A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

Similar documents
An Energy Efficiency Measurement Scheme for Electric Car Charging Pile Chun-bing JIANG

The Modeling and Simulation of DC Traction Power Supply Network for Urban Rail Transit Based on Simulink

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

China. Fig. 1 Chain SVG Electrical Diagram

Grounding systems for power supply facilities

Electrical Test of STATCOM Valves

China Electric Power Research Institute, Beijing, , China

HVDC. TMT&D provides the best and most economical HVDC system.

Design of Control System for Vertical Injection Moulding Machine Based on PLC

GB/T / IEC :2007

*Corresponding author. Keywords: Quick vacuum circuit breaker, Opening and closing coil, Repulsion mechanism, reliability.

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

An Alternative to Reduce Medium-Voltage Transient Recovery Voltage Peaks

Zero-turn-off thyristor zero voltage block media recovery analysis of influencing factors FANG Wei1, a*, XU Guo-shun1, b, ZHUANG Jin-wu1, c

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

A New Synthetic Test Circuit For the Operational Tests of HVDC Thyristor Modules

HIGH VOLTAGE MODULE TEST SYSTEM

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Protective firing in LCC HVDC: Purposes and present principles. Settings and behaviour. V. F. LESCALE* P. KARLSSON

Workbench Film Thickness Detection Based on Laser Sensor Mo-Yun LIU, Han-Bing TANG*, Ma-Chao JING, and Zhen ZHOU

Research on V2G Control Strategy for EV Charge and Discharge Equipment

Analysis and Design of the Super Capacitor Monitoring System of Hybrid Electric Vehicles

Impulse Voltage Test System, Q Structure, kV

Failure Modes and Effects Analysis for Domestic Electric Energy Meter Using In-Service Data

Design and Reliability of a High Voltage, high Current Solid State Switch for Magnetic Forming Applications

Performance Comparison and Selection of Transformer Fluid

Impact Analysis of Off-board Charger to Power Quality

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

The 1,400-MW Kii-Channel HVDC System

A starting method of ship electric propulsion permanent magnet synchronous motor

Integrated Monitoring System Design of Hybrid Aircompressors

Intelligent CAD system for the Hydraulic Manifold Blocks

A Device for Sorting and Recycling Dry Batteries Automatically Jiahang Xia

The Development of ±800kV/4750A UHVDC Valve & HVDC/FACTS Status in China. For EPRI HVDC & FACTS Conference Aug. 30, 2011 Palo Alto, California, USA

Passive Vibration Reduction with Silicone Springs and Dynamic Absorber

AMT Fault Diagnosis Technology Based on Simulink and LabVIEW

Common Bus and Line Regeneration

E-15 Uninterruptible Power Systems (UPS)

Current accuracy class. Sensor principles

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

(by authors Jouko Niiranen, Slavomir Seman, Jari-Pekka Matsinen, Reijo Virtanen, and Antti Vilhunen)

In-Motion Ultrasonic Testing of the Tread of High-Speed Railway Wheels using the Inspection System AUROPA III

Combination control for photovoltaic-battery-diesel hybrid micro grid system

Optimization of Three-stage Electromagnetic Coil Launcher

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Analysis and Design of Independent Pitch Control System

Performance study of combined test rig for metro train traction

High Power Semiconductor Devices and Solid State Switches for Pulsed Discharge Applications

Multi-axial fatigue life assessment of high speed car body based on PDMR method

Research on vibration reduction of multiple parallel gear shafts with ISFD

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Reliability Enhancement of HVDC Transmission by Standardization of Thyristor Valves and Valve Testing

SINAMICS GM150 IGCT version

Design and Application of Versatile Automatic Bin with Valve Splint Slide Way

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

The spray characteristic of gas-liquid coaxial swirl injector by experiment

A novel flux-controllable vernier permanent-magnet machine

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

Application of Phased Array Ultrasonic Testing Technology on Inservice Wheel

Investigation of Transient Recovery Voltage Across a Circuit Breaker with Presence of Braking Resistor

Isolated Bidirectional DC DC Converter for SuperCapacitor Applications

Evaluation of the Performance of Back-to-Back HVDC Converter and Variable Frequency Transformer for Power Flow Control in a Weak Interconnection

Fault Rid Through Protection of DFIG Based Wind Generation System

II. ANALYSIS OF DIFFERENT TOPOLOGIES

Design and experiment of hydraulic impact loading system for mine cable bolt

Reverse power relay and protection assemblies

Research on the charging system of electric vehicle photovoltaic cells HUANG Jun ( Hunan Railway Professional Technology College, Zhuzhou, )

