Fisher 377 Trip Valve

Similar documents
Fisher 377 Trip Valve

Fisher VBL Volume Booster

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Fisher VBL Volume Booster

Fisher 685 Piston Actuator

Fisher 657 and 667 Diaphragm Actuators

Fisher 2052 Diaphragm Rotary Actuator

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

Fisher 685SE and 685SR Piston Actuators

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Fisher 377 Trip Valve

Fisher 2052 Diaphragm Rotary Actuator

Fisher 3024C Diaphragm Actuator

Type 1051 and 1052 Diaphragm Rotary Actuators

Fisherr 1051 and 1052 Diaphragm Rotary Actuators

Baumann Sanitary Angle Control Valve

Fisher 656 Diaphragm Actuator

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Fisher A31A Cryogenic High Performance Butterfly Valve

Fisher eplug complete Rotary Control Valve and Actuator Package

Fisher V250 Rotary Control Valve

Fisher 1077 Manual Handwheel Rotary Actuator

Fisher 480 Series Yokeless Piston Actuators

Fisher 2506 and 2516 Receiver Controllers

Baumann Corrosion Resistant Control Valve

Fisher 9500 Butterfly Control Valve

Fisher SS-263 Volume Booster

Fisher SS-138B Continuous Catalytic Regeneration Valve

Fisher SS-252B Continuous Catalytic Regeneration Valve

Fisher 2052 Diaphragm Rotary Actuator

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisherr 2052 Diaphragm Rotary Actuator

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Fisher 685 Piston Actuator

Fisher V500 Rotary Control Valve

Fisher FIELDVUE DVC6200 Series Hazardous Area Approval Nameplates

M Series Manual Handwheel Gear Actuator

Baumann 24000S Stainless Steel Control Valve

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher CV500 Rotary Globe Control Valve

Monitoring Health of External Solenoid Valve (SOV) with FIELDVUE DVC6200 SIS Digital Valve Controllers

WARNING. Mounting Instructions D103998X012 June DVC6200/DVC2000 Digital Valve Controller Linear Actuator Side Mount

Type D2 FloPro Control Valve

Fisher WhisperFlo Aerodynamic Noise Attenuation Trim

Type 1035/El-O-Matic Rack-and-Pinion Rotary Actuator

Fisher 546 Electro Pneumatic Transducer

Fisher POSI-SEAL A31A Cryogenic High Performance Butterfly Valve

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves

Fisher V500 Rotary Globe Control Valve

Fisher V260 Ball Control Valve

Baumann Flexsleev Sanitary Control Valve

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher D4 Control Valve Assembly

Fisher 8532 High-Performance Butterfly Valve

Fisher 3024C Diaphragm Actuator

Fisher 1052 Size 70 Diaphragm Rotary Actuator

Fisher CCV-N Fuel Gas Control Valve

Fisher V150S Slurry Vee-Ball Control Valve

Fisher 685SE and 685SR Piston Actuator

Fisher L3 Pneumatic Level Controller

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

Fisher 3660 and 3661 Positioners

Fisher 8532 High-Performance Butterfly Valve

Fisher 2625 and 2625NS Volume Boosters

Baumann Sanitary Angle Control Valve

Fisher Multi-Port Flow Selector Valve

Fisher RSS Lined Globe Valve

Baumann Sanitary Control Valve

Baumann Sanitary Control Valve

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators

Fisher 461 Increased Outlet Angle Sweep-Flo Valve

Design V250 Rotary Control Valve

Fisher 644 and 645 Differential Pressure Pump Governors

WARNING. Mounting Instructions D103996X012 May DVC6200/DVC2000 Digital Valve Controller on Linear Actuator

Fisher Control-Disk Valve NPS 14-24

L3 Pneumatic Level Controller

Baumann Mikroseal Control Valve

Design V150S Slurry Vee-Ball Control Valve

Baumann Way Control Valve

Fisher FB Control Valve

Fisher Control-Disk Rotary Valve

Fisher CAV4 Control Valve

Fisher CAV4 Control Valve

Fisher CV500 Rotary Control Valve

Fisher CL600 Control-Disk Valve

Fisher D and DA Control Valves

Zero Point Calibration HART Communicating Fisher FIELDVUE DVC6200 Digital Valve Controllers

