OPTIONAL VERTICAL OR HORIZONTAL POWER VENT KIT

Similar documents
OPTIONAL VERTICAL OR HORIZONTAL POWER VENT KIT

HIGH CAPACITY POWER VENT KIT

OPTIONAL HORIZONTAL VARIABLE DEPTH POWER VENT KIT

DV Power Vent System Model 7THPDVS

INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER

Installation Instructions

PVI-SLP Power Vent Inline

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Installation Instructions

AUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM

AUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM

Installation Instructions

Robert H. Peterson Co.

SECTION 6 PARTS LIST

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

Spare Parts Information List

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS EPK-1 PILOT KITS

Installation instructions for KIT15017, KIT15018, KIT15019, and KIT15020

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

SUMG-100. Burner Package & Components

PARTS MANUAL. PS314SBI Gas and Electric Ovens. Models: for domestic and standard export ovens PS314SBI Middleby Marshall, Inc.

Master Series Gas XPress Grill

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

A.O. SMITH WATER PRODUCTS CO., INC W. 115TH STREET ALSIP, ILLINOIS Phone: Fax: Website:

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS

ILLUSTRATED PARTS LIST

OVEN PARTS For Model: KEMS378BBL3, KEMS378BWH3, KEMS378BAL3 (Black) (White) (Almond)

Models: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT INSTALLATION AND OPERATING INSTRUCTION

Master Series. Gas XPress Grill. Parts List. Models, Non-CE & CE Versions: XG24 XG36

CATALOG OF REPLACEMENT PARTS

ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD. ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD.

CSA CERTIFIED Conforms to UL 507

Gas Convection Ovens UP TO

PARTS LIST WRANGLER 2625 DB

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

Installation Manual Installation and Appliance Setup

RC8900XAB0,RC8900XAQ0

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

PITNEY BOWES Sure-Feed Engineering SURE JET MODEL SJVB - TUV. Parts Manual. SJVB-TUVparts 1

Power Direct Vent PDV T Model

PARTS LIST WRANGLER 26-VS

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

KEY PARTS PS540-SERIES GAS OVEN KEY PARTS ITEM PART NO. ENGLISH DESCRIPTION QUANTITY

2500/2700 Series Gas Convection Oven

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO

NOTICE DO NOT DISCARD THIS MANUAL. Read, understand and follow these instructions for safe installation and operation.

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Installation Manual Installation and Appliance Setup

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

Pellet Furnace Last SN#

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

A.O. Smith Water Heater Parts Fulfillment 125 Southeast Parkway, Franklin, TN

CHEMICAL MIXING SYSTEM OPERATING AND INSTALLATION INSTRUCTIONS

Installation Manual. Installation and Appliance Setup

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

JODALE PERRY. Parts List & Mounting Instructions. Jacobsen HR9016 JDP BUILT FOR LIFE

SERVICE INSTRUCTIONS KEATING keatingofchicago.com

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

PARTS LIST WRANGLER 2625 DB

CATALOG OF REPLACEMENT PARTS

TC30 TRANQUILITY BURNER KIT INSTRUCTIONS

SANTAFE-MBK. Part number list on following page June 2, 2009 Page 1 of 5. Beginning Mfg Date: June 2009 Ending Mfg Date:

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

CATALOG OF REPLACEMENT PARTS

ML EX V SERIES 20KW / 30KW DOMESTIC MODEL 2010 ALLMAND BROS. INC. P.O. BOX 888 HOLDREGE, NE, USA 68949

Installation Manual. Installation and Appliance Setup

Installation Manual. Installation and Appliance Setup

Installation Manual. Installation and Appliance Setup

Air Conditioner for M915 A0/A1 Truck

PARTS LIST WRANGLER 2016 AE, AB, DB

Commercial Dryers Metered and Nonmetered ZE and ZG Models

PICCOLO Natural Gas / LPG Part Natural Gas (complete with fascia) Page 2 LPG (complete with fascia) Page 2

C. Exploded Views. 1 Glass Frame Post not sellable 2 Glass Frame Side not sellable 3 Glass Frame Spacer not sellable 4 Glass Frame, Top & not sellable