Experimental investigation on vibration characteristics and frequency domain of heavy haul locomotives

A Novel Integration of Power Electronics Devices for Electric Power Train

Modelling and Simulation of DFIG with Fault Rid Through Protection

Comments on sub clause of IEEE draft 802.3bt/D2.4 Presenter: Arkadiy Peker Co-author : Yair Darshan May 15, 2017

DYNACOMP. The top-class reactive power compensator

Research on the supercapacitor support schemes for LVRT of variablefrequency drive in the thermal power plant

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

Simulation research on rail transit traction grid voltage stabilization and its energy saving effects based on BESS

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Transient reactive power characteristics of HVDC during commutation failure and impact of HVDC control parameters

Applications of Frequency Conversion Technology in Aircompressor

Pantograph and catenary system with double pantographs for high-speed trains at 350 km/h or higher

2nd International Conference on Electronic & Mechanical Engineering and Information Technology (EMEIT-2012)

IEEE Transactions on Applied Superconductivity, 2012, v. 22 n. 3, p :1-5

Next-generation SCADA and Control Technologies for Large-scale Use of Photovoltaic Generation on Electric Power Grid

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Technology and Application of Centralized DC Power Supply for LED Street Lamp

Analysis and Design of Improved Isolated Bidirectional Fullbridge DC-DC Converter for Hybrid Electric Vehicle

Advanced Protective Relay Training

Study on Braking Energy Recovery of Four Wheel Drive Electric Vehicle Based on Driving Intention Recognition

Outdoor vacuum breaker for railway applications - FSK II

W SERIES IMPULSE VOLTAGE TEST SYSTEM APPLICATION FEATURES

Forced vibration frequency response for a permanent magnetic planetary gear

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

The Testing and Data Analyzing of Automobile Braking Performance. Peijiang Chen

Increasing Wanzhou Power Transfer Capability by 550kV Fixed Series Capacitor FSC Fengjie

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Excitation systems for high power synchronous generators with redundant configurations

PSW102 type CT powered protection unit

Modern Applied Science

Transcription:

A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission Longchen Liu 1, Ke Yue 2, Lei Pang 2, Xinghai Zhang 1, Yawei Li 1 and Qiaogen Zhang 2 1 State Grid Sichuan Electric Power Research Institute, 610072 Chengdu, China 2 School of Electrical Engineering, Xi an Jiaotong University, 710049 Xi an, China Abstract. The converter valve is the core equipment in the HVDC power transmission system, a+-nd its performance has a direct effect on the reliability, stability and efficiency of the whole power system. As the basic unit of HVDC converter valve, the thyristor level needs to be test routinely in order to grasp the state of the converter valve equipment. Therefore, it is urgent to develop a novel synthetic test system for the thyristor level with thyristor control unit (TCU). However, currently there is no specific test scheme for the thyristor level of HVDC converter valve. In this paper, the synthetic test principle, content and methods for the thyristor level with TCU are presented based on the analysis of the thyristor reverse recovery characteristic and the IEC technology standard. And a transient highvoltage pulse is applied to the thyristor level during its reverse recovery period in order to test the characteristics of thyristor level. Then, the synthetic test system for the thyristor level is applied to the converter valve test of ±800 kv HVDC power transmission project, and the practical test result verifies the reasonability and validity of the proposed synthetic test system. 1 Introduction As the core element of HVDC converter valve, thyristor is massively adopted to transmit electric power energy because of its high power capacity. The converter valve usually consists of a large number of thyristor levels, which are connected in series. Each thyristor level needs to be test routinely during the maintenance period of electrical equipment in order to make sure that their electrical properties and functions are in normal state. Considering the large number of thyristors, there is a heavy workload of thyristor level test. Therefore, it is important to develop a synthetic test system for thyristor level in HVDC converter valve. As to electrical test of HVDC converter valve, IEC 60700-1-2008 and GB/T20992-2007 technology standard provide some relevant provisions [1, 2]. However, these provisions mainly focus on the type test, such as dielectric test and operation test. Although these standards provide some general descriptions for routine test (for instance, the inspections of wiring, equalizer circuit parameters and withstand voltage), corresponding scheme and specific content of judgement methods in the routine test are scarcely mentioned. To date, some researchers introduced and studied type test and operation test of the converter valve. Ding [3] and Luo et al. [4] studied type test of converter valve and provided specific experiment protocol, requirement and improvement plan [5]. Zha et al. [6, 7] and Hu et al. [8] studied operation test under various actual operating conditions. However, studies on in-situ routine test for thyristor level of converter valve are rare. Zha et al. [9] studied routine test and proposed a thyristor level unit routine test program, but failed to investigate the TCU testing. Some international companies developed comprehensive testing devices for in-situ synthetic test of thyristor level, for example ABB, Siemens and Alstom. Yet, the domestic standard of relevant routine test for converter valve products is still in preliminary stage [10-12]. Therefore, it is necessary to establish a routine synthetic test system for thyristor level, which can ensure the performance of thyristor level and provide technical support for the operation and maintenance of HVDC converter valve. Based on the analysis of the electrical principle and failure mode of thyristor level unit, this paper proposed a synthetic test scheme for in-situ routine test, and the synthetic test system is applied to the converter valve test of a practical ±800 kv HVDC power project. 2 Electrical structure and principles of thyristor level The converter valve is arranged in modules, which contains a large number of thyristor level units connected in series. As shown in Figure 1, thyristor level unit with TCU is the basic structural unit in converter valve, which consists of thyristor, damping circuit (R 1-6, C c1, C c2 ), equalizing circuit (R 41, R 42 ), thyristor control unit (TCU) and energy storage circuit for TCU (C 3, R 3 ). The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/).

