Operating instructions K- Control 4960, 4965, Always on the safe side.

Similar documents
Operating Instructions K Always on the safe side.

Operating Instruction K-Control TLC 4955, 4956, Always be on the safe side.

Operating Instructions type Always on the safe side.

Instructions for use K-ERGOgrip Always on the safe side.

Instructions for use Spare cartridge for COMPACTtorque 636 P, 636 CP and POWERtorque 646 B, 646 C , Always be on the safe side.

PURE SINE WAVE DC TO AC POWER INVERTER

Instructions for use. PHYSIO Evo/Evo F/One

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Technical Manual Electrical Power Supply System T4002

Instructions for use. QUATTROcare PLUS 2124 A Always be on the safe side.

Installation manual wall-mounted distributor

Operating Instruction INTRAmatic Prophy Handpiece 19 ES

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Installation manual portable distributors

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Level Measuring Sensor for Diesel Fuel Tanks

Demco. Model E Bedienungsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones para el servicio Инструкция по эксплуатации

Katalysator Nr /

Operating Instructions

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Mounting and Operating Manual Non-Return valves Swing-Check valves

OPERATING INSTRUCTIONS

Assembly and Maintenance Manual Type ASNU

Wilo-Control SC-Fire Jockey

Technician's instructions. GENTLEpower LUX Contra-angle 25 LP - REF

HST -LS Interlocking device (Translation of Original Manual)

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

M A N U A L. Field Current Controller F2.2

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

basic quattro No /

Assembly and Maintenance Manual Type AS

TPAK Series COOLANT PUMP

c-go 24V/6A 24V/8A 24V/12A

Installation instruction Sound Booster Pro Active Sound

OPERATING INSTRUCTIONS

Multi-Mover Charger for model L25

Content Copyright...1 Disclaimer...2 General advice...3 Safety Instructions...4 References Of Legal Regulations For Operation...4 Hints...5 Scope Of D

USE AND INSTALLATION HANDBOOK

KSZ 10B Current Probe Calibrator. Instruction Manual

Operating instructions

BODAS Pressure sensor PR3 series 10

DC Master 24/ A

TPHK Series Immersible Pump

Register your instrument! HeatSealer S100. Operating manual

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Compact System NRGS 11-2 NRGS Original Installation Instructions English

VITA ZYrcomat. Operating manual Date of issue: 01-05

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Battery Charger. Series EASY Charger. User s manual

HST-BL-2830MS & HST-BL-2830MS-USA

Assembly and Maintenance Manual Type RSBW

Charder. Medical scale. User instruction. Important information. This user instruction must be read before the medical scale is used.

English. Instruction and operation manual S 110. Power Meter

Swing Piston Compressors and Vacuum Pumps

KSZ 100B Current Probe Calibrator. Instruction Manual

Table of Contents. ENGLISH Contents Page

NEW SOLAR CHARGE CONTROLLERS

TPHK Series Immersible Pump

Type 6213 EV, 6281 EV

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

CAUTION CONTENTS 5.0 WARRANTY

Instructions for use DURAtec Prophy REF

Ex m Solenoid Operator Type 0519

Contents Copyright...2 General advice...2 Safety instructions...3 References of legal regulations for operation...3 Space of delivery for 37998, 37998

UVR-Mi UV-air flow Cleaner - Recirculator

JET 2000 Modell S42 EN

Oil-free piston compressors KK and piston vacuum pumps KV

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

WK 120QMM-6M/Z EL 120QMM-6M/M12

Operating Instructions for PAC800 Battery Charger

Content Copyright...1 Disclaimer...2 General Advice...3 Safety Instructions...4 Reference Of Legal Regulations For Operation...4 Hints...5 Scope Of De

Contents General advice...2 Safety instructions...3 References of legal regulations for operation...3 Installation instructions...4 Scope of delivery

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Contamination switch VS

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Armon Edero. User manual

Contents General advice...2 Safety instructions...3 References of legal regulations for operation...3 Installation instructions...4 Scope of delivery

A2P Single Phase Automatic Industrial Battery Charger

Operating manual. High-voltage testing adapter VAS 6558A/30. Operating manual. Customer documentation Revision: 00 Version: 07/2018

ACROBAT SWING STAND MODEL

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

Liquid Handling Station

Medimachine II. Dissociator and Homogenizator USER MANUAL. (code )

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

STAND MODEL FOR MACH M2

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

SPARE PARTS CATALOGUE

Installation Instructions Convertible Top Interface Porsche. 997 Cabrio. Article-ID Version

OPERATIONS MANUAL CR Thermoreactor

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Please read these operation instructions carefully before use and keep it for further reference.

