PowerSure TM Personal XT USER MANUAL 450, 700, 1250 VA 230V. English / Deutsch / Français / Italiano / Español

Similar documents
USER MANUAL English / Español

PowerSure POWER PROTECTION USER S MANUAL. Uninterruptible Power System 250 VA 600 VA 115 V PS250-60S 250 VA PS400-60S 400 VA PS600-60S 600 VA.

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

BRAVER UPS. (Uninterruptible Power System) User s Manual

Installation and Operation Back-UPS BX550CI-CN

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Item no Smart AC 200 USB. User s Manual

UTILITY INPUT MAINS OUTLET

Informer Compact Series

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

User Manual Rittal PMC UPS 6kVA

Broadband PowerShield. CP27U Models. User Manual

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Installation and Operation Manual Back-UPS BR1000-CH

Installation and Operation Manual Back-UPS BR800/1100CI-IN

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

02/15/01. Powerware User s Guide VA.

Uninterruptible Power System

Installation and Operation Manual Back-UPS BX1100CI-CN

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

USER GUIDE. PowerRite XT UPS. 400 VA, and 600 VA.

POWERWARE User s Guide VA.

Extended Battery Cabinet for Nfinity

General Precautions. Personnel Precautions

Installation Guide. Marine Filter SURT023M SURT024M

Liebert PSI XR 1000/1500/2200/3000, 120VAC. User Manual

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

Uninterruptible Power System

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

c-go 24V/6A 24V/8A 24V/12A

MM-AVR UPS Series User s Manual

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Power Inverter 400 MW Owner s Manual

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Power. On Your Terms.

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

SDU 24-BATEM. Instruction Manual. Technical Services External Battery. U.S.A... (800) International (847)

600 Amp Battery Jumper with Air Compressor

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

ITEM # V LITHIUM-ION CHARGER MODEL #KRC Español p. 6. ATTACH YOUR RECEIPT HERE Serial Number. Purchase Date

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

Series VA 230V. USER MANUAL English

Pure Sine Wave Inverter 600W-24V User Manual

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

This manual covers the following model:

WARNINGS, CAUTIONS AND NOTES

Uninterruptible Power System

10 Year Limited Warranty

Pulsar EXtreme CLA 1500C

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Remote Vehicle Control System. Keyless Entry & Remote Start System

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

A2P Single Phase Automatic Industrial Battery Charger

AC Power For Business-Critical Continuity. Liebert PSI XR. User Manual 1000/1500/2200/3000VA, 50/60Hz, 230VAC

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

BroadBand PowerShield. 20 AHr Battery. User Manual

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Back-UPS CS Back-UPS CS 350

UPStation GXT. 6 & 10 kva 208V & 240V. USER MANUAL English

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

USER MANUAL. Uninterruptible power supply MODEL: 53965,

230VAC Power Inverter 400W Owner s Manual

Operating Instructions for Your Cobra 150 Watt POWER INVERTER M ODEL CPI 150 FAULT OFF. Nothing comes close to a Cobra

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

The Power of Reliability INSTRUCTION MANUAL

BMRX Series ROTARY LEVEL CONTROL

Liebert GXT MT+ User Manual VA Installer/User Guide

USER MANUAL MPS 1-5KW SERIES

Powerware Vdc Extended Battery Cabinet User s Guide.

400 Watt Backup Power System Owner s Manual

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Operating Instructions & Parts Manual. 100 Watt Power Inverter. Model 54DC41A

Remote Vehicle Control System. Keyless Entry and Convenience System

CYCLONE DR Bolt PP-400BP Battery Pack for PP-400DR Portable Power Pack

Owner's Manual. For latest instructions please go to

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

INSTALLATION & OWNER'S MANUAL

Go Power! Manual. GP-Smart Charger

i n s t r u c t i o n m a n u a l

Owner's Manual. For latest instructions please go to

SLA Battery Capacity Analyzer

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Transcription:

PowerSure TM Personal XT 450, 700, 1250 VA 230V USER MANUAL English / Deutsch / Français / Italiano / Español

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of the UPS and its batteries. Please read this manual thoroughly before attempting to install or operate this UPS. This equipment can be installed and operated by individuals without previous training. 1. PowerSure Personal XT models are available for 230VAC supply voltages and loads. Please verify that this model matches your AC mains/ load voltage requirements. 2. This equipment is designed for Commercial/Industrial use only. Liebert Corporation neither recommends nor knowingly sells this product for use in critical life support applications. 3. The PowerSure Personal XT 230VAC models are not supplied with an input power lead for connection to the mains supply. Use the input mains power lead from your data processing equipment to connect the UPS to the mains supply. The UPS is supplied with two output power leads with moulded connectors to connect from the UPS output to your equipment. Additional input/output leads can be obtained from your dealer. Also provided is a Liebert special interconnection cable for connection to DB9 connector on the rear of the UPS for use with Liebert's SiteNet MultiLink software (see user manual for details) DO NOT USE FOR OTHER APPLICATIONS. Store in safe place if not required at this time. 4. This UPS must be earthed at all times during operation. Connect only to a mains supply socket outlet with an earth connection. A means of disconnection of the mains supply should be within 2 metres of the UPS. 5. WARNING: Output receptacles on the UPS are electrically live if the UPS is switched ON, even if the UPS is not plugged in to a mains supply. The. On/Off button on the UPS does not electrically isolate the internal parts. To isolate the UPS, switch OFF the UPS first, then unplug it from the mains. To reduce the risk of electric shock, do not remove the cover, as it has no user-serviceable parts inside. Some components are live, even when AC. power is disconnected. For service, contact a qualified technician. To reduce the risk of fire, use the proper rating when replacing the fuse. To prevent the risk of fire or electric shock, install the UPS in a temperature and humidity controlled room, free of conductive contaminants. 6. Your total load earth leakage current must not exceed 3.5 milli-amperes. Most data processing equipment meets this requirement if you use no more than 2 pieces of equipment. For further advice contact your dealer. 7. The UPS relies on your building wiring overcurrent protection, which must be rated between 10-20 amperes. 8. When using the communication features on the UPS, ensure the cabling connected to the DB9 communication port or the network connection are kept separated by 25mm from the power leads to the UPS input and output. 2

These units bear TUV GS mark, CE mark and comply with the following standards (limits value class B): EN 60950 (1998.8), EN 50091-1 (1994.4), EMI/RFI: EN550222 class B EMS: IEC 1000-4-2 (ESD) Level 3 IEC 1000-4-3 (RS) Level 3 IEC 1000-4-4 (EFT) Level 3 IEC 1000-4-5 (Lightning surge) Level 3 CAUTION: Although your UPS has been designed and manufactured to assure personal safety,. improper use can result in electrical shock or fire. To insure safety, please observe the following rules: Turn off and unplug your UPS before cleaning. Do not use liquid or aerosol cleaners. A dry cloth is recommended to remove dust from the surface of your UPS. Do not install or operate your UPS in or near water. Do not place UPS on an unstable cart, stand, or table. Do not place UPS under direct sunlight or close to heat emitting sources.. Do not place UPS power cord in any area where it may get damaged by heavy objects. Follow all warnings and instructions marked on the UPS. Do not attempt to service the UPS, as it has no user-serviceable parts inside. Refer all repairs to qualified service personnel. ATTENTION: Turn off and unplug your UPS from the outlet and contact qualified service personnel if: The power cord or plug is damaged.. Liquid has been spilled on the UPS. The fuse blows frequently. The UPS does not operate even when user follows the operating instructions. CONDITIONS OF USE: Your UPS provides conditioned power to connected equipment. Maximum load must not exceed that shown on UPS rating label. If uncertain, consult your distributor or Liebert. Placing magnetic storage media on top of the UPS may result in data corruption. 3