Fisher Large ED/EWD and ET/EWT Valves NPS 12 through 30

Fisher RSS Lined Globe Valve

Fisher 8580 Rotary Valve

CML Electric Actuator for Baumann Series

Fisher 8580 Rotary Valve

Fisher D4 Control Valve Assembly

Fisher YD and YS Control Valves

WARNING. Mounting Instructions D103778X012 June 2013

Design V260 Ball Control Valve

Vee-Ball Design V150, V200 and V300 Rotary Control Valves

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Fisher Rotary Valve Selection Guide

Features. Product Bulletin 51.6:8590 August Valve D104017X012

Transcription:

377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls below a specific point. When supply pressure falls below the trip point (see figure 1), the trip valve causes the actuator to fail up, lock in the last position, or fail down. When the supply pressure rises above the trip point, the 377 trip valve automatically resets, allowing the system to return to normal operation. The trip valve can be top mounted on a manifold, yoke mounted, or bracket mounted to match the application requirements. 377 trip valves can be used with Fisher 480, 585C, 685, 1061, 1066, 1069, and Bettis G Series piston actuators. W4292 1 Features Cost Effective Single trip valve construction reduces costs and spare part requirements of those systems using three separate switching valves to perform the failure functions. A single trip valve greatly simplifies piping requirements. Ease of Mode Conversion Conversion to any of the fail modes requires only minor hookup changes. Adjustable Trip Valve The trip point is adjustable for specific supply pressure requirements. Reliable Operation The trip valve design includes large diaphragm areas and few moving parts for efficient performance, minimum maintenance, and long service life. W8435 1 Fisher 377 Trip Valve Mounted on Size 130 585C Actuator www.fisher.com

Product Bulletin 377 Trip Valve Specifications Available Configurations When supply pressure falls below the trip point, 377D Trip Valve: Fails actuator piston down. Includes check valve and volume tank. 377L Trip Valve: Locks actuator piston in the last position. 377U Trip Valve: Fails actuator piston up. Includes check valve and volume tank. 377CW Trip Valve: Fails fully clockwise to close the valve. Requires check valve and volume tank. Trip valve moves piston to either up/down position and requires actuator configuration for actual clockwise movement. 377CCW Trip Valve: Fails fully counterclockwise to close the valve. Requires check valve and volume tank. Trip valve moves piston to either up/down position and requires actuator configuration for actual counterclockwise movement. All 377 trip valves can be converted to any of the above fail modes with minor hookup changes Allowable Supply Pressure for Trip Valve (1) Maximum: 10.3 bar (150 psig) Minimum: 3.8 bar (55 psig) Outlet Pressure (1) Normal Operation: Pressure from control device Fail Up or Fail Down Mode: Maximum volume tank pressure Lock In Last Position: Respective cylinder pressure Trip Point (2) Adjustable from a minimum of 2.8 bar (40 psig) to a maximum of 72 percent of supply pressure; see figure 1 Reset: 12.5 to 33 percent above adjusted trip point -Continued- Flow Coefficients (C v ) (3) Depends on flow path (shown in figure 3) as follows: Port A to Port B and Port D to Port E: 0.5 Port B to Port C and Port E to Port F: 0.6 Body Connections 1/4 NPT internal Temperature Capabilities (1) Nitrile Diaphragms and O Rings: -40 to 82 C (-40 to 180 F) Fluorocarbon Diaphragms and O Rings: -18 to 104 C (0 to 220 F) Volume Tank Maximum Internal Working Pressure (for 377D, 377U, 377CW and 377CCW trip valves) Standard: 10.3 bar (150 psig) for non ASME approved applications (4) ASME Approved Applications: Rated 10.3 bar (150 psig), maximum; 9.3 bar (135 psig), recommended Volume Tank Sizing See sizing section Hazardous Area Classification Complies with the requirements of ATEX Group II Category 2 Gas and Dust 377 SST Safety Instrumented System Classification SIL 3 capable - certified by exida Consulting LLC Table of Contents Features... 1 Safety Certification... 3 Principle of Operation... 4 377D Trip Valve... 4 377L Trip Valve... 6 377U Trip Valve... 7 377CW and 377 CCW Trip Valves... 7 Volume Tank Sizing... 8 Installation... 9 Ordering Information... 10 Application... 10 Trip Valve... 10 2

