When the RF Stim Unit is fully charged, the status light on the RF Stim Unit will be solid GREEN.

1. Connect the Tester to the L300 FS Cuff plug holes. See Figure Figure 11-1: Tester connected to the L300 FS Cuff.

Setting Up the NESS L300 Plus System

Charging the NESS H200 Wireless System

Manufactured by Bioness Neuromodulation Ltd. A Bioness Inc Company 19 Ha Haroshet Street PO Box 2500 Industrial Zone Ra Anana 43654, Israel

Rx Only Rev. C

Vercise TM DBS Charging Handbook

Model: SL360R Lithium Ion 360 LED Cordless Work Light

Setting Instructions for Movement Caliber B230 Contents

Installation Instructions. Ventvisor Deflector

Product Data Sheet : LIGHTHAWK 6 CELL

EK1240KL Battery-powered Crimping Tool

MULTI-FUNCTION JUMP STARTER

Step1: Battery and Speaker Assembly Step 2: Pump and Battery Installation Step 3: Setting Up Your Fountain 6 Troubleshooting and Maintenance

Rx Only Bioness Inc Rev. C 07/2017

Cybex Arc Trainer Owner s & Service Manual. 7 - Service

58kHz AM Deactivator DB104 Instruction Manual V1.0

Questions - usage (EN) ENGLISH. - How can I avoid getting the headband cords tangled? Stow your lamp as indicated in the drawing below.

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

WELDING HELMET INSTRUCTIONS. Part #20520

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

BodyGuardTM 323. BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump. Patient Guide

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

6 Bay Battery Charger Operation Manual

EDITION : A. Description: SCALE : 100% (L4 FFL-201 ANZ) manual artwork PART NO COLOR ITEM ID. MATERIAL 50gsm recycle paper REV.

innovations in battery charging

Pistol Grip Battery-powered Pressing Tool

SRK12KX Battery-powered Crimping Tool

Resuscitation System Model 100

Car Battery Charger Instructions for Use

USER MANUAL MPS 1-5KW SERIES

Wheel Arch Trim Set. Installation Manual. This section covers installation of the wheel arch trim set.


100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

NILFISK BA 500 Service Manual

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

RECHARGEABLE POWER OUTAGE LED LIGHT INSTRUCTION MANUAL

LS100L Battery-powered Punch Driver

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

Garden Planter. Owner s Manual. Self-Watering. with optional legs

Instruction manual DENVER DBO

Trek Lync Supplement to owner s manual

BATTERY CHARGER Instruction Manual

LED Twister II. User manual UK Version 1.0

DIAGNOSTIC POWER SUPPLY WSC 720. user guide. 12 V/24 V lead acid batteries ah

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Motion System Components Diagram. Note: #2 Mirror Cover and X-Axis Motor Cover have been removed for visibility. Maintenance.

16" STAND FAN WITH REMOTE

This chapter describes how to perform periodic inspection and maintenance to ensure the long operating life of the chamber.

Item #21484 XL VIEW AUTO DARKENING WELDING HELMET INSTRUCTIONS

Item #21483 LARGE VIEW AUTO DARKENING WELDING HELMET INSTRUCTIONS

WELCOME TO THE STEALTH REVOLUTION!

Memory Foam Massaging Bath Pillow with Wireless Remote Control

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Parts missing or damaged? Questions? Toll-free Helpline

BlueFin User's Manual. Version 1.1

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

Marin Control Digital

82V LITHIUM-ION BATTERY CHARGER GC 400

Battery Safety Instructions 4 Garden Fountain Parts List 7 Step1: Battery Installation 8 Step 2: Setting Up Your Fountain 11

The Chameleon Trac II Patent Pending M-Series User s Manual

AquaLift Bath Lift System MODEL #8100

with Touch & Go Feature

M

Service Manual CDFI1000P CDFI500P

Lemania/EnergyFlo Start booster X7

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

AUTO CHARGE D PUMP PLUS

60V RECHARGEABLE LITHIUM-ION BATTERY

Sherman + Reilly Battery-powered Pistol Grip Cable Cutters

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

EASY CHARGE Weather-resistant fixed mount Battery Charger

USER'S GUIDE 9151 SERIES V

USER GUIDE 12 V Lead acid batteries Ah

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

OPERATING INSTRUCTION D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HOLIDAY DETECTOR

Car Jumpstarter. Powerbank mah EMERGENCY BACK-UP PEAK CURRENT 650A

J5242.

