THE 4481 ADJUSTABLE TIMED OUTPUT MACHINE CONTROL

Similar documents
AUTO REEL -AS MODEL #: AS AUTOMATIC CORD REEL WITH AUTO SAFE INSTRUCTION MANUAL

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

MODEL 422 Submersible Pump Controller

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Application Engineering

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

INSTALLATION GUIDE. Universal System for Zero Turn Mowers

Owner s Manual. Features

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Application Engineering

Generator Start Control Module

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

TCM D Single Zone, 24 Volt DC Timer Control Module User s Manual D-M-E Company

INSTALLATION & OWNER'S MANUAL

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CRD400 Fitting Inserter OPERATIONS MANUAL

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

Control Relays Overview

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

Installation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596

Generator Start Control Module

Installation Instructions for Eaton Surge Protective

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

GENERATOR START CONTROL MODULE

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

MAGNAGLIDE AIR OPERATOR VERTICAL MOUNT

The Da-Lite Difference.

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

DPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

TC26-B Vehicle Sensor

# Traction Control Window Switch

Electropneumatic Timing Relays Series 7000 Industrial

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

RHINO MOTION CONTROLS

AIR COOLED RECTIFIER SPECIFICATION S-50-A

1 AMP CURRENT SOURCE

RU BMS Power Supply and Battery Management System Owners Guide

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Electro Wizard Battery Disconnect Switch

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

SCHNITZ MOTORSPORTS PNC-202, 2-STAGE PROGRESSIVE NITROUS CONTROLLER USER MANUAL AND INSTALLATION GUIDE NOS PULSE FREQUENCY

Installation Instructions

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MST. model. alvaradomfg.com

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

Air Shift Module User Manual

TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

Installation and Operation Guide

Utility Controller Hand Air Operated

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

MJ81BK MJ93BK MJA3BK Parameters VAC Supply Variation. Cat. No. ORDERING INFORMATION. -20% to + 10% (of ) Frequency

DPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

SURE TRIP RETRO KITS

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

GENERATOR START CONTROL MODULE

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

INSTRUCTION MANUAL ENGINE IDLER MODEL # VOLTGAE MONITOR MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Installation and Maintenancee Manual

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

ERD Electrically Released Brakes

Updated: October 2012

MINIATURE CIRCUIT BREAKER

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

The Da-Lite Difference.

Electrical: Valve monitoring and control circuits

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

SB SWITCH CONTROL BOX

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

USER'S MANUAL MODEL DPD60001 MICROSTEP DRIVER PACK

CRD610 Automatic Fitting Inserter

MLA Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

CRD600 Automatic Fitting Inserter

MST. Full Height Turnstiles. alvaradomfg.com

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

AUTO ISOLATOR I AN AUTOMATIC LOSSLESS BATTERY ISOLATOR FOR DUAL BATTERY SYSTEMS

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

12 Volt Utility Controller for 4, 6, or 8 Brakes No

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

INSTRUCTION MANUAL ENGINE IDLER MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

A1P OPERATING MANUAL

Generator Start Control Module

Heavy Duty Industrial Foot Switches

MAGNETIC MOTOR STARTERS

Horizontal Circuit Switchers

Transcription:

Anti-Tiedown Control THE 4481 ADJUTABLE TIMED UTPUT MACHINE CNTRL The 4481 control has all the anti-tiedown switch monitor features of the 4480 control with the added feature of a knob adjustable timed output. The 4481 can be configured to operate in one of the following ways: Timed utput - After both start switches are pressed, the load will remain energized until the time cycle is completed or a start switch is released. 1 1 C NT Maintained Timed utput - An optional "Hold" switch is wired to the control. When this switch is closed the load will remain energized even after the start switches are released. This switch must not be closed until after the pinch point is passed. Delayed Timed utput - The load will remain energized until the time cycle is completed or a start switch is released. However, the time cycle will not begin until an optional "Delay" switch is opened. Part# 4481-5 Part# 4481-10.5-5 econd utput 1-10 econd utput LIMITED NE YEAR WARRANTY Nolatron, Inc. warrants its products against defects in material and workmanship under normal and proper use for a period of one year from date of shipment. Nolatron's obligation under this warranty is limited to furnishing, without charge and at our discretion, either replacement or repair of any defective part. This warranty does not apply under the following conditions: (1) When the product has been operated at other than specified voltage or currents. (2) When the product has sustained contact damage due to improper load arc protection. (3) When the product has been subjected to abuse or has otherwise been tampered with. The foregoing warranty is exclusive and in lieu of all other warranties of quality whether written, oral, or implied. Nolatron is not liable for any damage or injury which may result from the use of these products. R L & E N R WARNING These controls are not intended for use without adequate "point of operation" safety guards, which must be provided for the operator's protection. The user must see that the control is properly installed, cared for, and operated to meet all applicable local, national and HA codes and requirements. The user must also determine the compatibility and safety of switching devices used with the switch monitor. Failure to comply could result in serious bodily injury and/or property damage. Toll Free 1-800-526-5376 201-337-1000 Fax 201-337-1862 879

TW HAND MACHINE CNTRL ANTI-TIEDWN TIMER ERIE 3380 Nolatron's anti-tiedown controls are used in conjunction with two start switches to help protect machinery operators. The 3380 series helps to comply with HA, which requires a machine operator to have both hands on the start switches in order to start a machine cycle. This minimizes the possibility of the operator starting the machine while one hand is in the work area. Both start switches must be activated within a fixed time interval to energize the output. This prevents an operator from "tying down" one of the switches while continuing to operate the machine. The 3380 uses redundant positive guided output contacts which are cross-checked before every machine cycle. A single component failure will cause the control to shut down in a safe mode. Features: Anti-Tiedown Control UE REDUNDANT PITIVE GUIDED RELAY Double "positive guided" output relays- Each relay is checked for proper status prior to beginning a machine cycle. Pin for pin compatibility- The 3380 series can be used to replace the 3370 and 5570 series controls with no modification to wiring.* This allows easy upgrading of existing machinery. Control reliable- The 3380 series is designed to meet the HA classification of "control reliability" as defined in section 1910.217 (13). *Note:The 3380 series does not offer the normally closed output contact (pin number 4 of the 3370 series). Also, the switching output current rating of the 3380 is 8 amps, the 3370 series is rated for 10 amps). pecifications: Physical Wiring Connection perating Voltage Power Consumption utput Ratings 3 1/2"(88mm) High, 2 3/8" (60mm) Wide, 1 3/4" (45mm) Deep tandard 8 pin octal base (socket sold separately) 115 VAC, 50/60Hz. (12 and 24VAC also available).3 Watts (pin 3 energized) / 6 Watts (pin 2 energized) 8 Amps @ 115 VAC (switching), 6 Amps @ 115 VAC(continuous) 880 www.relayspec.com sales@relayspec.com

Anti-Tiedown Control UGGETED WIRING FR MDEL 3380 MMENTARY UTPUT: In order for a machine cycle to begin, both start switches must be pressed within.5 sec. (this time is internally adjustable). The output will remain energized as long as the start switches are depressed. The optional Reset switch can be opened to end the machine cycle regardless of whether the start switches are depressed. In some applications the Reset switch is used as a means to provide a "single stroke" of the machine. Both start switches must be released before another machine cycle can be started. If either start switch is "tied down", the cycle can not be repeated. MAINTAINED UTPUT: In order for a machine cycle to begin, both start switches must be pressed within.5 sec. (this time is internally adjustable). The output will remain energized as long as the start switches are depressed. Closing the optional Hold switch will allow the load to remain energized after the start switches are released.the Hold switch must not be closed until the pinch point is passed. The Hold switch should stay closed for the rest of the machine cycle. The Reset switch can be opened to end the machine cycle regardless of whether the Hold switch is closed or the start switches are depressed. Both start switches must be released before another machine cycle can be started. If either start switch is "tied down", the cycle cannot be repeated. Note: The Reset and Hold switches shown in the above wiring diagrams are optional and are not required for all applications. 1 1 C NT R L & E N R UGGETED WIRING FR MDEL 3380-T TIMED UTPUT: In order for a machine cycle to begin, both start switches must be pressed within.5 sec.(this time is internally adjustable).the output will energize the load for.5 sec. assuming that the start switches remain depressed. (The output time is internally adjustable with a range of.2-1 sec.). Both start switches must be released before another machine cycle can be started. If either start switch is "tied down", another cycle cannot be repeated. Toll Free 1-800-526-5376 201-337-1000 Fax 201-337-1862 881

