Chandrashekar.p. Electrical and Electronics Engineering, PESITM-Shivamogga, Karnataka-India

Similar documents
Hydraulic power unit CE8L Technical data

Inductive Proximity Sensor

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Inductive Proximity Sensor

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Inductive Proximity Sensor

Proximity Sensors. Reference Information. Principles of Operation. Proximity Sensors

Transistor Remote Modules

Model Pressure range ON/OFF output Linear output

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Model Pressure range ON/OFF output Linear output

Inductive Proximity Sensor

Inductive Proximity Sensor

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Practical No: Aim: List out the tools required for Instrumentation Workshop and draw the diagram of any two tools

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Electrical Control System Components Basics of Magnetic Control :

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Maintenance Instructions & Parts List

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

SYSMAC Transistor Remote Module

General Purpose Relay

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

A22NK. Key-type Selector Switches

E2EZ-X2D1-N E2EZ-X2D2-N

Proximity Sensors. Reference Information. Principles of Operation. Proximity Sensors

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

PHOTOELECTRIC S300 PA MAXI SENSORS APPLICATIONS.

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

HIGH POWER SOLENOID DRIVER 1

Inductive Proximity Sensor

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

AF series contactors (9 2650)

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

SG-B1 SERIES / SG-A1 SERIES

AF series contactors (9 2650)

Switching Power Supply

The galvanic separation of the primary or actuating circuit and the load circuits

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

Integrated Control modules

Inductive Proximity Sensor

Safety Control HR1S-AC. Safety Relay HR1S-AC

SA1W: Water Detection Sensors

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

Vacuum Automation 2.1. The future depends on good product choices

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

Paddle-wheel flow controller for On/Off control

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS

Inductive Proximity Sensor E2Q2. Ordering Information. Limit Switch Style Proximity Sensor with 5-Position Sensing Head

Paddle-wheel flow controller for On/Off control

Dissolved Oxygen Measurement System with Air Blast Cleaner

Safety Interlock Switches

ABL Series. Relay Terminal Block (Screwless Type) Features

MPS Series Proximity Switches

6mm and 14mm Slim Interface Relay

Inductive Proximity Sensor

Catalog listing. 1to5Vdc (proportional to intensity of incoming light) HPX-MA

D R C- 4 0 s e r i e s

RVS-DN Digital Reduced Voltage Motor Starter

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

6mm Interface Relays RV8 Series

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Part # Features & Applications Specifications Cross Reference

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

Paddle-wheel flow controller with optical principle for On/Off control

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Cylindrical type proximity sensor

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

HBSO1 Oil switch. Instruction manual. For detecting oil in refrigeration systems WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Proximity Sensors E-1. Standard E2E/E2EG E-2 Antispatter E2EQ E-32 Chemical Resistance E2FQ E-40. Cylindrical

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

Model Number Structure

Product Discontinuation Notices. Discontinuation Notice of Compact Non-contact Door Switch D40B series

Inductive Special Properties

Transcription:

Protection and Control of Electrically Operated Over-Head Track Cranes (EOT) Using Multi-Functional Programmable Counter and Inductive Proximity Sensor. Chandrashekar.p Electrical and Electronics Engineering, PESITM-Shivamogga, Karnataka-India Email:Cschandran44@gmail.com Abstract Control and Protection Devices Play a Great Role in the Working of the Electrical Equipment s. The protection of EOT Cranes from Free-Fall/ Breakdown of due to Over-Speed needs a Protection and control devices to minimize the accidents And avoid damage to Human life and Equipment. In the Existing System Hydraulic-Operated Caliper Brake unit is used for Protection due to Breakdown and Free-Fall of Crane. The Present system is Operator Dependent and time delayed. Adequate alarm and Isolation from Power Circuit are not available. It is not been Integrated with the Existing Process Automation System. The main Objective of the Current Project is to utilize the Flexible Operation Of Counter and Sensor for Control and Protection of Crane from failure. Programmable Counter ProvidesInformation about the Initial and Final set Values of Speed through Sensor. It sets the Alarm during fault Condition. In addition the most Important things is that it sends Signals to the Caliper Brake unit and VVVF drive unit to take Necessary Actions and These things are Operator Independent and fully Automated. Introduction The most adaptable and the most widely used type of power driven crane for indoor/outdoor service is undoubtedly the three motion EOT crane. It serves a larger area of floor space within its own travelling restrictions than any other permanent type hoisting arrangement. The three motions of such crane are the hoisting motion, long Travel and the cross Travel motion. Each of the motions is provided by electric motors. In a steel plant, rolling mill, thermal powe plant, Hydro power plant, nuclear power plant, All manufacturing Industry this type of crane is considered indispensable. In short in all industries, wherein heavy loads are to be handled, EOT crane find its application. Working Principle 1. Bridge 2 No s 2. End carriage 2 No s 3. Wheel of the bridge At least 4 No s 4. Trolley (without auxiliary hoist) 1 251

