ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

Similar documents
Installation Couplers intended for permanent connection in fixed installation

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Amendment to Test Report

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

AS/NZS AS/NZS

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Installation Couplers intended for permanent connection in fixed installation

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Amendment to Test Report

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT EN LED modules for general lighting Safety specifications

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

TEST REPORT IEC Connectors Safety requirements and tests

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V

LIA Laboratories Limited

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

Page 3 of 32 Report No Summary of testing:

Page 3 of 34 Report No Part I

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Intertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc.

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

TEST REPORT IEC LED modules for general lighting Safety specifications

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

LIA Laboratories Limited

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LIA Laboratories Limited

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

Miniature Circuit Breaker

Page 2 of 39 Report No. CTI PA Testing location:

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires

COVER PAGE FOR TEST REPORT

Test Report issued under the responsibility of: Report Reference No... : AS9-7 Date of issue... : Total number of pages...

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

< > Page 2 of 84

DX³ 4-pole RCBO 6000 A/10 ka

Presented to the IAPMO Standards Review Committee on December 9, 2013

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans


LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Test Report issued under the responsibility of:

Test Report issued under the responsibility of:

AGREEMENT. (Revision 2, including the amendments entered into force on 16 October 1995) Addendum 102: Regulation No. 103

Ref No: Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2

045 : 2000 CEB STANDARD

RX 3 M.C.B A up to 63 A

This document is a preview generated by EVS

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

3 - Protection components Motor circuit-breakers

Test Report issued under the responsibility of: Report Number...:

RX 3 M.C.B A up to 63 A

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT. IEC 62133: 2012 (Second Edition)

MS General Information Extended Product Type: MS

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

COVER PAGE FOR TEST REPORT

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

NCB Intertek Testing Services NA, Inc.

DPX earth leakage DPX 3 -I earth leakage

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

Part 1: General requirements for basic safety and essential performance

DRX 250 B/N/H Circuit breaker (not adjustable)

NPS/001/017 Technical Specification for Low Voltage and High Voltage Current Limiting Fuse Links

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

SEM.Test Compliance Service Co., Ltd

Page 2 of 23 UNT150420C11

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

Phase + Neutral, neutral on right side

ATX DPD Series Distribution Panelboards Flameproof

SOUTH AFRICAN NATIONAL STANDARD

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

SHA-001 Date of issue...: Total number of pages Report Reference No...:

(1,5 modules per pole)

Transcription:

Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report Number... : 3309514.50 Date of issue... : 2016-04-18 Total number of pages... 23 Applicant s name... : ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : NO. 299 EAST CHANGHONG ROAD, DEQING ECONOMIC ZONE, WUKANG, DEQING, ZHEJIANG, CHINA.C: 313200 Test specification: Standard... : IEC 60898-1 (Second Edition) Test procedure... : Type Test Non-standard test method... : Test Report Form No.... : IEC60898_1D Test Report Form(s) Originator... : DEKRA Certification B.V. Master TRF... : Dated 2015-09 Test item description... : Circuit-breakers for overcurrent protection Trade Mark... : MAXGE Manufacturer... : ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. NO. 299 EAST CHANGHONG ROAD, DEQING ECONOMIC ZONE, WUKANG, DEQING, ZHEJIANG, CHINA.C: 313200 Model/Type reference... : SGBi, ALBi6K, ALB6K Ratings... : 1, 2, 3, 4 Ue: 240 / 415 Vac for 1, 415 V for 2, 3, 4 In: 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 A B and C type, 50 / 60 Hz Ics = Icn = Icn1 = 6000 A Energy limiting class 3: B and C type of 4 A to 32 A Energy limiting class 1: B and C type of 40 A to 63 A

age 2 of 23 Responsible Testing Laboratory (as applicable), testing procedure and testing location(s): Testing Laboratory: DEKRA Testing Services (Zhejiang) Co., Ltd. Testing location/ address...: No.5, Changjiang Road, Great Bridge Industrial ark, North Baixiang, Wenzhou, Zhejiang, 325603,.R. China Associated CB Testing Laboratory: Testing location/ address...: Tested by (name, function, signature)...: Ray Zhu Approved by (name, function, signature)...: Lester Wang Testing procedure: CTF Stage 1: Testing location/ address...: Tested by (name, function, signature)...: Approved by (name, function, signature)...: Testing procedure: CTF Stage 2: Testing location/ address...: Tested by (name + signature)...: Witnessed by (name, function, signature)..: Approved by (name, function, signature)...: Testing procedure: CTF Stage 3: Testing procedure: CTF Stage 4: Testing location/ address...: Tested by (name, function, signature)...: Witnessed by (name, function, signature)..: Approved by (name, function, signature)...: Supervised by (name, function, signature) :