Anti-Tiedown Control APPLICATIN NTE HAND WITCHE - The 3380 and 3381 series are designed to operate with mechanical hand switches only. The normally closed and normally open contact of each switch must be isolated and of the "break before make" type. The user must determine the compatibility and safety of the hand switches. These controls are not designed to be interfaced with electronic hand sensors (request information on series 4480 & 4481). LAD CIRCUIT - Whenever possible, the load should receive power through the start switches as shown to the right. In this circuit if either start switch or the reset switch is opened, the power to the load will be interrupted by the switch as well as the output relay contacts. This circuit will offer additional safety when deenergizing the load. 1 1 C NT R L LAD TRANIENT DAMAGE - If the load is a solenoid, a motor, a relay coil or a transformer, it will have inductive properties.when a relay contact breaks the current to an inductor, a high voltage will result across the contact. This high voltage may damage the contacts when they begin to separate. Good transient suppression (placed across the load) can greatly reduce this damaging high voltage and increase operating life. rder Nolatron Part # 30165 - Load uppressor LIMITED NE YEAR WARRANTY: Nolatron, Inc. warrants its products against defects in material and workmanship under normal and proper use for a period of one year from date of shipment. Nolatron's obligation under this warranty is limited to furnishing, without charge and at our discretion, either replacement or repair of any defective part. This warranty does not apply under the following conditions: (1) When the product has been operated at other than specified voltage or currents. (2) When the product has sustained contact damage due to improper load transient protection. (3) When the product has been subjected to abuse or has otherwise been tampered with. The foregoing warranty is exclusive and in lieu of all other warranties of quality whether written, oral or implied. Nolatron is not liable for damage or injury which may result from the use of these products. & E N R WARNING: These anti-tiedown controls are not intended for use without adequate point of operation safety guards. It is the user's responsibility to assess all potential hazards when installing safety equipment. The user must see that these controls are properly installed, cared for and operated to meet all applicable local, national and HA codes and requirements. Failure to comply could result in serious bodily injury and/or properly damage. Toll Free 1-800-526-5376 201-337-1000 Fax 201-337-1862 883

Anti-Tiedown Control UE REDUNDANT PITIVE GUIDED RELAY TW-HAND MACHINE CNTRL ANTI-TIEDWN WITCH MNITR ERIE 4480 Nolatron's 4480 witch Monitor is designed for use with singlepole hand sensing devices, such as optical touch buttons. It provides two hand control for presses, welders, molders, and various production machines. The 4480 also helps to comply with HA, which requires an operator to have both hands on start switches in order to begin a machine cycle. This minimizes the possibility of an operator having one hand in the work area when a machine cycle is started. If one or both start switches are "tied-down", the control will not allow a new machine cycle to begin. The 4480 series can be used to replace the Nolatron 4470 series with no modification to wiring. MDEL 4480 l CMPATIBLE WITH INGLE PLE HAND ENING DEVICE l UE REDUNDANT PITIVE GUIDED RELAY l MEET THE HA CLAIFICATIN F 'CNTRL RELIABILITY' l UE A DETACHABLE TERMINAL TRIP FR EAY INTALLATIN AND REMVAL The 4480 meets the HA classification of "control reliability" as defined in section 1910.217 (13). It uses redundant output contacts which are cross-checked before every machine cycle. The failure of any component will cause the control to shut down in a safe mode. ne year full warranty. 884 www.relayspec.com sales@relayspec.com

