GENCORE 5 FUEL CELL SYSTEM System Fundamentals

Similar documents
Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

Section 3 Technical Information

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

AT30 SERIES BATTERY CHARGER

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Technical Data Sheets

Illuminator Series CR NEMA 3R

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Mistral LC-MS Evolution Specification

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Technical Data Sheets

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

E-15 Uninterruptible Power Systems (UPS)

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Power+ CLASSIC. 20/30 kva, 3x208 Vac

NetSure. 211 Series DC Power System

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

3 Uninterruptible Power Systems

Technical Data Sheets

Aurora Single Phase Emergency Lighting Inverters

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

MKN-DSP SERIES - THREE PHASE

Technical Data Sheets

EATON 9315 UPS 200 TO 300 KVA Specifications

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

POWERTRONIX QUASAR 5-40 KVA

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

Product Specifications

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

3 Uninterruptible Power Systems

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

Technical Data Sheets

Liebert PowerSure PSI UPS

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Uninterruptible Power Supplies

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Three Phase UPS Systems Range: 10 to 500kVA

TECHNICAL DATA SHEET KVA UPS Systemss

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

METHANOL-FIRED FUEL CELL POWER SYSTEM FOR REMOTE APPLICATIONS

PowerCommand 2100 digital generator set control

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

AT EVO SERIES BATTERY CHARGER

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Application. Battery. Public Grid GS HYBRID INVERTER

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

Technical specification

Security Plus Online Uninterruptible Power Supply

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

SPECIAL SPECIFICATION 6576 Solar Panel Power Supply System

E-15 Uninterruptible Power Systems (UPS)

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

Diesel generator set QSX15 series engine

GE.VO.360/325.SS+0_all

SCC-MPPT Solar Charge Controller

Paralleling Equipment

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

S&C PureWave UPS System Outdoor Distribution (2.5 to 20 MVA, 5 to 25 kv)

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Solar Charge Controller

SCC-MPPT Solar Charge Controller

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Technical data sheets

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Dynamic Behaviour of a Fuel Cell with Ultra Capacitor Peak Power Assistance for a Light Vehicle

Uninterruptible (ATX) Switching Power Supply. MODEL eups-350

Technical Data Sheets

Sola 3000 Guide Specifications

Diesel generator set QSX15 series engine

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

BRAVER UPS. (Uninterruptible Power System) User s Manual

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Transcription:

GENCORE 5 FUEL CELL SYSTEM System Fundamentals GenCore 5T48 GenCore 5B48 GenCore 5U48 GenCore 5T24 GenCore 5U120 Revision 1 December 1, 2004

GENCORE DESCRIPTION GenCore fuel cell systems are direct hydrogen fueled proton exchange membrane (PEM) fuel cell systems, designed specifically to provide back-up power to Telecommunications, Cable Broadband and UPS (Uninterruptible Power Supply) applications. Designed to replace valve regulated lead acid batteries (VRLA) GenCore systems are a direct DC power source, which offer significant value to our customers. GenCore 5 w/o fuel storage The GenCore 5 fuel cell system is a hydrogen fueled back-up DC power generator with a net power output of 5kW. The product is designed to provide backup power for telecommunication, broadband, industrial, and utility applications. The following configurations are available: 5T48 5B48 5U48 5T24 5U120-48VDC output designed for direct DC buss interconnection in telecommunications wireline and wireless applications. +48VDC output to interface with most widely available cable-broadband power nodes via battery DC link. +48VDC floating ground output designed for industrial, utility, and backup applications. +24Vdc output designed for direct DC buss interconnection in telecommunications wireline and wireless applications. +120VDC output designed for industrial and backup applications. Available in both normal and floating ground configurations. Optional Hydrogen Storage Module Power Generation Module Electrical Connection Fuel Connection Figure 1: GenCore 5 Fuel Cell System with Optional Hydrogen Storage Module Page 2

GENCORE SPECIFICATIONS Table 1 shows the specifications for the Gencore TM 5 fuel cell system. Table 1: Fuel Cell System Specifications PRODUCT CHARACTERISTICS 5T48 5B48 5U48 5T24 5U120 Performance Net Output 1 0 to 5,000W Adjustable Voltage 46Vdc to 56Vdc Output +46Vdc to +56Vdc +23Vdc to +28Vdc +125.9Vdc to 136.2Vdc Operating Range 42Vdc to 60Vdc Voltage +42Vdc to +60Vdc +21Vdc to +30Vdc +125.9Vdc to 139.8Vdc Operating Range 0 to 109 Amps Current 0 to 218 Amps 0 to 39.9 Amps Grounding Normal Floating Fuel Gaseous Hydrogen 99.95% (dry) Supply Pressure 80 +/- 16 psig Fuel Consumption 40 slm at 3,000W 75 slm at 5,000W Operation Ambient Temperature -40C to 46C Relative Humidity 0% to 95% non-condensing Altitude -197ft to 6,000ft Physical Dimensions 44 x 26 W x 24 D Weight 500 lbs Safety Compliance FCC Class A ANSI Z21.83 UL Telcordia GR 63, 78,487, 1089 Emissions Water Maximum 2.0 liters per hour Co, CO2, NOx, SOx <1ppm Audible Noise 60dba @ 1m Sensors Gas Hazard Sensor Pad Shear O O O O O Water Intrusion O O O O O Tampering O O O O O Control Microprocessor w/diagnostics 2 LED Alarm Panel Communication RS-232 Digital Form C output Modem O O O O O Multiple System Connection O O O O O GENCORE CONSTRUCTION AND SUBSYSTEMS The GenCore 5 fuel cell system is designed for outdoor installation and consists of a standard Power Generation Module and an optional Hydrogen Storage Module. The Power Generation Module may be Page 3

