Electrical Actuators

Similar documents
Electric actuators for small valves

Electromotoric Actuators

Actuators for small valves

Electromotoric actuators

Electromotoric Actuators

Electromotoric Actuators. for zone valves VVI46.., VXI46.., VVS46.. and VXS46..

2-Port and 3-Port Zone Valves, PN16

Electromotoric Actuators

2-position electric actuators with Ball valves VBZ ½...11/4

2-Port and 3-Port Zone Valves, PN 16 / 20

3-port seat valves, external thread, PN16

3-Port Seat Valves with Male Thread, PN 16

Electromotoric Actuators

2-Port and 3-Port Zone Valves PN 16

2-Port and 3-Port Zone Valves & Actuators, PN16

Two-port and three-port small valves PN16, ANSI Class 250

3-Port Seat Valves with Male Thread, PN 16

2-port and 3-port valves with T-bypass PN 16

2-Port and 3-Port Zone Valves PN 16

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

2-port and 3-port terminal unit valves PN16

Butterfly valves, PN6, PN10, PN16

2-Port Seat Valves with Flange, PN 25

Electromotoric actuators

3-port seat valves PN16 with flanged connection

Electro-hydraulic actuators for valves

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

Butterfly valves PN 16

Butterfly valves PN6, PN10, PN16

Two-port seat valves with male thread, PN16

VMP43... Two-port and three-port seat valves PN16. Siemens Building Technologies Landis & Staefa Division

Modulating control valves with magnetic actuators, PN 16

2-port ball valves with flanged connection, PN25

Electromotoric Actuators

3-Port Seat Valves with Flange, PN 6

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

3-Port Seat Valves with Flange, PN 10

Butterfly valves PN 16

3-port seat valves PN10 with flanged connection

3-port seat valves PN16 with flanged connection

Modulating Control Valve PN 16 with Magnetic Actuator

3-port seat valves PN40 with flanged connection

2-port seat valves PN16 with flanged connection

Electromotoric Actuators

Power consumption In operation At rest For wire sizing

Modulating control valves with magnetic actuator PN 16

SQL35.00 SQL85.00 SQK angle of rotation

3-port seat valves PN6 with flanged connection

2-Port Seat Valves with Flange, PN 25

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Three-port slipper valves PN10, female-threaded

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

Differential Pressure Sensors

Overview of types. Technical data. Safety notes

MXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products

Actuators for Fire Protection Dampers

Power consumption In operation At rest For wire sizing

SAX Electronic Valve Actuator

Technical data. Safety notes

Differential Pressure Sensors

Differential Pressure Sensors

SAV Electronic Valve Actuator

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Butterfly valves PN6, PN10, PN16

Differential Pressure Sensors

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Actuators for air dampers and control valves of oil burners

Operating instruction Refrigerant Valves PS45

Modulating control valve PN16 with magnetic actuator

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

2-port seat valves PN25 with flanged connection

Actuators for air dampers and control valves of oil burners

Air damper actuators

2- and 3-port valves with flanged connections, PN 16

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Actuators for Fire and Smoke Protection Dampers

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Power consumption In operation At rest For wire sizing

Modulating control valves with magnetic actuator PN 16

3-port valves vxf42..

Electro-hydraulic actuators for valves

2-port and 3-port ball valves PN 40

Differential Temperature Controller

2- and 3-port valves with flanged connections, PN 16

Modulating control valves with magnetic actuators, PN 16

Air damper actuators

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Differential pressure sensor

Condensation monitor

Open/close ball valves 2-port and changeover ball valves 3-port, PN40

Modulating control valve with magnetic actuator PN16

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

VLF45... Hot Air Valves. Building Technologies Division

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Floating Control

GDB..3..1A GLB..3..1A

Transcription:

OEM Electrical Actuators SSY319 for valves VXG48, VXB489R, VXI48 VVP459, VXP459, VMP459, VVG549 AC 230 V operating voltage, 3-position control signal Positioning force 300 N Manual override with indication of current position and direction of travel Force-dependent switch-off in both end positions and in the event of overload For direct mounting with coupling nut, no tools required Plug-in connecting cable Anti-locking, maintenance-free gear train Use For operation of Siemens 2-port and 3-port valves with a nominal stroke of 55 mm for water-side control of hot water and cooling water in heating, ventilation and air conditioning systems CE1Q4899en 12122003 Siemens Building Technologies HVAC Products