Operating Instruction for Flowmonitor. Model: DF-WM

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Transcription:

Operating instructions Always on the safe side.

Vertrieb/distribution: KaVo Dental GmbH Bismarckring 39 D-88400 Biberach Tel.: 0 73 51 / 56-0 Fax: 0 73 51 / 56-14 88 Hersteller/manufacturer: Kaltenbach & Voigt GmbH Bismarckring 39 D-88400 Biberach

A 1 User information...2 A 1.1 Meaning of the pictograms...2 A 1.2 Important information...2 A 1.3 Precautions...2 A 1.4 Purpose and potential uses...3 A 1.5 Technical data...3 A 1.6 Combination Controller - handpiece...4 A 2 Scope of delivery/accessories...5 A 3 Electrical connection...5 A 4 Location...6 A 5 Mounting and connection...7 A 5.1 Mounting 4960...7 A 5.2 Mounting 4965 / 4970...8 A 5.3 Connection...8 A 6 Controls and functional elements...9 A 7 Preparations for commencing operation...10 A 8 Operation...11 A 8.1 Starting K-Control knee control unit 4960... 11 A 8.2 Starting K-Control Benchtop Control unit 4965....11 A 8.3 Starting a K-Control installation with the type 4970 Foot control unit....11 A 9 Operating faults...12 Guarantee conditions...14 Spare parts...15 EC- Declaration of conformity...18 Drilling template...20 1

A 1 User information A 1.1 Meaning of the pictograms Situations where failure to follow the instructions may lead to danger, damage to material or operating faults. Important information for operator and engineer. Automatic mode Automatic sequence Close, screw in, fasten, etc. Open, release, loosen + more, higher - less, lower Continuous operation Time, time sequence Disconnect mains plug I Device ON, turned on O Device OFF, unplug from the power supply A 1.2 Important information The instructions for use should be read by the user before starting up the unit for the first time, in order to avoid incorrect operation and other damage. If other language versions are required, please request these from your responsible KaVo agent. Duplication and distribution of the instructions for use (IU) require KaVo's prior consent. All technical data, information and properties of the product described in the IU correspond to the state on going to press. Modifications and improvements to the product as a result of new technical developments are possible. This does not imply any right to retrofitting of existing units. KaVo assumes no responsibility for damage arising through: external influences (poor quality of the media or inadequate installation) use of incorrect information improper use improperly performed repairs. Repair and maintenance work - apart from the activities described in these instructions for use - may be performed only by qualified technical personnel. In the event of modifications by third parties, the approvals become null and void. KaVo recommends using only original spare parts for operation and for repair. Please note that the EC Directive on waste electrical and electronic equipment applies to this product. Within Europe therefore, this product must undergo special disposal. For more detailed information about this, please contact KaVo or your specialist dental supplier. A 1.3 Precautions Safe operation and protection of the unit are ensured only through proper use in accordance with the instructions for use and using the tools approved for the purpose. The following should also be observed: the work safety regulations, the accident prevention regulations. Each time before switching on, check the set speed. Observe the permissible maximum speed and maximum pressure of the tools (according to tool manufacturer's instructions). A 1.4 Purpose and potential uses K-Control-installation is versatile and very suitable for working on crowns and bridges. A 1.5 Technical data Dimensions and weight K-Control Knee-Operated Control Unit type 4960 Width: 95 mm Depth: 280 mm Height: 235 mm Weight: approx.3 kg K-Control Benchtop Control Unit type 4965 Width: 95 mm Depth: 280 mm Height: 235 mm Weight: approx. 3 kg K-Control Foot Control Unit type 4960 Width: Depth: Height: Weight: 245 mm 275 mm 125 mm approx.3 kg Rated voltage Line voltage fluctuations < ± 10 % Voltage range: 100 / 120 / 2 V 50 / 60 Hz Rated power K-Control units max.220 W 2

