COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

Similar documents
Effective November 2016 Supersedes September 1998 (S )

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

Effective June 2016 New Issue

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

Effective March 2015 Supersedes S August 2012

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

High-voltage primary bushings installation instructions

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

Effective May 2017 Supersedes December 2004 (S )

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

Factory Authorized Mechanism Enhancement (FAME)

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

Figure 1. Kearney Type HX cutout.

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

CCP2-FLR1-21_ flange-rod operating mechanism

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Two-way cable interlock kit for Magnum fixed circuit breakers

3-way multi-family drawout cable interlock kit - type 32 - RF

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

COOPER POWER SERIES. Externally fused block banks installation instructions. Capacitors MN230004EN

Effective October 2016 Supersedes January 2014 (S )

Two-way cable interlock kit for Magnum drawout circuit breakers

Instruction Booklet IB E. Contents

O & M Manual for the EATON Generator Ready Loadcenter

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

COOPER POWER SERIES. Types VWE, VWVE27, VWVE38X, WE, WVE27, and WVE38X; threephase electronically controlled; installation and operation instructions

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Flush Mount AIN ALPHA Meters. General. Hardware Kit

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Instructions for using Functional Test Kit on Digitrip 520 and 1150 family of Power Circuit Breaker Trip Units and Series G and FD MCCB Trip Units

Advanced Test Equipment Rentals ATEC (2832)

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

CM52 Network Protector with Arc Flash Reduction Module

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

II DISTRIBUTION & SUBSTATION TYPE C

S Voltage Regulators. Contents. QD3 Quik-Drive Voltage Regulator Tap-Changer Manual. Figure 1B. QD3 Tap-changer. Figure 1A. QD3 Tap-changer.

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

600 A 15 and 25 kv class Cleer grounding elbow

Edison modular fuse, vault application products

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

Installation Instructions For Motor Control Center (MCC) Units

SPX9000 FR10 FR12 Adjustable Frequency Drives

600 A 28 kv class Cleer loadbreak connector system

BlinkerBeam Solar Controller

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

BSPA Type 1 and Type 2 surge protective devices

FCB-450, LCB-600, MCB-800

COOPER POWER SERIES. RVAC Fluid-insulated Vacuum Switchgear; Installation, Operation, and Maintenance Instructions. Switchgear MN285005EN

Magnum Breaker Remote Racking Device (MRR1000)

Installation Power Management Unit Battery Cables and Battery Harness

ELB ELB

COOPER POWER SERIES. Type MOST Fluid-Insulated Switchgear; Installation, Operation, and Maintenance Instructions

Transcription:

Voltage Regulators MN225064EN Effective March 2017 Supersedes October 2011 (S225-60-12) Testing a motor capacitor on a voltage regulator procedure instructions COOPER POWER SERIES

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. procedure instructions MN225064EN March 2017 i

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... i Safety for life... iii Safety information... iii Safety Instructions... iii Product Information.... 1 Introduction...1 Standards...1 Procedure description.... 1 Procedure instructions... 1 ii procedure instructions MN225064EN March 2017

SAFETY FOR LIFE Safety for life Eaton s Cooper Power series products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our Safety For Life mission. SAFETY FOR LIFE Safety information The instructions in this manual are not intended as a sub stitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians, who are familiar with this equipment should install, operate and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER will result in death or serious injury. could result in death or serious injury. CAUTION could result in minor or moderate injury. CAUTION could result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with high voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply may result in death, severe personal injury and equipment damage. Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. procedure instructions MN225064EN March 2017 iii

Testing a motor capacitor on a voltage regulator procedure instructions Product Information Introduction Service Information MN225064EN provides instruction for testing a motor capacitor on a voltage regulator. Refer to MN225003EN, CL-7 voltage regulator control installation, operation, and maintenance instructions and MN225008EN, VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation and Maintenance Instructions for detailed service information on Eaton s Cooper Power series voltage regulators and controls. Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment. Additional Information These instructions cannot cover all details or variations in the equipment, procedures, or processes described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. For additional information, contact your Eaton Cooper Power series product representative. Standards ISO 9001 Certified Quality Management System Caution Electrical Shock Hazard. Contact with terminals on the backpanel may expose the tester to 120 VAC resulting in an electrical shock. Figure 1. Standard dead-front back panel, tb1 located at top of control box. Figure 2. Alternate short back panel, tb3 located at bottom of control box. Procedure description If the motor capacitor is located in the control box, it can be removed from the circuit and tested using a voltmeter with a capacitance setting. The procedure described here is for testing a motor capacitor that is located in the tank and not accessible. Procedure instructions 1. The motor capacitor can be checked using either internal or external power. 2. Connect a voltmeter between TB1-R1 (TB3-R1 on the alternate short back-panel) and Ground. 3. Toggle the Control Function switch to Manual. 4. Using the Raise/Lower switch, give the tap-changer a Raise signal while observing the voltmeter. The voltmeter should read approximately 120 volts. 5. Connect the voltmeter between TB1-L1 (TB3-L1 on the alternate short back-panel) and Ground. 6. Using the Raise/Lower switch, give the tap-changer a Raise signal while observing the voltmeter. The voltmeter should read approximately 120 volts plus the capacitive voltage and should be between 160 and 190 volts. If the voltmeter reads zero volts or millivolts, the capacitor has failed open. 7. To recheck the results, connect the voltmeter between TB1-L1 (TB3-L1 on the alternate short back-panel) and Ground. 8. With the Control Function switch on Manual, give the tap-changer a Lower command using the Raise/Lower switch while observing the voltmeter. The voltmeter should read approximately 120 volts. 9. Connect the voltmeter between TB1-R1 (TB3-R1 on the alternate short back-panel) and Ground. 10. Using the Raise/Lower switch, give the tap-changer a Lower signal while observing the voltmeter. The voltmeter should read approximately 120 volts plus the capacitive voltage and should be between 160 and 190 volts. If the voltmeter reads zero volts or millivolts, the capacitor has failed open. 1 procedure instructions MN225064EN March 2017

Testing a motor capacitor on a voltage regulator procedure instructions 11. If a voltage is present between R1 and Ground or L1 and Ground that is more than millivolts without giving a raise or lower signal, either the capacitor or motor has failed shorted or there is some other type of short or wiring problem. If a cause cannot be found in the control panel or back panel, an outage is required to remove the voltage regulator from service. 12. If the motor capacitor has failed open and is located inside the tank, it can be temporarily replaced using the instruction found in the document MN225063EN, External application of a motor start capacitor on a single-phase voltage regulator. Contact your Eaton Cooper Power series product representative to request further assistance. Figure 4. Control panel switches. Figure 3. Legacy back panel, tb1 located at top of control box. procedure instructions MN225064EN March 2017 2

SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. MN225064EN / Rev. 0 March 2017 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.