Cellular Shades MOTORIZED SHADE Top Down - Bottom Up. Installation & Care Instructions

GATOR Battery-powered Pistol Grip Cable Cutters

SR500 PAPR How to Copyright 2015 by The S.E.A. Group 1

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

INSTALLER MANUAL USER MANUAL. Contents

Polar WearLink 31 CODED TRANSMITTER. User Manual. Gebrauchsanleitung. Manuel d'utilisation. Gebruiksaanwijzing. Manuale dell utente

ReadyPay tm Power System User Manual

Motorized Skylight Installation Instructions

WGCT-A & WGCT-A/E TO REDUCE THE RISK OF INJURY, USER MUST READ INSTRUCTION MANUAL

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

The Bio Tuner. Model BT6pro Manual. Contents Welcome to SOTA... 2 Before Using... 2 Learn More... 2 Complete unit includes... 2 do not use...

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

Language specific user manuals are available on

TUTTLE & BAILEYR. Installation & Service Manual PRODUCT DIMENSIONS. FIGURE 1 - Product Isometric and Dimensional Views

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

OPERATOR S MANUAL SINGLE PORT UNIVERSAL CAR CHARGER

Transcription:

Maintenance and Cleaning 8 Charging the Batteries When a system component has a low battery, the Control Unit will beep and the component indicator light will flash YELLOW. See Table 5. When the RF Stim Unit battery is low, the RF Stim Unit status light will also flash YELLOW. When the Intelli-Sense Gait Sensor battery is low, the Control Unit low-battery audio alert will become more persistent as the battery weakens. Display Definition Low Battery: Control Unit Flashing YELLOW Low Battery: RF Stim Unit Flashing YELLOW Flashing YELLOW Low Battery: Intelli-Sense Gait Sensor Table 5: Low battery displays and definitions. Chapter 8 - Maintenance and Cleaning 33

To charge the batteries in the Control Unit and RF Stim Unit: 1. Open the cover of the charging ports (found at the bottom of the Control Unit and at the top of the RF Stim Unit). See Figure 13. Cover RF Stim Unit Charging Port Control Unit Charging Port Cover Figure 13: RF Stim Unit and Control Unit charging ports. Caution: The batteries must be charged before first use, daily, and after extended storage. Caution: Only the Control Unit and RF Stim Unit batteries are rechargeable. Caution: Remove the FS Cuff before charging the batteries. Caution: Do not use the RF Stim Unit or Control Unit while charging. 34 User s Guide

2. Connect the system charger set to the Control Unit and RF Stim Unit. See Figure 14. System Charger Set Note: 0.6-cm (1/4-in.) gap is normal Figure 14: Charging set-up. 3. Plug the system charger set into a wall socket. 4. Verify that the rotating GREEN circle appears in the Control Unit digital display, and the status light on the RF Stim Unit is alternately flashing YELLOW and GREEN. See figures 15 and 16. Note: It is possible to charge the Control Unit and RF Stim Unit separately, but Bioness recommends that the Control Unit and RF Stim Unit be charged at the same time. Chapter 8 - Maintenance and Cleaning 35

5. The charging process will continue until a horizontal GREEN line appears in the Control Unit digital display and the RF Stim Unit status light is solid GREEN. See figures 15 and 16. The charging process should last approximately three hours. The Control Unit and RF Stim Unit can remain connected to the charger after charging is complete. Note: If the Control Unit battery is completely discharged, a b (for boot) will flash for a few seconds in the Control Unit digital display when charging is started. Rotating GREEN Circle: Control Unit Charging Horizontal GREEN Line: Control Unit Fully Charged Figure 15: Control Unit charging displays. Status Light Alternately Flashing GREEN and YELLOW: RF Stim Unit Charging Status Light Solid GREEN: RF Stim Unit Fully Charged Figure 16: RF Stim Unit charging displays. 36 User s Guide

Replacing the Batteries RF Stim Unit Battery The RF Stim Unit rechargeable battery should be replaced approximately every two years by a Bioness certified technician. Intelli-Sense Gait Sensor Battery The battery in the Gait Sensor is not rechargeable. It should be replaced approximately every six months. The Gait Sensor indicator on the Control Unit will begin to flash YELLOW approximately two weeks before the Gait Sensor completely loses its charge. The Control Unit will also emit an alarm. To install a new Gait Sensor battery (Lithium coin cell, CR2430): 1. Unscrew the two screws from the battery cover. See Figure 17. Screws Battery Cover Note: If you are unable to replace the battery yourself, your local watchmaker or battery supply store should be able to assist. Figure 17: Replacing the Gait Sensor battery. Chapter 8 - Maintenance and Cleaning 37