377 Trip Valve Product Bulletin Specifications (continued) Mounting Top Mounted: Manifold mounted between a 3570 positioner and a 480 actuator (manifolds cannot be supplied with 585C, 685, 1061, 1066, and 1069 piston actuators) Side Mounted: Yoke mounted or bracket mounted for use with a FIELDVUE DVC6200, DVC6200f, DVC6200p, DVC6000, or DVC6000f digital valve controller Approximate Weight Trip Valve Aluminum: 0.95 kg (2.1 pounds) Stainless Steel: 2.31 kg (5.1 pounds) Mounting Manifold: 0.5 kg (1.2 pounds) Volume Tank: Varies between 5.4 and 363 kg (12 and 800 pounds) depending on size Construction Materials Housing: Aluminum or Stainless steel Cover: 25% mineral filled thermoplastic polyester O Rings: Nitrile or fluorocarbon Diaphragms: Nitrile or fluorocarbon Interior parts Aluminum construction: Brass, aluminum, steel, and stainless steel Stainless Steel construction: Stainless steel 1. The pressure/temperature limits in this document and any applicable standard or code limitation should not be exceeded. 2. If the trip point is not specified, the trip point is factory set at 72 percent of supply pressure or 2.8 bar (40 psig), whichever is higher. 3. Values represent nominal C v measures for each port pair using a trip valve/actuator combination. 4. This tank is rated at 14.5 bar (240 psig) in LP service. When used with air, the rating should be considered to be 10.3 bar (150 psig), consistent with the maximum pressure allowed for the 377 trip valve. Figure 1. Maximum Trip Point Settings TRIP POINT, PSIG A2779 2 110 100 90 80 70 60 50 40 SUPPLY PRESSURE, BAR 4 5 6 7 8 9 10.3 10 7.6 55 60 70 80 2 90 100 110 120 SUPPLY PRESSURE, PSIG MAXIMUM TRIP POINT SETTING TO ENSURE RESET 1 130 140 7 6 5 4 3 150 TRIP POINT, BAR Safety Certification The 377 SST is certified for use in Safety Instrumented System (SIS) applications. Certification is by exida Consulting LLC, a global provider of functional safety and control system security (see figure 2). SIS certification is identified on the product by a label affixed to the pilot body. The functional safety assessment was performed to the requirements of IEC 61508: ed2, 2010, SIL3 for mechanical components. Figure 2. exida Certificate 1 Trip point may be set to any value between 2.8 bar (40 psig) and the maximum trip point line. 2 Reset occurs a 12.5 to 33 percent above adjusted trip point. 3

Product Bulletin 377 Trip Valve Principle of Operation Figure 3. Simplified Sectional View of Trip Valve 377D Trip Valve In normal operation, supply pressure loads the upper diaphragm (see figure 3) of the unit. The valve plug spring keeps the exhaust port closed. Supply pressure also loads the lower diaphragm through the restriction, causing the plug assemblies to move down and isolate ports C and F while connecting port A to B and port D to E. UPPER Normal actuator control pressure flows from the control device to the top of the cylinder through ports A and B and to the bottom of the cylinder through ports D and E. A volume tank is charged to maximum supply pressure through a check valve in order to retain maximum supply pressure in the volume tank if supply pressure drops. VALVE PLUG SPRING SUPPLY CONNECTION PORT D PORT E EXHAUST PORT RESTRICTION PORT A PORT B When supply pressure falls below the trip point pressure in the fail down mode (see figure 4), the exhaust port opens, venting the supply pressure that is loading the lower diaphragm. This causes the upper ports of the plug assemblies to close and shut off normal pressure flow from the control device to the actuator. Volume tank pressure then flows through ports C and B to the top of the actuator cylinder, while pressure in the bottom of the actuator cylinder is vented through ports E and F. The pressure imbalance created forces the actuator piston down. W4303 1 PORT F PORT C PLUG ASSEMBLIES When supply pressure is restored, it loads the upper and lower diaphragms, causing the trip valve to reset. The exhaust port closes. The upper ports of the plug assemblies open, and the lower ports close. Normal actuator control pressure flow from the control device is restored through ports A and B and ports D and E. The check valve opens and recharges the volume tank to the maximum supply pressure. 4