R11 Cc1 Cc2 R14 R12 R15 R13 C3 R16 R3 R41 R42 TCU the main circuit, control unit, communication module, peripheral equipment interface circuit and the corresponding power distribution protection module. As shown in Figure 2, the main circuit of synthetic test system includes three circuit modules: fundamental frequency (50Hz) power supply module, high voltage impulse power supply module and high frequency sinusoidal wave signal generator, these three power modules can be switched by the time control of highvoltage relay. The electromagnetic interference (EMI) module in the figure is a filter, which is used to prevent electromagnetic interference. Main circuit Figure 1. Electrical diagram of thyristor level with TCU. Under the condition of inductive loads, reverse recovery overvoltage would be generated across the thyristor during the turn off process, which even exceeds the reverse repeat peak voltage of the thyristor and breaks the thyristor. Therefore, a parallel damping circuit is usually connected to the thyristor to absorb the reverse recovery charge and prevent the voltage overshot during the turn off process, which is shown in Fig. 1. TCU is the core component in thyristor level unit. Thyristor level unit is at a high potential, whereas the control module of the converter valve is at ground potential. Therefore, an electric isolation is required in the transmission of trigger signal. Optoelectronic isolation has been widely applied in electric isolation. Valve control unit (VCU) at ground potential converts the electrical trigger pulse, which is produced by the control module of the converter valve, into optical pulse and transmits this optical pulse to TCU by the optical fiber. TCU reconverts the optical pulse into electrical pulse, and transmits this electrical pulse signal to the gate pole of the thyristor. Then the thyristor is triggered. Except the normal trigger function described above, TCU includes two protective trigger circuits: the protective firing (PF) circuit and the recovery protection (RP) circuit. The working voltage of TCU is obtained by coupling the voltage of thyristor level unit. If the thyristor cannot be normally triggered, the forward voltage across the thyristor would continue to increase. In case that the forward voltage may exceed the rated value, PF circuit would send an emergency trigger pulse automatically in order to force the thyristor to be conducted, which avoids the thyristor being damaged. During the turn off process, TCU would detect the terminal voltage of the thyristor, and send an emergency trigger pulse to trigger the thyristor and prevent breaking if the disturbance voltage exceeds the rated value. 3 Research and development of synthetic test system for thyristor level 3.1 Electrical structure of synthetic test system Figure 2 shows the structure and principle of the synthetic test system for thyristor level of HVDC converter valve. The synthetic test system is composed of Electric Supply EMI Keyboard&Display I/O Control 50Hz power supply power supply High frequency sinusoidal signal Data acquisition CPU Test object Out Optical fiber Thyristor level TCU Communication module Figure 2. Diagram of test system for thyristor level of HVDC converter valve. The electrical structure of high voltage impulse power supply module is shown in Figure 3. This power supply module consists of seven parts: a bidirectional thyristor V 1, a boost transformer T 2, a controllable rectifier V 2, a RLC discharge circuit, a power electronic switch (V 3 ~V 6 ), a internal protection circuit (V 7 ~V 10 ) and a driving circuit (Q 3, Q 4 ). As shown in Figure 3(a), the switch S 2 is mainly used for switching power to different power modules; R 1 and R 2 is the protection resistance; the energy storage capacitor C 1 is charged through the boost transformer T 2 in order to get a high voltage impulse; the output voltage can be adjusted through changing the AC positive and reverse conduction angle of the bidirectional thyristor V 1, and the thyristor V 1 must be triggered on zero by control unit Q 2 to ensure the output waveform is a standard sine wave. In Figure 3(b), C 1 is the energy storage capacity; L is the inductance of RLC oscillation circuit; L 1 is used to adjust the impulse voltage waveform; L 2 is a key part of the discharge circuit; V 3 ~V 6 is used as a forward switch; and V 7 ~V 10 is the switch of discharge circuit. And the energy of high voltage impulse can be released through the loop V 7 ~V 10 -R 3 -R 4 -V 3 ~V 6. (a) 220V AC/50Hz R1 R2 S2 Q2 V1 T2 AC220/15K (a) High voltage rectifier circuit V2 HV(a) HV(b) 2

