Background. Whitepaper May Emerson Reliability Consulting. Michael Whittaker, Emerson Process Management

Similar documents
Risk Based Maintenance

Damcos Accumulator Rack Stand Alone System. Product Data Sheet May 2014 SD E03

ABB life cycle services Uninterruptible power supplies

Solid Waste Management

OPTIMISING SEWAGE PUMPING STATION PERFORMANCE

Plenary Session 2. Regulatory aspects and market operations in smart grid environments

Dr. Christopher Ganz, ABB, Group Vice President Extending the Industrial Intranet to the Internet of Things, Services, and People (EU6)

A LIFETIME APPROACH TO ENGINE COSTS IN THE MARINE SECTOR

Risk Management of Rail Vehicle Axle Bearings

Tissue Machine Bearing Failure and PeakVue Problem Resolution

Executive Summary. Solid Waste Management Program Analysis and Recommendations for Silver City, New Mexico

Demystifying HVAC What To Do When They Cut Your Budget By Ron Prager

Prof. Dr. Andrea Giuricin. Benefits of the competition in the High speed rail and the limits to the competition

Transforming the Battery Room with Lean Six Sigma

City of Palo Alto (ID # 6416) City Council Staff Report

Using cloud to develop and deploy advanced fault management strategies

Centerwide System Level Procedure

Hydro Plant Risk Assessment Guide

MEDIA RELEASE. June 16, 2008 For Immediate Release

Emergi-Lite Experts in central power supply systems

Improving predictive maintenance with oil condition monitoring.

Thermal Management: Key-Off & Soak

Technological Viability Evaluation. Results from the SWOT Analysis Diego Salzillo Arriaga, Siemens

AN INTRODUCTION TO THE BENEFITS OF IMPRES ENERGY SOLUTIONS

TRANSIT FEASIBILITY STUDY Town of Bradford West Gwillimbury

Work smarter, not harder. How to make your maintenance program more efficient

Cost Affective Dockside Crane Retrofit Utilizing Existing SCR s

Fire Apparatus Diesel Particulate Filter Reprocessing Henrico County, Virginia Page 1

Draft Marrickville Car Share Policy 2014

APPLICATION GUIDE. ACH580 Managing total cost of ownership of HVAC systems

Retrofitting unlocks potential

No Nonsense Advice on Improving Your Waterborne Spray Application

Merits and demerits of Franchising. Chapter2

London 2050 Infrastructure Plan

Mahindra REVA case study

briefing the Portfolio Committee on Mineral resources

Rural electrification lagging

DeltaV SIS TMAuxiliary Components

CIF # City of Barrie. Large Curbside Containers. Final Report. Final Project Report, September City of Barrie. CIF Project # 801.

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Advice Pertaining to ERC Resolution No.16 and the Role of Hybrid Generation Advice with respect to specific questions from PIPPA

Application Note. Case study Early fault detection of unique pump bearing faults at a major US refinery

ENGINEERING FOR HUMANS STPA ANALYSIS OF AN AUTOMATED PARKING SYSTEM

Pure Solar Technologies

Conoco Phillips Ferndale Condition Monitoring Success

Battery Maintenance Solutions for Critical Facilities

Fluke 438-II Power Quality and Motor Analyzer

B. HOLMQVIST Nuclear Fuel Division, ABB Atom AB, Vasteras, Sweden

PEV Charging Infrastructure: What can we learn from the literature?

Optimizing Battery Accuracy for EVs and HEVs

Regulatory Treatment Of Recoating Costs

TRANSFORMER SERVICE. ABB Ability inspection for transformers TXplore Oil-filled transformer internal inspection service

Meeting papermaking challenges with service

GRID CONSTRAINT: OPTIONS FOR PROJECT DEVELOPMENT

Project Report Cover Page

TANK RISER SUSPENSION SYSTEM CONCEPTUAL DESIGN (U)

