Leakage rate. Valve body. U.S. Registered Trademark EN0B-0308GE51 R1002 Copyright 2002 Honeywell Inc. All rights reserved

Similar documents
V5832A/5833A,C SMALL LINEAR VALVES PN16 FOR MODULATING AND ON/OFF-CONTROL SPECIFICATIONS

V5822A / 5823A,C SMALL LINEAR VALVES PN16 FOR MODULATING AND ON/OFF-CONTROL SPECIFICATIONS GENERAL

V5822A/5823A,C/V5832A/V5833A,C

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN40 TO DN50)

V5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

2, 3 and 4 - way valves VZL

M4410C/L SMALL LINEAR THERMOELECTRIC ACTUATORS

2-port and 3-port valves with T-bypass PN 16

3-Port Seat Valves with Flange, PN 6

3-Port Seat Valves with Flange, PN 10

3-port seat valves PN10 with flanged connection

MT4-024/MT4-230 MT8-024/MT8-230

VVP45 and VXP45 Series Two-port and Three-port Seat Valves ANSI Class 250 Short-stroke Valves

MT4-024/MT4-230 MT8-024/MT8-230

VB-9313 Series. Application. Features. Applicable Literature

3-port seat valves PN6 with flanged connection

CONTROL EQUIPMENT STAZ-16, STBZ-16

ELECTRIC ACTUATORS 400 N

VG4000 Series VG4000 Electric Zone Valves

V5049A FLANGED LINEAR VALVE PN25/40

VBF2, VBF3 Control Ball Valves With Flanged Connections

VBN2, VBN3 Control Ball Valves With Threaded Connections

Two-port and three-port small valves PN16, ANSI Class 250

Connection and regulation kit for HVAC terminal units

M7410E SMALL MODULATING LINEAR VALVE ACTUATOR

1 DESCRIPTION 2 WORKING PRINCIPLE 2.1 REGULATION ST

3-port seat valves, external thread, PN16

M7410E SMALL MODULATING LINEAR VALVE ACTUATOR

G3 (D) 3-way Globe Valve, Bronze Trim

VBN2, VBN3 Control Ball Valves With Threaded Connections

VG6000. Globe Valves Series for Terminal Units. Product Bulletin

VB-9313 Series. Application. Features. Applicable Literature

3-port seat valves PN16 with flanged connection

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

2-port and 3-port terminal unit valves PN16

FEATURES APPLICATION PRODUCT DATA

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

2-Port and 3-Port Zone Valves, PN16

3-Port Seat Valves with Male Thread, PN 16

599 Series Zone Valve Bodies:

V5013B,C,F Three-Way Mixing and Diverting Valves

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves

VE VVG Series Electronic Two-way Valves Normally Closed

2-Port and 3-Port Zone Valves PN 16

3-port valves vxf42..

VB-9213 Series. Application. Features. Applicable Literature

SELECTION. Easily Selectable Easily Serviceable. Interchangeability as easy as 1-2-3

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves

3-Port Seat Valves with Male Thread, PN 16

ROTARY MOTORIZED VALVES

G7 (S) 3-way Mixing Flanged Globe Valve, Bronze or Stainless Steel Trim

V5000. Globe Valves Series for Terminal Units. Product Bulletin

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

Data Sheet T EN

ZTV/ZTR. Externally threaded 2- and 3-way zone valves. Function. No leakage in closed position

3-port seat valves PN16 with flanged connection

2-Port and 3-Port Zone Valves PN 16

Pressure independent balancing and control valve

VBN2, VBN3 Control Ball Valves With Threaded Connections

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

3-port seat valves PN40 with flanged connection

M x Series Cast Iron Flanged Valve Linkage Kit for M9000 Series Electric Actuators

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves

VE-S_15-32 Pressure Independent Balancing & Control Valves

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

VG9000 Flanged Valves

MVN Rotary Valve Actuators FOR CONTROL BALL VALVES VBG (DN15 TO DN32)

Electro Controls. Valves / Linkages WattsIndustries.co.uk

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

VGF Flanged Globe Valves

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

Erie VT/VS PopTop Series Two Position Spring Return Valves

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

B2 Series Characterized Control Valve, Non-Spring Return Actuator

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

Valve Series V2001 Three-way Valve Type 3323

Flowrite VF 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE

Fan-coil valves Series

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

Three-port slipper valves PN10, female-threaded

ML7420A/ML7425A,B. Honeywell. Electric Linear Valve Actuator FEATURES SPECIFICATIONS GENERAL SPECIFICATION DATA

T Series (NPT) 2-Way and 3-Way Terminal Unit Zone Valves 1/2 3/4" 1. Applications. Features. Terminal Unit Zone Valves (NPT)

MT4-024/MT4-230 MT8-024/MT8-230

599 Series Zone Valve Bodies:

KTM MODEL NB / MB THREE-WAY BALL VALVES 2-SEATS (L-PORT) AND 4-SEATS (L AND T-PORT)