operated independently using an external hydrogen supply or can be operated using the Hydrogen Storage Module. The Hydrogen Storage Module is a self-contained unit that houses 6 hydrogen cylinders and provides all the required pressure regulation and valving. Block diagram is shown in Figure 2. Fuel Cell System H 2 Internal DC Bus Main DC-DC Converter External DC Bus Hydrogen Fuel Auxiliary DC-DC Converter Internal Battery Normal operation (Fuel cell in standby mode) Abnormal operation (Fuel cell in running mode) Fuel cell startup from internal battery Figure 1: GenCore 5T fuel cell system block diagram Power Generation Module Figure 2: GenCore 5 Functional Diagram The Power Generation Module contains the fuel cell stack, power conditioning electronics and auxiliary components. See Figure 3. DC to DC Converter 112cm Humidifier Cell Scanner Card GenCore Control Card Fuel Cell (PEM ) Stack Cooling Radiator Recirculation Blower EE Storage Module Figure 3: GenCore 5 Fuel Cell System and Sub-Systems Fuel Cell Stack The fuel cell stack is made up of individual fuel cells, each with a proton exchange membrane (PEM) between two plates. The cells are connected in series with a collector plate at the stack top and bottom providing high current connections to the external circuit. The electrochemical process produces DC electricity with heat and water as byproducts. The fuel cell stack is the heart of the system. Individual cell Page 4

voltages are measured and the fuel cell stack Cell Voltage Scanner Card provides inputs to the control subsystem. Refer to Figure 4. There are no field serviceable components in the stack. If the stack requires corrective service it will be replaced with a new stack and the old stack sent back to the manufacturer for repair/refurbishment. Cell scanner card Cooling Subsystem Figure 4: GenCore 5 fuel cell stack The electro-chemical reaction that takes place inside the fuel cell stack is an exothermic reaction and therefore the generated heat needs to be managed. The primary function of the cooling system is to maintain stack coolant Inlet temperature within an acceptable operating range. The coolant temperature determines the stack temperature that is an important factor in PEM performance and gas stream relative humidity. An automotive style radiator filled with a coolant consisting of a pure, uninhibited, Propylene Glycol/Deionized water mixture. Uninhibited Propylene Glycol is used because it is an environmentally friendly, a low cost heat transfer fluid and is highly resistive, ensuring minimal leakage current across the electrically charged stack plates. This coolant is non-flammable. A thermostat at the top of the header directs the coolant down out of the coolant bypass port when the coolant temperature is low returning it directly to the pump. When the coolant heats up the thermostat opens allowing hot coolant to be directed to the radiator for cooling before returning to the pump suction. Stack Anode Hydrogen Subsystem The stack anode hydrogen subsystem provides the transport and control of the Hydrogen (H 2) to and from the fuel cell stack. Page 5

Stack Cathode Air Subsystem The stack cathode air subsystem provides the transport and control of the air to the fuel cell stack from ambient and the process exhaust out of the fuel cell stack. Humidifier The humidifier functions to transfer heat and humidity from the cathode exhaust to the cathode inlet air stream. Battery The battery forms part of the power conditioning subsystem and is located in the bottom of the fuel cell system, accessible from the rear service panel. The battery consists of 4 series connected, 12VDC valve regulated lead acid batteries and is used to store energy to supply energy during fuel cell system power transients and for limited operation without the electrical grid when the fuel cell stack is not available, i.e. to start the fuel cell. The battery sits in parallel with the customer DC bus and is under normal operation kept in a charged state by the customer connection rectifying equipment. DC-DC Converters The converters forms also part of the power conditioning subsystem and consist of the main DC-DC converter, the auxiliary DC-DC converter and communications circuits for integration into the fuel cell system. During fuel cell system operation, the main DC-DC converter converts the varying fuel cell stack output voltage to a settable constant DC voltage for use by the fuel cell system auxiliaries and the connected load equipment. When the fuel cell system is in Idle mode it receives DC power from the customer rectifying equipment to power the fuel cell system auxiliaries. The auxiliary DC-DC converter takes the power from the main DC-DC converter and converts it to 24Vdc that is used by the GenCore Control Card for control, communications and power functions. An RS485 bus is used for internal communications and the control card also receives inputs from a battery current sensor and a voltage signal from the customer DC bus. Multiple System Operation For higher output power needs, up to four GenCore 5 systems can be combined for outputs up to 20kW. Utilizing a factory-installed optional LAN card, multiple systems can be operated in a combined mode with one GenCore acting as the central controller with others following. Hydrogen Storage Module The Power Generation Module, shown in Figure 5 may be operated independently using an external hydrogen supply or can be operated using the Hydrogen Storage Module. The Hydrogen Storage Module is a self-contained unit that houses 6 hydrogen cylinders and provides all the required pressure regulation and valving as shown in Figure 1. The Hydrogen Storage Module has a control panel that allows the user to select the primary cylinder bank, close supply valves and check pressures. The module is divided into 2 cylinder banks each consisting of 3 cylinders. This arrangement is necessary to ensure that cylinder replacement can be affected without interrupting fuel supply to the Power Generation Module. The selection between the 2 cylinder banks is done via the auto changeover regulator that serves as a pressure-reducing regulator and as an automatic bank selection valve. The bank selector valve sets the primary cylinder bank. Whenever the primary cylinder bank pressure drops below 85psi, the changeover regulator will automatically switch over to the secondary cylinder bank. Page 6