377 Trip Valve Product Bulletin Figure 4. Fisher 377D Trip Valve Shown Tripped MAIN SPRING SPRING ACTUATOR VALVE PLUG UPPER VENT EXHAUST PORT CONTROL DEVICE SUPPLY PRESSURE DVC6200 PORT D PORT E PORT A PORT B UPPER PORTS CHECK VALVE PORTS PORT F PORT C PLUG ASSEMBLIES VOLUME TANK GE08412-A A6905-1 SUPPLY PRESSURE CONTROL PRESSURE TO TOP OF CYLINDER (BLOCKED) CONTROL PRESSURE TO BOTTOM OF CYLINDER (BLOCKED) PRESSURE TO TOP OF CYLINDER (FROM VOLUME TANK) PRESSURE FROM BOTTOM OF CYLINDER (VENTING) LOADING PRESSURE (BEING VENTED) 5

Product Bulletin 377 Trip Valve Figure 5. Fisher 377L Trip Valve Shown Tripped MAIN SPRING SPRING VALVE PLUG UPPER EXHAUST PORT VENT ACTUATOR SUPPLY PRESSURE PORT D PORT A DVC6200 CONTROL DEVICE PORT E PORT B PORTS PORT F PORT C UPPER PORTS PLUG ASSEMBLIES GE08414-A A6906-1 SUPPLY PRESSURE CONTROL PRESSURE TO TOP OF CYLINDER (BLOCKED) CONTROL PRESSURE TO BOTTOM OF CYLINDER (BLOCKED) PRESSURE TO TOP OF CYLINDER (STATIC) PRESSURE FROM BOTTOM OF CYLINDER (STATIC) LOADING PRESSURE (BEING VENTED) 377L Trip Valve When supply pressure falls below the trip point in the lock in last position mode (see figure 5), the exhaust port opens, venting supply pressure from the lower diaphragm. This causes the upper ports of the plug assemblies to close and the lower ports to open. Since ports C and F are plugged, no pressure change occurs on either side of the actuator piston, and the piston is pressure locked in position upon loss of supply pressure. No volume tank is necessary in this mode. When supply pressure is restored, the plug assemblies move back into the normal operating position, and supply pressure flows from the control device through ports A and B to the actuator. 6

377 Trip Valve Product Bulletin Figure 6. Fisher 377U Trip Valve Shown Tripped MAIN SPRING SPRING VALVE PLUG UPPER EXHAUST PORT VENT ACTUATOR CONTROL DEVICE SUPPLY PRESSURE PORT D PORT E PORT A PORT B DVC6200 CHECK VALVE PORTS PORT F PORT C UPPER PORTS PLUG ASSEMBLIES VOLUME TANK GE08413-A A2284-6 SUPPLY PRESSURE CONTROL PRESSURE TO TOP OF CYLINDER (BLOCKED) CONTROL PRESSURE TO BOTTOM OF CYLINDER (BLOCKED) PRESSURE TO TOP OF CYLINDER (VENTING) PRESSURE FROM BOTTOM OF CYLINDER (FROM VOLUME TANK) LOADING PRESSURE (BEING VENTED) 377U Trip Valve The fail up mode of operation (figure 6) is similar to the fail down mode of operation except that connections to port C and F are reversed. When supply pressure falls below the trip point, the top of the actuator cylinder vents, and volume tank pressure loads the bottom of the actuator cylinder. The pressure imbalance created forces the actuator piston up. 377CW and 377CCW Trip Valves Makes use of the 377D or 377U trip valve configurations, a piston actuator, and volume tank with check valve to move the piston actuator to either the up or down position. Requires the actuator and valve configuration for actual clockwise or counterclockwise movement. 7