age 3 of 23 Summary of testing: The following samples were chosen for the type test according to annex C of IEC/EN 60898-1 in consideration of Intertek CB test report: Tests performed (name of test and test clause): No. Type reference Current Number of poles Type Voltage Test sequence 7# SGBi 63 A 1 C 240 / 415 Vac 8# SGBi 32 A 4 B 415 Vac A1 (only clause 6) 1#-3# ALB6K 63 A 2 C 415 Vac 4#-6# ALBi6K 63 A 4 C 415 Vac E1 Notes: 1. This report is based on and shall be read in conjunction with Intertek CB certificate No. SE-81849 issued on 2016-01-19 with test SH150801332SHA-001, 002, 003, 004 issued on 2015-1228. 2. The type reference ALB6K and ALBi6K are same with SGBi except the shape of cover, all tests were performed on SGBi in Intertek CB test reports, sequence E1 was performed on maximum current of ALB6K and ALBi6K with 2 and 4 respectively to verify the compliance. Testing location: All tests were conducted in: DEKRA Testing Services (Zhejiang) Co., Ltd. No.5, Changjiang Road, Great Bridge Industrial ark, North Baixiang, Wenzhou, Zhejiang, 325603,.R. China Summary of compliance with National Differences (List of countries addressed): The product fulfils the requirements of EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012, the results are laid down in Annex 1 of this report.

age 4 of 23 Copy of marking plate: Marking for 1 circuit-breaker Marking for 4 circuit-breaker

age 5 of 23 Copy of marking plate: Marking for 4 circuit-breaker Marking for 4 circuit-breaker Note: The markings for circuit breakers are same except the type reference, the rated current, the tripping characteristic type, and the number of poles.

age 6 of 23 Classification of installation and use...: fixed Supply Connection...: single phase or 3 phases system ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) Testing... : Date of receipt of test item... : 2016-01 Date (s) of performance of tests... : 2016-02 - 2016-04 General remarks: "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Manufacturer s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided...: Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies)... : ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. NO. 299 EAST CHANGHONG ROAD, DEQING ECONOMIC ZONE, WUKANG, DEQING, ZHEJIANG, CHINA.C: 313200 General product information: The technical data of the MCB are listed on page 7 of this report. The grid distance a : 45 mm.

age 7 of 23 Circuit-breakers for overcurrent protection Test item particulars... Type of circuit-breaker... : SGBi, ALBi6K, ALB6K Number of poles... : 1-3- rotection against external influences... : enclosed unenclosed Method of mounting... : surface flush Method of connection... :.not associated with the mechanical mounting associated with the mechanical mounting Type of terminal... : Instantaneous tripping current... : 2 I t characteristic...: Value of rated operational voltage (Ue)... : Value of rated current (In)... : 1-+N 3-+N a) b) 2-4- panel board a) b) screw pillar screw lessa) plug-in a) copper conductors b) aluminium conductors B C a) b) cage flat quick connect a) screw-in D Energy limiting class 3: B and C type of 4 A to 32 A, Energy limiting class 1: B and C type of 40 A to 63 A according to EN 60898-1 120 V 230 V 240 V 120/240 V 230/400 V 400 V 240/415 V for 1 circuit-breaker 415 V for 2, 3, 4 circuit-breakers 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 A Value of rated frequency... : 50 Hz 60 Hz Ambient air temperature ( C)... : 30 C 40 C Rated short-circuit capacity (Icn)... : 1,5 ka 10 ka 3 ka 15 ka 4,5 ka 20 ka Rated impulse withstand voltage (Uimp) 2,5 kv 4 kv declared kv lug Other C 6 ka 25 ka