Each cylinder is equipped with a manual valve to isolate the bank during refueling and a main isolation valve which also acts as an emergency shutoff valve is located on the outside of the controls enclosure to shut off all fuel to the Power Generation Module. High pressure gauges are provided for each cylinder bank to indicate available fuel and a low pressure gauge is provided downstream of the regulator which displays the supply pressure to the Power Generation Module. An excess flow valve is provided as a safety device that shuts off flow in the event of a supply line breakage. Figure 5: Hydrogen Storage Module GENCORE OPERATION The GenCore 5 fuel cell system is fully automated and requires no manual actions for normal operations. The controls automatically power up and enter the standby mode, once the DC power (internal or external) is applied to the system. During the standby mode, the system monitors the DC bus voltage and the output current from the internal batteries. The fuel cell system enters the running mode whenever the DC bus voltage drops below the set nominal voltage by more than 2V (adjustable) or if a significant amount of current (12A+) is drawn from the internal batteries. The control and monitoring of the fuel cell system is done via the Service Interface Software that is installed on the user s laptop or PC. A serial cable is connected to the laptop or PC s RS232 port and the RS232 port of the fuel cell system control card. The fuel cell system control card has an onboard data storage facility where it stores the last 30 days statistical data and the last 30 system events. Whenever the Service Interface Software communicates with the fuel cell system, service log files are created on the user s laptop or PC. The unit can also be connected via a modem for remote access. Figure 6 and Figure 7 show the startup screen and main window respectively for the Service Interface Software. Page 7

Figure 6: Service Interface Software Startup Screen Figure 7: Service Interface Software Main Window The fuel cell system can be manually started and shutdown from the main window shown in Figure 7. This window also displays all the operating parameters. During the running mode, the fuel cell system opens the hydrogen inlet solenoid valve and the fuel cell exports power to maintain the DC bus voltage at the nominal voltage setpoint with an offset variation. As the load current requirement changes, the fuel cell adjusts its current output to match that. The fuel cell system goes into current limit if the required load current exceeds the maximum fuel cell system output current and the internal battery will source the extra load current. During this period the battery voltage and DC bus voltage will drop as the battery discharges and the fuel cell system will shutdown if the bus voltage drops below the DC-DC converter minimum operating voltage of approximately 39Vdc. The fuel cell system will then have to be manually reset. Page 8

The control system monitors various parameters and issue alarms for low fuel conditions (where the pressure sensors are installed and feature activated), minor and major alarms. The different operating modes are indicated with a LED at the rear of the fuel cell system with different color and flashing modes to indicate the applicable operating mode. GENCORE MAINTENANCE Planned maintenance is performed on an annual basis and divided into annual maintenance and 3-yearly maintenance as indicated below. Maintenance item Yearly 3-Yearly Battery inspection X X Hydrogen safety sensor replacement X X Grounding inspection X X Hydrogen Storage Module vent inspection X X Hydrogen Storage Module inspection X X Hydrogen system leak check X X Site inspection X X Coolant replacement --- X Battery replacement --- X Cathode air filter replacement --- X Converter air filter replacement --- X GENCORE FUEL USAGE Figure 8 shows fuel consumption and run time as a function of power output. One standard hydrogen fuel cylinder will provide approximately nine-kilowatt hours of power. The Hydrogen Storage Module contains six cylinders; this amount of fuel will provide approximately 54 hours of operation at 1 kilowatt or 12 hours of operation at 5 kilowatts prior to refueling. GenCore Hydrogen Consumption 80 16.0 70 14.0 Hydrogen Use (slm) 60 50 40 30 20 10 H 2 Use Run Time [hours] 12.0 10.0 8.0 6.0 4.0 2.0 Run Time per 49.6 liter cylinder, 2400 psi (hrs) 0 0 1 2 3 4 5 Net Output Power (kw) 21 42 63 83 104 48V 42 84 126 166 208 24V 8 17 25 33 42 120V Nominal Power Level (Amps) Figure 8: Hydrogen Fuel Consumption for the GenCore 5 Fuel Cell System 0.0 Page 9