CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

Similar documents
Application Data CONTENTS. COMPRESSOR PHYSICAL DATA (Table 1) Table 1 Open-Drive Compressors

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

O6D AND O6E COMPRESSOR DATA AND ACCESSORY GUIDE

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

RCD Air Cooled Condensing Unit (50/60 Hz)

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

Low Profile Unit Coolers

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

LUI / LUO. Condensing Units

09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

50Hz ZBD45KCE-TFD R404A Dew Point

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

THINK COLD. THINK LARKIN. WAREHOUSE/INDUSTRIAL UNIT COOLER

YCUJ Millennium TM AIR COOLED CONDENSING UNIT

Air Cooled Condensing Units - Technical Catalog. Featuring CopelandTM Compressors 404A and 507 Refrigerants

SeasonPak Packaged Air-Cooled Water Chiller

CHP

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

DESCRIPTION FEATURES

TSA6. Product Specifications. SmartComfort TXC 5600

1/2-6 HP Air-cooled Condensing Units

McQuay Air-Cooled Reciprocating Chiller ALR

Remote Air Cooled Condenser

Refer to KP-525 for more information on compressor and performance data. Refer to KP-515 for more information on compressor and performance data

Air-Cooled Screw Compressor Chiller

High Profile Evaporator

BHH Product Specifications

CAS. Product Specifications

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

C O I L M A S T E R CMC-110

Center Mount Unit Coolers

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

CSA6. Product Specifications. SoftSound SXC 2600

Installation Instructions

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

N4A4 C. Product Specifications

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Installation, Start-Up and Service Instructions

Standard features. Optional features

High Profile Evaporator

AIR COOLED CHILLERS WATER COOLED CHILLERS

1/2 TO 6 HP INDOOR WATER COOLED CONDENSING UNITS

50Hz ZB76KCE-TFD R404A Dew Point

ACCESSORY KIT INSTALLATION INSTRUCTIONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

Installation, Start-Up and Service Instructions

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

H-MSTB January Replaces H-MSTB, Oct M Series. AIR-COOLED CONDENSING UNITS 1/2-6 HP Indoor and Outdoor Models. Technical Guide MOH MOZ MOS

A200 NEMA Contactors and Starters A200

1/2-6 HP Air-cooled Condensing Units

10AC DIPLOMAT SERIES RFC SYSTEMS

N4A6. Product Specifications

Doosan XHP1070WCAT Bid Specifications

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

WCA4**4. Product Specifications

HEAT PUMPS UPLB- SERIES. Seven Models

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT

Medium Profile Unit Coolers

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

Standard features. Optional features

CAS. Product Specifications

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

SARAVEL PACKAGED AIR-COOLED CONDENSING UNIT

Quantum Air REMOTE AIR COOLED CONDENSER

R4H4. Product Specifications

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

REMOTE AIR COOLED CONDENSERS

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

MEDIUM PROFILE UNIT COOLERS Technical Guide. Models HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost.

MAGNETIC MOTOR STARTERS

HEAT PUMPS UPKB- SERIES. Seven Models

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

Outreach Innovation Building Penn State Research Park State College, PA. Appendix E. Scroll Chiller Data. The Pennsylvania State University

Bitzer CSH Series To Fusheng

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

Eclipse 2000 Service Parts

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

Pathfinder Remote Evaporators

CS Series Condensing Units

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Transcription:

CARLYLE OPEN DRIVE S/ACCESSORIES SERVICE VALVES MANIFOLDS MANIFOLDS P77 SUCTION SERVICE VALVE 5F S 5F20-S674 06DA660063 06DA660062 5F20-A684 06DA660063 06DA660062 5F20-S684 06DA660063 06DA660062 5F30-Al89 06EA660090 06DA660065 5F30-S644 06EA660090 06DA660065 5F30-A219 06EA660090 06DA660065 5F30-S664 06EA660090 06DA660065 5F40-A219 06EA660090 06DA660065 5F40-S219 06EA660090 06DA660065 5F60-A219 5F660-002 5F660-001 5F60-S219 5F660-002 5F660-001 5H S 5H40-(+)219 5H660-008 5F660-002 5H46-(+)219 5H660-008 5F660-002 5H60-(+)219 06LA660010 06LA660010 5H66-(+)219 06LA660010 06LA660010 5H80-(+)219 06LA660010* 06LA660010 5H86-(+)219 06LA660010* 06LA660010 5H120-(+)219 06LA660011 06LA660011 5H126-(+)219 06LA660011 06LA660011 (+)May be either A (Remanufactured) or S (New Manufactured). These Models require a suction and a discharge manifold in order to mount the service valve. *Requires a suction valve adapter (: 5H660-006). Requires a discharge valve adapter (: 5H660-005). RELIEF VALVE KIT DISCHARGE SERVICE VALVE The Models listed require the addition of a suction and discharge manifold in order to mount the service valve. MUFFLERS SUCTION MANIFOLD DISCHARGE MANIFOLD 5F60-A219 5F60-1094 NONE 5H60,66 5H660-007 5H660-007 5H120,126 5H660-001 5H660-003 P75 P78 LENGTH (in.) CONN. SIZE (in.) MUFFLER 5F20 11-1/4 1-1/8 O.D.F 06DA605614 5F30,40,60 13-3/4 1-3/8 O.D.F 05HY500853 5H40,46,60,66 22-5/8 2-5/8 O.D.F 05HY500863 5H80,86,120,126 22-5/8 3-1/8 O.D.F 05HY501013 Relief Valve Kit P81 P78 Compressor Models 5H 120 & 126 Require the addition of a relief valve and associated piping. : 5H120-337 EXTERNAL UNLOADER CONVERSION KIT Kit is used to bypass the standard 5 line (5F40 thru 5H126) cylinder unloading system that responds to changes in suction pressure. A field supplied controller is used in conjunction with this kit to control solenoid valves that activate/deactivate cylinder unloaders. External capacity control results in more precise compressor capacity matching to the load. 5F40 5F40-4FI-A 5H60,66,80,86 5H60-4FI-A 5F60 5F60-4FI-A 5H120,126 5H120-4FI-A 5H40,46 5H40-4FI-A 5F Kits contain hand hole cover. 5H Kits contain blankoff plates. 120 Volt solenoid coils. 88