age 8 of 23 IEC 60898-1 Clause Requirement + Test Result - Remark TESTS A1 1 sample #7: SGBi, C63, 1 Verdict SH150801332SHA-001except clause 6 6 MARKING AND OTHER INFORMATION Circuit-breaker marked with: a) Manufacturer s name or trade mark...: MAXGE b) Type designation, catalogue number or other SGBi serial number...: c) Rated voltage (V)...: 240 / 415 V~ d) Rated current without symbol "A", preceded C63 by the symbol of instantaneous tripping...: e) Rated frequency (Hz)...: f) Rated short circuit capacity (A)...: 6000 in a rectangle g) Wiring diagram h) Ambient air temperature, if different from 30 C i) Degree of protection, if different from I20 j) For D-type circuit-breakers: the maximum instantaneous tripping current, if higher than 20 In see table 2) k) Rated impulse withstand voltage Uimp if it is 2,5 kv l) Making and breaking capacity on an individual protected pole of multipole circuit-breakers (Icn1), if different from Icn Marking d) shall be readily visible when the CB is installed If, for small devices, the available space is insufficient, markings a), b), c), e), f), h), j) and l) may be put on the side or on the back of the CB Marking g) may be on the inside of any cover which has to be removed in order to connect the supply wires but shall not be on a label loosely attached to the CB Any other information not marked shall be given in the manufacturer s documentation The suitability for isolation, which is provided by all circuit-breakers of this standard, may be indicated by the symbol on the device I2t characteristic (documentation)

age 9 of 23 IEC 60898-1 Clause Requirement + Test Result - Remark Verdict Symbols on supply and load terminal Terminal for neutral conductor N Earthing terminal if any (IEC 60417-5019) On - off position shall be clearly indicated - 0 I - For push-button CB the off push-button shall either be red or be marked with the symbol 0 Red not used for other push-button For CB with multiple current ratings, the maximum value is marked, the adjusted value indicated without ambiguity TESTS A1 1 sample #8: SGBi, B32, 4 SH150801332SHA-004 except clause 6 6 MARKING AND OTHER INFORMATION Circuit-breaker marked with: a) Manufacturer s name or trade mark...: MAXGE b) Type designation, catalogue number or other SGBi serial number...: c) Rated voltage (V)...: 415 V~ d) Rated current without symbol "A", preceded B32 by the symbol of instantaneous tripping...: e) Rated frequency (Hz)...: f) Rated short circuit capacity (A)...: 6000 in a rectangle g) Wiring diagram h) Ambient air temperature, if different from 30 C i) Degree of protection, if different from I20 j) For D-type circuit-breakers: the maximum instantaneous tripping current, if higher than 20 In see table 2) k) Rated impulse withstand voltage Uimp if it is 2,5 kv l) Making and breaking capacity on an individual protected pole of multipole circuit-breakers (Icn1), if different from Icn Marking d) shall be readily visible when the CB is installed

age 10 of 23 IEC 60898-1 Clause Requirement + Test Result - Remark Verdict If, for small devices, the available space is insufficient, markings a), b), c), e), f), h), j) and l) may be put on the side or on the back of the CB Marking g) may be on the inside of any cover which has to be removed in order to connect the supply wires but shall not be on a label loosely attached to the CB Any other information not marked shall be given in the manufacturer s documentation The suitability for isolation, which is provided by all circuit-breakers of this standard, may be indicated by the symbol on the device I2t characteristic (documentation) Symbols on supply and load terminal Terminal for neutral conductor N Earthing terminal if any (IEC 60417-5019) On - off position shall be clearly indicated - 0 I - For push-button CB the off push-button shall either be red or be marked with the symbol 0 Red not used for other push-button For CB with multiple current ratings, the maximum value is marked, the adjusted value indicated without ambiguity TESTS A2 SH150801332SHA-001, 002, 004 TESTS B SH150801332SHA-001, 004 TESTS C SH150801332SHA-001, 002, 004 TESTS D SH150801332SHA-001, 004