Speed range Right-handed rotation: 1 000-35 000 min -1 (K 5 Handpiece) 1 000-25 000 min -1 (K 9 Handpiece) 1 000-40 000 min -1 (K11 Handpiece) 1 000-40 000 min -1 (K10 Handpiece) 1 000-50 000 min -1 (K12 Handpiece) 5 000-60 000 min -1 (SF-Handpiece) 1000-50 000 min -1 (K-POWERgrip) 1000-50 000 min -1 (K-ERGOgrip) Left-handed rotation, limited to about 5,000 min -1 control max 000/min 4620 Intermittent service 2 min / on 8 min / off Pollution level 2 Overvoltage category ll 4960 4965 4970 Amblent conditions: Max. elevation 2000 m above sea level Permissible in inner rooms Permissible ambient temperature range 5 C - 40 C Permissible up to a max. relative humidity of 80% We reserve the right to make any alterations. Transportation and storage conditions Temperature range: -20 C to +70 C Relative humidity: 5% to 95% (noncondensing) Air pressure: 700 hpa to 1060 hpa Prior to start-up, very cold products must be heated to a temperature of 20 to 25 C. Avoid condensation. 0 @ 2 3 4 5 Rating plate Provides information on: @ Manufacturer 2 Order number (REF number) 3 GS-Mark 4 For information about proper disposal, see A1.2 5 CSA-Mark 6 Year of manufacture - Serial number 7 CE-Mark according to 89/336 EWG 8 VDE-Mark 9 Mode: intermittent service: 2 min, 8 min pause 0 Unit type 9 8 6 7 3

A 1.6 Combination Controller - handpiece In the combination with K-Control control units of types 4960, 4965 and 4970, the following handpieces can be operated: 4960 4965 K 5 Handpiece 4910 K 9 Handpiece 950/955 K 9 Handpiece 49 K 9 Compact motor 970 K 9 Cutter spindle 960 K 10 Handpiece 4950 (with Adapter 0.674.4721) K 11 Handpiece 4990 K 12 Handpiece 4940 SF Handpiece 4005 (with supply cable 0.674.4921) K-POWERgrip 4941 K-ERGOgrip 4944 control max 000/min The safty of the K-Control control units with handpieces can be guaranteed only with the handpiece/control unit combinations approved by KaVo. 4970 K-POWERgrip K12 K5 K11 K9 SF K-ERGOgrip 4

A 2 Scope of delivery/accessories K-Control Knee-operated control unit 4960 4960 4965 or K-Control Benchtop, control unit 4965 optional Foot switch 4620 Mat.-No. 0.223.2085 or control max 000/min 4620 K-Control Foot control unit 4970 4970 A 3 Electrical connection Electrical connection Check that the local mains voltage and mains frequency conincide with the specifications on the rating plate and the fuse holder @. Adapt if required. Voltage adaptation to 100 V/120 V or 2 V. By removing the fuse holder @, the sleeve 2 with contacts (including fuses) can be removed. The adaptation is achieved by appropriately rotating the sleeve until the required voltage, 100 V/120 V or 2 V, appears in the inspection window of fuse holder @. @ @ 120100 2 Connected load. Nominal power max. 220 W. Disconnection: Use mains plug as disconnection. 5

control max 000/min A 4 Location The K-Control Knee control unit, type 4960, is made to be attached to the side of a storage cabinet (A 5.1). 4960 4965 The K-Control Benchtop control unit, type 4965, is made to be set on a workbench and connected underbench with Foot switch type 4620 (A 5.2). 4620 The K-Control Foot control unit, type 4970, can be set unsecured on the floor (A 5.2). 4970 6

A 5 Mounting and connection A 5.1 Mounting 4960 The K-Control Knee control unit, type 4960, is made to be fastened to the side of a storage cabinet on a suspenslon rail 1 (drilling template see page 20). Fix in place at the front with screws and insert mains plug into a grounded mains socket which is easy to reach. (Similarly if using an extension line) Ø2,3 12mm page 20 Ø3,5 1 Demounting 7

max A 5.2 Mounting 4965 / 4970 Set K-Control Benchtop control unit, type 4965 on a workbench 4965 Set K-Control Foot control unit, type 4970, on the floor under a workbench. Fix in place at the front with screw and insert mains plug into a grounded mains socket which is easy to reach. (Similarly if using an extension line) control 000/min A 5.3 Connection 4970 Plug in Handpiece and foot switch and screw finger tight. 4965 Plug in Handpiece and screw finger tight. 4960 4970 8