CARLYLE OPEN DRIVE S/ACCESSORIES CRANKCASE HEATERS CRANKCASE HEATER RELAYS P82 P85 LEAD SHEATH USED ON WATTS VOLTS LENGTH LENGTH (in.) (in.) 5F20,3,040,60 100 120 48 7 HT31AZ120 5F20,30,40,60 100 240 48 7 H731AZ240 5H40,46,60,66,80*, 86*,120*,126* 200 120 63 7 HT31AZ121 5H40,46,60,66,80*,16 *,120*,126* 200 240 63 7 HT31AZ241 *These Models Require Two Heaters. The Crankcase Heater Relay is used to energize the Heater when the compressor is not in operation. The Crankcase Heater Relay is not required when using 32 Series control panels. COIL VOLTS 120 HN61AJ101 240 HN61AJ108 5F/5H LUBE OIL CONTROL TIME DELAY 45 Seconds CONNECTIONS 36 Lg. Cap w/1/ 4 Fl. Nuts PRESSURE DIFFERENTIAL VOLTS RESET CUT-IN CUT-OUT KIT CONTROL ONLY 15-20 psi 11-15 psi 115/230 Manual 5F20-212 P529-4120 P83 OIL FILTER PACKAGE OIL COOLER PACKAGE P86 P84 Package Includes: (1) partial flow oil filter with fittings, (2) angle valves, tubing and (2) oil pressure gauges. All 5H120,126 are supplied standard with a full flow oil filter. USED ON All 5F 5F20-B103 5H40,46,60,66,80,86 5H40-B283 5H120,126 5H120-B283 Use on: 5H40, 46, 60, 66, 80, 86 compressor models : 5H40-A274 OIL FILTER ONLY......................... : 05HG660020 89

CARLYLE OPEN DRIVE S/ACCESSORIES CAPACITY CONTROL VALVE PACKAGE WATER-COOLED HEAD PACKAGE P87 P90 For use on 5F20,30 compressors. REFRIGERANT USAGE 5F20,30 R-12 5F20-752 5F20,30 R-22,R-502 5F20-A752 FELT FILTER KIT 5F S 5F20 5F20-172 5F30 5F30-172 5F40 5F40-172 5F60 5F60-172 5F S 5H40,46 5H40-507 5H60,66 5H60-507 5H80,86 5H80-507 5H120,126 5H120-507 Water Cooled Heads are required for compressors used on low temp R-22 applications. See Compressor Ratings on pages 4 & 5 for application ranges. The water cooled head packages listed contain the necessary heads, covers, gaskets, and fittings to convert standard 5F/H compressors to water cooled heads. P88 Felt Filters are installed in the compressor s suction strainer as a temporary clean up medium. NOTE: Filter Kit is included with service compressors. NO. FILTERS REQUIRED PER COMP. KIT FILTER ONLY 5F40,46 1 5F40-A352 5F40-3792 5F60,66 2 5F60-A352 5F60-3792 5H40,46 1 5H40-A382 5H40-4032 5H60,66 2 5H60-A382 5H60-4032 5H80,86 1 5H80-A382 5H80-4032 5H120,126 2 5H120-A382 5H120-4552 DOWEL PIN P91 Tapered dowel pin (no. 6 x 2-3/4 long) is used to maintain alignment and to ensure exact compressor/motor repositioning after service. Two Pins are required for both motor and compressor. (Pins for motor are included in motor fastening package.) : DRILL & REAMER KIT AX35AA238 Drill and reamer kit includes a 9/32 in. drill bit and a no. 6 taper reamer to facilitate installation of the no. 6 tapered dowel pin. : 5H40680004 P92 P89 VIBRATION ISOLATORS VIBRATION ISOLATORS limit the transfer of vibration. They are attached underneath the surface to which the compressor is mounted. Four isolators are supplied in each package. One for each corner of the unit. Associated hardware is also included. Select proper size isolator by dividing total unit weight by 4. 5F20-623 5F30-623 5F60-633 5F60-663 5H40-653 5H60-673 5H80-673 5H120-467 5H120-527 ISOLATOR LOADING 90 to 150 150 to 210 210 to 290 290 to 390 350 to 450 450 to 650 650 to 950 950 to 1250 1250 to 1550 LBS/ISOLATOR 90

CARLYLE OPEN DRIVE S/ACCESSORIES FLEXIBLE STEEL COUPLINGS FOR DIRECT DRIVE UNITS NOTE: A Dial Indicator must be used to properly align the compressor and motor shafts for reliable operation. P98 MOTOR H. P. MOTOR FRAME SIZE MOTOR SHAFT DIA. (in.) MAXIMUM COUPLING H.P. RATING WT. (lbs) 5F20,30 7-1/2,10 213T, 215T 1.375 11.5 10 5F20-847 15 254T 1.625 17.5 10 5F30-847 7-1/2,10 213T, 215T 1.375 17.5 15 5F40-603 5F40,60 15 254T 1.625 17.5 15 5F40-623 20 256T 1.625 30.0 21 5F60-623 25,30 284T, 286T 1.875 34.5 21 5F60-613 20 256T 1.625 34.5 21 5H40-613 25,30 284T, 286T 1.875 65 24 5H60-613 5H40,46 40,50,60 324TS, 326TS, 364TS 1.875 65 24 5H60-613 40,50 324T, 326T 2.125 65 24 5H60-623 60 364T 2.375 86 30 5H80-613 30 286T 1.875 65 24 5H60-613 40,50,60 324TS, 326TS, 364TS 1.875 65 24 5H60-613 5H60,66 40,50 324T, 326T 2.125 65 24 5H60-623 60,75 364T, 365T 2.375 86 30 5H80-613 75 365TS 1.875 86 30 5H80-663 100 404TS 2.125 150 35 5H120-623 40,50,60 324TS, 326TS, 364TS 1.875 65 24 5H60-613 40,50 324T, 326T 2.125 65 24 5H60-623 5H80,86 60,75 364T, 365T 2.375 86 30 5H80-613 75 365TS 1.875 86 30 5H80-663 100 404TS, 405TS 2.125 150 35 5H120-623 60 364TS 1.875 65 24 5H60-613 60,75 364T, 365T 2.375 86 30 5H80-613 5H120,126 75 365TS 1.875 86 30 5H80-663 100,125 404TS, 405TS 2.125 150 35 5H120-623 100,125 404T, 405T 2.875 200 40 5H126-623 * 150,200 444TS, 445TS 2.375 200 40 5H126-623 * *When 5H126-623 coupling is used with a 404T or 405T frame motor, field boring is required. Enlarge motor bore to 2.875/2.8755 in. diameter. Increase Keyway size to 3/4 x 3/8 in. MOTOR FASTENING KITS FOR DIRECT DRIVE APPLICATIONS P99 Motor Fastening Kit includes steel blocks and shims to align motor shaft to compressor shaft, hardware to attach motor to base and tapered dowel pins to pin motor to base and lock in alignment.not enough memory to convert the items on the clipboard. MOTOR MOTOR MOTOR FRAME SHAFT SHAFT HT. (in.) HP SIZE HT. (in.) 5F40-401/ 7-1/2,10 213T, 215T 5-1/4 5F20,30 6-1/4 5F40-801 15 254T 6-1/4 5F40-801 7-1/2,10 213T, 215T 5-1/4 5F40-801 5F40,60 8 15,20 254T, 256T 6-1/4 5F40-401 25,30 284T, 286T 7 5F40-401 20 256T 6-1/4 5F40-801 5H40,46 9 25,30 284T, 286T 7 5H40-401 40,50 324, 326 T/Ts 8 5F40-401 60,75 364, 365 T/TS 9 5F60-401 30 286T 7 5H40-401 5H60,66 9 40,50 324, 326 T/TS 8 5F40-401 60,75 364, 365 T/TS 9 5F60-401 100 404 T/TS 10 5F60-401 40,50 324, 326 T/TS 8 5F40-401 5H80,86 9 60,75 364, 365 T/TS 9 5F60-401 100,125 404, 405 T/TS 10 5F60-401 60,75 364, 365 T/TS 9 5H40-401 5H120,126 11 100,125 404, 405 T/TS 10 5F40-401 150,200 444, 445 TS 11 5F60-401 NOTE: Motor Fastening kit approximate shipping weight is 42 lbs. 91