2. Slide the cover out. 3. Note the + orientation of the old battery. 4. Remove the old battery and properly dispose of it according to your local environmental regulations. 5. Insert the new battery. The + should face outward. 6. Slide the cover back into place, and tighten the screws. 7. Press the Gait Sensor pressure sensor to activate the sensor. Remove the old battery, and properly dispose of it according to your local environmental regulations. Control Unit Battery The battery in the Control Unit is a rechargeable AAA battery. It should be replaced approximately every two years. To install a new Control Unit battery (AAA NiMH 1.2 V): 1. Remove the screw from the battery cover on the back of the Control Unit. See Figure 18. (The screw may be under a small label. If so, gently peel off one end of the label. Reapply the label after the battery is replaced.) 2. Remove the battery cover. 3. Note the "+/-" orientation of the old battery. 38 User s Guide

4. Insert the new rechargeable battery in the proper "+/-" orientation. 5. Slide the cover into place, and tighten the screw. 6. Fully charge the new battery before first use. Caution: Use of a non-rechargeable AAA battery can damage the Control Unit. Battery Battery Cover Screw Control Unit Note: If you are unable to replace the battery, your local watchmaker or battery supply store should be able to assist. Figure 18: Replacing the Control Unit battery. Remove the old battery, and properly dispose of it according to your local environmental regulations. Chapter 8 - Maintenance and Cleaning 39

Replacing the Hydrogel Electrodes You will need to replace the electrodes at least every two weeks. Caution: Use only NESS L300 electrodes supplied by Bioness. Caution: Do not use your NESS L300 without electrodes. To replace the hydrogel electrodes: 1. Turn off the Control Unit. 2. Gently pull the used electrodes from the electrode bases. Be careful not to detach the electrode bases from the FS Cuff. See Figure 19. 3. If necessary, clean the electrode bases with a damp cloth. Do not use a chemical-based cleaning substance. Electrode Base Figure 19: Removing the used hydrogel electrodes from the hydrogel electrode bases. 40 User s Guide

4. Separate the two new electrodes along the perforation. See Figure 20. Figure 20: Separating the new hydrogel electrodes. 5. Split the two-piece covers on each new electrode and discard them. See Figure 21. Figure 21: Splitting the hydrogel electrode two-piece covers. Chapter 8 - Maintenance and Cleaning 41

6. Attach the grid side of the electrodes to the electrode bases, and then press firmly. See Figure 22. Figure 22: Attaching the grid side of the hydrogel electrodes to the electrode bases. 7. Remove the covers from the electrodes. See Figure 23. Figure 23: Removing the covers from the hydrogel electrodes. Note: Save the covers. Always reapply the covers between uses. When reapplying the covers, make sure the Bioness logo faces up. Note: If the electrode gel becomes dry, rehydrate it with one to two drops of water. 42 User s Guide

6. Attach the grid side of the electrodes to the electrode bases, and then press firmly. See Figure 22. Figure 22: Attaching the grid side of the hydrogel electrodes to the electrode bases. 7. Remove the covers from the electrodes. See Figure 23. Figure 23: Removing the covers from the hydrogel electrodes. Note: Save the covers. Always reapply the covers between uses. When reapplying the covers, make sure the Bioness logo faces up. Note: If the electrode gel becomes dry, rehydrate it with one to two drops of water. 42 User s Guide

Replacing the Cloth Electrodes Cloth electrodes and cloth electrode bases are an option for those who experience a skin sensitivity to the hydrogel electrodes. First fittings will be done by your clinician. Afterward, you will need to change the cloth electrodes at least every two weeks and the cloth electrode bases every one to two years. Caution: Use only NESS L300 cloth electrodes supplied by Bioness. Caution: Do not use your NESS L300 without electrodes. To replace the cloth electrodes: 1. Turn off the Control Unit. 2. Gently pull the used cloth electrodes from the cloth electrode bases. Be careful not to detach the cloth electrode bases from the FS Cuff. See Figure 24. 3. If necessary, clean the cloth electrode bases with a damp cloth. Do not use a chemical-based cleaning substance. Figure 24: Removing used cloth electrodes. Chapter 8 - Maintenance and Cleaning 43

4. Wet the new cloth electrodes with tap water until they are saturated. See Figure 25. 5. With a soft cloth, gently wipe or blot excess water off the back (side with the snap) of the cloth electrodes. See Figure 26. 6. Attach the cloth electrodes to the cloth electrode bases. See Figure 27. Note: Remove and re-wet the cloth electrodes every time you remove the FS Cuff from your leg for more than one hour, and after every four hours of use. When wetting the cloth electrodes, always remove them from the FS Cuff. If the cloth electrodes dry out, your response to the stimulation may change. If you need to adjust stimulation intensity more often than usual, try re-wetting the cloth electrodes following the steps listed above. Figure 25: Wetting the cloth electrodes. 44 User s Guide