5. Hoisting machinery set 1 No s 6. Wheels of Trolley At least 4 No s 7. Bottom Block(without auxiliary hoist) 1 8. Lifting hook 1 9. Rail on the gantry girder for crane movement 2 No s 10. Rail on the bridge for Trolley movement 2 No s 11. Operators cabin 1 No s The Eot Crane is Primarily Engaged in Handling the Ladle from the supplier to the Casting unit. The temperature of the Hot metal in the ladle Varies around 1600 to 1700K. This Crane can be Operated in 5 Variable Speed which depends on the Requirement.Free-fall/ Breakdown of coupling arrangement or free-fall of ladle from the crane due to over-speed may occur and these accidents have to be overcome. It is not integrated to overcome with the Existing Process automation system. The casting control is done at the third floor where the operator on the Crane gives the pressure set points whereas the compressor controller is at the ground floor. The objective of Current Project is to Protection, Control and breakdown of Eot Crane by using the Multi- Function Programmable Counter an Inductive Proximity Sensor which adds to plant automation. Caliper Disc Brake - Power Unit (CE8L) The Hydraulic Power unit CE8L (shown in Fig.1) is intended to deliver a Hydraulic Pressure to open the Emergency Hydraulic Brakes. Hydraulic Power Unit CE8L Power-Flow Diagram of the Hydraulic Power-Unit BR1-Filling Port LD1- Flow Limiter BV-Draining Port ¼ G LP- Main Pressure Limit Valve CA1- Check Valve LP1- Hand Pump pressure limit Valve CA2-Check Valve M-Electrical Motor CA3- Hand Pump Check Valve P1- Gear Pump 252

Components: CA4-Hand Pump Check ValveP2- Hand Pump CA5- Check Valve PP-Pressure Port CP1-Pressure Switch R-Reservoir CR-Suction Strainer 1G-Manometer EV1-Solenoid Valve 1Q-Isolation Cock of the Manometer 2.2 Operating Principle of Caliper Brake Electrical Connection of Caliper Brake Unit 253

a) Opening of the Calipers When the Hydraulic Power unit is Switched On, the solenoid valve EV1 (NO) closes and the motor M starts simultaneously. This motor drives the gear pump P1 which gives the oil pressure allowing the hydraulic calipers to Open. The Opening of the Pressure Switch CP1, included in the working Circuit, stops the motor M when working Pressure reaches the maximum set level. Then, the installation stays under pressure with the motor M stopped. If Pressure lowers down to the minimum level, the switch closes and starts the pump motor M again. Drawbacks in the Existing System 1. The Existing System has no Protection under Free-Fall and Breakdown of crane due to any failure such as Breakdown in Various Gear Over-Speed due to failure in various stages of Speed Reduction. 2. The Present System is Operator Dependent 3. There is a Time-delay in the System. 4. Caliper Brakes needs actuator signal from the Operator which is time delayed. 5. The Failure due to any of the above reasons, will lead to Free- Fall of 45 T hot metal from such height due to its own weight. Thus it results in disaster; Evenly Everything will turn into Ashes Proposed System of Protection and Control The Proposed New System of Control mainly uses 3 Components 1. Multi-function Programmable Counter. 2. Inductive Proximity Sensor 3. Mild-Steel Disc Unit. 1. Multi-Function Programmable Counter Display and Indications Inbuilt Connection Circuit 254

Specifications Power Input AC 100 240V, 50/60 Hz Input Voltage 85% to 110%, Rated Voltage Range Power Less than 10VA Consumption External Power 12V dc +10% or -10%, 100mA Supply Display Double-Line, 6-digit LCD display Non-Voltage input (NPN): ON impedance 1K ohm max. ON residual voltage: 2V max. Input Signal Voltage input (PNP): High Level: 4.5V to 30Vdc, Low Level:0 to 2V dc Relay: SPST max.250vac, %A ( resistance load ) Output 1 Transistor: NPN open Collector. When 100mA / 30Vdc, residual Voltage = 1.5Vdc max. Relay: SPDT max.250vac, %A ( resistance load ) Output 2 Transistor: NPN opens Collector. When 100mA / 30Vdc, residual Voltage = 1.5Vdc max. Dielectric 2000Vac 50Vac 50/60 HZ for Strength 1 minute Vibration Without damage: 10 to 55 Hz Resistance, Amplitude=0.75mm, 3 axes for 2 hours Shock Without damage : drop 4 Resistance times, 300m/s2, 3 edges, 6 surfaces, 1 corner Ambient Temperature Storage Temperature Altitude 200m or less Ambient Humidity O C to +50 C -20 C to +50 C 35% to 65% RH no condense 2. Operating Principles for Inductive Proximity Sensors Inductive proximity sensors are used for non-contact detection of metallic objects. Their operating principle is based on a coil and oscillator that creates an electromagnetic field in the close surroundings of the sensing surface. The presence of a metallic object (actuator) in the operating area causes a dampening of the oscillation amplitude. The rise or fall of such oscillation is identified by a threshold circuit that changes the output of the sensor. The operating distance of the sensor depends on the actuator's shape and size and is strictly linked to the nature of the material. 255

Outputs: These amplified D.C. sensors contain an output amplifier. They are supplied as 3 wire with function N.O. or NC and as 4 wire with complementary outputs (NO + NC) in the types NPN and PNP. Standard version include protected against short circuit, protected against polarity and peaks created by the disconnection of inductive loads. They are compatible with P.L.C. Conclusions From the above set-up and arrangement we can ensure control and protection of crane from possible failure this increases reliability of the system because of operator independent and additional Caliper brake, drive and power circuit can be disconnected immediately after the fault within fraction of seconds. Above all this is the most economical in Cost wise flexible for multiple operations. References 1. Delta CTA User Manual. 2. info@lubielectronics.com. 3. Electrical Macinery- P.S Bhimra Publishers. 4.Electrical and Electronics Measurements and Instrumentation A. K Sawhney. 5. Mild Steel Disc and Sensor Unit 256