CARLYLE OPEN DRIVE S/ACCESSORIES MOTOR FASTENING KIT FOR BELT DRIVE APPLICATIONS Motor Fastening Kit attaches motor to base. Kit includes: bolts, nuts and washers. MOTOR SIZE MOTOR FRAME SIZE 5F20,30 5, 7-1/2, 10 184T, 213T, 215T 5F20-821 5F30 15 254T 5F30-821 5F40,60 7-1/2, 10 213T, 215T 15, 20, 25 254T, 256T, 284T 5F20-821 5H40 20, 25, 30 256T, 284T, 286T 40,50 324T, 326T 5F30-821 5H60 40,50 324T, 326T 5F30-821 5H60 40,50 324T, 326T 60,75 364T, 365T 5H40-711 P100 MOTOR SIZE MOTOR FRAME SIZE 5H80, 120 40,50,60,75 324T, 326T, 364T, 365T 5H40-711 100,125,150 404T, 405T, 444T Compressor Mounting Block is used when a 5H66,80,86 is matched to a 100 Hp motor, or when a 5H86 is matched to a 125 Hp motor. The block raises compressor to allow alignment between compressor and motor shaft. Two blocks are required per compressor. : 5H40-1422 92

CARLYLE OPEN DRIVE S/ACCESSORIES CONTROL PANELS Control panels are designed for indoor use to control compressor and condensing units from 5 thru 150 Hp, in 208 to 575 volts, across-the-line starting applications. All units operate on 120 volt control circuit. FEATURES: ETL APPROVED OIL PRESSURE SAFETY SWITCH protects compressor against damage from low oil pressure. TIME GUARD circuit protects compressor and motor against short cycling. OVERLOAD RELAY* manual reset. SUCTION, DISCHARGE, OIL PRESSURE GAUGES display operating conditions. P101 GAUGE SHUTOFF VALVES CAPILLARIES supplied for pressure gauges and switches. Control panel easily mounts on one end of the unit base. Simple conversion to part-winding starting on 2 contactor models TERMINAL BLOCKS for field connections. CONTACTORS by adding time delay HN67ZA001. Single contactor panels require the addition of another contactor of the same size GROUNDING LUG and time delay HN67ZA001. * Single overload panels: overload dial is set at a value equal to NEC motor full load current rating and will trip at 125% of this rating. If tripping is required at 115% of NEC motor full load current rating, set the overload dial to value 0.92 times F.L.C. value. Two overload panels: Each overload dial is set at a value equal to one half of NEC motor full load current rating and will trip at 125% of the setpoint. If tripping is required at 115% of NEC motor full load current rating, set each overload dial to value of 0.92 times one half of F.L.C. value. CRANKCASE HEATER RELAY energizes heater on compressor shutdown to prevent dilution of oil by refrigerant. PUMPOUT RELAY safeguards compressor against liquid refrigerant slugging on start-up. ELAPSED RUNNING TIME METER WIRE ASSEMBLIES provided in conduit are used to connect panel box and external controls to a junction box (provided). FUSE, ON-OFF SWITCH, NEMA ENCLOSURE HINGED COVER HEAVY DUTY PANEL MOUNTING BASE is provided. Can be welded to compressor base or attached with supplied hardware. 93

CARLYLE OPEN DRIVE S/ACCESSORIES CONTROL PANELS MOTOR CONTACTOR OVERLOAD LUG WIRE APPROX. CONTROL HP NEC Amps RANGE SHIP. WT PANEL Volts Rating Qty Amp Qty (FLA)* (AC3) Range (AWG) (lbs) 5 17.5 208 28 1 13-19 1 12-8 115 32CF131A4 5 15.2 230 17 1 13-19 1 18-10 115 32CF131A5 5 7.6 460 9 1 6-8.5 1 18-10 115 32CF131A6 5 6.1 575 9 1 4.5-6.5 1 18-10 115 32CF131A1 7.5 25 208 28 1 24-32 1 12-8 115 32CF132B4 7.5 22 230 28 1 18-25 1 12-8 115 32CF132B5 7.5 11 460 11 1 10-14 1 18-10 115 32CF131B6 7.5 9 575 9 1 7.5-11 1 18-10 115 32CF131B1 10 32 208 32 1 29-42 1 8-4 115 32CF142C4 10 28 230 32 1 24-32 1 8-4 115 32CF142C5 10 14 460 17 1 13-19 1 18-10 115 32CF131C6 10 11 575 11 1 10-14 1 18-10 115 32CF131C1 15 48 208 54 1 36-52 1 8-1 115 32CF153D4 15 42 230 41 1 36-52 1 8-1 115 32CF153D5 15 21 460 28 1 18-25 1 12-8 115 32CF132D6 15 17 575 17 1 13-19 1 18-10 115 32CF131D1 20 62 208 65 1 45-63 1 8-1 115 32CF242E4 20 54 230 54 1 45-63 1 8-1 115 32CF242E5 20 27 460 32 1 24-32 1 8-4 115 32CF142E6 20 22 575 28 1 18-25 1 12-8 115 32CF142E1 25 78 208 80 1 60-80 1 8-1 130 32CF243F4 25 68 230 80 1 60-80 1 8-1 130 32CF242F5 25 34 460 41 1 29-42 1 8-4 115 32CF152F6 25 27 575 28 1 24-32 1 12-8 115 32CF152F1 30 92 208 95 1 80-110 1 6-2/0 130 32CF253G4 30 80 230 80 1 60-80 1 8-1 130 32CF243G5 30 40 460 41 1 29-42 1 8-4 115 32CF231G6 30 32 575 32 1 29-42 1 8-4 115 32CF141G1 40 120 208 130 1 100-135 1 8-3/0 130 32CF263H4 40 104 230 110 1 80-110 1 6-2/0 130 32CF263H5 40 52 460 54 1 45-63 1 8-1 115 32CF242H6 40 41 575 41 1 29-42 1 8-4 115 32CF241H1 50 150 208 156 1 130-175 1 8-250MCM 130 32CG273J4 50 130 230 130 1 100-135 1 8-3/0 130 32CG273J5 50 65 460 65 1 60-80 1 8-1 130 32CF242J6 50 52 575 54 1 45-63 1 8-1 115 32CF242J1 60 177 208 192 1 150-200 1 6-250MCM 130 32CH295K4 60 154 230 156 1 130-175 1 8-250MCM 130 32CH295K5 60 77 460 80 1 60-80 1 8-1 130 32CF253K6 60 62 575 65 1 60-80 1 8-1 130 32CF252K1 75 221 208 242 1 220-310 1 4-500MCM 130 32CH205L4 75 192 230 192 1 150-200 1 6-250MCM 130 32CH205L5 75 96 460 11 1 80-110 1 6-2/0 130 32CF263L6 75 77 575 95 1 80-110 1 6-2/0 130 32CF263L1 100 285 208 156 2 110-150 2 6-350MCM 130 32CI216M4 100 248 230 130 2 100-135 2 6-350MCM 130 32CI216M5 100 124 460 130 1 100-135 1 8-3/0 130 32CH274M6 100 99 575 110 1 80-110 1 6-2/0 130 32CF273M1 125 358 208 192 2 150-200 2 6-350MCM 130 32CI227N4 125 312 230 156 2 130-175 2 6-350MCM 130 32CI227N5 125 156 460 156 1 130-175 1 8-250MCM 130 32CI205N6 125 125 575 130 1 100-135 1 8-3/0 130 32CI225N1 150 415 208 242 2 165-235 2 2-600MCM 130 32CJ217P4 150 360 230 192 2 150-200 2 6-350MCM 130 32CJ227P5 150 180 460 192 1 150-200 1 6-250MCM 130 32CJ205P6 150 144 575 156 1 110-150 1 8-250MCM 130 32CJ284P1 200 550 208 302 2 220-310 2 2-600MCM 130 32CJ218Q4 200 480 230 242 2 220-310 2 2-600MCM 130 32CJ218Q5 200 240 460 242 1 220-310 1 4-500MCM 130 32CJ216Q6 200 192 575 192 1 150-200 1 6-250MCM 130 32CJ205Q1 *From the National Electrical Code based on motor horsepower and voltage. AC3 rating is an IEC (International Electrical Code) rating per U.L. standards. The contactors supplied with the panels are not definite purpose contactors. They are specific to motor switching circuits. NOTE: The information presented in the table above is for the current control panels offered through RCD. 94