Product Bulletin 377 Trip Valve Volume Tank Sizing Note State and local regulations may require the use of ASME approved volume tanks. It is the user's responsibility to determine requirements and applicable regulations for proper volume tank selection. Several different tanks of varying capacities are available. The volume tank must be selected so that its pressure at any time is greater than the minimum percentage of maximum supply pressure required to stroke the actuator (see figure 7). Figure 7. Volume Tank Sizing Graph 1. Size the volume tank as indicated below: For Actuators on Sliding Stem Valves, Determine: Where: For Actuators on Rotary Shaft Valves, Determine: Y = F/AP x 100 Y = P r /P x 100 Y = Minimum failure positioning percentage F = Actuator thrust required in normal operation to position the valve at the desired limit of travel A = Effective piston area (from the appropriate actuator bulletin) P = Maximum supply pressure available P r = Highest pressure required by the actuator to stroke the valve (from the appropriate actuator sizing technique) 2. With the minimum failure positioning percentage obtained in step 1, enter the value on the abscissa of the graph in figure 7. Locate the corresponding point on the curve, and read across to find the volume ratio, R. VOLUME RATIO, R A2281 1 MINIMUM FAILURE POSITIONING PERCENTAGE, Y 3. Determine: V T = (XA)/R Where: X = Maximum actuator travel from the appropriate actuator bulletin. For rotary actuators, substitute total displacement (XA). Actuator displacement can be found in the product bulletin, or contact your Emerson sales office or Local Business Partner. V T = Minimum volume tank size required R = Volume ratio from step 2 8

377 Trip Valve Installation The 377 trip valve may be mounted in any position without affecting normal operation. Dimensions are shown in figure 8 and tables 1 and 2. Table 1. Standard Volume Tank Dimensions Tank Volume J L Liters Inch 3 /Gal mm Inches mm Inches 11.8 721/3.1 309 12.16 318 12.5 21.6 1315/5.7 310 12.19 451 17.75 32.3 1970/8.5 309 12.16 595 23.43 42.9 2615/11.3 309 12.16 737 29.00 65.6 4001/17.3 309 12.16 1095 43.12 131.1 8002/34.6 Requires two 65.6 liter (4001 inch 3 / 17.3 gal) volume tanks Product Bulletin Table 2. ASME Approved, Canadian Registered Volume Tank Dimensions Tank Volume J L Liters Inch 3 /Gal mm Inches mm Inches 8.5 518/2.2 208 8.19 337 13.25 24.9 1520/6.6 305 12 427 16.81 30 1831/7.9 254 10 684 26.94 42.8 2609/11.3 305 12 681 26.81 68.8 4199/18.1 360 14.19 792 31.19 71.6 4371/18.9 305 12 1087 42.81 143.3 8742/37.86 Requires two 71.6 liter (4371 inch 3 / 18.9 gal volume tanks 114 6930/30 406 16 965 38 227 13860/60 508 20 1219 48 303 18480/80 610 24 1600 63 454 27720/120 610 24 1702 67 908 55440/240 762 30 2134 87 Figure 8. Dimensions of Trip Valve with Manifold (also see tables 1 and 2) 57 (2.25) CAP REMOVAL CLEARANCE 1/4 18 NPT SUPPLY CONNECTION 154 (6.06) PORT D 100 (3.94) 46 (1.81) PORT E PORT C PORT F 141 (5.56) L J STANDARD TANK 1 L J ASME APPROVED TANK 1 AF4605 K 19A7995 A A2778 4 76 90 (3.00)(3.56) 54 (2.12) 1/4 18 NPT VENT CONNECTION mm (INCH) 1 Refer to table 1 and 2 for J and L dimensions 9

Product Bulletin 377 Trip Valve Ordering Information When ordering specify: Application 1. Available supply pressure 2. Actuator type number and size 3. Aluminum or stainless steel construction 4. Input signal range 5. Operating ambient temperature 6. Trip point (If the trip point is not specified, the unit is factory set to trip at 72 percent of supply pressure or 2.8 bar (40 psig), whichever is higher.) 7. Volume tank size Trip Valve Refer to the specifications. Review the information under each specification and in the referenced figures. Specify the desired choice wherever there is a selection to be made. Be sure to specify the type number as described in the Available Configurations specification. Refer to table 3 for guidelines on specifying the correct trip valve. Table 3. Guidelines for Specifying Fisher 377 Trip Valve Actuator Type Fail Mode Valve Action (1) Trip Valve PDTC 377U Fail Open PDTO 377D Sliding Stem PDTC 377D Fail Closed PDTO 377U Rotary: Fully Clockwise 377CW Clockwise 1035 Fully to Close 377CCW Bettis G Series Counterclockwise Fully Clockwise 377CW Rotary: Fully 1069 377CCW Counterclockwise 1. PDTC Push Down to Close; PDTO Push Down to Open 10

377 Trip Valve Product Bulletin 11

Product Bulletin 377 Trip Valve Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Automation Solutions Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 121985, 2017 Fisher Controls International LLC. All rights reserved.