HV(a) (b) HV(b) C1 R3 Q3 R4 V3 V4 V5 V6 Q4 L1 V7 V8 V9 V10 (b) High voltage impulse circuit L2 Test object Figure 3. Electrical diagram of high voltage impulse power supply module. 3.2 Synthetic test contents of thyristor level By analyzing common faults of thyristor level unit, a test scheme of in-situ synthetic test is developed on the basis of its failure modes. Combing the standard IEC 60700-1 and the working principle, the test projects for the in-situ synthetic test of the thyristor level unit are developed. Items of the routine synthetic test are shown in Table 1. Table 1. Synthetic test items of the thyristor level. Test items with low voltage Impedance test Firing test 3.2.1 Impedance test Test items with high voltage TCU protective function test Reverse test Impedance test detects the short circuit or the open circuit within the voltage equalizing circuit and damping circuit. It is a low voltage test, the voltage of which does not reach thyristor turn on voltage, therefore the corresponding impedance is mainly refer to the impedance of capacitors and resistors within the equalizing and damping circuits. The circuit diagram of impedance test is shown in Figure 4(a), where the voltages with different frequencies generated by the sine wave generator are imposed on thyristor level unit. The peak voltage and current across the thyristor are measured during the test, and the impedances of the circuit under different frequencies are calculated. The obtained impedance is compared with the threshold, therefore the conditions of resistors and capacitors in the thyristor level unit can be evaluated. 3.2.2 Fire test Fire test detects whether TCU is able to respond properly to optical pulse signal and send a trigger pulse to the thyristor. The test circuit of fire test is shown in Figure 4(b), where AC circuit with power frequency applies a forward voltage to the thyristor, and the electronic power switch controls the phase angle. 3.2.3 TCU protective function test Ensure the performance of thyristor under the following conditions: (I) the thyristor suffers from an overvoltage exceeding the designed voltage threshold; (II) the thyristor is subjected to a transient forward impulse during its turn off process, the TCU should be tested by the PF and RF tests. In this study, RP test includes PRL tests and PRH tests. The parameters of impulse voltage used for RP test are shown in Table 2. PRL test is performed during the reverse recovery period of the thyristor. After the thyristor regain its reverse blocking ability, PRH test is performed. The test circuit of TCU protective function is shown in Figure 4(c). The AC circuit provides a normal forward voltage for the thyristor, and the impulse circuit generates a forward impulse voltage. The power electronic switch is able to forcedly cut off the on state current and control trigger phase angle. These three modules are putting into operation according to a predefined controlling sequence. Table 2. Parameters of the RP test. Test project Amplitude Time 3.2.4 Reverse test RPL 2 kv (t rr ) max + 50 μs RPH 10 kv 1.2(t rr ) max The blocking ability of the thyristor to reverse voltage can be evaluated through reverse test. The test circuit of reverse test is shown in Figure 4(d), where the impulse circuit provides a reverse voltage impulse, and the voltage divider is used to measure the impulse voltage. (a) (b) (c) (d) Sine-wave generator Power frequency AC circuit Power frequency AC circuit circuit Electronic power switch Electronic power switch Voltage divider circuit (a) Impedance test; (b) Fire test; (c) TCU protective function test; (d) Reverse test Figure 4. The synthetic test diagram of thyristor level. 4 Application of synthetic test system for thyristor level The synthetic test system was applied to the in-situ test of the KGWF03-5000/±800 thyristor level in the converter value of HVDC power transmission. The acceptance 3