INTRODUCTION & SYSTEM DESCRIPTION Congratulations on your choice of the Liebert PowerSure Personal XT Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. MAJOR COMPONENTS PowerSure On/Off! Status-LED Fault-LED Output Receptacles MODEL:YUNTO Q700 IMPUT:230V~,50/60Hz, 4.0A, 1Ø OUTPUT:230V~,50/60Hz, 700VA/420W, 3.1A MADE IN CHINA Lead-acid battery inside the enclosure Blei-Akkumulator innerhalb des Gehause INPUT FUSE:250V~,5A,T RS232 OUTPUT FRONT BACK 4

GENERAL INSTALLATION PowerSure! PowerSure! Remove from Box Check for Damage PowerSure! 110 mm 0-40 C MODEL:YUNTO Q700 IMPUT:230V~,50/60Hz, 4.0A, 1Ø OUTPUT:230V~,50/60Hz, 700VA/420W, 3.1A MADE IN CHINA Lead-acid battery inside the enclosure Blei-Akkumulator innerhalb des Gehause INPUT FUSE:250V~,5A,T RS232 OUTPUT Remove Plug from Units and replace in UPS PowerSure MODEL:YUNTO Q700 IMPUT:230V~,50/60Hz, 4.0A, 1Ø OUTPUT:230V~,50/60Hz, 700VA/420W, 3.1A MADE IN CHINA Lead-acid battery inside the enclosure Blei-Akkumulator innerhalb des Gehause INPUT FUSE:250V~,5A,T RS232! OUTPUT Plug Units(s) into UPS Press ON Button 5

NORMAL MODE OPERATION 1. Inspect the packaging carton and its contents for damage. Please inform the trasport agency immediately should you find signs of damage. Please keep the packaging in a safe for future use. 2. Plug the UPS into a wall outlet (see figure 1). Let the UPS charge the battery for at least 2 hours. You may use the UPS while the battery charges, but the UPS backup time will be reduced until the battery is fully charged. It will take up to 8 hours to charge the fully discharged battery 3. To start up the UPS, press the On/Off switch. When the UPS start, it will beep an both LEDs of the front panel will light up for 2 seconds. The green light up continuously. This indicates normal operation. Note: If the UPS continues to beeps, or the green light is not alight even mains power is available, please see the chapter Troubleshooting for more information. 4. Switch off the equipment you want to protect, and connect it to the outlets of the UPS. 5. Switch on the protected equipment, one piece per time. BATTERY MODE OPERATION Battery mode occurs in event of extreme input mains conditions or a complete mains failure. During Battery mode the Mains / Battery LED (green) will flash every 4 seconds and an alarm will sound every 4 seconds. This will change to a beep every second when the battery runs low (approximately 2 minutes remaining). WARNING: Turning off the UPS while in Battery mode will result in loss of output power. 6

LED & ALARMS The front panel LEDs and audio beeps indicate the UPS status. Switch and LEDs Symbol Function On/off Turn the UPS system an and off. 1. Steady: Input power is acceptable; the UPS is in normal mode (online) Status-LED (green) 2. Blinking: Input power is out of tolerance; the UPS is battery mode. Fault-LED (red)! 3. Off: No input power or the battery is exhausted or the UPS is switched off. 1. Blinking: The UPS is overloaded or has failed at battery test. 2. Steady: UPS fault. Switch and LEDs Beep continuously for 2 sec. Starting up the UPS. Function 1 beep every 4 sec. Power failure: UPS is battery mode. 1 beep every sec. Battery low: UPS is in battery mode, batteries are nearly axhausted, and UPS will be shut down. 1 beep every 2 sec. Battery weak: UPS is normal mode (online), battery is not fully charged, backup time during power failure shorter than nominal value. 3 beep every 2 sec. Battery replacement: battery needs to be replaced. 2 beep every 2 sec. Charger fault: UPS cannot recharge the battery. See chapter Troubleshooting for more information. 1 beep every half Overload. See chapter Troubleshooting for more information. sec. Continuous Fault: please contact your dealer. 7