Seated valves (PN 16) VRG 2 2-way valve, external thread VRG 3 3-way valve, external thread

3 & 4-Way Rotary Valves

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

2-port ball valves with flanged connection, PN25

VG1000 Series Forged Brass Ball Valves

VB-7000 Series 1/2 to 2 Globe Valves

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

VE-x Plug & Seat Valve Assemblies

Transcription:

V5832/58,C SMLL LINER VLVES PN16 FOR MODULTING ND ON/OFFCONTROL V5832 V58 SPECIFICTION DT FETURES Small size allows installation where space is limited Long stroke results in a high quality characteristic Soft seat provides low leakage rate and high rangeability Reduced k VS values in the bypass to facilitate hydronic balancing Range of fittings available for different connections (soldered, threaded) djustment cap for manual operation Flat surfaces on body to fit installation tools Flat sealing connections in standard sizes Valve inserts changeable without draining by using insert replacement tool WV 108 40 mm distance between ports / and the bypass (V58C, only) V58C GENERL These small linear valves are used in combination with small electric linear valve actuators and thermoelectric actuators for the control of hot and/or chilled water for fan coil units and small reheaters/recoolers in electric/electronic temperature control systems. SPECIFICTIONS Models Operation Nominal pressure rating Twoway V5832 Threeway V58 Threeway with bypass V58C Twoway stem up to open, port to ; Threeway stem up to close, port to PN16 Capacity index (k VS) see tables on page 2 and 3 Leakage rate 0.02% of k VS Valve body Material rass Size DN15 (1/2 ), (3/4 ) Trim Stem Plug Suitable medium Stainless steel rass Controlled water temperature 2...120 C Water, with max. 50% glycol U.S. Registered Trademark EN00308GE51 R1002 Copyright 2002 Honeywell Inc. ll rights reserved

Modulating valves Rangeability Twoway valves 100:1 Threeway valves 100:1 for controlled port Flow characteristic Equal percentage port, linear for bypass port Stroke 6.5 mm On/Off valves Stroke 2.5 mm Dimensions see Fig. 4 on page 5 FLOW CPCITIES ND CLOSE OFF PRESSURE RTINGS TWOWY VLVES Valve DN k VS Order number M6410C,L/M7410C,E (180 N) CloseOff Pressure (kpa) with ctuators M4450/M8450 (90 N) Z100/M7410 (90 N) 15 0.16 V58321004 1600 600 15 V58321012 1600 600 15 V58321020 1600 600 15 V58321038 1600 600 15 V58321046 1200 180 15 V58321053 1200 180 20 V58321061 400 50* 20 V58321079 400 50* 15 V58324008** 1200 180 180 20 2.50 V58324016** 400 50* 50* *Up to 1000kPa system pressure. **For on/off control, stroke 2.5mm. THREEWY VLVES Valve CloseOff Pressure (kpa) with ctuators DN k VS k VS M6410C,L/M7410C,E M4450/M8450 Z100/M7410 Order Number (180 N) (90 N) (90 N) 15 0.25 0.16 V581003 800 500 15 0.40 0.25 V581011 800 500 15 0.63 0.40 V581029 800 500 15 1.00 0.63 V581037 250 150 15 1.60 1.00 V581045 250 150 20 2.50 1.60 V581052 100 50 20 2.50 1.60 V583009 240 20 4.00 2.50 V581060 100 50 20 4.00 2.50 V583017 240 15 1.60 1.60 V584007* 250 150 150 20 2.50 2.50 V584015* 100 50 50 *For on/off control, stroke 2.5mm. EN00308GE51 R1002 2

THREEWY VLVES WITH YPSS Valve CloseOff Pressure (kpa) with ctuators DN k VS k VS M6410C,L/M7410C,E M4450/M8450 Z100/M7410 Order Number (180 N) (90 N) (90 N) 15 0.25 0.16 V58C1066 800 500 15 0.40 0.25 V58C1009 800 500 15 0.63 0.40 V58C1017 800 500 15 1.00 0.63 V58C1025 250 150 15 1.60 1.00 V58C10 250 150 20 2.50 1.60 V58C1041 100 50 20 2.50 1.60 V58C1140 240 20 4.00 2.50 V58C1058 100 50 20 4.00 2.50 V58C1152 240 15 1.60 1.60 V58C4003* 250 150 150 20 2.50 2.50 V58C4011* 100 50 50 *For on/off control, stroke 2.5mm. OPERTION builtin return spring in the twoway valve produces an opening force. In the threeway valve and the threeway valve with bypass, the spring produces a closing force on the to ports. The valves are supplied with a screwedon adjustment cap for manual operation and for protection of the stem. This allows the stem to be set up for filling or initial heating/cooling during the building construction phase without the use of a controller or actuator. The small electric valve actuators as well as the thermoelectric actuators provide automatic control over the opening and closing movement of the valve stem. TYPICL OPERTION ll types of valves should be mounted in the return flow. If the pvalues exceed 60 kpa, attention should be paid to the development of noise. TwoWay Valves Direction of flow always from port to port Port : Outlet ThreeWay Valves These valves are preferably used as mixing valves, this means: Port : Total flow outlet Port : Controlled flow Port : ypass Fig. 2. Threeway valve operation ThreeWay Valves with ypass These valves simplify the installation, which is depending on the layout of the pipework, as the bypass pipe is part of the valve. The information for the normal threeway valves is also valid for this type. outlet outlet Fig. 1. Twoway valve operation Fig. 3. Threeway valve with bypass 3 EN00308GE51 R1002

