Operating Manual Hyperion 924IPS. Short-Range DC Bar

Similar documents
ThunderION. Static Neutralising System. GB User's Manual 2

DRAFT COPY, NOT FOR DISTRIBUTION

Installation manual wall-mounted distributor

AEROSTAT HP-N-Ex Ionising Air Blower

Tina 11A Connection block

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Tina 4A Connection block

Power Distribution System User s Manual. Model: PDS-100

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Radian Research, Inc. makes no warranty on the accuracy of the information contained in this Operations Manual and accepts no liability for its use.

PD-1 POWER DISTRIBUTION UNIT

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Tina 10A/B/C Adaptor unit

ECONOMISER SERIES E2T USER MANUAL

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

MPS14 Rack Mount Power Supply

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

HST-BL-2830MS & HST-BL-2830MS-USA

HydroLynx Systems, Inc. Model 5033-XX Solar Panel. Instruction Manual

GB/US... LP11 lifting platform. Vers. 6.00

ROLLER SPREADER. Model - #171A-M Lee's Chapel Road Browns Summit, NC Tel: (800) Fax: (336) Web:

400W Solar Charger Maximum Power Point Tracker

CONTACTS EGR VALVE TESTER 66248

Battery Charger JCB- SCH20LI.2

Battery Charger JCB-FCH20LI2

Installation and Operations Manual

Unit 2, Rivington View Business Park, Station Road, Blackrod, Bolton BL6 5BN Tel: +44(0)

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

B-RAD Select USER MANUAL TABLE OF CONTENTS

USER MANUAL. Revision 1.0.1

PURE SINE WAVE DC TO AC POWER INVERTER

Eminox Electronic Service Indicator

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

AL-KO ESC USER MANUAL

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

MANUAL. Single charger

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

MICRO SWITCH INSTALLATION SHEET

FMC-1/2 Tina Muting unit

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Reverse Polarity MANUAL. Surechlor S3500

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Installation manual portable distributors

Ionizer (Nozzle type) Series IZN10

Model LA 4400 Time Delay OFF Controller

Car Battery Charger Instructions for Use

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

MAGNETO REPLACEMENT. Pre-Unit Twin Cylinder Motorcycles. ELECTRONIC IGNITION SYSTEM For 4 Stroke. With 12 VOLT Electrics, POS/ NEG Ground

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

USER GUIDE 12 V Lead acid batteries Ah

Battery Charger JCB-FCH12Li

DKG-114 MANUAL AND REMOTE START UNIT

RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION

DX Environmental Control Unit

Safety Sensor CSS 180 Product Information

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

ACTIVE SEAT SYSTEM. General User/ Safety Guide. ACTIVE CUSHIONS

Positive Displacement Pump

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R

KEEP FOR FUTURE REFERENCE POWER TRANSFORMER READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Rental Industry Safety Tester Safe Check 5s

Installation and Operating Manual

OPERATION MANUAL HARVEST ROYAL

User Manual. Solar Charge Controller 3KW

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

OPERATION MANUAL HARVEST CAVALIER

1500 Series Roll Off Hoist. Owner s Manual (5-06)

Pro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER

any other M6 hole. The Tether Point Wire is approximately 1m STR- SSB- (1, 2, 3, 4, 5 or 6) -TP

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

200W Solar Charger Maximum Power Point Tracker

INSTRUCTIONS AR-H

Owner s Manual & Safety Instructions

CX-SERIES ADVANCED BATTERY CHARGER

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

Operating Instructions. International English. CCS Dust Extractor

CONTACTS RELAY TESTER 66249

Snapshot. Hurricane 1300 USER MANUAL F-1300

LED FLASHER GND CONTROL FPC4N

V4 Cordless Lamp System User Guide

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

HPP1 MK5 Owner s Manual

Hydraulic Immediate Need Power Pack

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

ESC Series Engine Shutdown Control

Pressure Transmitters

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

NCSA 20plus Service Manual

Transcription:

Operating Manual Hyperion 924IPS Short-Range DC Bar

Contents Introduction 3 Unpacking and Inspection 4 Contents 4 Options 4 Features of Hyperion 924IPS 5 Installation 8 Operation 13 Maintenance 14 Troubleshooting 15 Technical Characteristics 16 Repairs and Warranty 17 CE Approval 17 Health and Safety 17 Products shown in this document may be covered by one or more patents, patents applied for and/or registered designs and/or trade marks. For further information please refer to our Head Office or visit www.meech.com. Meech Static Eliminators Ltd., 10.07.2015

Introduction The Hyperion 924 IPS is a compact pulsed DC ionising bar. It is used to control static electric charges in short range applications (20-150mm). An integral 7.5kV pulsed DC power supply allows for easy installation on printing, converting and packaging machinery. Requiring only a 24V DC supply, the 924 IPS removes the need to route high-voltage cabling through the machine. In most installations the default settings of the bar will provide exceptional static control. The local LED indicator shows the operational status of the bar and advises when the bar requires cleaning. Demanding installations can take advantage of the adjustable output of the 924 IPS. Using the optional Hyperion BarMaster remote programmer, the frequency, balance and voltage output can be optimised to suit the application. Additionally, the lon Current alarm setting can be changed to guarantee the required performance levels on critical processes. The Hyperion BarMaster remote programmer is available for purchase from the Meech network: Visit www.meech.com to find your nearest Meech office or distributor for further product information. 3