TROUBLESHOOTING If the UPS fails to operate properly, turn off the unit and repeat the steps in the installation section of this manual. If the problem persists, refer to the chart below: PROBLEM POSSIBLE CAUSE REMEDY No indication, no Check building wall outlet and mains cable by beep even UPS is No input voltage connecting another device with cable to this wall connected to mains outlet power supply Fuse has been melt Replace fuse by fuse with same rating Green LED blinks, Mains power failure Wait until mains power recovers red LED off, UPS input power cord Make sure the power cord is connected 1 beep every 4 sec. not plugged in Power cord defective Please contact your dealer Plug the UPS into a working wall outlet for at least Grenn LED blinks, very low battery voltage 8 hours to recharge the batteries. If the problem red LED off, still rmains, the UPS will not operate during 1 beep every sec. power failure, or it will turn off immediately. In this case, contact your dealer Grenn LED lights up, red LED blinks, Battery cannot be charged Please contact your dealer 2 beep every 2 sec. Grenn LED lights up, red LED blinks, The power required from Remove equipment until the UPS stops beeping 1 beep every half- the equipments is too high sec. Green LED off, Output short circuit Remove alla off the equipments and contact your dealer red LED lights up, Overload exceeds 120% Reduce the load continuous beeps UPS fault Contact your dealer 8

COMMUNICATIONS You can use MultiLink Software to allow your UPS to communicate to your computer via your DB-9 communications port. A MultiLink Software CD is included in the box, or you can download it from our web site at www.liebert.com. The PowerSure Personal XT UPS contains a standard DB-9 receptacle located on the rear of the UPS unit. Several signals are provided on this port and are assigned as follows: PIN ASSIGNMENT DESCRIPTION 1 Low Battery (open collector) 2 No connection 3No connection 4 Remote Shutdown (5-12V); on battery operation 5 Common 6 Remote Shutdown (short to pin5); any mode operation 7 Low Battery (open emitter) 8 AC Fail (open emitter) 9 AC Fail (open collector) PIN Assigment 6 7 8 9 1 2 3 4 5 The DB-9 communication port allows: the status of UPS to be monitored, data to be backed up, computer to be switched off MAINTENANCE The PowerSure Personal XT UPS requires very little maintenance. The batteries are valve regulated, nonspillable, lead acid, and require that they be kept charged to obtain their designed life. When connected to the mains supply, the battery is continuously charged. When storing the UPS for any length of time, it is recommended to plug in the UPS for at least 24 hours every four to six months to ensure full recharge of the batteries. Battery disposal - When the battery life is expended (see alarm indications), dispose of the discarded batteries in accordance with local environmental laws. 9

230V SPECIFICATIONS ELECTRICAL SPECIFICATION Model Number PSPXT450-230 PSPXT700-230 PSPXT1250-230 INPUT Voltage 230 VAC (197-262 VAC) Frequency 50 Hz ± 4Hz; 60 Hz ± 4Hz Amperage (maximum) 2.6 A 4.0 A 7.0 A Phase 12 φ 2W, Ground OUTPUT Power rating 450 VA - 270 W 700 VA - 420 W 1250 VA - 750 W Voltage 230 VAC ± 10% Frequency 50 Hz ± 1Hz; 60 Hz ± 1Hz Wave form STEP Line mode 105%, 130% load, 3 minutes to fault Overload protection Line mode > 130% load, 7s to fault Battery mode 105%, 120% load, 20s to shutdown Battery mode > 120% load, 5s to shutdown BATTERY PARAMETERS Model Number PSPXT450-230 PSPXT700-230 PSPXT1250-230 Type Valve-regulated, nonspillable, lead acid Quantity x Voltage x (1) x 12V x 7 Ah (1) x 12V x 9 Ah (2) x 12V x 7 Ah Rating Approved Battery CSB, Panasonic, BB Battery and Yuasa Manufacturers: Transfer Time 2-6 ms typical Operating Back-up time >10 minutes Recharge time 8hr up to 90% DIMENSION AND WEIGHTS Dimensions wxhxd (mm) 80*176,5*233 80*176,5*233 92*238*283 Net Weight, Kg 3.5 3.6 6.5 Gros Weight, Kg 4.5 4.6 7.9 OPERATING ENVIRONMENT Operation temperature: 0 C to 40 C Storage Temperature: -15 C to 40 C Operation humidity: 20% to 90% 10

