EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Similar documents
Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

TC abc. Three phase thyristor for resistive, inductive and temperature dependent (complex) loads CONTROLS DATA MANAGEMENT PROCESS AUTOMATION

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

The High Power Stack Horizon

Thyristor power units TC3000. Three-phase load control. User Manual

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Temperature Controllers

Temperature Controllers

Burst-Firing 74B5 LISTED INDUSTRIAL CONTROL EQUIPMENT. User Manual

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

J TS 7090 Thyristor power switch

RVS-DN Digital Reduced Voltage Motor Starter

Power Switching Principles

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Power Switching Devices

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Industrial Chargers and

GTS 15/25/40/50/60/75/90/120A

SECTION MOTOR CONTROL

Technical Description

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

GTS-L4 5 / 10 / 15 TECHNICAL DATA

A6Z OPERATING MANUAL

Industrial Power Supplies

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

RVS-DX Digital Reduced Voltage Motor Starter

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

Technical Data Sheets

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

MCD 200 Series Soft Starters

Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3)

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

SOLSTART Instruction Manual

EPS/ELA-Series User Manual EPS/ELA 250W

DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter

Load (2) Single or Dual

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Dimensions WxHxD [mm] Weight [kg]

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

RVS-AX Instruction Manual

Power factor correction Static switching units (Three phase).

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Technical Data Sheets

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

A3Z OPERATING MANUAL

SAV Electronic Valve Actuator

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

DART Charger Product Description, Information and Specification

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

Technical Data Sheets

Technical Data Sheets

SCR Power Controllers

DC3N Non-Regenerative DC Drives

Power Supplies POWER SUPPLIES TRANSIENT VOLTAGE SUPPRESSORS POWER LINE FILTERS. AC to DC Power Supply Units. AC to 24VDC Regulated Primary Switching

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

DYNACOMP. The top-class reactive power compensator

Thyristor Power Regulators

CD3000S-1PH Thyristor Unit Heater Break version

Non-Spring Return EconoDrive Floating Actuator

651 SERIES POWER CONTROL UNITS Single Phase, Phase Angle SCR Controller

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Features. Description. Table of Contents

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

Datasheet. Pitch Motor PMSM SP260B8

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Datasheet. Pitch Motor PMSM SP190C8

Technical Data Sheets

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

GTZ 25 / 40 / 55. THREE-PHASE SOLID STATE RELAYS WITH LOGIC CONTROL Vdc / Vac PROFILE. TECHNICAL DATA General features

SECTION DC POWER SUPPLY/BATTERY CHARGER

Datasheet. Pitch Motor PMSM SP190F8

CD3000S-1PH Thyristor Unit Analog Input version

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Safety technique. Emergency Stop Module BH 5928, BI 5928

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Description. Positive safety relays

Power Supplies. POWER SUPPLIES AC to 24VDC Regulated Primary Switching. TRANSIENT VOLTAGE SUPPRESSORS Industrial Design MINI UNIVERSAL MOUNT

Technical Data Sheets

Solid State Relays contactor with Integrated Fuse Type RGC1F

Description 1/8-7.5HP

Transcription:

TC2000 TC2001 EUROTHERM ONTROLS Two phase thyristor power switches Product data

TC2000 TC2001 Thyristor power switches Compact, two phase thyristor power switches for electrical heating applications from 100 to 690 volts, 60 to 1200 amps. Higher current ranges available with separate MC2001 driver and thyristor units. Economical three phase power control - The TC2000 and TC2001 use two thyristor pairs to switch the supply to two limbs of a three phase, three wire star or delta load. They can also control two independent single phase loads. The TC2000 and TC2001 work with logic or analogue inputs and deliver whole supply cycles to the load for minimum electrical interference. Compact size and low power dissipation - These units give space-efficient power control for three phase loads. Switching only two phases reduces by 33% the power dissipated by the thyristors. The compact size and lower dissipation mean that the control cubicle too can be more compact and less expensive. Better temperature control than contactors - For a reasonable lifetime, mechanical contactors cannot be switched too frequently. The resulting long cycle times cause temperature fluctuation. Shorter cycle times possible with thyristors mean power can be delivered exactly as it is needed to maintain a constant temperature. When used with analogue inputs the TC2000 and TC2001 also compensate for supply variations to hold load power constant and further reduce temperature changes. Low maintenance costs - Mechanical contactors in electrical heating applications can switch millions of times every year, resulting in relatively short lifetimes. The TC2000 and TC2001 have no moving contacts so will last almost indefinitely. Additional savings - The short on/off cycle times cause less heater expansion and contraction and reduce breakage due to fatigue and thermo-mechanical stress. Overall savings include reduced costs of new heaters, contacts, installation and lost production. The reduction of scrap also provides a positive benefit. TC2000 The TC2000 is suitable for controlling Resistive loads with low temperature coefficient. The firing mode is either Burst Firing for analogue inputs or Logic Firing for logic inputs. TC2001 The TC2001 is suitable for controlling Inductive loads including three phase transformers as well as Resistive loads with low temperature coefficient. The firing mode is either Burst Firing with adjustable delayed firing angle on first Cycle or Logic Firing. 2

