VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

Similar documents
ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

TECHNICAL SPECIFICATIONS

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

1 / Genset general description

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

1 / Genset general description

1 / Genset general description

Standby Amper VOLTAGE

Standby Amper VOLTAGE

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

16 KW / 20 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Container Powered by MTU

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Amper VOLTAGE

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

30 KW / 40 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

WPS20/S EP Series. Features:

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

18 KW / 18 KVA POWERED by

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

WPS350/S EP Series. Features:

28 KW / 28 KVA POWERED by

Technical specification

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Large autonomy Safety Ease of handling Silent. 18,0/14,4 20,0/16,0 Yanmar 4TNE88PG. 18,5/14,8 19,6/15,7 Deutz F3M 1011 F

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

80 KW / 100 KVA POWERED by

640 KW / 800 KVA POWERED by

WPS100/S EP Series. Features:

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

45 KW / 55 KVA POWERED by

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

700 KVA / 550 KW POWERED by

600 KW / 750 KVA POWERED by

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

2000 KW / 2500 KVA POWERED by

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

130 KW / 165 KVA POWERED by

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

GE.VO.360/325.SS+0_all

K26M POWER 240 MONO 230 MONO 220 MONO

1800 KW / 2250 KVA POWERED by

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

WPS60/S EP Series. Features:

Standby KW. Standby KVA G180D 230/ N/A

1000 KW / 1250 KVA POWERED by

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

WPS250/S EP Series. Features:

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

SIVASA Doosan Series. SD250 Technical Data

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Generating Rates. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

Transcription:

MODEL: ERD-100 (DEUTZ BF4M 1013 ECG2 ) 1.500 R.P.M. 50 Hz TECHNICAL SPECIFICATIONS ENGINE MAKE MODEL CONTINUOUS POWER PRP norma ISO 8528-1 DEUTZ BF4M 1013 ECG2 STAND-BY POWER LTP norma ISO 8528-1 ALTERNATOR MECC-ALTE ECP 34-2S/4 400/230 V 100 kva 110 kva VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A 415/240 50 3 0,8 105,0/84,0 110,8/88,6 154,27 400/230 50 3 0,8 105,0/84,0 110,8/88,6 160,05 380/220 50 3 0,8 105,0/84,0 110,8/88,6 168,47 240/139 50 3 0,8 105,0/84,0 110,8/88,6 266,75 230/133 50 3 0,8 105,0/84,0 110,8/88,6 278,35 220/127 50 3 0,8 105,0/84,0 110,8/88,6 291

ENGINE CHARACTERISTICS/ BF4M 1013 ECG2 GENERAL DATA POWER PRP (kwm) 91.10 POWER LTP (kwm) 96.10 No CYLINDERS 4 CYLINDERS CAPASITY (L) 4.76 DIAMETER PER STROKE (mm) 108 x 130 COMPRESSION RATIO 19 COOLING SYSTEM INJECTION SUCTION SERIES REGULATOR LIQUID direct TURBO-INTERC MECHANICAL FLY WHEEL COUPLING 2 11,5" LUBRICATION SYSTEM OIL CAPACITY (L) 11 OIL CONSUMPTION (%) 0,30 MIN. ALARM OIL PRESSURE (BAR) 2.70 VENTILATION SYSTEM AIR COOLING FLOW(m 3 /h) 6100 COMBUSTION AIR FLOW (m 3 /h) 365 ELECTRICAL SYSTEM VDC (V) 12 BATTERY (Ah) 96

ALTERNATOR CHARACTERISTICS/ ECP 34-2S/4 GENERAL DATA POWER PRP (kva) 105 POWER LTP (kva) 115.50 EFFICIENCY ALT. 3/4% 92.50 EFFICIENCY ALT. 4/4% 92.20 No POLES 4 VOLTAGE REGULATOR DSR No WIRES 12 INSULATION H Xd (%) 230 X d (%) 17.60 X 7.40 DEGREE OF PROTECTION IP21 GENERATOR SET CONSUMPTION % POWER USED LITRES / HOUR 50% 13.10 75% 19.30 100% 25.80 DIMENSIONS (MM) LENGTH WIDTH HEIGHT 2050 930 1717 CAPACITIES FUEL TANK (litres) 212 WEIGHT (kg) 1300.00 NOISE LEVEL (db (A)) 7 m 84