Sr Khairul Faizi B M Taib Robert Toba Siahaan

Operational eco-efficiency in Refineries

Submission to Greater Cambridge City Deal

Non-network solutions

Selective Coordination

Abstract. Executive Summary. Emily Rogers Jean Wang ORF 467 Final Report-Middlesex County

IMPLEMENTATION OF THE RCP SHIELD MECHANICAL SEAL MODEL IN THE COMANCHE PEAK PRA

ULTRACAPACITORS FOR UNINTERRUPTIBLE POWER SUPPLY (UPS)

Emergi-Lite EMEX central power supply solutions

GUIDE OF CHANGE MANAGEMENT. Replacement of Fisher POSI-SEAL A81 High-Performance Butterfly Valve with Fisher 8580 High-Performance Butterfly Valve

Belt Conveyors Separating Fact from Fiction Richard Enning Bob Schaefer Steve Timmer

MINISTRY OF EDUCATION AND HUMAN RESOURCES, TERTIARY EDUCATION AND SCIENTIFIC RESEARCH MAURITIUS EXAMINATIONS SYNDICATE NATIONAL ASSESSMENT AT FORM III

POWERFUL LINEUP. Paralleling Generator Sets

Central City Line Locally Preferred Alternative (LPA) Amendment Public Hearing. July 24, 2014

Using ABAQUS in tire development process

RESULTS READER SURVEY TRENDS IN EMPLOYMENT MACHINE TOOL INVESTMENT OUTSOURCING AND OTHER GEAR INDUSTRY BUSINESS PRACTICES

City Power Johannesburg: Response to Potential Load Shedding. Presented by : Stuart Webb General Manager : PCM October 2014

KEYS TO SUCCESSFUL TRANSMISSION NVH TESTING

Stereo-vision for Active Safety

EU-MIDT. Implementation Policy Committee MIDT/IPC/ Best Practise Guide for the Periodic Audit and Enforcement of Tachograph Workshops

100% Renewable Energy for Islands. Case studies Tuvalu & Tokelau

HIGH EFFICIENCY CONTINUOUS CENTRIFUGALS USED IN A MASSECUITE ATAM Congress 2012, Veracruz, MEXICO

FlowScanner 6000 SGIM-1 and SGIM-2 Strain Gauge Interfaces

Battery Bank for Wind Turbine. Project Proposal Prash Ramani, Marcos Rived TA: Katherine O Kane

Smartdrive SmartIQ Pro packs

Area-Wide Road Pricing Research in Minnesota

The Benefits of Having a Municipal Electric Utility

White paper: Pneumatics or electrics important criteria when choosing technology

BMW GROUP DIALOGUE. HANGZHOU 2017 TAKE AWAYS.

Draglines. Product Line

Recharge Kick-off Meeting Recharge Activity Review Process for

PREDICTING BEARING FAILURES AND MEASURING LUBRICATION FILM THICKNESS IN YOUR PLANTS ROTATING EQUIPMENT

Developing PMs for Hydraulic System

Low and medium voltage service. Power Care Customer Support Agreements

Compression Tuning System

Project DG DemoNet-Concept Experiences of 3 Austrian Distribution Network Operators (DNO)

THE GREEK WAY ATHENS OVERHEAD WİRES AND SUBSTATİONS; PLANNİNG MAİNTENANCE AND OPERATİONS İN TİMES OF TİGHT BUDGET CONSTRAİNTS

Test Plans & Test Results

Presentation of NHIC Machine-tools dealer & Expert in industrial performance

Chapter 13: Application of Proportional Flow Control

Real-time Simulation of Electric Motors

RECOGNIZING FRANCHISING OPPORTUNITIES

Life Cycle Analysis - Case Study Examples. Fleet Management Passenger Boarding Bridge - Repair vs. Replace Decision

Measurement Products. WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications

Transcription:

Emerson Reliability Consulting Whitepaper May 2016 RCM & DMAIC Improvement Process: Eliminates Expensive CAPEX Improvement / Replacement Requirements, Reduces Process Variability & Rework and Mitigates Risk Michael Whittaker, Emerson Process Management Background Inherent problems in plant and equipment performance can result in frustration for many engineering managers, especially when it is causing the business significant costs to production. One tool for managers is to build a strong business case for a capital replacement or an improvement project, to eradicate the problem and move on to the next issue. This may be the right thing to do if every other option has been exhausted, but a costly option if the problem has not been fully understood. The capital replacement route can however be an easy option but a costly alternative certainly in times when capital funds are not readily available. By replacing the problematic equipment with a new design doesn t always get to the root cause of the problem, which invariably has a human or procedural element involved. The following is an example where the solution being sought was a business case to replace a problematic finishing process which had significant reliability issues, including a perceived over-complicated design and also some parts sourcing issues.

Definition A steel scrap baling system on a continuous annealing line was causing ~ 500,000 per annum in rework costs on final product (diversion of steel coils back to finishing units for final side-trimming, at a rate of approximately 20 coils per week). This was due to the unreliability of the scrap metal baler system. The initial requirement requested by the Engineering Manager was to review scrap baling process and associated issues to build business case for a CAPEX project to replace scrap baling system (initial view was complete redesign was required). Measure A failure recording regime was in place, with causes for coil diversions, due to scrap baler and associated sub-system failures being recorded. The analysis during 21 weeks of 2003 is shown below. From the initial data analysis it was apparent that there were several sub-system reliability issues, causing coil diversions and associated re-working requirements. 60 Baler Failures 2003 50 Number of Failures 40 30 20 10 Conveyor Hydraulic Proximity Hopper Weight Pusher Unit Table Fingers Roller Tabler Baler Door 0 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 Week Number Analysis In order to understand the whole-system issues, it was decided to conduct a reliability review of the scrap baler, using reliability centred maintenance (RCM) methods, in order to understand the problems fully and what the best solution would be for Business. People investment 12 Workshops approx. 2 hour duration 2 people per workshop = approx. 48 man hours Approx. ½ hour per failure mode www.emersonprocess.com/reliabilityconsulting 2

Control and monitoring equipment had been installed on the Baler to ensure safe and reliable operation. However, it became apparent during the RCM Analysis that there were no inspections or procedures in place to ensure that these systems remained in good working order. This was evident in the following examples: Filter Sensor Failures Hydac Unit Failures Proximity Switches Filter Sensors on Baler Lubrication System Functional Failure Failure Mode: Sensor Fails Failure Effect Fails to indicate filter condition Lubrication pumps would trip on current overload. Oil filter would be found to be blocked. Production cost 5000 Spare cost 50 Labour cost 100 Findings from the analysis of the Filter Sensors also uncovered the following: Filters changed on a regular basis not necessarily when needed Signals fed back to the PLC but not used Sensors never tested hidden failures Hydac Unit on Baler Lubrication System Functional Failure Failure Mode: Hydac unit Fails Failure Effect Fails to control the pressure of the lubrication system. Fails to maintain the lubrication oil at a temperature of between 35 & 50 degrees System could run with no control loss of lubrication oil resulting in catastrophic failure Oil temperature would become unregulated, pressure fluctuations should be picked up by pressure monitoring hydac unit Findings from the analysis also uncovered the following: The failure to control the pressure of the lubrication system could lead to a production cost of 650,000 A failure to control the temperature of the lubrication oil could lead to a production cost of 75,000 NB: Hydac units were failing at a frequency of one per year, at time of analysis. www.emersonprocess.com/reliabilityconsulting 3