Redundant utput Contacts The 4480 series uses double "positive guided" output relays. Each relay is checked for proper status prior to beginning a machine cycle. Hand witch Inputs The 4480 switch monitor is designed to interface with dry contact, single pole hand switches and electronic hand sensing devices with relay output. The 4480 features a hand switch delay which requires each hand switch to be closed for a set amount of time (factory set at.075 seconds) in order to activate. When in the open position, 24-40 volts DC will be across the hand switches. When in the closed position, 60-80 milliamps will flow through each hand switch. FEATURE F THE 4480 ERIE Control Reliability Anti-Tiedown Control The 4480 series is designed to meet the HA classification of "control reliability" as defined in section 1910.217 (13). Low Voltage Detector The low voltage detector inhibits operation and causes the control to reset if power supply voltage drops below 90VAC (115V application). The 4480 will also reset on brief dips in supply voltage. (Note: ome hand detection devices will operate erratically under low voltage conditions. Therefore, these devices should be connected to the same power source as the 4480 so they can be monitored). 1 1 C NT R L Anti-tiedown Model 4480 is activated by depressing the two hand switches within a fixed period of time (factory set at.5 sec.). The load will remain energized until one or both start switches are released or the reset switch is opened. If one or both switches are tied-down, the 4480 monitor will not operate. Universal Power Configuration The 4480 series allows 115 or 230 volt operation at 50 or 60 Hz. Physical Dimensions: Weight: Power Requirements: Power Line Monitor: utput Load Rating: utput Life: Hand witch Delay: Hand witch Concurrency: Delay on Power-up: Temperature Range: rigin: ystem Check Cycle When the power is turned on, the 4480 will begin a 5 second system check cycle. During this check, the output is disabled and a machine cycle cannot be initiated. If the operator's hands are on the start switches during the system check, the output will not be energized until both hands are removed and reapplied. Detachable Terminal trip The 4480 is wired using a detachable terminal strip, which makes installation and removal of the 4480 much easier. pecifications 4.7" x 4.3" x 2.0" (l x w x d) 1.25 lbs 115 VAC, 50/60Hz @.1 A or 230 VAC, 50/60Hz @.05A (24v model also available). Resets if supply drops below 90V RM (120V application) or 180V RM (240V application) for more than 15 ms. 8 Amps @ 115/230VAC (switching), 6 Amps @ 115/230VAC (continuous). 10 million mechanical operations (minimum)..05 to.15 seconds (factory set at.075 seconds). 0 to.7 seconds (factory set at.5 seconds). 5 seconds (approximate). 0-140 F. Made in the U..A. & E N R Toll Free 1-800-526-5376 201-337-1000 Fax 201-337-1862 885

UGGETED WIRING FR THE 4480 ERIE Anti-Tiedown Control MDEL 4480 MMENTARY UTPUT - In order for a machine cycle to begin, both switches must be activated within.5 seconds. The load will remain energized until one or both start switches are released or the Reset switch is opened momentarily. MAINTAINED UTPUT - An optional Hold switch can be wired into the circuit of the 4480 to provide a maintained output. When the Hold switch is closed, the load will stay energized even after the start switches are released. The Hold switch must not close until the pinch-point is passed, and should remain closed for the rest of the machine cycle. MDEL 4480-T TIMED UTPUT - This model has the added feature of an adjustable timed output. When both start switches are activated, the output will remain energized until the time cycle is completed or one or both start switches are released. The output time is factory set at.5 second, and is internally adjustable from.2 to 1 second. MDEL 4485 PLC INTERFACE - Model 4485 has all the anti-tiedown features of the 4480 plus the ability to interface with programmable controllers that have DC inputs of the sinking or sourcing configuration. When a PLC is used to start a machine cycle, an anti-tiedown control must be used to help prevent an unwanted energizing of a machine load due to PLC failure. Note: The Reset & Hold switches shown in the above wiring diagrams are optional and are not required for all applications. LAD TRANIENT DAMAGE If the load is a solenoid, a motor, a relay coil, or a transformer, it will have inductive properties. When a relay contact breaks the current to an inductor, a high voltage will result across the contact. This high voltage may damage the contacts when they begin to separate. Good transient suppression (placed across the load) can greatly reduce this damaging high voltage and increase operating life. rder Nolatron Part#: 30165 - LAD UPPRER 886 www.relayspec.com sales@relayspec.com