WRANGLER 2016 WHEEL DRIVE, PAD ASSIST & ELECTRIC MODELS

564 Shadowbox Face (w Screen) Instructions

Section 6: Parts Data

PARTS CATALOG M50/M80/M Volt and 24 Volt

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

REPAIR PARTS LIST MODEL 737AN MODEL 737AP. Valor Heating, Birmingham, England. Manufactured by. For MODEL 737CN 600A755/02

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

Q SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER ( MBH) REPAIR PARTS MANUAL. P/N , Rev. 1.2 [02/06]

Viking Installation Guide

MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

Transcription:

IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE INSTRUCTIONS These instructions are supplementary to the Installation and Operating Instructions supplied with the fi replace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions OPTIONAL ERTICAL OR HORIZONTAL POWER ENT KIT Power ent Terminal (TCT.502461) 5 x 8 Pipe (Simpson Duravent) (Secure ent) (Selkirk Direct-temp) ent Adaptor (5096.813) TCT.PB INSTALLATION AND OPERATING INSTRUCTIONS 060208-16 TCT.PB 5056.4265.B

Power ent Installation Locate the fireplace as per the main instructions supplied. Make the following modifications to add the components used with the Power ent Kits. This Kit can only be used in conjunction with the B & C series versions of Town and Country fireplaces. This installation must conform with local codes or, in the absence of local codes, with the Natural Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. Contents of Power ent Kit ITEM PART No. DESCRIPTION QTY. ITEM PART No. DESCRIPTION QTY. 1 TCT.502461 Power ent Terminal 1 7 5004.085 Tubing, TYSC-516316-100 1 2 5096.813 enting Adaptor 1 8 5093.01 Hose Clamp 2 3 TCT.5062515 Blower Wiring (pre wired to motor) 1 9 TCT.507156C Relay Wiring Harness, PC 1 4 TCT.506271C Pressure Switch Wiring 1 10 TCT.507156 On / Off switch wiring 1 5 9072.7 Pressure Switch Clip 1 11 TCT.506271 Pressure switch wiring 1 6 5027.1 Pressure Switch 1 12 5071.5 On / Off switch 1 Fig. #1 ENTING CONFIGURATIONS Maximum vent length is 110 ft plus six 90-degree elbows or combination of other elbows equaling 90-degrees, with a maximum 66 foot vertical rise. Minimum vent length is 3 ft plus one 90-degree elbow. The vent can be installed with any combination of rise and run between the fi gures including up to 3 ft below the unit. Ensure vent pipe is ertical Application must use TCT.PCA Box in conjunction with this kit 4 ft min. 6 ft min. Max. 66 ft Min. venting - 3 ft plus one 90-degree elbow Maximum venting - 110 ft plus six 90-degree elbows. 3 ft below unit (Max) to centerline of vent pipe MINIMUM CLEARANCES TO COMBUSTIBLE ertical vent pipe: 1.5 in. (38mm) Horizontal vent pipe: Top Sides Bottom 1.5 in. (38mm) 1.5 in. (38mm) 1.5 in. (38mm) All other clearances are as per the fi replace installation instructions. Fig. #1a WALL TERMINATION ENTING CHART A B C Minimum Rise Pipe Max. Min. Length Pipe Pipe Length Length TC30 TC36 TC 42 TC36ST 47 51 57 56 0 110 feet 3 feet 59 63 69 68 12 109 feet 2 feet 71 75 81 80 21 108 feet 1 foot *TC36 and TC36AR have the same dimensions 2 TCT.PB 060208-16

Fig. # 2 ENT TERMINAL MINIMUM CLEARANCES INSIDE CORNER DETAIL A G H D E B L F C B FIXED CLOSED OPEN- ABLE OPEN- ABLE A B FIXED CLOSED J A G I M K A ENT TERMINAL A AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED G GAS METER A= clearances above grade, veranda, porch, deck, or balcony [* 12 inches (30 cm) minimum] B= clearance to window or door that may be opened [* 12 inches (30 cm) minimum] C= clearance to permanently closed window [minimum 12 inches (30 cm) recommended to prevent condensation on window] D= vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (60 cm) from the edge of the terminal [12 inches (30 cm) minimum] E= clearance to unventilated soffi t [12 inches (30 cm) minimum] F= clearance to outside corner [6 inches (15 cm) minimum] G= clearance to inside corner [6 inches (15 cm) minimum] H= * not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator I= clearance to service regulator vent outlet [* 6 feet (1.8 m) minimum] J= clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance [* 12 inches (30 cm) minimum] K= clearance to a mechanical air supply inlet [* 6 feet (1.8 m) minimum] L= ^ clearance above paved side-walk or a paved driveway located on public property [* 7 feet (2.1 m) minimum] M= clearance under veranda, porch, deck, or balcony [12 inches (30 cm) minimum**] ^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the fl oor* * as specifi ed in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances * for U.S.A. Installations follow the current National Fuel Gas Code, ANSI Z223.1 060208-16 TCT.PB 3