A 6 Controls and functional elements 1 Digital speed and malfunction indicator 2 Speed limitation preselector 3 Direction switch (counterclockwise running limited to max. 5000 min -1 ) 4 Mains switch "0"/"1" Ì \ fi # @ 5 Knee switch 6 Speed preselector (continuous) Ì 7 Suspension rail 8 Fuse holder with voltage adjustment 9 Motor sockets (4-pole)» # @ Starter socket (5-pole) (Foot switch)» Foot switch Type 4620 w Foot lever # control max 000/min @ Control cable jack (connection to the dust extractor) 9

A 7 Preparations for commencing operation On K-Control control units 4960 and 4965, push mains switch to the "0" OFF position. Switch the K-Control Foot control unit, type 4970, to "0" OFF by letting back the foot lever. Set sliding switch 2 or button 2 for speed limitation to max.,000 min -1. Set direction switch # to clockwise (yellow LED does not light up) or R. For counterclockwise, the handpiece speed is limited to about 5000 min -1. # @ # @ Do not operate or lay down your Motorhandpiece, unless an instrument or the test pin is clamped in the chuck. When the chuck is open, Handpiece is locked, and inadvertent use will cause the K-Control control unit to switch to malfunction. Malfunction indicator 1 lights up or begins to flash. # control max @ 000/min 10

control max 000/min A 8 Operation Check set speed each time before switching on. Regulations for prevention of accidents are to be observed! When preselecting a speed over,000 min -1, button 2 should be pressed (yellow LED lights up). This additional enabling serves for consciously registering the high speed and the resultant possible danger when using tools which may be unsuitable. Ì 4960 A 8.1 Starting K-Control knee control unit 4960 Preselect desired maximum speed on speed limiter 2. When the knee switch plate is pressed in the direction of the arrow the speed can be continuously regulated from 1000 min -1 to the preselected maximum speed. 4965 A 8.2 Starting K-Control Benchtop Control unit 4965. Preselect desired maximum speed on speed limiter 2. Start your Handpiece at the preselected speed by depressing Foot switch 4620 q. A 8.3 Starting a K-Control installation with the type 4970 Foot control unit.» 4620 By pressing the foot control lever in the direction of the arrow, the speed of the Handpiece can be regulated (enabled by sliding switch 2). Allowing the foot lever to return under spring pressure all the way back, stops the Handpiece. control max 000/min 4970 11

A 9 Operating faults Repairs and servicing work on the electrical part of this equipment must only be undertaken by experts or by persons trained in our factory who are aware of the safety regulations. Disconnect the mains plug from the power supply, resp. switch off the disconnecting switch before carrying out any maintenance work. 4960 In K-Control knee and table-top control units, error messages are shown visually on the display 1. In the K- Control foot control unit, error messages are indicated by flashing of the malfunction LED 2 (e.g. error message No. 7 = 7 x flashes, etc.). 4965 @ @ F Error display: F 0 C Main processor not running R Repair or replace motor electronics F Error display: F 1 C Overloading of motor, motor current above 4 A for 7 sec R Reduce motor load or stop and re-start with foot switch. F Error display: F 2 C Handpiece blocked for more than 3 seconds R Eliminate blocking, stop and restart 4620 control max 000/min F Error display: F 3 C No handpiece connected (also open circuit K9, K10) R Connect handpiece and restart 4970 F Error display: F 4 C No handpiece connected (also open circuit K5, K11, K12, SF) R Connect handpiece and restart F Error display: F 6 C Handpiece speed too high for longer than 2 seconds, a phase of the handpichas been interrupted or electronics are faulty. R Repair handpiece or control unit F = Fault C = Cause R = Rectificatio K12 K5 K11 K9 SF 12