CARLYLE OPEN DRIVE S/ACCESSORIES TO DRIVE MOTOR COMBINATIONS Motor selection is based on compressor rating charts. 5F /MOTOR COMBINATIONS MOTOR H.P. RATING 5F20 5,7.5,10 5F30 7.5,10,15 5F40 7.5,10,15,20,25 5F60 10,15,20,25,30 NOTE: Extended stroke compressors (5H46,66,86,126) should not be applied on belt drive applications. 5H /MOTOR COMBINATIONS MOTOR H.P RATING 5H40 20,25,30,40,50 5H46* 25,30,35,40,50,60 5H60 30,40,50,60,75 5H66* 40,50,60,75,100 5H80 40,50,60,75,100 5H86* 50,60,75,100,125 5H120* 60,75,100,125,150 5H126* 75,100,125,150,200 MOTORS DRIP-PROOF P183 3 Phase, 60 Hertz 40 C Ambient Nema Design B 1.15 Service Factor Class B Insulation Continuous Duty F1 Assembly TOTALLY ENCLOSED, FAN COOLED 3 Phase, 60 Hertz 40 C Ambient Nema Design B 1.15 Service Factor Class B Insulation Continuous Duty F1 Assembly H.P. SPEED VOLTAGE(1) FRAME 5 1800 200-208 184T 240-139 1800 208-230/460 184T 240-138 7.5 1800 200-208 213T 240-147 1800 208-230/460 213T 240-146 10 1800 200-208 215T 240-155 1800 208-230/460 215T 240-154 15 1800 200 254T 240-163 1800 208/230/460 254T 240-162 20 1800 200-208 256T 240-171 1800 230/460 256T 240-170 25 1800 208/230/460 284T 240-179 1800 230/460 284T 240-178 30 1800 200-208 286T 240-189 1800 2081230/460 286T 240-188 40 1800 200-208 324T 240-197 1800 230/460 324T 240-196 50 1800 200-208 326T 240-205 1800 230/460 326T 240-204 60 1800 200-208 364T 240-213 1800 230/460 364T 240-212 75 1800 200-208 365T 240-221 1800 230/460 365T 240-220 100 1800 200-208 404T 240-231 1800 230/460 404T 240-230 125 1800 460 405T 240-240 150 1800 460 444TS See Note 200 1800 460 445TS See Note (1) Motors rated 208-230/460 will operate at 208 volts. At 208 volts, motor may not meet NEMA specifications. NOTE: Order these by description. P184 H.P. SPEED VOLTAGE* FRAME 5 1800 200-208 184T 241-139 1800 230/460 184T 241-138 10 1800 200-208 215T 241-155 1800 230/460 215T 241-454 15 1800 200-208 254T 241-463 1800 230/460 254T 241-462 20 1800 200-208 256T 241-471 1800 230/460 256T 241-170 25 1800 200-208 284T 241-479 1800 230/460 284T 241-478 30 1800 200-208 286T 241-489 1800 230/460 286T 241-488 40 1800 200-208 324T 241-497 1800 230/460 324T 241-496 50 1800 200-208 326T 241-205 1800 230/460 326T 241-204 60 1800 200-208 364T 241-213 1800 230/460 364T 241-212 75 1800 200-208 365T 241-221 1800 230/460 365T 241-220 100 1800 200-208 405T 241-231 1800 230/460 405T 241-230 125 1800 460 444TS See Note 150 1800 460 445TS See Note 200 1800 460 445T 241-258 *230 volt motors operational on 208 volt network. NOTE: Order these by description. 95

CARLYLE OPEN DRIVE S/ACCESSORIES DIRECT DRIVE UNIT BASES Heavy duty channeled steel base Coupling guard included Motor and compressor mounting holes are predrilled. Select motor drilling code from the chart below: B110-1 MOTOR DRILLING CODE CHART CODE H. P. FRAME CODE H.P. FRAME CODE H. P. FRAME A 5 184T F 25 284T L 75 365T B 7.5 213T G 30 286T M 100 404T C 10 215T H 40 324T N 125 405T D 15 254T J 50 326T O 150 444TS E 20 256T K 60 364T P 200 445TS USED WITH MOTOR DRILLING SELECTION BASE SIZE (L x W x H) APPROX. BASE WEIGHT (lbs) 5F20 A,B,C 37 x 16 x 11 200 5F30 B,C,D 37 x 16 x 11 200 5F40 B,C,D,E,F 48 x 22 x 6 250 5F60 C,D,E,F,G 48 x 22 x 6 250 5H40 E,F,G,H,J 56 x 25 x 8 400 5H46 F,G,H,J,K 56 x 25 x 8 400 5H60 G,H,J,K,L 56 x 25 x 8 400 5H66 H,J,K,L,M 56 x 25 x 8 400 5H80 H,J,K,L,M 75 x 32 x 10 800 5H86 J,K,Mt,Nt 75 x 32 x 10 800 5H120 K,L,M,N,O 75 x 32 x 10 800 5H126 L,M,N,O,P 75 x 32 x 10 800 DIRECT DRIVE UNIT BASE 5F20-515(*) 5F40-398(*) 5H40-588(*) 5H80-588(*) (*)Select motor drilling from chart above to complete part number. For example, when 5F20-515A is selected the base will be drilled to accept a 5 H.P., 184T frame motor. 5H66, 80, 86 with 100 H.P. motor and 5H86 with 125 H.P. motor require (2) 5H40-1422 compressor blocks. NOTE: For base drilling code selections H thru N, an S placed at the end of the part number indicates a base drilling for a short shaft motor/ts frame. (For example, 5H40-588HS is a 5H40-588 base drilled to accept a 324TS frame motor.) 96