LIMITED WARRANTY Liebert Corporation extends the following LIMITED WARRANTY to the purchaser and to its customer (collectively referred to as the "Purchaser"): the enclosed Uninterruptible Power System (UPS) and components are free from defects in materials and workmanship under normal use, service, and maintenance FOR A PERIOD OF TWO YEARS FROM THE DATE OF ORIGINAL PURCHASE from Liebert or the Liebert dealer or retailer. THE FOREGOING WARRANTY IS THE ONLY WARRANTY GIVEN AND NO OTHER WARANTY IS PROVIDED, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Certain aspects of disclaimers are not applicable to consumer products acquired by individuals and used for personal, family, or household purposes (as distinguished from industrial or other purposes). Local laws may not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary according to local law. Certain repairs or services are the responsibility of the Purchaser and the Purchaser is expected to pay for them. This warranty does not extend either to products with removed or altered serial numbers or to any losses or damages due to act of God or source external to the product, misuse, accident, abuse, neglect, negligence, unauthorized modification, alteration, or repair, use beyond rated capacity, or improper installation, maintenance, application or use, including, without limitation, use in a manner contrary to the accompanying instructions or applicable codes. WARNING: Warranty is void if the battery is allowed to discharge below the minimum battery cutoff point. To prevent such discharge DO NOT leave the unit power switch "ON" for more than two (2) days without AC power being supplied to the UPS. The battery must be recharged every four (4) to six (6) months when not in use. If the UPS fails to conform with the above warranty within the two year warranty period, Liebert will repair or replace the UPS, at Liebert's option. Repairs or replacements are warranted for the remainder of the original warranty period. To make a warranty claim, purchaser should call a Liebert Representative to obtain a Returned Goods Authorization number and shipping instructions. Return transportation costs to Liebert are the responsibility of the Purchaser. "LIFE SUPPORT" APPLICATIONS Due to the diversity of applications and considerations to be applied in each case, Liebert does not recommend or knowingly sells its products for such use. The responsibility for risk assessment and management in applications where the malfunction or failure of the UPS could be reasonably expected to give rise to a risk of human life shall be the sole responsibility of the purchaser. Liebert accepts no liability for consequential harm in such applications. 11

PowerSure TM Personal XT 450, 700, 1250 VA 230V Technical Support U.S.A. 1-800-222-5877 Outside the U.S.A. 614-841-6755 U.K. +44 (0) 1793 553355 France +33 (0) 1 43 60 01 77 Germany +49 89 99 19 220 Italy +39 02 98250 1 Netherlands +31 (0) 475 503333 E-mail upstech@liebert.com Web site http://www.liebert.com Worldwide FAX tech support +614-841-5471 The Company Behind The Products With more than 1.000.000 installations around the globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a complete range of support and protection systems for sensitive electronics: Environmental systems: close-control air conditioning from 1.5 to 60 tons. Power conditioning and UPS with power ranges from 250 VA to more than 1000 kva. Integrated systems that provide both environmental and power protection in a single, flexible package. Monitoring and control - on-site or remote - from systems of any size or location Service and support, through more than 100 service centers around the world, and a 24- hour Customer Response Center. While every precaution has been taken to ensure accuracy and completeness of this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 1999 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SLI-23265 (5/99) Rev. 0 12