30 kv up to 30 kv straight straight angled HE-986 HE-986 HE-3 mm 60 mm 1 mm Dimensions, weights, diagrams and descriptions in this brochure are n-binding. Subject to change without tice. switching electricity safely Printed on chlorine free bleached paper. For nature s sake. ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-866 MOOSBURG TEL. +9 87 61 6 81-0 FAX +9 87 61 68 11 37 http://www.driescher.com infoservice@driescher.de Order No. 3-817091 03-11