MOUNTING When installing the valve care must be taken that the flow direction is correct (see section "Typical Operation"). The valve must not be mounted with the stem pointing downward. The adjustment cap must be removed from the valve only when the actuator is fitted. The valve should be installed as stressfree as possible with a tightening torque of 25 to 30 Nm. The valve is supplied complete with mounting instructions. The water quality must meet VDI 2035 requirements. CCESSORIES Valves V5832 need two connection sets, valves V58 three connection sets, and valves V58C four connection sets. Connection Pipe Size DN Order Number Connection Set Description Soldering 12 mm 15 mm 15 20 C15FS C20FS Consisting of 1 union nut, 1 solder bush, and 1 gasket External Thread R3/8" R1/2" 15 20 C15FT C20FT Consisting of 1 union nut, 1 tailpiece, and 1 gasket *Cannot be purchased from Honeywell Dimensions of Connection Sets a c d Order Number G1/2 G3/4 12 mm 15 mm C15FS C20FS G1/2 G3/4 R3/8 R1/2 C15FT C20FT EN00308GE51 R1002 4

DIMENSIONS Twoway valve 6. 5 Str ok e * 6.5 Stroke* 18 M30x1.5 llow 130mm for the actuator and clearance for removal a a b d d DN15 DN15 56 56 G1/2 34 34 66 11/8" x 14 S 84 66 G3/4 Threeway valve 6. 5 Str ok e * 6.5 Stroke* 18 M30x1.5 llow 130mm for the actuator and clearance for removal a a b b c dd DN15 DN15 56 56 G1/2 G1/2 24.5 34 34 66 66 11/8" G3/4 x 14 S 84 c a Threeway valve with bypass 6. 5 Str ok e * 6.5 Stroke* 18 M30x1.5 llow 130mm for the actuator and clearance for removal aa b b c c dd DN15 56 56 G1/2 40 403434 66 66 11/8" G3/4 x 14 S 84 40 40 * Modulating valves, only (in the case of on/off valves, the stroke amounts to 2.5 mm and the closure distance to 14 mm). Fig. 4. Dimensions V5832/V58,C in mm 5 EN00308GE51 R1002

V5832/V58,C SMLL LINER VLVE PN16 SPRE PRTS Valve inserts are provided as spare parts for the V5832 and V58,C small linear valves. When the tool WV 108 is used, the valve inserts can be changed without draining the system. Order Number DN k VS Order Number Valve Insert V58321004 15 0.16 0902812 V58321012 15 0.25 0902811 V58321020 15 0.40 0902810 V58321038 15 0.63 0902809 V58321046 15 1.00 0902808 V58321053 15 1.60 0902807 V58321061 20 2.50 0902814 V58321079 20 4.00 0902815 V58324008* 15 1.60 0902813 V58324016* 20 4.00 0902816 *For on/off control Order Number DN k VS Order Number Valve Insert V581003 / V58C1066 15 0.25 0902821 V581011 / V58C1009 15 0.40 0902822 V581029 / V58C1017 15 0.63 0902823 V581037 / V58C1025 15 1.00 0902824 V581045 / V58C10 15 1.60 0902825 V581052 / V58C1041 20 2.50 0902826 V583009 / V58C1140 20 2.50 0902818 V581060 / V58C1058 20 4.00 0902827 V583017 / V58C1152 20 4.00 0902819 V584007* / V58C4003* 15 1.60 0902817 V584015* / V58C4011* 20 2.50 0902820 *For on/off control The following valve inserts are interchangeable Twoway valves: k VS 0.16, 0.25, 0.40, and 0.63 k VS 1.0 and 1.6 k VS 2.5 and 4.0 Threeway valves: k VS 0.25, 0.40, 0.63, and 1.0 k VS 2.5 and 4.0 Control Products Honeywell G Hardhofweg D74821 Mosbach Phone: (49) 6261 810 Fax: (49) 6261 81309 http://europe.hbc.honeywell.com Subject to change without notice. Printed in Germany Manufacturing location certified to EN00308GE51 R1002