TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Similar documents
TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

UPS Multi Sentry 10-20kVA

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

set out in standard IEC EN ). Multi Sentry is designed and built using state-of-the-art technology and components.

Master Plus kva

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE

Master Plus kva

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online

Master DIALOG INDUSTRY RANGE

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

SIRIUS Online UPS. data CeNTReS. TeleCoMMUNICATIoN devices. MedICAl devices. emergency devices. TRANSPoRTATIoN. Smart Energy Solutions

SR series. on-line

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Technical data sheets

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Technical Data Sheets

Technical Data Sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

TECHNICAL DATA SHEET KVA UPS Systemss

MKN-DSP SERIES - THREE PHASE

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

PowerValue 11/31 T kva

EFFEKTA Power Supplies

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

POWER kva

PowerWave 33 Efficient power protection for today s IT and process-related work environments

PowerScale TECHNICAL SPECIFICATIONS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

MASTERYS IP+ 10 to 80 kva

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

UPS Multi Power 1-28 x 42 kw up to 1MW

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

PowerScale kva Technical Specifications

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Industrial PFC UPS System

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

ConceptpowerTM Modular kVA

Green Power 2.0 MASTERYS GP

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

60 to 160 kva.

1.1 GENERAL CHARACTERISTICS

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

SENTINEL VA

Master MPS kva kva 3:1 3:3 VFI TYPE

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Specification SENTINEL PRO

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

» Sophisticated» Reliable» Intelligent

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

POWERTRONIX QUASAR 5-40 KVA

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

D Series: UPS UPTO - 300KVA - Three / Three Phase

TLE Series UPS 400/500 kw With eboost Technology

YOUR POWER IN SAFE HANDS. E Series UPS

Multi Sentry kva kva. 3: kva 1:1 3:3 VFI TYPE. Large power size selection 10, 12, 15, 20 kva Small footprint. Zero impact source

Technical data sheets

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Phase Modular Finally the benefits of Modular ups are for all

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

TLE Series UPS 160/200/225/250 kw with eboost Technology

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Technical Specifications SAFEPOWER-EVO-HF 10/15/20/30/40 kva three-phase input/three-phase output

Three Phase UPS Systems Range: 10 to 500kVA

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Transcription:

LOCAL Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms) Multi Sentry 10-20 kva Single-phase 10-120 kva Three-phase 6 Highlights Complete power range from 10 up to 120 kva Small footprint High efficiency up to 96,5% Zero Impact Source Advanced communication The MULTI SENTRY series is ideal for protecting data centre and telecommunications systems, IT networks and critical systems where poor power quality can lead to a loss of operations and service. The MULTI SENTRY series is available in 10-12 15-20 kva models with three-phase and single-phase input and single-phase output, and 10-12-15-20-30-40-60-80- 100-120 kva models with three-phase input and output with On-line double conversion technology, according to the VFI-SS-111 classification, as defined in IEC EN 62040-3. MULTI SENTRY: designed and built using state of the art technology and components, and controlled by the DSP (Digital Signal Processor) microprocessor, to provide maximum protection to the powered loads with no impact on downsteam systems and optimise energy savings. Its highly flexible design allows full compatibility both with three-phase and single-phase power supplies. 58