Type summary Type reference Operating voltage Positioning time at 50 Hz Positioning signal Connecting cable SSY319 AC 230 V 150 s 3-position 15 m SSY319/30 30 m Accessories Type reference ASY98 Description Retaining screw for cable connector Ordering Delivery Example: When ordering, please give quantity, product name and type reference 10 actuators, type SSY319 The minimum order quantity is 10 actuators The actuators are delivered in multipacks of 10 together with the associated cables Mounting Instructions are enclosed Equipment combinations Type Valve type k vs PN class Data Sheet reference [m 3 /h] VXG48 3-port valves 63 20 PN16 N4467 VXB489R 16 16 Q4491 VXI48 4 16 Q4849 VVP459 2-port valves 063 25 VXP459 2-port valves 063 25 VMP459 3-port valves with T-bypass 063 4 Q4845 VVG549 2-port valves 025 63 PN25 Q4380 k vs = nominal flow rate of cold water (530 C) through the fully open valve (H 100 ), at a differential pressure of 100 kpa (1 bar) Other combinations are available on request Technical design / mechanical design When the actuator is driven by a 3-position signal, it produces a stroke which is transmitted to the valve stem The description of operation in this document applies to those versions of the valve which close when deenergized (NC) 3-position signal Voltage at Y1: Stem extends: Valve opens Voltage at Y2: Stem retracts: Valve closes No voltage at Y1 or Y2: Actuator maintains its current position 2/6 HVAC Products 12122003

Accessories Retaining screw 4899Z01 Type ASY98 to secure cable connector b c d The cable connector snaps into position, but can be additionally secured with the retaining screw 4899Z02 Notes Engineering Mounting The admissible temperatures (refer to «Technical data») must be observed The connecting cable of the actuator may come into contact with the hot valve body without harm, provided the temperature of the valve body does not exceed 90 C Mounting Instructions 4 319 5623 0 are enclosed with each multipack Assembly is made with the coupling nut; no adjustments are required The actuator should be installed so that it is initially in position 0 (also refer to «Manual override»): Position the actuator and tighten the coupling nut manually Orientation 90 90 4899Z03 Commissioning Caution Check wiring Check functioning of the actuator: Actuator stem extends (position indicator from position 0 to 1): Valve opens Actuator stem retracts (position indicator from position 1 to 0): Valve closes The actuator must only be operated in conjunction with a correctly mounted valve! Owing to the stroke / force-dependent switch-off feature, the correct operation of the actuator is only assured when mounted on the valve 3/6 HVAC Products 12122003

Manual override Note The actuator can be adjusted manually to any position between 0 and 1 However, if the actuator receives a positioning signal from the controller, this will take precedence in determining the position To retain the manually set position, unplug the connecting cable or disable the positioning signal Maintenance Repairs Disposal A (Y1) A B 4899Z04 B (Y2) A 4899Z05 Position indicator in position 1: Valve fully open B 4899Z06 Position indicator in position 0: Valve fully closed When servicing the SSY319 actuator, make sure that power is disconnected (eg remove the plug) The SSY319 actuators cannot be repaired; they must be replaced as complete units The actuators include electrical and electronic components and must not be disposed of together with domestic waste Current local legislation must be observed Warranty The technical data relating to specific applications is valid only in conjunction with the Siemens valves listed in this Data Sheet under «Equipment combinations» The use of these SSY319 actuators with third-party valves invalidates any warranty offered by Siemens Building Technologies / HVAC Products 4/6 HVAC Products 12122003

Technical data Power supply Rated voltage AC 230 V ± 15 % Rated frequency 50 / 60 Hz Power consumption 6 VA Fuse protection for incoming cable (fast) 2 A Control Positioning signal 3-position Operating data Positioning time for 55 mm stroke 150 s Nominal stroke 55 mm Nominal force 300 N Perm temperature of medium in the connected valve 1+110 C Electrical connections Connecting cable SSY319 SSY319/30 15 m 3-core to EN 60320 / IEC 60227 30 m 3-core to EN 60320 / IEC 60227 Industry standards Meets the requirements for CE marking: EMC directive 89/336/EEC Emissions EN 50081-1 Immunity EN 61000-6-2 73/23/EEC EN 60730-1 Low voltage directive Protection class II to EN 60730 Housing protection standard IP40 to EN 60529 Dimensions / weight Dimensions refer to «Dimensions» Coupling thread to valve coupling nut, G 3/4" Weight 03 kg Housing Cover Base plastic / anthracite, RAL 9011 plastic / light gray, RAL 7035 General ambient conditions Operation IEC 721-3-3 Transport IEC 721-3-2 Storage IEC 721-3-1 Environmental conditions Class 3K3 Class 2K3 Class 1K3 Temperature +1+50 C 25+70 C 5+50 C Humidity 585 % rh < 95 % rh 595 % rh Connecting cable N Y1 Y2 4899Z07en 7 6 4 white black blue Y2 Control signal CLOSE (AC 230 V) Y1 Control signal OPEN (AC 230 V) N Neutral 5/6 HVAC Products 12122003

Dimensions All dimensions in mm 93 G 3/4" 255 34 83 69 9 83 4899M01 48 R12 4899M02 6/6 2003 Siemens Building Technologies Ltd Subject to alteration HVAC Products 12122003