CARLYLE OPEN DRIVE S/ACCESSORIES BELT DRIVE UNIT BASES Heavy duty channeled steel base Belt guard included. Compressor mounting holes are predrilled. An adjustable steel motor base facilitates motor positioning. Select adjustable motor base from the chart below: B111-1 ADJUSTABLE MOTOR BASE CODE CHART CODE H. P. FRAME CODE H. P. FRAME CODE H.P. FRAME A 5 184T F 25 284T L 75 365T B 7.5 213T G 30 286T M 100 404T C 10 215T H 40 324T N 125 405T D 15 254T J 50 326T E 20 256T K 60 364T USED WITH ADJUSTABLE MOTOR APPROX. BASE WEIGHT BASE SIZE (L x W x H) BASE (lbs) 5F20 A, B,C 37 x 16 x 11 150 5F30 B,C, D 37 x 16 x 11 150 5F40 B,C,D,E,F 48 x 22 x 6 250 5F60 C,D,E,F,G 48 x 22 x 6 250 5H40 E,F,G,H,J 56 x 25 x 8 440 5H60 G,H,J,K,L 56 x 25 x 8 440 5H80 H,J,K,L,M 75 x 32 x 10 625 5H120 K,L,M,N 75 x 32 x 10 625 (*)Select adjustable base code from chart above to complete part number. For example, when 5F20-238A is selected the adjustable motor base will accept a 5 H.P., 184T frame motor. BELT DRIVE UNIT BASE 5F20-238(*) 5F40-408(*) 5H40-598(*) 5H60-974(*) 97

CARLYLE OPEN DRIVE S/ACCESSORIES FLYWHEEL, PULLEY, BELTS P95 P96 P97 COM- PRESSOR MOTOR H. P. PD - Pitch Diameter (in.) PL - Pitch Length (in.) MOTOR FRAME SIZE MOTOR SHAFT DIA. (in.) COM- PRESSOR RPM CENTER TO CENTER (in.) FLYWHEEL PULLEY BELTS PD NO. OF GROOVES & TYPE PD NO. OF GROOVES & TYPE 5F20 5 184T 1-1/8 1750 19.3 5F20-394 7.5 2-B 5F20-861 7.4 2-B 5F20-851 61.8 2-B 5F20 7.5 213T 1-3/8 1750 19.3 5F20-394 7.5 2-B 5F20-891 7.4 2-B 5F20-851 61.8 2-B 5F20 10 215T 1-3/8 1750 19.3 5F20-394 7.5 2-B 5F20-891 7.4 2-B 5F20-851 61.8 2-B 5F30 7.5 213T 1-1/8 1750 19.3 5F20-394 7.5 2-B 5F20-891 7.4 2-B 5F20-851 61.8 2-B 5F30 10 215T 1-3/8 1750 19.3 5F20-394 7.5 2-B 5F20-891 7.4 2-B 5F20-851 61.8 2-B 5F30 15 254T 1-5/8 1750 19.3 5F30-394 7.5 3-B 5F30-921 7.4 3-B 5F30-831 61.8 3-B 5F40 7.5 213T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F30-881 9.4 3-B 5F40-841 82.8 3-B 5F40 10 215T 1-3/8 1750 26.6 5F40-394 9.5 3-B 5F30-881 9.4 3-B 5F40-841 82.8 3-B 5F40 15 254T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F40-871 9.4 3-B 5F40-841 82.8 3-B 5F40 20 256T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F40-871 9.4 3-B 5F40-841 82.8 3-B 5F40 25 284T 1-7/8 1750 26.6 5F40-394 9.5 3-B 5F40-881 9.4 3-B 5F40-841 82.8 3-B 5F60 10 215T 1-3/8 1750 26.6 5F40-394 9.5 3-B 5F30-881 9.4 3-B 5F40-841 82.8 3-B 5F60 15 254T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F40-871 9.4 3-B 5F40-841 82.8 3-B 5F60 20 256T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F40-871 9.4 3-B 5F40-841 82.8 3-B 5F60 25 284T 1-7/8 1750 26.6 5F40-394 9.5 3-B 5F40-881 9.4 3-B 5F40-841 82.8 3-B 5F60 30 286T 1-7/8 1750 26.6 5F40-394 9.5 3-B 5F40-881 9.4 3-B 5F40-841 82.8 3-B 5H40 20 256T 1-5/8 1750 32.2 5H40-394 11.0 3-C 5H40-811 11.0 3-C 5H40-861 92.9 3-C 5H40 25 284T 1-7/8 1750 32.2 5H40-394 11.0 3-C 5H80-811 11.0 3-C 5H40-861 98.9 3-C 5H40 30 286T 1-7/8 1750 32.2 5H40-394 11.0 3-C 5H80-811 11.0 3-C 5H40-861 98.9 3-C 5H40 40 324T 2-1/8 1750 32.2 5H40-394 11.0 3-C 5H40-821 11.0 3-C 5H40-861 98.9 3-C 5H40 50 326T 2-1/8 1750 32.2 5H40-394 11.0 3-C 5H40-821 11.0 3-C 5H40-861 98.9 3-C 5H60 30 286T 1-7/8 1750 32.2 5H40-394 11.0 3-C 5H80-811 11.0 3-C 5H40-861 98.9 3-C 5H60 40 324T 2-1/8 1750 32.2 5H40-394 11.0 3-C 5H40-821 11.0 3-C 5H40-861 98.9 3-C 5H60 50 326T 2-1/8 1750 32.2 5H60-394 11.0 5-C 5H80-821 11.0 5-C 5H120-861 98.9 5-C 5H60 60 364T 2-3/8 1750 32.2 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H120-861 98.9 5-C 5H60 75 365T 2-3/8 1750 32.2 5H40-394 11.0 5-C 5H120-821 11.0 5-C 5H120-861 98.9 5-C 5H80 40 324T 2-1/8 1750 36.7 5H60-394 11.0 5-C 5H80-821 11.0 5-C 5H40-871 107.9 5-C 5H80 50 326T 2-1/8 1750 36.7 5H60-394 11.0 5-C 5H80-821 11.0 5-C 5H40-871 107.9 5-C 5H80 60 364T 2-3/8 1750 36.7 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H40-871 107.9 5-C 5H80 75 365T 2-3/8 1750 36.7 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H40-871 107.9 5-C 5H80 100 404T 2-7/8 1750 36.7 5H120-394 11.0 9-C 5H120-831 11.0 9-C 5H120-871 107.9 9-C 5H120 60 364T 2-3/8 1750 36.7 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H40-871 107.9 5-C 5H120 75 365T 2-3/8 1750 36.7 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H40-871 107.9 5-C 5H120 100 404T 2-7/8 1750 36.7 5H120-394 11.0 9-C 5H120-831 11.0 9-C 5H120-871 107.9 9-C 5H120 125 405T 2-7/8 1750 36.7 5H120-394 11.0 9-C 5H120-831 11.0 9-C 5H120-871 107.9 9-C PL NO. OF BELTS 98