1. Locate the power vent termination following the clearance to combustible table, venting confi guration diagram (Fig. #1 & 1a), and terminal location diagram (Fig. #2). 2. Cut and frame an 11 x 11 opening. The centre of the square hole should line up with the centre line of the horizontal pipe. Horizontal (Side wall) enting This kit uses either Simpson Duravent GS direct vent pipe, Secure ent direct vent pipe or Selkirk Direct-temp vent pipe with a 5 inner pipe and an 8 outer pipe. For part numbers see the table of venting components on page 8 of this manual. 3. Install the Simpson Duravent (or equivalent) Wall thimble, part number 1247 (not supplied with kit) in the opening to retain any insulation in the wall and maintain proper clearances. If the wall being penetrated is constructed of noncombustible material only (i.e.. Masonry block or concrete) the wall thimble is not required and a hole with zero clearance is acceptable. (8 hole) Fig.#3 Finished Wall 4. Attach the terminal to the outside wall. Ensure that the terminal is the right way up and that only the outer fl anges that are used to secure the terminal to the building are covered by the exterior wall or siding. (Fig.#3) Note: No other part of the terminal can be recessed into the exterior wall or siding. 5. Attach the vent adaptor directly to the appliance with three screws and seal outer pipe with aluminium tape provided. Note: The inner pipe does not need to be sealed. (Fig. #4) 6. Connect the high temperature silicone tube to the vacuum pressure tap on the adaptor, secure with the hose clamp provided and route the tube through any hole back to control box. (Fig. #4) Tube may touch unit and be trimmed if required. Note: Ensure that there are no blockages in this tube, as this will cause the control to malfunction. 7. Run the required Simpson Duravent GS / Secure ent / Selkirk Direct-temp pipe from the adaptor to the terminal assembly. Assemble as per the vent pipe manufacturer s instructions. Fig.#4 Power ent Adaptor. Part # 5096.813 MUST BE INSTALLED AT THE UNIT Secure with three screws and seal with foil tape Blower Outlet PRESSURE TAP Power ent Terminal Seal not required 4 TCT.PB 060208-16