Figure 26: Blotting the snap side of the cloth electrodes. Figure 27: Attaching the cloth electrodes to the cloth electrode bases. Chapter 8 - Maintenance and Cleaning 45

Replacing the Electrode Bases If you are switching from hydrogel to cloth electrodes, or from cloth electrodes to hydrogel electrodes, you will need to be seen by a qualified clinician for a first fitting. Your clinician will need to fit the electrode bases and adjust your stimulation settings. Afterward you will need to replace the electrode bases after one to two years of use. Contact Bioness to purchase replacement electrode bases. To replace the electrode bases: 1. If your clinician installed wire concealers over the electrode base wires, remove the wire concealers. 2. Mark the position of the used electrode bases on the FS Cuff liner with a permanent marker. See Figure 28. Figure 28: Marking the position of the used electrode bases. Caution: When replacing the FS Cuff, have your clinician re-fit the electrodes and electrode bases. 46 User s Guide

3. Disconnect the electrode base snaps from the plug holes. See Figure 29. 4. Remove the used electrode bases from the FS Cuff. See Figure 30. Figure 29: Disconnecting the electrode base snaps. Figure 30: Removing the used electrode bases. Chapter 8 - Maintenance and Cleaning 47

5. Attach the new electrode bases where the previous bases were attached. See Figure 31. 6. Connect the electrode base snaps to the plug holes. See Figure 32. 7. Recover the wires and snaps with the wire concealers, if desired. Figure 31. Attaching the new electrode bases. Figure 32: Connecting the electrode base snaps to the plug holes. 48 User s Guide

Removing the RF Stim Unit The only time you should remove the RF Stim Unit is to clean the FS Cuff or replace the RF Stim Unit. To remove the RF Stim Unit: 1. Turn off the Control Unit. 2. Pull the top of the RF Stim Unit away from the cradle. See Figure 33. If the fit is too tight, open the flexible cover over the charging port for a better grasp. 3. Remove the bottom of the RF Stim Unit from the cradle. Cradle Inserting the RF Stim Unit To insert the RF Stim Unit: RF Stim Unit Figure 33: Removing the RF Stim Unit. 1. Insert the bottom of the RF Stim Unit into the cradle. Then, gently push the top of the RF Stim Unit into the cradle until it snaps in. Chapter 8 - Maintenance and Cleaning 49

Cleaning Your NESS L300 Components All NESS L300 components may be cleaned by carefully wiping them with a damp cloth. The electrical components are not waterproof. Do not immerse them in water. The FS Cuff is the only component that can be immersed in water to clean. Bioness recommends cleaning the FS Cuff when replacing the hydrogel electrodes, so that the electrodes do not dry out. To clean the FS Cuff: 1. Remove the RF Stim Unit. 2. Gently remove the electrodes from the electrode bases. For hydrogel electrodes, replace the electrode covers. Do not remove the electrode bases. 3. Immerse the FS Cuff for 30 minutes in lukewarm water and mild detergent. Do not use a washing machine. 4. Rinse the FS Cuff thoroughly under running water. 5. Immerse the FS Cuff for an additional 15 minutes in clean, lukewarm water. 6. Rinse the FS Cuff again under running water. 7. Gently blot excess moisture from the FS Cuff with a towel. Do not wring the FS Cuff. Lay the FS Cuff flat in the shade to dry. (Do not hang dry.) Drying time will vary from 4 to 12 hours depending on climate and humidity. For faster drying, place the FS Cuff in front of a circulating cold-air fan. Do not use a hot-air dryer or other heat source to dry. 8. When the FS Cuff is completely dry, insert the RF Stim Unit and attach the electrodes. 50 User s Guide

Replacing the Cloth Electrodes Cloth electrodes and cloth electrode bases are an option for those who experience a skin sensitivity to the hydrogel electrodes. First fittings will be done by your clinician. Afterward, you will need to change the cloth electrodes at least every two weeks and the cloth electrode bases every one to two years. Caution: Use only NESS L300 cloth electrodes supplied by Bioness. Caution: Do not use your NESS L300 without electrodes. To replace the cloth electrodes: 1. Turn off the Control Unit. 2. Gently pull the used cloth electrodes from the cloth electrode bases. Be careful not to detach the cloth electrode bases from the FS Cuff. See Figure 24. 3. If necessary, clean the cloth electrode bases with a damp cloth. Do not use a chemical-based cleaning substance. Figure 24: Removing used cloth electrodes. Chapter 8 - Maintenance and Cleaning 43