age 11 of 23 IEC 60898-1 Clause Requirement + Test Result - Remark TESTS E1 SH150801332SHA-001, 002, 004 and result in this report TESTS E1 3 samples ALB6K, C63, 2 1# 9.12.11.4. 2 9.12.9.2 9.12.9.3 2# -3# Test E1: Test at service short-circuit capacity Service short-circuit capacity (Ics)...: 6000 A Test circuit: figure...: Figure 3 Test voltage 1,1 Un 437,3 V rospective current...: 6000 A rospective current obtained...: 6030 A ower factor...: 0,65-0,70 ower factor obtained...: 0,67 Sequence...: O - O - CO T (min)...: 3 min Test in free air copper wire F : resistor R : a = 45 mm 0,12 mm / 0,75 Ohm / Test in enclosures copper wire F : 0,12 mm / resistor R : 0,75 Ohm / 0,16 mm 1,5 Ohm 0,16 mm 1,5 Ohm Ieak (A) max. value...: 2 Max. I²t (ka s) L1/L2 9.12.12.1 Verdict 1# 2# 3# 4,4 ka 4,2 ka 4,4 ka 1# 2# 3# 56,9 ka2s 58,6 ka2s 53,4 ka2s - No permanent arcing - No flash-over between poles or between poles and frame - No blowing of the fuses F and F - olyethylene foil shows no holes After the test: The circuit-breakers shall show no damage impairing their further use and shall maintenance, withstand the following tests.

age 12 of 23 IEC 60898-1 Clause Requirement + Test Result - Remark a) leakage current across open contacts, according to 9.7.5.3, each pole is supplied at a voltage 1,1 times Un.= V. The circuit breaker is in the open position 457 V The leakage current shall not exceed 2 ma L1 L2 Verdict 1# 2# 3# 13 µa 44 µa 5 µa 5 µa 5 µa 22 µa Electric strength test: Test voltage 1500 V (see 9.7.2) 1500 V a) b) c) d) e) 2000 V Test current 0.85x non-tripping current (1,13 IN ) 60,5 A - assed for 1h - assed for 2h Current is then steadily increased to 1,1 x tripping current (1,45 IN ) within 5s Tripping within 1 hour / 2 hour 100,5 A 2# 3# 87 s 112 s 73 s ALBi6K, C63, 4 4# 9.12.9.2 1# TESTS E1 3 samples 9.12.11.4. 2 5# -6# Test E1: Test at service short-circuit capacity Service short-circuit capacity (Ics)...: 6000 A Test circuit: figure...: Figure 3 Test voltage 1,1 Un 436,3 V rospective current...: 6000 A rospective current obtained...: 6044 A ower factor...: 0,65-0,70 ower factor obtained...: 0,67 Sequence...: O - CO - CO T (min)...: 3 min Test in free air copper wire F : resistor R : a = 45 mm 0,12 mm / 0,75 Ohm / 0,16 mm 1,5 Ohm

age 13 of 23 IEC 60898-1 Clause Requirement + Test 9.12.9.3 Test in enclosures copper wire F : 0,12 mm / resistor R : 0,75 Ohm / Result - Remark Verdict 0,16 mm 1,5 Ohm Ieak (A) max. value...: L1 L2 L3 L4 2 Max. I²t (ka s) L1 L2 L3 4# 5# 6# 4,5 ka 5,3 ka 4,4 ka 5,2 ka 4,7 ka 4,7 ka 3,8 ka 4,2 ka 5,1 ka 4# 5# 6# 63,6 2 ka s 91,7 ka2s 48,5 ka2s 81,4 2 ka s 86,6 ka2s 61,8 ka2s 48,6 2 ka s 56,5 ka2s 97,0 ka2s L4 9.12.12.1 - No permanent arcing - No flash-over between poles or between poles and frame - No blowing of the fuses F and F - olyethylene foil shows no holes After the test: The circuit-breakers shall show no damage impairing their further use and shall maintenance, withstand the following tests. a) leakage current across open contacts, according to 9.7.5.3, each pole is supplied at a voltage 1,1 times Un.= V. The circuit breaker is in the open position The leakage current shall not exceed 2 ma L1 L2 L3 L4 457 V 4# 5# 6# 20 µa 81 µa 5 µa 5 µa 45 µa 5 µa 76 µa 5 µa 34 µa 5 µa 5 µa 5 µa Electric strength test: Test voltage 1500 V (see 9.7.2) 1500 V a) b) c) d)

age 14 of 23 IEC 60898-1 Clause Requirement + Test Result - Remark Verdict e) 2000 V Test current 0.85x non-tripping current (1,13 IN ) 60,5 A - assed for 1h - assed for 2h Current is then steadily increased to 1,1 x tripping current (1,45 IN ) within 5s Tripping within 1 hour / 2 hour 100,5 A 4# 5# 6# 56 s 47 s 73 s TESTS E2 TESTS E3 Annex E Annex J Annex K Annex L