The TC2000 and TC2001 thyristor units can each be used to drive either a single three phase 3 wire load or two independent single phase loads. Example of three phase load being controlled by a TC2000 or TC2001. Load connection 02 in ordering code. Ph 1 Ph 2 Ph 3 Temperature Controller Isolation and line protection I/P 1 Thyristor Unit or Example of two single phase loads being controlled by TC2000 or TC2001. Load connection 21 in ordering code. Ph 1 Ph 2 N Temperature Controller 1 Isolation and line protection Temperature Controller 2 I/P 1 Thyristor Unit I/P 2 Load 1 Load 2 3

TC2000 TECHNICAL SPECIFICATION 60A to 500A per channel Voltage 120V to 500V per channel (+10%, -15%) Supply frequency 50Hz to 60Hz Auxiliary supply 100V to 240V (+10%, -15%). No auxiliary supply for 60A and 75A logic input units without PLU option. Rating 5VA + fans Pollution Degree 2 (IEC 664) Storage temperature -10 C to 70 C Operating temperature 0 C to 50 C with unit mounted vertically. (40 C for 500A units) Cooling Convection cooling up to 75 amps Fan cooled from 100 amps with thermal switch for over temperature shutdown 100A and 150A: one fan 35VA 250A to 500A: two fans 70VA total Power dissipation Allow for 2Watts per amp per switched phase Environment Max. altitude 2000m Atmosphere: Non explosive, non-corrosive and non-conductive Humidity 5% to 95% RH non condensing. Safety Electrical protection TC2000 meets the essential protection requirements of European Low Voltage Directive 73/23/EEC dated 19/02/73 amended by directive 93/68/EEC dated 22/07/93. EN61010 installation category 3 (voltage transients must not exceed 4Kv) RC snubber network and varistor Built in high speed fuses for thyristor protection only. Line protection to be provided separately IP20 rated mechanical protection (front fascia) EMC standards Immunity Generic standard : EN 50082-2 Test standards : EN 61000-4-2, EN 61000-4-4 Emissions Generic standard : EN 50081-2 Test standards : EN 55011 Product standard : IEC 1800-3 The choice of the Conducted Emission applicable standard depends on the applications EN 50081-2 : with internal standard fliter for 60A and 75A nominal with internal optional filter (FILT option) for 100A and 150A nominal IEC 1800-3 : without filter. Applies for the second environment (industrial environment) EMC filter To reduce the conducted emissions that occur when using thyristor units, the EMC internal filter is added (standard for 60A and 75A; optional for 100A and 150A). Load Load type Load configuration Phase rotation Constant resistance Two leg control of three phase, three wire star or delta Dual independent single phase line-to-neutral or line-to line loads Phase rotation insensitive (except when PLU option fitted) Operation Firing modes Burst: Power level determined by analogue input. Cycle time 600ms at 50% power Logic: Cycle time defined by logic input Switches on zero crossing in both of the above firing modes Control mode Compensation for supply voltage compensation with burst firing only Analogue input DC voltage range: 0-5V; 1-5V; 0-10V; 2-10V Input impedance 68kΩ DC current range: 0-20mA; 4-20mA Input impedance 250Ω Manual input Using external 5kΩ potentiometer input configured for 0-5V Logic input DC voltage: ON>5V, OFF<1V (Max 25V), impedance 390 ohms AC voltage: ON>85V, OFF<10V (Max 264V), impdedance 10k ohms (50Hz) Partial load unbalance Detects 10% unbalance of line currents, fuse failure or short circuit of one thyristor Only with three phase loads Fuse blown microswitches 4