CARLYLE OPEN DRIVE S/ACCESSORIES DIMENSIONAL AND PHYSICAL DATA FOR UNITS 06LH MOTOR- UNIT 6G 009 109 209 014 114 214 018 118 218 028 128 228 40 45 60 63 65 6L40 6L43 6L45 6L60 6L63 6L65 6L80 6L83 6L85 6L120 6L123 6L125 A 31-7/8 31-7/8 33-1/8 33-1/8 33-1/8 39-1/2 39-1/2 39-1/2 41-1/2 41-1/2 41-1/2 56-7/8 56-7/8 56-7/8 60 60 60 B 21-1/8 21-1/8 23 23 23 28-5/8 28-5/8 28-5/8 29-1/8 29-1/8 28-3/8 28-3/8 28-3/8 28-3/8 29-1/4 29-1/4 29-1/4 C 18-5/8 18-5/8 19-3/4 19-3/4 19-3/4 25-7/8 25-7/8 25-7/8 28-7/8 28-7/8 28-7/8 29-1/2 29-1/2 29-1/2 33-3/8 33-3/8 33-3/8 DIMENSIONS* D 19-1/8 19-1/8 19-1/8 19-1/8 19-1/8 25-3/8 25-3/8 25-3/8 25-3/8 25-3/8 25-3/8 35-7/8 35-7/8 35-7/8 35-7/8 35-7/8 35-7/8 E 11 11 11 11 11 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 F 21-7/8 21-7/8 21-7/8 21-7/8 21-7/8 26-3/8 26-3/8 26-3/8 26-3/8 26-3/8 26-3/8 37-1/2 37-1/2 37-1/2 37-1/2 37-1/2 37-1/2 G 18-1/4 18-1/4 18-1/4 18-1/4 18-1/4 27 27 27 27 27 27 32-1/2 32-1/2 32-1/2 32-1/2 32-1/2 32-1/2 MOUNTING HOLES (Dia.) H 9/16 9/16 5/16 9/16 9/16 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 MOUNTING RAIL HOLES (Dia.) J 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 SUCTION VALVE (ODF) K 1-5/8 1-5/8 2-1/8 2-1/8 2-1/8 2-1/8 2-5/8 2-5/8 3-1/8 3-1/8 3-1/8 4-1/8 4-1/8 4-1/8 4-1/8 4-1/8 4-1/8 DISCHARGE VALVE (ODF) L 1-1/8 1-1/8 1-3/8 1-3/8 1-3/8 1-5/8 1-5/8 1-5/8 2-1/8 2-1/8 2-1/8 3-1/8 3-1/8 3-1/8 3-1/8 3-1/8 3-1/8 NET WEIGHT (lbs) 480 546 690 730 760 1040 1080 1145 1310 1410 1500 1830 1870 1890 2150 2190 2220 RATINGS AT 40F SATURATED SUCTION TEMP. AND 105F CONDENSING TEMP. (Tons)** ASRE RATINGS (Tons) at 1750 RPM REFRIGERANT 12 10.8 10.8 16.2 16.2 25.6 25.6 38.4 38.4 51.2 51.2 76.8 76.8 CARRENE 500 12.7 12.7 19.0 30.2 30.2 45.3 45.3 60.4 60.4 90.6 90.6 REFRIGERANT 22 17.1 25.6 39.8 59.6 59.6 79.5 119.4 NUMBER Of CYLINDERS 4 4 6 6 6 4 4 4 6 6 6 8 8 8 12 12 12 BORE, INCHES 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 STROKE, INCHES 2 2 2 2 2 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 DISPLACEMENT, CFM AT 1750 RPM 39.8 39.8 59.6 59.6 59.6 92.4 92.4 92.4 138.4 138.4 138.4 184.8 184.8 184.8 276.8 276.8 276.8 GROUP III (20 and 105)** GROUP VII (20 and 100)** GROUP IV (40 and 110)** GROUP VIII (40 and 100)** REFRIGERANT 12 6.7 6.7 10.0 10.0 15.8 15.8 23.8 23.8 31.6 31.6 47.5 47.5 CARRENE 500 7.8 7.8 11.6 18.3 18.3 27.6 27.6 36.8 36.8 55.1 55.1 REFRIGERANT 22 10.6 16.0 16.0 25.4 25.4 38.1 38.1 50.8 76.4 REFRIGERANT 12 10.1 10.1 15.2 15.2 24.0 24.0 35.8 35.8 48.0 48.0 71.8 71.8 CARRENE 500 11.9 18.8 28.2 42.3 42.3 56.3 56.3 84.6 REFRIGERANT 22 17.2 25.7 25.7 40.3 40.3 60.3 60.3 80.5 120.4 SPEED, RPM (60 Cycle) 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 MINIMUM NET OIL PRESSURE FOR UNLOADER OPERATION (PSI) 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 RECOMMENDED NET OIL PRESSURE AT 1750 RPM (PSI) 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 NORMAL OIL LEVEL IN SIGHT-GLASS CENTER LINE FACTORY OIL CHARGE (Pints) 18 18 20 20 20 30 30 30 47 47 47 80 80 80 90 90 90 *All dimensions are in inches. Dimensions shown are approximate. Certified dimension prints are available on request. **These are saturation temperatures corresponding to the actual suction and discharge pressures at the compressor. Refrigerants 12, C-500 and 22 are suitable for use in any of the units as long as motor kw limitations are not exceeded. These rating points are in accordance with ASRE Standard 23-R, Methods of Rating and Testing Motor Compressor Units. For 1450 rpm, reduce capacity, and power input to 83% of 1750 rpm valves. Net Oil Pressure = Oil Pressure Gauge Reading Suction Pressure. 99

CARLYLE OPEN DRIVE S 6L, 06L REPLACEMENT AND MOTOR GROUP FORMER 6L SIZE CURRENT 06L SIZE 6L40 06LA009 06LH009 6L43 06LA109 06LH109 6L45 06LA209 06LH209 6L60 06LA014 06LH014 6L63 06LA114 06LH114 6L65 06LA214 06LH214 6L80 06LA018 06LH018 6L83 06LA118 06LH118 6L85 06LA218 06LH218 6L120 06LA028 06LH028 6L123 06LA128 06LH128 REPLACEMENT 6L123* 06LA123 06LH123 6L125 06LA228 06LH228 *10 Cylinder Compressor. 100