ertical (Through Roof) enting This kit uses either Simpson Duravent GS direct vent pipe, Secure ent direct vent pipe or Selkirk Directtemp vent pipe with a 5 inner pipe and an 8 outer pipe. For part numbers see the table of venting components on page 8 of this manual. ertical installations must use the optional TCT.PCA vertical adaptor box in conjunction with this kit. The vertical adaptor box can only be installed on a fl at surface. Sloped surfaces require the construction of a chase which provides the minimum interior, square opening of 11 x 11 for the venting and wiring to pass through. Flat roofs may require a chase depending on local codes and roof construction. (If in doubt check with local inspector) The terminal must be located in accordance with the clearances outlined in Fig. #1 and 2. Installation: All part numbers in the following section are shown in Fig. #5. 1. Place the fl ashing (Part A) onto the chase and seal using silicone. 2. Put a bead of silicone on the underside of the vertical standoff (Part B) and place it on top of the fl ashing. Align the eight holes and secure both parts to the chase using eight #8 x 1 1/2 screws provided. 3. Install the drip shield (Part C) onto the top of the vertical standoff using a bead of silicone between the two. Do not screw this part in place. 4. Bring the 14-2 electrical wire (not supplied) up through the holes in both the fl ashing and the drip shield leaving at least 12 of excess wire above the drip shield. 5. IMPORTANT: Attach an appropriate length(s) of the vent to the power vent terminal, suffi cient to pass through the chase. NOTE: DO NOT CONNECT AN ADJUSTABLE LENGTH ENT PIPE TO THE TERMINAL. 6. Seal the connection of the fi rst length of pipe at the terminal and any other pipe to pipe joint by both screwing and taping the outside joint using high temperature foil tape. 7. Remove the junction box cover. (Part D) 8. Remove and discard the exhaust shield. (Part E) 9. Apply a bead of silicone on the bottom fl ange of the power vent terminal (TCT.PB) 10. Slide the vent through the drip shield and at the same time thread the electrical lead through the hole in the bottom of the terminal. 12. Join the 14-2 wire lead to the blower wires using the appropriate connectors and attach the ground wire. Reinstall the junction box cover. 13. Install the vertical rain cap (Part F) over the power vent blower. ALIGN THE EXHAUST OUTLET ON THE POWER ENT TERMINAL WITH THE EXHAUST PORT ON THE ERTICAL RAIN CAP. 14. Secure the vertical rain cap to the power vent blower with the remaining eight #8 x 1/2 stainless screws. NOTE: THERE ARE NO PILOT HOES IN THE BASE OF THE POWER ENT TERMINAL. 1/8 DIAMETER PILOT HOLES SHOULD BE DRILLED USING THE HOLES IN THE ERTICAL RAIN CAP AS A GUIDE. DO NOT SILICONE THE ERTICAL RAIN CAP TO THE POWER ENT TERMINAL AS IT NEEDS TO BE REMOABLE FOR SERICING. 15. Attach the vent adaptor directly to the appliance with three screws and seal outer pipe with aluminium tape provided. Note: The inner pipe does not need to be sealed. (Fig. #4) 16. Connect the high temperature silicone tube to the vacuum pressure tap on the adaptor, secure with the hose clamp provided and route the tube through any hole back to control box. (Fig. #4) Tube may touch unit and be trimmed if required. Note: Ensure that there are no blockages in this tube, as this will cause the control to malfunction. 17. Run the required Simpson Duravent GS / Secure ent / Selkirk Direct-temp pipe from the adaptor to the terminal assembly. Assemble as per the vent pipe manufacturer s instructions. 11. With the power vent terminal resting on the drip shield, align the eight holes in each of the vertical standoff, the drip shield and the power vent terminal and then screw them together using the eight #8 x 1/2 stainless screws provided. 060208-16 TCT.PB 5

ertical (Through Roof) enting Fig. #5 MUST ALIGN Part F ertical Rain Cap TCT.8074 #8 x 1/2" S.S. (16 Required) Power ent TCT.PB NOTE: Holes to secure rain cap are not predrilled Part E Exhaust Shield - DISCARD - Part D Junction Box Cover Part C Drip Shield #8 x 1-1/2" S.S. (8 REQUIRED) 14-2 Wire w/ Ground Part B ertical Standoff SILICONE ALL CONNECTING FACES Part A Flashing 18.000 11.000 11.000 18.000 Site Fabricated Chase Final Installation Height: 21" 6 TCT.PB 060208-16

Control System Connections Series B Town and Country Fireplaces 1) Remove window frame latch tool and set aside. 2) Remove 4 screws holding control panel in place and carefully lift off over the control knob. 3) Disconnect leads from the burner on/off switch and remove switch from control panel. Install double pole switch supplied with the kit. The new switch has 4 wire connection tabs, two left and two right. One side operates the power vent blower; the other side operates the burner control system. 4) Disconnect the battery pack red and black wires from the control system and remove the batteries and battery pack from the control box. The Power ent system only works on AC power. 5) Connect one end of the pressure switch wire lead to the pressure switch. Attach the pressure switch clip to the bottom left screw of the valve-mounting bracket and secure the pressure switch in place, see fi g #6 6) Connect the opposite end of the pressure switch wire, one lead to the burner on/off switch and the other to one of the brown leads (SWI) from the ignition module. Connect the remaining brown lead from the ignition module to the burner switch. Ensure that both leads, the brown lead from the module and the wire lead from the pressure switch are on the same side of the switch, see fi g# 7 7) Connect the on/off switch wire lead, provided with the kit, to the other side of the burner switch. this side controls the AC current for the power vent blower. 8) Remove two screws holding the upper control panel in place and carefully remove panel and set aside. Remove the electrical receptacle cover cover box, held in place with two screws, to access the AC wiring from the blower, see fi g #8. 9) Route the on/off switch wire through the 1/2 hole in the cover. Earlier units did not have an access hole in the cover and must be replaced with one supplied in the kit. 10) Finish all other wiring as necessary and replace receptacle cover box. 11) Attach the silicone tube from the pressure tapping on the vent adaptor to the low side of the pressure switch and secure using hose clamp provided, see fi g# 9. 12) Reattach both upper and lower control panels with screws previously removed. Fig. #6 Fig. #7 Brown lead (SWI) Securing screw Pressure switch clip low side of switch Pressure switch wire lead Wire from pressure switch WALL SWITCH INSTALLATION. If a wall switch is required the switch must be placed in the AC power supply for the control box. When using the wall switch ensure that the burner switch is in the on position. With the switch in this position, operating the wall switch to turn the fan on and off will also turn the fi replace on and off. WALL THERMOSTAT INSTALLATION (Canada only) Installation is the same as for the wall switch. Please note a 110v thermostat must be used. Fig. #8 Fig. #9 Two screws Hose clamp Receptacle box cover Silicone tube 060208-16 TCT.PB 7