TC2000 ORDERING CODE Basic Product Load Config. Voltage Auxiliary Supply Input 1 Input 2 TC 2000 96/00 Load Configuration Three phase loads 02 Two single phase loads 21 60 amps 60A 75 amps 75A 100 amps * 100A 150 amps * 150A 250 amps* 250A 300 amps * 300A 400 amps * 400A 500 amps * 500A * Fan cooled Voltage 120 volts 120V 240 volts 240V 277 volts 277V 440 volts 440V 480 volts 480V 500 volts 500V Auxiliary Supply None 000 100 volts 100V 110 volts 110V 115 volts 115V 120 volts 120V 200 volts 200V 230 volts 230V 240 volts 240V No auxiliary supply required for 60A and 75A logic fired units without PLU Input 1 0-5 volts 0V5 1-5 volts 1V5 0-10 volts 0V10 2-10 volts 2V10 0-20mA 0mA20 4-20mA 4mA20 Logic dc input, 0-10V LGC Logic input, 0-240Vac ACL Input 2 Three phase loads 000 0-5 volt 0V5 1-5 volts 1V5 0-10 volts 0V10 2-10 volts 2V10 0-20mA 0mA20 4-20mA 4mA20 Logic dc input, 0-10V LGC Fuse fail microswitch FUMS Partial load unbalance (open in alarm) PLU Partial load unbalance (closed in alarm) IPU Internal EMC filter (100A and 150A) FILT (Standard on 60A and 70A) Note: PLU and IPU only avaliable for 3 Phase with analogue or DC logic input SPARE FUSES Unit current 60A 75A 100A 150A 250A 300A 400A 500A Fuse part no. LA172468U080 LA172468U100 LA172468U125 LA172468U200 LA172468U315 LA172468U400 LA172468U500 LA172468U630 Please note that replacement fuses are marked with a higher current rating than the thyristors. This allows correct operation at elevated temperature and does not imply that higher current is permissible. TC2000 5

TC2001 TECHNICAL SPECIFICATION 60A to 1200A Voltage 100V to 690V, line to line (+10%, -15%) Supply frequency 50Hz to 60Hz Auxiliary supply Up to 500A none (self supply), 750A to 1200A-115 or 230VAC fan supply Pollution Degree 2 (IEC 664) Storage temperature -10 C to +70 C Operating temperature 0 C to 50 C with unit mounted vertically. (40 C for 500A units) Cooling Convection cooled up to 75 amps Fan cooled from 100 amps with thermal switch for over temperature shutdown. 100A and 150A: one fan (24VDC 5w) 250A to 500A: two fans (24VDC 5w each) 750A to 1200A one fan 230V 115w (auxiliary supply) Power dissipation Allow for 2Watts per amp per switched phase Environment Max. altitude 2000m Atmospheres: Non explosive, non-corrosive and non-conductive Humidity 5% to 95% RH non condensing Safety TC2001 meets the essential protection requirements of European Low Voltage Directive 73/23/EEC dated 19/02/73 amended by directive 93/68/EEC dated 22/07/93. EN61010 installation category 3 (voltage transients must not exceed 4Kv) Electrical protection RC snubber network and varistor Built in high speed fuses for thyristor protection only. Line protection to be provided separately IP20 rated mechanical protection (front fascia) EMC standards Immunity Generic standard : EN50082-2 Test standards : EN 61000-4-2, EN 61000-4-4 Emissions Generic standard : EN 50081-2 Test standards : EN 55011 Product standard : IEC 1800-3 The choice of the Conducted Emission applicable standard depends on the applications EN 50081-2 : when used with correctly installed external filter IEC 1800-3 : without filter. Applies for the second environment (industrial environment) EMC filter - external Nominal current of Series filter Eurotherm part no. TC2001 product Two-phase control of a three phase load Control of two single-phase loads (2 filters) 60A FILTER/TRI/63A/00 FILTER/MON/63A/00 75A and 100A FILTER/TRI/100A/00 FILTER/MON/100A/00 For currents above 150A please contact Eurotherm Diagnostics Load Load type Load configuration Phase rotation Operation Firing modes Control mode Analogue input Manual input Logic input Connector for model 260 diagnostic unit for adjustment and monitoring of operating parameters Inductive, transformer or constant resistance load Two leg control of three phase, three wire star or delta Dual independent single phase line-to-neutral or line-to line loads Phase rotation insensitive Burst: Fast cycle 600ms or slow cycle 20s Logic: Cycle time defined by logic input Switches on at zero voltage for resistive loads, at zero current for inductive loads (adjusted by pot. on unit) Supply voltage compensation with burst firing only on standard unit. Power, I 2 or V 2 feedback with control board option DC voltage range: 0-5V; 1-5V; 0-10V; 2-10V Input impedance 100k DC current range: 0-20mA; 4-20mA Input impedance 50ohm Using external 4.7k to 10k potentiometer DC ranges as for analogue input CTE measurement option for use with: Bar graph Indicates level of controlled parameter and is used for setting firing delay for inductive loads Partial load unbalance Detects 10% unbalance of line currents, fuse failure or short circuit of one thyristor Only with three phase loads Fuse blown microswitches 6