Zero impact source Thanks to the technology used, MULTI SENTRY solves installation problems in systems where the power supply has limited installed power, where the UPS is also powered by a generator or where there are compatibility problems with loads that generate harmonic currents; MULTI SENTRY has zero impact on its power source, being either the mains power supply or a generator: input current distortion of less than 3% Input power factor 0.99 power walk-in function that ensures a progressive start-up of the rectifier start-up delay function, to restart the rectifiers when mains power is restored if there are several UPS in the system. In addition, MULTI SENTRY plays a filter and power factor correction role in the power network upstream of the UPS, as it eliminates harmonic components and the reactive power, generated by the powered utilities. High output Using state-of-the-art technologies three-level NPC inverters have been designed which ensure a high output of up to 96.5%. These technology solutions allow for a saving of more than 50% of the energy dissipated in a year, compared to a similar product on the market with 92% output. The exceptional performance makes it possible to recover the initial investment cost in less than three years of operation. Battery care system Proper battery care is critical to ensuring the correct operation of a UPS in emergency conditions. The Riello UPS Battery Care System consists of a series of features and capabilities that allow for battery management in order to obtain the best performance possible and extend their operating life. Battery charging: MULTI SENTRY is suitable for use with hermetically sealed lead-acid (VRLA), AGM and GEL batteries and Open Cup and Nickel Cadmium batteries. Depending on the battery type, different charging methods are available. One-level voltage recharge, typically used for more common VRLA AGM % Efficiency 100 98 96 94 92 90 88 86 84 82 80 78 76 0 20 30 40 60 80 100 120 batteries Two-level voltage recharge according to IU characteristic Charge block system to reduce electrolyte consumption and further extend the life of VRLA batteries. Compensation of recharge voltage as a function of the temperature in order to prevent excessive charges or battery overheating. Battery tests to quickly diagnose any reduction in performance or problems with the batteries. Protection against deep discharges: during extended low-load discharges, the end-of-discharge voltage is increased as recommended by the battery manufacturers, to prevent damage to or decreased performance of the batteries. Ripple current: the recharge ripple MST 40 Traditional UPS 40kVA % load (residual AC component) current is one of the most important causes of a reduction in reliability and battery life. Thanks to a high frequency battery charger, MULTI SENTRY reduces this value to negligible levels, prolonging battery life and maintaining high performance over a long period of time. Wide voltage range: the rectifier is designed for operation with a wide range of input voltage values (up to - 40% at half load), reducing the need for battery discharge and thus helping to battery extend life. Maximum reliability and availability Connect up to 6 units in redundant (N+1) or parallel configuration. The UPS continues to operate in parallel even in UPS www.riello-ups.com 59

the event of an interruption in the connection cable (closed loop). Low management cost The technology and the choice of high performance components, allows MULTI SENTRY to achieve exceptional performance and output, with an extremely compact overall size smallest overall footprint is only 0.26sqm for MULTI SENTRY 20kVA with batteries the type of input stage ensures a power factor close to 1 and low current distortion without adding bulky and expensive filters output power at 0.9 power factor that provides up to 15% more active power than a standard UPS on the market, guaranteeing a greater margin in UPS sizing for potential load increases. Flexibility MULTI SENTRY is suitable for use in a wide range of applications, thanks to its configuration flexibility, accessories and options, and performance: suitable for powering capacitive loads, such as Blade servers, without any reduction in active power from 0.9 lead to 0.9 lag (% PA UPS) P Q 100 80 60 40 20 % PA 0 20 40 60 80 100 (% PA UPS) P Q CAPACITIVE PF 0.9 e.g.: 10 kva UPS powers 9 kw load PF 1 e.g.: 10 kva UPS powers 9 kw load 25 50 75 100 (% P UPS) P PF 0.9 e.g.: 10 kva UPS powers 9 kw load INDUCTIVE On-line, Eco, Smart Active and Stand By Off operating modes that are compatible with compatible with applications for centralised power systems (CSS). frequency converter mode configurable EnergyShare sockets to ensure backup for the most critical loads or those programmed to operate only when mains power fails Cold Start to switch on the UPS even when there is no mains power MST/MSM version: cabinet (1320x440x850mm HLW) for optimised solutions when medium to long-term runtime is required. optional temperature sensor for external battery cabinets, to assist the recharge voltage compensation additional battery chargers to optimise charge time optional dual input to mains power supply isolation transformers to vary neutral connectivity in the event of separate power sources or for galvanic isolation between input and output battery cabinets of different sizes and capacities, for providing extended runtimes. Advanced communication MULTI SENTRY is equipped with a graphic display (240x128 pixel backlit) that provides UPS information, measurements, status, and alarms in different languages and displays wave forms and voltage/current. The default screen shows the status of the UPS graphically indicating the status of the various blocks (rectifier, batteries, inverter, bypass). Advanced multi-platform, communication for all operating systems and network environments: PowerShield 3 supervision and shutdown software for Windows operating systems 7, 2008, Vista, 2003, XP, Linux Mac OS X, Sun Solaris, Linux, Novell and other Unix operating systems. Compatible with the Riello TeleNetGuard service RS232 serial port or USB 3 slots for the installation of optional communications accessories like network adapters, voltage-free contacts etc. REPO Remote Emergency Power Off for switching off the UPS with the remote emergency button Input for the connection of the auxiliary contact of an external manual bypass Input for synchronisation from an external source Graphic mimic panel display for remote connection. 60