4. Wet the new cloth electrodes with tap water until they are saturated. See Figure 25. 5. With a soft cloth, gently wipe or blot excess water off the back (side with the snap) of the cloth electrodes. See Figure 26. 6. Attach the cloth electrodes to the cloth electrode bases. See Figure 27. Note: Remove and re-wet the cloth electrodes every time you remove the FS Cuff from your leg for more than one hour, and after every four hours of use. When wetting the cloth electrodes, always remove them from the FS Cuff. If the cloth electrodes dry out, your response to the stimulation may change. If you need to adjust stimulation intensity more often than usual, try re-wetting the cloth electrodes following the steps listed above. Figure 25: Wetting the cloth electrodes. 44 User s Guide

Figure 26: Blotting the snap side of the cloth electrodes. Figure 27: Attaching the cloth electrodes to the cloth electrode bases. Chapter 8 - Maintenance and Cleaning 45

Replacing the Electrode Bases If you are switching from hydrogel to cloth electrodes, or from cloth electrodes to hydrogel electrodes, you will need to be seen by a qualified clinician for a first fitting. Your clinician will need to fit the electrode bases and adjust your stimulation settings. Afterward you will need to replace the electrode bases after one to two years of use. Contact Bioness to purchase replacement electrode bases. To replace the electrode bases: 1. If your clinician installed wire concealers over the electrode base wires, remove the wire concealers. 2. Mark the position of the used electrode bases on the FS Cuff liner with a permanent marker. See Figure 28. Figure 28: Marking the position of the used electrode bases. Caution: When replacing the FS Cuff, have your clinician re-fit the electrodes and electrode bases. 46 User s Guide

3. Disconnect the electrode base snaps from the plug holes. See Figure 29. 4. Remove the used electrode bases from the FS Cuff. See Figure 30. Figure 29: Disconnecting the electrode base snaps. Figure 30: Removing the used electrode bases. Chapter 8 - Maintenance and Cleaning 47

5. Attach the new electrode bases where the previous bases were attached. See Figure 31. 6. Connect the electrode base snaps to the plug holes. See Figure 32. 7. Recover the wires and snaps with the wire concealers, if desired. Figure 31. Attaching the new electrode bases. Figure 32: Connecting the electrode base snaps to the plug holes. 48 User s Guide

Removing the RF Stim Unit The only time you should remove the RF Stim Unit is to clean the FS Cuff or replace the RF Stim Unit. To remove the RF Stim Unit: 1. Turn off the Control Unit. 2. Pull the top of the RF Stim Unit away from the cradle. See Figure 33. If the fit is too tight, open the flexible cover over the charging port for a better grasp. 3. Remove the bottom of the RF Stim Unit from the cradle. Cradle Inserting the RF Stim Unit To insert the RF Stim Unit: RF Stim Unit Figure 33: Removing the RF Stim Unit. 1. Insert the bottom of the RF Stim Unit into the cradle. Then, gently push the top of the RF Stim Unit into the cradle until it snaps in. Chapter 8 - Maintenance and Cleaning 49

Cleaning Your NESS L300 Components All NESS L300 components may be cleaned by carefully wiping them with a damp cloth. The electrical components are not waterproof. Do not immerse them in water. The FS Cuff is the only component that can be immersed in water to clean. Bioness recommends cleaning the FS Cuff when replacing the hydrogel electrodes, so that the electrodes do not dry out. To clean the FS Cuff: 1. Remove the RF Stim Unit. 2. Gently remove the electrodes from the electrode bases. For hydrogel electrodes, replace the electrode covers. Do not remove the electrode bases. 3. Immerse the FS Cuff for 30 minutes in lukewarm water and mild detergent. Do not use a washing machine. 4. Rinse the FS Cuff thoroughly under running water. 5. Immerse the FS Cuff for an additional 15 minutes in clean, lukewarm water. 6. Rinse the FS Cuff again under running water. 7. Gently blot excess moisture from the FS Cuff with a towel. Do not wring the FS Cuff. Lay the FS Cuff flat in the shade to dry. (Do not hang dry.) Drying time will vary from 4 to 12 hours depending on climate and humidity. For faster drying, place the FS Cuff in front of a circulating cold-air fan. Do not use a hot-air dryer or other heat source to dry. 8. When the FS Cuff is completely dry, insert the RF Stim Unit and attach the electrodes. 50 User s Guide