age 15 of 23 IEC60898_1D - ATTACHMENT Clause Requirement + Test Result - Remark Verdict Annex 1 ATTACHMENT TO TEST REORT IEC 60898-1 EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Differences according to... : EN 60898-1:2003+A1:2004+A11:2005+A12:2008+A13:2012 Attachment Form No... : EU_GD_IEC60898_1C Attachment Originator... : DEKRA Master Attachment... : 2014-03 Copyright 2014 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. CENELEC COMMON MODIFICATIONS (EN) Test item particulars... Circuit-breakers for overcurrent protection Type of circuit-breaker...: SGBi, ALBi6K, ALB6K Energy limiting class...: Class 1 for B and C type 40 A to 63 A circuit breakers Class 3 for B and C type 4 A to 32 A circuit breakers Value of rated operational voltage (Ue)...: 230 V 240 V 230 / 400 V 400 V 240 / 415 V for 1 circuit-breaker 415 V for 2, 3 and 4 circuit-breakers Rated impulse withstand voltage (Uimp) 4 kv Requirements for construction and operation SH150801332SHA-001, 004 GENERAL SH150801332SHA-001, 004 TESTS A 6 MARKING AND OTHER INFORMATION 6.1 Standard marking: 6000 in a rectangle f) Rated short circuit capacity in A within a rectangle, without symbol A... h) calibration temperature, if different from 30 C j) Energy limiting class in a square in accordance 1 for 40 A to 63 A circuit with annex ZA. breakers 3 for 4 A to 32 A circuit breakers

age 16 of 23 IEC60898_1D - ATTACHMENT Clause 6.2 6.3 Requirement + Test Result - Remark Verdict k) Making and breaking capacity on an individual Icn1 = Icn = 6000 A protected pole of multipole circuit-breakers (Icn1), if different from Icn Additional marking Additional marking to other standards (EN or IEC or other) is allowed under the follow conditions: - the circuit-breaker shall comply with all the requirements of the additional standard; - the relevant standard to which the additional marking refers shall be indicated adjacent to this marking and shall be clearly differentiated or separated from the standard marking according to cl. 6.1 Compliance is checked by inspection and by carrying out all the test sequences required by the relevant standard. Equivalent or less severe test sequences need not be repeated. Guidance table for marking Each MCB shall be marked in a durable manner with all or, for small apparatus, according table for marking TESTS C 9.12.11.2. Test C2 :Short-circuit test on circuit-breakers 2 for use in IT systems TESTS D TESTS E3 SH150801332SHA-001, 002, 004 SH150801332SHA-001, 002, 004 SH150801332SHA-001, 004

age 17 of 23 IEC60898_1D - ATTACHMENT Clause Requirement + Test Result - Remark Verdict Annex ZC (normative) EN 60898-1 Special national conditions For the countries in which the relevant special national conditions apply these provisions are normative, for other countries they are informative. Austria, Czech Republic, Denmark, Netherlands, Norway and Switzerland The upper limit of current for use of screw less terminals is 16 A - K1 Austria, Belgium, Denmark, France, Germany, Italy, ortugal, Spain, Sweden, Switzerland, and United Kingdom Only universal screwless type terminals are accepted. Belgium, France, Italy, ortugal, Spain, and United Kingdom K.8.2.2 The use of circuit-breakers with flat quick-connect terminations for rated currents up to and including 20 A is accepted. Belgium, France, Italy, ortugal, Spain, and United Kingdom J.1 J.3.3 The use for rated currents up to and including 20 A - -

age 18 of 23 hotographs SGBi, Front view, 4 SGBi, Side view, 4

age 19 of 23 SGBi, Side view, 4 SGBi, Internal view, 4

age 20 of 23 ALBi6K, Front view, 4 ALBi6K, Side view, 4

age 21 of 23 ALBi6K, Side view, 4 ALBi6K, Internal view, 4

age 22 of 23 ALB6K, Front view, 4 ALB6K, Side view, 4

age 23 of 23 ALB6K, Side view, 4 ALB6K, Internal view, 4