Series C Town and Country Fireplaces The gas control system is located on the right hand side of the fi rebox behind an access panel and the decorative brick panel. 1) Remove burner grate, logs and brick panels if already installed. 2) Remove access panel from right hand side of the fi rebox. (Fig. #10) 3) Locate and disconnect the spade connectors in the black wire loop on the right side of the module and in the orange wire running from the module to the socket on the valve labelled pilot. (Fig. # 11 and 12) 4) Using the wires provided, connect the 120 hot supply wire to one of the black wires from the control module. Then connect the hot wire from the power vent blower to the other black wire on the control module. (Fig. #13) Fig. # 10 ACCESS PANEL Fig. # 13 Fig. # 11 SPADE CONNECTORS IN BLACK WIRE LOOP SUPPLIED WIRES TO CONNECT TO BLACK WIRE ON MODULE ORANGE WIRE FROM MODULE TO ALE Fig. # 12 HOT WIRE FROM BLOWER HOT WIRE FROM 120 SUPPLY 8 TCT.PB 060208-16

5) Connect the pressure switch pig tails to the orange wire. (Fig. # 14) Fig. # 14 6) Secure the pressure switch in the control box using the bracket provided with this kit. (Fig. # 14) PRESSURE SWITCH 7) Attach the silicone tube from the pressure tapping to the low side of the pressure switch and secure using the hose clamp provided. (Fig. #15) 8) Continue with installation and reassemble all of the parts previously removed. ORANGE WIRE Fig. #15 060208-16 TCT.PB 9

Wiring Diagram Series B Fireplaces Pressure Sensor Ignition Module Electrode HIGH LOW Black (S) [Through gas line conduit] Flame Sensor Burner Switch Black (I) [Through independent conduit] Pilot Gas Line 115 60 Hz 1.8A Fan Wire Harness Gas alve Battery Relay Orange AC Adapter Black TH TP Green Socket for AC Adapter Module Plug Black Black (TP) Ground Brown (SWI) Orange x2 (THTP) Green x2 (TH) Yellow Junction Box Red (+) Black Blue Optional wall switch or, if allowed by instalation code, Wall Thermostat White Black 10 TCT.PB 060208-16

Wiring Diagram Series C Fireplaces Power ent Fan 115 60 Hz 1.8A Optional Power ent Kit provided by Town & Country Electrical box inside Control Compartment 120 olt Common wire (White) 120 olt Hot wire (Black) Pressure Switch 120 olt Power AC Adaptor 1/4 Female Connector 1/4 Male Connector SWI (+) (-) Green White Orange Black 1/4 Male Connector 1/4 Female Connector Communication Wires AF-4000 Red Black Module Low volt relay Inside the module 1/4 Male Connector 1/4 Female Connector 1/4 Female Connector 1/4 Male Connector 120 olt Power Wall Switch Receiver 060208-16 TCT.PB 11