battery box UPS MODELS BB 1320 480-T4 / BB 1320 480-T5 BB 1320 480-T2 / AB 1320 480-T5 BB 1600 480-S5 / AB 1600 480-S5 BB 1900 480-V6 / BB 1900 480-V7 / BB 1900 480-V8 BB 1900 480-V9 / AB 1900 480-V9 MODELS UPS up to 60 kva up to 80 kva up to 120 kva Dimensions (mm) 1320 1600 1900 400 815 650 750 860 800 details MST 100-120 (front) EnergyShare SOCKET PARALLEL REPO - AS400 USB - RS232 PARALLEL MST 60-80 (front) REPO - AS400 USB - RS232 MSM 10-20 MST 10-40 (front) MCM 10-12 - 15-20 MCT 10-12 - 15-20 (rear) BATTERY FUSES EnergyShare SOCKETS REMOTE CONNECTOR AND CONTACTS PARALLEL SERIAL PORT RS232 USB PORT MANUAL (OPTIONAL) MANUAL MANUAL MULTICOM 382 AUXILIARY BOARD SLOT IEC AUXILIARY SOCKETS (OPTIONAL) www.riello-ups.com 61

MODELS MCM/MSM 10 MCM/MSM 12 MCM/MSM 15 MCM/MSM 20 380-400-415 Vac three-phase with neutral / 220-230-240 single-phase 40 72 Hz Power factor at full load 0.99 Current distortion thdi 3% BY PASS 220-230-240 Vac Number of phases 1 Voltage tolerance 180 264 V (selectable) (selectable) ±5 (selectable) Nominal power (kva) 10 12 15 20 Active power (kw) 8 9.6 12 16 Power factor 0.8 Number of phases 1 (V) 220-230-240 Vac (selectable) Static variation ± 1% Dynamic variation ± 3% Crest factor (Ipeak/Irms) 3 : 1 Voltage distortion < 1% with linear load / < 3% with non-linear load Frequency Frequency stability during battery operation 0.01% Overload at Pf 0.8 110% for 10 minutes, 133% for 1 minute, 150% for 5 seconds BATTERIES Type VRLA AGM/GEL Charging time 6 hours INFO FOR INSTALLATION Weight without internal batteries (kg) (MCM/MSM) 80/105 82/110 90/115 95/120 Dimensions (hwd) (mm) 930 x 320 x 840 (MCM version) 1320 x 440 x 850 (MSM version) Communication 3 slot for communications interface /RS232/USB Ambient temperature 0 C / +40 C Relative humidity 90% non-condensing Colour Dark grey RAL 7016 Noise level < 52 dba a 1 m Protection level IP20 Smart Active Output up to 98% Regulations Directive EMC 2004/108/CE Electromagnetic Compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS 111 62

MODELS 10 12 15 20 MST 30 MST 40 MST 60 MST 80 MST 100 MST 120 380-400-415 Vac three-phase with neutral 40 72 Hz Power factor at full load 0.99 Current distortion thdi 3% BY PASS 380-400-415 Vac three-phase with neutral Number of phases 3 + N Voltage tolerance 180 264 V (selectable) (selectable) ±5 (selectable) Nominal power (kva) 10 12 15 20 30 40 60 80 100 120 Active power (kw) 9 10.8 13.5 18 27 36 54 72 90 108 Power factor 0.9 Number of phases 3 + N (V) 380-400-415 Vac (selectable) Static variation ± 1% Dynamic variation ± 3% Crest factor (Ipeak/Irms) 3 : 1 Voltage distortion 1% with linear load / 3% with non-linear load Frequency Frequency stability during battery operation 0.01% Overload at Pf 0.8 115% unlimited, 125% for 10 minutes, 150% for 1 minute, 168% for 5 seconds BATTERIES Type VRLA AGM/GEL Charging time 6 hours INFO FOR INSTALLATION Weight without internal batteries (kg) () 80/105 82/110 90/115 90/115 135 145 190 200 370 380 Dimensions (hwd) (mm) 930 x 320 x 840 (versione MCT) 1320 x 440 x 850 (versione MST) 1320 x 440 x 850 1600 x 500 x 850 1900 x 750 x 855 Communication 3 slot for communications interface /RS232/USB Ambient temperature 0 C / +40 C Relative humidity 90% non-condensing Colour Dark grey RAL 7016 Noise level < 52 dba a 1 m < 48 dba a 1 m < 52 dba a 1 m < 65 dba a 1 m Protection level IP20 Smart Active Output up to 99% Regulations European directives L V 2006/95/CE Low Voltage Directive EMC 2004/108/CE Electromagnetic Compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS 111 UPS www.riello-ups.com 63