ERGA GENERATOR General Description ERGA generator set is an electrical energy generating machine which is used in places where there is no mains supply or when there is a MAINS failure. The mobile elements, distribution belt, fan, etc., and those parts which reach high temperatures during operation, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of the Machinery Directive 2006/42. Regulations The machine holds the CE marking, and the corresponding Declaration of Conformity is issued with each of them, in which it specifies that the machine complies with R.D 842/2002 Low Voltage Regulations and with the European Directives: 2006/42 on Safety in Machinery. 2006/95/CE on Electrical Safety. 2004/108/CE on Electromagnetic Compatibility. 2005/88/CE on NOISE EMISSIONS by equipment for outdoor use (for SOUNDPROOF GENERATOR SETS)

SCOPE OF SUPPLY INDUSTRIAL RANGE Engine/alternator monobloc directly conected and installed via silent blocks on a frame made from high tensile electro welded steel profiles that are treated with degreasing liquids and aplicated with a phosphate coat and epoxi paint Canopy of steel sheet sound proofed with fireproof rockwool, and treated with degreasing liquids and aplicated with a phosphate coat and epoxi pain Fuel tank integrated in the chassis provided with fuel level jauge and fuel lines to the engine. Open Genset Canopy Genset - Engine with mechanical engine driven pusher fan Industrial silencer with -15 db(a) noise reduction and exhaust outlet tube. - Residencial silencer with -35 db(a) noise reduction with exhaust tube and protection cap - 4 Pole termal and magnetic circuit breaker with LTS (ABB) Battery charge alternator Starter battery complete with cables to the engine and pole protection Installation prepared for earthing spike (spike not included). Security protection for blets and moving parts as well as on electrical component. External emergency stop push button Manual engine oil extraction pump Engine heater, fuel tank heater, fuel heater Control panel heater Self excited and auto regulated alternator. Integrated lifting hook for single point lifting with crane, gensets up to 450 kva (Except in swing-out cover model) - 4 Lifting points for gen sets from 450 kva and bigger. - Preparate for extended fuel tank, fully bomded for leakage protection Base frame preparated for trailer kit Standard electronic speed governor on engines from 220 kva and up Electric control cubicle with digital control module, automatic mains failure, manual start or remote start on signal. Electric engine coolant preheating on gen sets with automatic mains failure controller. Horizontal outlet for hot air -

DSE 7320 AUTOMATIC CONTROL PANEL (any of the possible modules DSE) PROTECTION, DISTRIBUTION AND AUTOMATIC CONTROL panel which starts the generator set when it detects a mains failure and stops it when the mains is restored with the control unit DSE 7320. It has a digital LCD screen, which provides easy reading of the information regarding the ENGINE, ALTERNATOR, MAINS and CHARGING. ENGINE: Coolant temperature Fuel level Operating hours Oil pressure Battery voltage Number of start-ups Turning speed (rpm) Battery alternator voltage ALTERNATOR: Voltages between phases and between phases and neutral. Intensities Reactive Power (kvar) Apparent Power (kva) Cos phi Frequency Active energy meter (kw-h) Active Power (kw) MAINS Frequency Voltages between phases and (L1-L2, L2-L3, L1-L3). Phase rotation order Voltages between phases and neutral (L1-N, L2-N, L3-N). Earth current Voltages between phases and between phases and neutral. Intensities Reactive Power (kvar) Apparent Power (kva) Cos phi Frequency Active energy meter (kw-h) Active Power (kw) PROTECTION OF THE ENGINE AND ALTERNATOR, WITH THE ALARMS ACTIVATED: ENGINE Low oil pressure Failure of the alternator to charge batteries High coolant temperature

Low fuel level Low and High battery Voltage ALTERNATOR Low and High Voltage Power Overload (KW-kVA) Low and High Frequency Load control: Overload due to Intensity (A) Connection and disconnection of artificial loads. Disconnection of non-essential loads Negative Phase Sequence. Short-circuit OTHER CHARACTERISTICS The real-time clock provides an exact record of events. Communications Ethernet, RS 232 and RS 485 Extensive number of configurable inputs and outputs. Programmer Clock with multiple maintenance events which can be configured for the optimal operation of the engine. Weekly and/or monthly programming of up to 16 starts and stops per week. Configurable alarms and timers. USB connectivity Fully configurable via software and PC. ALTERNATIVE CONFIGURATIONS, which open up the working possibilities Modbus RTU Possibility of SMS text messages