REPLACEMENT PARTS ITEM PART NUMBER DESCRIPTION QTY ITEM PART NUMBER DESCRIPTION QTY 1 5004.085 TUBE, 5/16 OD, 1/16 THICK 1 20 INSIDE COER 1 2 BLOWER POWER ENT 1 21 EXHAUST SHIELD 1 3 5027.1 PRESSURE SWITCH 1 22 SECONDARY RAIN SHIELD 2 *4 3/8 STRAIN RELIEF 2 23 JUNCTION BOX 1 5 #8 x 1/2 PAN HD SKT 18.8 STAINLESS STEEL 46 24 TOP COER 1 6 ID x.379 OD x.062 THK 2 25 EXHAUST SCREEN 1 7 1/4 MED LOCKWASHER 18.8 SS 5 26 FLASHING 1 8 STANDARD 18-8 SS, #8 FLAT WASHER 6 27 OUTLET AIR CHANNEL 1 9 SP100.25 x.75 AK 4 28 DRIP SHIELD 1 10 SCREW, #8-32 x1 1/4 RND HD 4 29 9072.7 PRESSURE SWITCH CLIP 1 *11 #8-32 x5/16 PAN QUADREX 1 30 ENT COLLAR 1 12 HEX NUT, STAINLESS 18-8 PLAIN 4 31 ENT EXHAUST ASSEMBLY 1 13 1/4-20 x1/2 NC GR 5 HEX C/S PLTD 5 32 ERTICAL RAIN CAP, TCT 1 14 5096.813 ENTING ADAPTER 1 33 ERTICAL STANDOFF 1 15 1/4 LDF PAPER 1 34 TCT.5062512 BLOWER WIRING 1 16 35 TCT.506271C PRESSURE SWITCH WIRING 1 *17 BUSHING, SHORTY B625 500 2 36 TCT.507156C RELAY WIRING 1 18 SIDE COER, RIGHT 1 *37 TCT.506271 PRESSURE SWITCH WIRING 1 19 SIDE COER, LEFT 1 *38 TCT.507156 ON/ OFF SWITCH WIRING 1 * NOT SHOWN ITEM 35 AND 36 ARE USED WITH SERIES C FIREPLACES ONLY ITEMS NOT SOLD SEPARATELY ITEMS 37 AMD 38 ARE UED ON SERIES B FIREPLACES ONLY 12 TCT.PB 060208-16

ENTING COMPONENTS SIMPSON DURAENT COMPONENTS SECURE ENT COMPONENTS Number Description 1208 6 Pipe Length 1207 9 Pipe Length 1206 12 Pipe Length 1204 24 Pipe Length 1203 36 Pipe Length 1202 48 Pipe Length 1211 11 to 14-5/8 Pipe, Adjustable 1217 4-10 Pipe, Adjustable 1245 45 Elbow 1290 90 Elbow 1240 Round Ceiling Support /Wall Thimble Cover 1241 Cathedral Ceiling Support Box 1242 Wall Firestop 1247 Wall Thimble 1263 Ceiling Firestop 1288 Wall Strap Number S5L6 S5L12 S5L24 S5L36 S5L48 S5LA S5LA12 S5LA24 S5E45 S5E90 S5CSB S5AC S5SU S5SD S5BM S5RSA S5RSM S5BF Description 6 Pipe Length 12 Pipe Length 24 Pipe Length 36 Pipe Length 48 Pipe Length 6 Pipe, Adjustable 12 Pipe, Adjustable 24 Pipe, Adjustable Swivel 45 Elbow Swivel 90 Elbow Adjustable decorative sq. cathedral support Collar for decorative sq. cathedral support Universal support Floor support Wall band Attic radiation shield Wall radiation shield Firestop SELKIRK DIRECT-TEMP Number Description 1605006 6 Pipe Length 1605009 9 Pipe Length 1605012 12 Pipe Length 1605018 18 Pipe Length 1605024 24 Pipe Length 1605036 36 Pipe Length 1605048 48 Pipe Length 1605082 4-10 Pipe, Adjustable 1605215 45 Elbow 1605230 90 Elbow 1605424B Cathedral ceiling support box (blk) 1605500 Firestop spacer 1605460B Wall thimble (blk) 1605430 Wall support band 060208-16 TCT.PB 13

NOTES: 14 TCT.PB 060208-16

NOTES: 060208-16 TCT.PB 15

TECHNICAL SUPPORT: 1-877-715-2664 www.townandcountryfireplaces.net 2975 Allenby Rd., Duncan, BC 9L 68 Printed in Canada