Lubricating Oil Tank Level Proximity Switch Failures Functional Failure Failure Mode: Proximity Switch Fails Failure Effect Fails to alarm and trip if the lubrication oil drops or exceeds a certain level Pressure drops in system, baler will drop out of service. In the event of low low level alarm failure, baler will stop: Production cost 72000 Spare cost 38 Proximity switches fail Findings from the analysis also uncovered the following: The proximity switch provided no indication of failure The proximity switch formed part of the safety devices on the Baler. Solenoid Valve on Baler Lubrication System Functional Failure Failure Mode: Solenoid Valve Failure Failure Effect Fails to distribute lubrication oil to individual headers Lubrication oil is not directed to the liner plates causing catastrophic failure. Replacement of a full set of liner plates is required Production cost 650K Labor costs 1.8K Spare cost 70K Has not yet occured Functional Failure Failure Mode Failure Effect Fails to contain oil within the system Pipe-work failure between solenoid valve and header Lubrication oil is not directed to the liner plates causing catastrophic failure. Replacement of a full set of liner plates is required Production cost 650K Labor costs 1.8K Spare cost 70K Findings from the analysis also uncovered the following: No indication of failure from solenoid valves No redundancy in system to pick up failure www.emersonprocess.com/reliabilityconsulting 4

Implementation Revised maintenance and operational procedures developed, together with minor modifications. In addition, increased awareness of the operation and maintenance needs, as a result of the reliability analysis of the scrap baler, resulted in no requirement for CAPEX to replace baler. Process Output Identified 88 Failure modes Analyzed 83 Failure effects Creation of 41 PM Jobs Creation of 3 new Engineering Standards 4 recommended redesigns Control Reduced rework requirements from average of 17 coils per week down to average of 6 coils per week within six months of completing analysis and implementing key recommendations. Savings for the Company per annum of ~ 375,000 plus CAPEX saving, estimated to have been in excess of 1,500,000, were realised. Note: Management decision made to divert coils during weeks 14, 15 & 16, during period of high production requirements. Total Number of Coils Diverted for Baler Operations 25 Number 20 15 10 5 Diversions LCL Mean UCL 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Week Conclusions In this case, the need for an expensive capital investment was averted and significant process cost improvements were achieved with little additional costs, other than some simple modifications, which were more than covered by the reduction in re-work cost savings. In addition to the cost savings, the risks associated with potential hidden failures was far better understood, ensuring that the function and maintenance needs of the protective devices were being managed going forward. These significant benefits were achieved through a better understanding of the plant and equipment by the personnel responsible for operating and maintaining the plant. In the event that a new baler system had been purchased, then the danger would have been that the same issues of lack of understanding of the new plant could have raised itself over time. Instead, the learnings from the Reliability Centred-Maintenance output were documented and implemented into the PM system. It also meant that the satisfaction of resolving the problems, that had dogged the plant for several years previous, was more than apparent by the engineers and technicians responsible, with greater ownership for the asset care activities and a sense of achievement was borne. www.emersonprocess.com/reliabilityconsulting 5

The application of a DMAIC approach coupled with RCM is a powerful combination, especially where there are / may be multiple contributory (reliability) issues. The ability to analyse the whole-system, with RCM, was an essential element in the success of this example some other analysis techniques would look to resolve specific failures or would not have been able to identify the Significant X (in Six Sigma terms), due to the resolution of the data available. That should not detract from the DMAIC concepts which indeed provides a strong model to work to, in order to cut through perception and need for robust data. 2005: 193 coils diverted over 29 week period. mean weekly diversion = 6.7 coils (S.D. = 5.37) Frequency Mean Coils Diverted per Week = 6.7 Mean Coils Diverted per Week = 16.5 2003: 346 coils diverted over 21 week period. mean weekly diversion = 16.5 (S.D. = 12.27) IMPROVEMENT Population Therefore, Reliability Centred Maintenance should not be seen as something that the maintenance and reliability engineers use, but should be embraced as a process improvement technique, in conjunction with DMAIC and other improvement tools. These improvement techniques working together are in fact business improvement aids effective and able within the realms of risk-based management and challenging and / or validating capital improvement / replacement decision-making, by unlocking potential hidden capacity and waste within many organisations. These points are extremely significant nowadays, in a world of economic uncertainty and significant competition for capital funding and the need to maximise returns on assets. www.emersonprocess.com/reliabilityconsulting 6

RCM & DMAIC Improvement Process May 2016 Emerson Process Management Reliability Consulting 1100 Buckingham St., Watertown, CT 06795 T (203) 264-0500 www.emersonprocess.com/ reliabilityconsulting 2016, Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.