06L PERFORMANCE DATA CAPACITIES (60 Hz) CARLYLE OPEN DRIVE S SST 10 20 30 40 44 R-500 R-22 SDT 06LH214 06LH218 6LH228 06LH214 06LH218 06LH228 Cap. Kw THR Cap. kw THR Cap. kw THR Cap. kw THR Cap. kw THR Cap. kw THR 90 25.0 27.2 32.8 33.8 36.4 44.1 49.9 53.9 65.3 35.2 36.2 45.5 45.8 47.0 59.2 65.8 73.4 86.7 100 22.8 28.3 30.8 30.5 38.0 41.3 45.3 56.4 61.3 32.4 38.1 43.2 42.0 50.0 56.2 60.8 76.8 82.7 105 21.6 28.8 29.9 28.9 38.6 39.9 43.1 57.3 59.4 31.0 38.8 42.0 - - - 58.4 78.4 80.7 110 20.6 29.2 28.9 - - - 40.9 58.1 57.4 29.5 39.3 40.8 - - - 56.0 79.9 78.8 120 18.4 29.8 26.9 - - - 36.6 58.9 53.4 - - - - - - - - - 130 16.3 29.9 24.9 - - - 32.4 58.7 49.2 - - - - - - - - - 90 32.5 30.3 41.1 43.5 40.4 55.0 64.8 60.0 81.9 45.1 38.8 56.1 58.4 49.6 72.5 85.9 78.5 108.2 100 29.9 32.1 39.0 39.9 42.8 52.0 59.6 63.7 77.7 41.9 41.6 53.7 54.1 53.9 69.5 80.0 83.6 103.8 105 28.6 32.8 37.9 38.1 43.8 50.5 57.0 65.2 75.6 40.2 42.8 52.4 51.9 56.1 67.9 77.0 86.1 101.5 110 27.3 33.5 36.9 36.3 44.7 49.0 54.4 66.6 73.4 38.6 43.8 51.1 49.7 58.1 66.2 74.1 88.5 99.3 120 24.7 34.7 34.6 32.7 46.3 45.8 49.3 68.8 68.9 35.3 45.6 48.3 - - - 67.8 92.7 94.2 130 22.1 35.4 32.2 - - - 44.1 70.1 64.1 32.2 46.8 45.5 - - - 60.7 95.6 88.0 140 19.5 35.8 29.7 - - - 38.8 70.5 58.9 - - - - - - - - - 90 40.9 33.0 50.3 54.6 43.8 67.0 81.7 65.1 100.2 56.3 40.7 67.9 72.9 50.9 87.4 108.8 81.5 132.0 100 38.0 35.3 48.1 50.6 46.9 64.0 75.9 69.9 95.8 52.6 44.3 65.2 68.1 56.6 84.3 101.9 88.5 127.1 105 36.6 36.4 46.9 48.6 48.4 62.4 73.0 72.1 93.5 50.7 46.0 63.8 65.7 59.5 82.6 98.4 92.0 124.6 110 35.1 37.4 45.7 46.6 49.7 60.7 70.0 74.2 91.2 48.9 47.6 62.4 63.1 62.4 80.8 94.8 95.4 121.9 120 32.1 39.2 43.2 42.5 52.3 57.4 64.1 77.8 86.3 45.1 50.4 59.4 57.7 67.8 77.0 87.0 101.6 116.0 130 29.0 40.6 40.5 38.3 54.5 53.8 58.0 80.7 81.0 41.3 53.0 56.4 52.1 72.4 72.7 78.4 106.8 108.8 135 27.4 41.1 39.0 36.1 55.4 51.9 54.8 77.9 81.9 39.5 54.1 54.9 49.1 74.2 70.3 73.6 108.7 104.5 140 25.8 41.6 37.6 33.9 56.4 50.0 51.6 75.1 82.8 - - - - - - - - - 90 50.2 34.9 60.2 67.0 46.3 80.2 100.4 68.8 120.0 68.9 41.7 80.8 89.5 50.9 104.0 134.4 82.3 157.8 100 47.1 37.9 57.9 62.7 50.2 77.0 94.1 74.9 115.4 64.7 46.2 77.8 84.1 57.9 100.6 126.3 91.2 152.3 105 45.5 39.3 56.6 60.5 52.1 75.4 90.9 77.8 113.0 62.5 48.3 76.3 81.3 61.6 98.8 122.2 95.8 149.4 110 43.8 40.6 55.4 58.3 54.0 73.6 87.6 80.6 110.5 60.3 50.4 74.7 78.3 65.3 96.9 117.8 100.2 146.4 120 40.4 43.1 52.7 53.7 57.5 70.1 80.9 85.7 105.3 56.0 54.4 71.4 72.2 72.6 92.9 108.6 108.7 139.5 130 36.8 45.2 49.7 48.9 60.8 66.2 73.9 90.2 99.6 51.6 58.1 68.1 65.7 79.3 88.3 98.2 116.2 131.3 135 34.9 46.1 48.0 46.5 62.3 64.1 70.2 92.1 96.4 49.4 59.9 66.4 62.3 82.3 85.8 92.5 119.4 126.5 140 33.1 46.9 46.4 43.9 63.9 62.1 66.5 94.0 93.2 - - - - - - - - - 90 54.2 35.4 64.3 72.3 47.0 85.7 108.3 69.8 128.2 74.3 41.8 86.2 96.7 50.5 111.1 145.3 81.9 168.6 100 51.0 38.7 62.0 67.9 51.3 82.5 101.8 76.5 123.6 69.8 46.6 83.1 91.0 58.1 107.6 136.7 91.7 162.8 105 49.3 40.2 60.7 65.6 53.4 80.8 98.5 79.7 121.2 67.6 49.0 81.5 88.1 62.1 105.7 132.3 96.6 159.8 110 47.6 41.7 59.4 63.3 55.4 79.1 95.1 82.7 118.7 65.3 51.2 79.9 85.0 66.1 103.8 127.7 101.5 156.6 120 44.0 44.4 56.6 58.6 59.3 75.5 88.1 88.5 113.3 60.6 55.6 76.5 78.5 74.2 99.7 117.8 111.0 149.4 130 40.2 46.8 53.6 53.6 63.0 71.5 80.8 93.7 107.4 56.0 59.9 73.0 71.7 81.7 94.9 106.7 119.4 140.7 135 38.2 47.0 51.9 40.8 64.8 69.9 76.9 95.9 104.1 53.6 61.9 71.3 68.1 85.2 92.3 100.6 123.1 135.6 140 36.3 48.8 50.2 48.3 66.6 67.3 73.0 98.2 100.9 - - - - - - - - - 101