standard and the interrelated technical regulations of the in-situ synthetic test are listed in Table 3, and the test results and analyses are presented as follows. Table 3. Technical specifications of ±800kV HVDC power transmission. Test items Acceptance criteria Impedance test 110Hz: 664~1727Ω 6000Hz: 26~36Ω Firing test U th : 32±10V U PF : 8050~8500V TCU protective function test U RPL : 1475~1775V U RPH : 8050~8500V Reverse test U REV : 8040~8340V Figure 5 shows the impedance test waveform. The PRL and RPH test worked on frequencies of 110 Hz and 6 khz respectively. The peak voltage and current of the thyristor were measured during the tests, and then the impedance under each corresponding frequency was calculated. The impedances in PRL and PRH test were 685Ω and 29Ω respectively, which met the requirements of the technical specifications. Figure 6. The waveform of fire test. Figure 7(a) shows the waveform of the PF test. When the impulse voltage reaches the protection threshold of TCU, TCU will send an emergency pulse to trigger the thyristor. The peak value of forward voltage was measured to be 8067 V when the thyristor was triggered by TCU. Figure 7(b) and 7(c) show the waveforms of the RPL and RPH test respectively. A power frequency voltage was applied to the thyristor, and then the reverse voltage turned off the thyristor. During the reverse recovery process, a low voltage impulse was applied through the impulse circuit at 1050 μs later than the moment when the thyristor voltage began to reverse. This action threshold of TCU was 1475~1775 V, and TCU operated when the impulse voltage was 1660 V. Figure 7(c) shows the thyristor voltage waveform of the RPH test. A high impulse voltage was applied by the impulse circuit at 1200 μs later than the moment when the thyristor voltage began to reverse. This action threshold of TCU is 8050~8500 V, and TCU operated when the impulse voltage was 8099 V. The TCU protective function met the technical requirements as expected. Figure 8 shows the waveform of the reverse test. Reverse voltage impulse was imposed on the thyristor, and ensure that thyristor breakdown would not take place. The protective circuit released the energy of high voltage impulse and protected the thyristor. The voltage peak value of reverse impulse on the thyristor was measured to be 8290 V. It was indicated that the reverse test passed. (a) 110Hz; (b) 6000Hz Figure 5. The waveform of impedance test. Figure 6 shows the waveform of the fire test. The thyristor level unit was imposed by a power frequency voltage. It can be found that TCU took the power and then triggered the thyristor. The measured voltage of the triggered thyristor was 35 V, which met the demand of technical specifications. 4

By analyzing the test waveforms above, the thyristor level unit of the HVDC converter value met the technical requirements and all tests passed, which proved and verified the reasonability and validity of the proposed insitu synthetic test system and method. 5 Conclusions In this paper, the in-situ synthetic test technology of thyristor level in HVDC converter valve was investigated. Through analyzing the structure and working principle of thyristor level in the converter valve, and combining with the technical standards IEC 60700-1-2008, the synthetic test content and method for the thyristor level with TCU was proposed. And the in-situ test of thyristor level included impedance test, fire test, TCU protective function test and reverse test. The in-situ synthetic test system was developed and applied to the thyristor level test of ±800kV HVDC converter valve in order to verify the rationality and validity of this test system and method. The test waveforms indicated the performance of thyristor level in the converter valve met the technical requirements of HVDC power transmission. The results showed that this test system and method was reasonable, and satisfied the demand of engineering applications. References (a) PF test; (b) RPL test; (c) RPH test Figure 7. The waveforms of TCU protective function test. Figure 8. The waveform of reverse test. 1. IEC60700-1. Geneva: International Electrotechnical Commission (2008) 2. GB/T 20992-2007. Chinese standard SN for books. Beijing: China Standard Press (2007) 3. Y. G. Ding, Electric Power Construction, 29, 2 (2008) 4. X. Luo, G. F. Tang, Power System Technology, 34, 5 (2010) 5. E. Nho, B. Han, Y. Chung, IEEE Transaction on power delivery, 27, 2 (2012) 6. K. P. Zha, J. L. Wen, Power System Technology, 34, 12 (2010) 7. K. P. Zha, C. Gao, Power System Technology, 36, 2 (2000) 8. Z. L. Hu, F. Xu, High Voltage Apparatus, 49, 4 (2013) 9. K. P. Zha, G. Y. Wang, High Voltage Engineering, 38, 11 (2012) 10. T. Bauer, H. P. Lips, IEEE Transaction on Power Delivery, 12, 3 (1997) 11. E. Nho, B. Han, Y. Chung, IEEE Transaction on Power Electronics, 29, 7 (2014) 12. G. F. Tang, K. P. Zha, IEEE Transaction on power delivery, 28, 3 (2013) 5