TC2001 ORDERING CODE Basic Product Load Config. Voltage Auxiliary Supply Input 1 Input 2 Thyristor Firing Mode Controlled Parameter Measurem Bar Graphs TC 2001 96/00 Load Configuration Three phase loads 02 Two single phase loads 21 60 amps 60A 75 amps 75A 100 amps * 100A 150 amps * 150A 250 amps* 250A 300 amps * 300A 400 amps * 400A 500 amps * 500A 750 amps * 750A 900 amps * 900A 1200 amps * 1200A * Fan cooled Voltage 100 volts 100V 115 volts 115V 120 volts 120V 200 volts 200V 220 volts 220V 230 volts 230V 240 volts 240V 277 volts 277V 380 volts 380V 400 volts 400V 415 volts 415V 440 volts 440V 480 volts 480V 500 volts 500V 690 volts 690V Auxiliary Supply Self supply (up to 500A) 00 Fan voltage (for 750 to 1200A) 115V 230V Auxiliary (fan) supply required for 750-1200A units Input 1 0-5 volts 0V5 1-5 volts 1V5 0-10 volts 0V10 2-10 volts 2V10 0-20mA 0mA20 4-20mA 4mA20 Input 2 Three phase loads 00 0-5 volt 0V5 1-5 volts 1V5 0-10 volts 0V10 2-10 volts 2V10 0-20mA 0mA20 4-20mA 4mA20 Thyristor Firing Mode Logic (on/off) LGC Fast cycle burst FC Slow cycle burst SC Controlled Parameter Basic version - compensation for supply variations 00 Control board (must order option CTE) Load current squared I2 Load voltage squared V2 Active power W measurement for options: Control board Bar graph PLU Bar graphs Partial load unbalance (three phase only) Open in alarm Closed in alarm Fuse fail microswitch Note: Please specify options in order CTE BAR PLU IPU FUMS SPARE FUSES Unit current Fuse part no. 60A LA172468U080 75A LA172468U100 100A LA172468U125 150A LA172468U200 250A LA172468U315 300A LA172468U400 400A LA172468U500 500A LA172468U630 750A CS175632U630 900 CS175632U800 1200 CS175632U1000 Four fuses in total used in each TC2001 (2 fuses per leg) Please note that replacement fuses are marked with a higher current rating than the thyristors. This allows correct operation at elevated temperature and does not imply that higher current is permissible. TC2001 7

DIMENSIONAL DETAILS Front view Side view A Door B C Dimensions of units rated up to 500V* A B C Weight TC2000 and TC2001 60-150A 250A 300-500A* 480 480 570 133 248 248 268 268 268 10kg 16kg 16.5kg TC2001 only 750A 900-1200A 560 560 380 381 510 510 35kg 39kg * 690V units rated at 500amps or less have dimensions as shown for 500V, 500amp units in the table. Above 500amps, the dimensions of the 690V units are as shown in table. EUROTHERM CONTROLS LIMITED http://www.eurotherm.co.uk UK Region sales and service Eurotherm Controls Limited Faraday Close, Durrington Worthing West Sussex BN13 3PL Telephone Sales and support: (01903) 695888 Technical: (01903)695777 Fax (01903) 695666 Sales and support in over 30 countries worldwide For details of your local supplier contact: Eurotherm Controls Limited Faraday Close, Durrington Worthing West Sussex BN13 3PL England Telephone (+44 903) 268500 Fax (+44 903) 265982 Copyright Eurotherm Controls Limited 1998 All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Controls Limited. Every effort has been taken to ensure the accuracy of this specification. However in order to maintain our technological lead we are continuously improving our products which could, without notice, result in amendments or omissions to this specification. We cannot accept responsibility for damage, injury loss or expenses resulting therefrom. Part No. HA021432 Issue 5 Printed in England 0999