06L PERFORMANCE DATA CAPACITIES (60 Hz) CARLYLE OPEN DRIVE S SST 48 50 R-500 R-22 SDT 06LH214 06LH218 6LH228 06LH214 06LH218 06LH228 Cap. kw THR Cap. kw THR Cap. kw THR Cap. kw THR Cap. kw THR Cap. kw THR 90 58.3 35.8 68.5 77.9 47.6 91.4 116.6 70.6 136.7 79.9 41.8 91.8 104.3 49.8 118.5 156.5 81.1 179.6 100 55.0 39.3 66.2 73.3 52.2 88.2 109.9 77.8 132.0 75.2 46.9 88.6 98.3 58.0 114.8 147.5 91.7 173.6 105 53.2 41.0 64.9 71.0 54.4 86.5 106.4 81.3 129.6 72.8 49.4 86.9 95.2 62.3 112.9 142.8 97.1 170.4 110 51.4 42.6 63.6 68.6 56.7 84.8 102.9 84.7 127.0 70.4 51.9 85.2 91.9 66.7 110.9 137.8 102.5 167.0 120 47.7 45.6 60.7 63.7 61.0 81.0 95.6 91.1 121.6 65.5 56.7 81.6 85.1 75.5 106.6 127.3 112.8 159.4 130 43.8 48.3 57.5 58.4 65.1 77.0 87.9 96.9 115.5 60.6 61.4 78.0 77.9 83.9 101.8 115.4 122.3 150.2 135 41.7 49.4 55.7 55.6 67.1 74.8 83.8 99.5 112.1 58.1 63.7 76.2 74.1 87.8 99.1 108.9 126.5 144.9 140 39.6 50.6 54.0 52.9 69.2 72.6 79.7 102.2 108.8 - - - - - - - - - 90 60.4 35.9 70.6 80.7 47.8 94.3 120.8 70.9 140.9 82.8 41.7 94.7 108.2 49.4 122.2 163.3 80.5 185.2 100 57.0 39.6 68.3 76.1 52.6 91.1 114.0 78.4 136.3 78.0 47.0 91.4 102.1 57.9 118.5 153.0 91.5 179.0 105 55.2 41.3 67.0 73.8 54.9 89.4 110.5 82.0 133.9 75.5 49.6 89.6 98.8 62.3 116.6 148.1 97.2 175.8 110 53.4 43.0 65.7 71.3 57.2 87.6 106.9 85.5 131.3 73.0 52.1 87.9 95.5 66.9 114.6 143.0 102.8 172.3 120 49.6 46.2 62.8 66.3 61.7 83.9 99.5 92.3 125.8 68.0 57.2 84.3 88.6 76.1 110.2 132.1 113.6 164.5 130 45.6 49.0 59.6 61.0 66.1 79.8 91.6 98.5 119.7 62.9 62.1 80.6 81.1 84.9 105.3 119.9 123.6 155.1 135 43.4 50.2 57.8 58.1 68.2 77.6 87.4 101.3 116.3 60.4 64.6 78.7 - - - 113.2 128.1 149.6 140 41.3 51.4 56.0 55.3 70.4 75.4 83.3 104.1 112.9 - - - - - - - - - Cap. Capacity kw Power Input SDT Saturated Discharge Temperature SST Saturated Suction Temperature THR Total Heat Rejection (tons) Spaces noted by a dash indicate maximum compressor power is exceeded. NOTES: 1. Capacities are based on 1750 rpm and 15 F subcooling. 2. Liquid subcooling, greater than (less than) the 15 F incorporated in the ratings, increases (decreases) system capacity by 1.2 of 1% for each degree of subcooling. When correcting for subcooling, power input does not change. Adjusted total heat rejection (tons) equals adjusted capacity +.285 x kw input. 3. Refrigerant temperatures shown are saturation temperatures corresponding to pressures indicated at compressor. Actual gas temperatures are higher because of superheat. 4. Capacities are based on actual suction gas temperatures to the compressor of 65 F for R-500. (This assumes superheat is obtained from liquid-suction interchanger or in evaporator.) Capacity corrections, for other than rated suction gas temperatures, may be obtained from Capacity Multipliers table. R-22 suction gas superheat for ratings (15 F) normally occurs because of expansion valve operation and line losses. Therefore R-22 ratings can be used without adjustment. 102

CARLYLE OPEN DRIVE S/ACCESSORIES 06LH OUTLINE DRAWINGS NOTE: S SHOWN WITH OPTIONAL ACCESSORIES - CONTACT YOUR DISTRIBUTOR FOR DETAILS. 06LH109 & 209 S UNIT SIZE NET WEIGHT-LBS 06LH109 1080 06LH209 1145 NOTES: 1. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER DIRECTION OF ROTATION. 2. NET WEIGHT INCLUDES MOTOR, UNIT ASSEMBLY AS SHOWN, LESS REFRIGERANT. 3. MOTOR FURNISHED WITH INTERNAL OVERHEAT PROTECTION. 06LH114, 214 UNIT SIZE NET WEIGHT-LBS 06LH114 1410 06LH214 1500 NOTES: 1. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER DIRECTION OF ROTATION. 2. NET WEIGHT INCLUDES MOTOR, UNIT ASSEMBLY AS SHOWN, LESS REFRIGERANT. 3. SUCTION STRAINER MAY BE REMOVED FROM EITHER HORIZONTAL DIRECTION. TO REMOVE IT FROM THE LEFT (VIEWED FROM PUMP END), REMOVE SUCTION STRAINER COVER. TO REMOVE IT FROM THE RIGHT, REMOVE SUCTION VALVE. SAME CLEARANCE REQUIRED EITHER DIRECTION. OBSERVE SAME CLEARANCE IF MOTOR END COVER IS ROTATED. 4. MOTOR FURNISHED WITH INTERNAL OVERHEAT PROTECTION. 103

CARLYLE OPEN DRIVE S/ACCESSORIES 06LH OUTLINE DRAWINGS NOTE: S SHOWN WITH OPTIONAL ACCESSORIES - CONTACT YOUR DISTRIBUTOR FOR DETAILS. 06LH118, 218 UNIT SIZE NET WEIGHT-LBS 06LH118 1850 06LH218 1890 NOTES: 1. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER DIRECTION OF ROTATION. 2. NET WEIGHT INCLUDES MOTOR, UNIT ASSEMBLY AS SHOWN, LESS REFRIGERANT. 3. SUCTION STRAINER MAY BE REMOVED FROM EITHER HORIZONTAL DIRECTION. TO REMOVE IT FROM THE LEFT (VIEWED FROM PUMP END), REMOVE SUCTION STRAINER COVER. TO REMOVE IT FROM THE RIGHT, REMOVE SUCTION VALVE. SAME CLEARANCE REQUIRED EITHER DIRECTION. OBSERVE SAME CLEARANCE IF MOTOR END COVER IS ROTATED. 4. MOTOR FURNISHED WITH INTERNAL OVERHEAT PROTECTION. 06LH128, 228 UNIT SIZE NET WEIGHT-LBS 06LH128 2190 06LH228 2220 NOTES: 1. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER DIRECTION OF ROTATION. 2. NET WEIGHT INCLUDES MOTOR, UNIT ASSEMBLY AS SHOWN, LESS REFRIGERANT. 3. SUCTION STRAINER MAY BE REMOVED FROM EITHER HORIZONTAL DIRECTION. TO REMOVE IT FROM THE LEFT (VIEWED FROM PUMP END), REMOVE SUCTION STRAINER COVER. TO REMOVE IT FROM THE RIGHT, REMOVE SUCTION VALVE. SAME CLEARANCE REQUIRED EITHER DIRECTION. OBSERVE SAME CLEARANCE IF MOTOR END COVER IS ROTATED. 4. MOTOR FURNISHED WITH INTERNAL OVERHEAT PROTECTION. 104