F Error display: F 9 C Open circuit in speed potentiometer R Replace speed potentiometer with cable F Error display: F 10 C Magnets (Knee switch, Foot lever) inserted twisted R Insert magnets correct 4965 4960 F Error display: F 11 C Fault in hall-effect element R For 3 seconds after switching the device on, a self -diagnosis program is automatically activated. R Repair control unit F Error display: F 13 C Short-circuit in D.C. chopper transistor R Remedy: Repair control unit F Error display: F 14 C Measuring device for motor voltage is faulty R Repair control unit F Error display: F 17 4620 control max 000/min C Cooling attachment too hot (>90 ) R Repair control unit F Error display: F 18 C Temperature sensor on cooling R Repair control unit (short-circuit) 4970 F Error display: F 19 C Data loss in EEPROM R Repair or recalibration of the control unit F = Fault C = Cause R = Rectification K12 K5 K11 K9 SF 13

Guarantee provisions For the product cited in the transfer protocol, KaVo warrantees the end customer that the product will function properly, have no material or manufacturing flaws for 12 months from the date of purchase under the following conditions: In the case of valid complaints due to defects or a short delivery, KaVo will make good its warranty by replacing the product free of cost or repairing it according to your wishes. All other claims of any kind are excluded, especially claims for damages. In case of delayed performance, gross negligence or criminal intent, this shall apply only if there are no compelling legal regulations to the contrary. KaVo is not liable for defects and their consequences that arise from natural wear, improper cleaning or servicing, the nonobservance of instructions for use, servicing or connection, scale formation or corrosion, impurities in the air and water supply, or chemical or electrical influences that are unusual or impermissible according to the manufacturer's specifications. The warranty does not generally extend to lamps, glassware, rubber parts and the colour fastness of plastic parts. No liability is assumed when defects or their consequences can arise from manipulations or changes to the product by the customer or a third party. Claims from this warranty can only be asserted when the transfer protocol (copy) belonging to the product has been sent to KaVo, and the original can be presented by the operator or user. 14

1 0 0 2 1 20 x 1 0 0 0 / m i n 4960 0.245.5015 0.200.6529 0.200.6528 0.642.0272 0.642.0252 K c o n t r o l 0.260.9677 0.642.0282 n m a x 0.642.0561 F 6,3A 250V 0.221.9116 0.223.0050 0.223.2801 0.223.2735 0.642.0661 0.692.9021 0.692.9051 0.692.9031 0.692.9041 0.696.0221 AT 1.002.6852 0.642.0561 0.223.4142 DE 0.692.6881 CH 0.692.6891 USA/JP 0.692.6901 GB 0.692.6851 AUS 0.221.4909 0.224.2498 0.201.7065 0.696.0311 0.242.4012 0.260.8505 15

4965 0.245.5015 0.200.6529 0.200.6528 0.642.0272 0.617.0460 1,8 m 0.617.0410 1,0 m 0.642.0561 0.224.7001 0.617.0511 0.223.2085 0.223.0050 0.223.2735 0.642.0661 F 6,3A 250V 0.223.2801 0.223.2111 0.692.9021 0.220.0423 0.692.9051 0.692.9031 0.696.0221 AT 1.002.6852 0.642.0561 0.692.9041 0.223.4142 DE 0.692.6881 CH 0.692.6891 USA/JP 0.692.6901 GB 0.692.6851 AUS 0.221.4909 0.224.2498 0.201.7065 0.696.0311 0.242.4012 0.260.8505 16

4970 0.642.0572 0.642.0572 0.642.0641 3 0 0 0 0 / m i n 0.221.9110 0.642.0582 0.223.2059 0.642.0582 F 6,3A 250V 0.223.2801 0.223.2735 T 4.0A 0.642.0661 0.221.4909 0.201.7127 0.223.0050 0.251.4545 0.220.0443 0.641.7642 0.696.0221 AT 1.002.6852 4x 0.260.9654 0.221.9116 0.642.0562 0.258.6010 0.223.4101 DE 0.223.4110 CH 0.223.4127 USA/JP 0.691.8101 GB 0.691.8091 AUS 17

18

19

Drilling template Ø2,3 mm 156,5 mm 90 mm MASTERspace 93 mm FLEXspace Ø2,3 mm 53 mm MASTERspace 51mm FLEXspace 20

1.000.4575 Fk 11/07 en 01.26 KaVo Dental GmbH. D-88400 Biberach/Riss Telefon +49 7351 56-0 Fax +49 7351 56-1488 Internet: www.kavo.com