Unpacking And Inspection Your Hyperion 924IPS bar was carefully packed at the factory in a container designed to protect it from accidental damage. Nevertheless, we recommend careful examination of the carton and contents for any damage. If damage is evident, do not destroy the carton or packing material and immediately notify the carrier of a possible damage claim. Shipping claims must be made by the consignee to the delivering carrier. Contents: Standard 924IPS Bar Mounting Kit Options 4 Power Cable - 4 Pin M8 (straight or 90º elbow) Available in 2,3,5 and 10M lengths. 24V DC Supply & IEC cable BarMaster remote programmer. Allows optimisation of the output of the 924IPS

Features and Benefits of Hyperion 924IPS Low voltage wiring and Integrated Power Supply The 924IPS is powered by 24V DC via a 4-pin M8 Connector. Shockless Emitters The Titanium emitter pins on the 924IPS are resistively coupled to the high voltage supply. This avoids sparking and operator shocks. Sealed Construction IP66 construction allows the bar to be mounted in areas subject to occasional wash- down or spillage. If the bar does become wet it must be thoroughly dried before being powered-up. 5

Clean Pin Alert LED The local LED flashes constant green to indicate that the bar is on and working correctly. Red flashing LED shows that bar is dirty and needs cleaning. Solid red illumination indicates a fault with the high voltage output. Green constant OK Green flashing BarMaster remote programmer connected Red flashing - Cleaning required Red constant - Fault Clean Pin Alert and Fault Output An output signal indicates when the bar needs cleaning or when a fault has been detected. This signal is an open collector output and is available on Pin 2 of the M8 connector. 6

Divider The 924IPS is designed to operate in dirty, factory environments. To maximise the interval between cleaning the bar features a divider to increase the surface tracking distance between the two rows of high voltage pins. It is important to clean this area during cleaning operations. T-Slot The bar is mounted using the T-Slot at the rear of the bar. M4 T-bolts supplied with the bar maybe positioned to suit convenient mounting points. 7

Installation Mechanical Installation The 924 is a short to mid-range bar. Dependent on the application, the bar will be mounted between 20mm and 150mm from the target surface. The bar should be mounted securely, using all the M4 T-bolts provided with the bar. Correct positioning of the bar is vital for effective static control. There must be no metallic objects or obstruction between the bar and the material. The diagram shows the area that should be kept clear. Where x lengths are equal. 8

When installed at short range over a web or sheet, the bars must be positioned away from surfaces and rollers, as shown in the following diagrams. Your Meech distributor will be able to assist with questions regarding positioning of your equipment. 9

Electrical Installation WARNING The 924IPS requires a grounded 24V DC supply. The 0V line must be connected to ground. Failure to do so, will result in damage to the bar or the 24V supply. 220V AC Power Supply 24V DC 0V 924IPS Grounded 0V Connection to the 924IPS is via an industrial M8 4 Pin connector. With the following pin-outs: 2 4 1 3 4 2 3 1 Male connector on Bar Female connector on Cable Pin Colour Function Specification 1 Brown 24V (21-27V) 2 White Clean Pin Output Open collector output. V max =24V, I max =20mA 3 Blue 0V/ Ground 4 Black No connection 10

Connection using Meech 24V DC power supply The switchmode power supply has a standard IEC C5 mains socket and a 2000mm HT cable to M8 Connector. A break-out wire from the switchmode power supply provides the Clean Pin Alert output signal. Ensure The voltage supply is grounded to reduce the risk of damaging the 924 Connection using customer s own power supply: It is the customer s responsibility to check that either the 24V power supply they will be using is grounded. The 24V supply should be protected with a 1 Amp fuse. 11

Clean Pin Alert - Remote Monitoring Remote monitoring of the need to clean the bar is via the open collector output on the white wire on pin 2 Output External Alarm/Lamp/Relay 24V Max Output Extern Alarm/Lam Output OFF (= Green LED Flashing) Output ON (= Red LED F Output off Output on The open collector output has voltage and current limits of: V max = 24V I max = 20mA The open collector output can be normally open (NO) or normally closed (NC). This is selectable using a BarMaster remote programmer. The default is NO. NO: Output ON when the 924IPS is powered and requires cleaning or a fault is detected. Output OFF when the bar is not powered or when the bar is powered and OK. NC: Output ON when the 924IPS is powered and is OK. Output OFF when the bar is not powered or the bar is powered but requires cleaning or is faulty. Normally Opened Output Matrix Normally Closed Output Matrix 24V Power ON 24V Power OFF 24V Power ON 24V Power OFF OK (Green LED) OFF OFF OK (Green LED) ON OFF 12 Dirty/Faulty (Red LED) ON OFF Dirty/Faulty (Red LED) OFF OFF

Operation Having connected the M8 connector to the bar, power up the 24V supply and check for a green constant LED on the bar. This indicates that the bar is running correctly with a good ion output. Caution Always turn off the 24V supply before connecting or disconnecting the M8 connector. Failure to do so could result in stored charges giving a small electric shock. Setting the Rate The 924IPS features a variable output frequency. The frequency that should be set depends on the ionising product and the distance to the target object. Optimum Frequency Vs Operating Distance for 924IPS 25 20 Do not use closer than 20mm Frequency Rate (Hz) 15 10 5 0 15 30 45 60 75 90 105 120 135 150 Operating Distance (mm) Requires optional BarMaster Remote Programmer. 13

Maintenance Ionising bars become contaminated with usage. Dirt build-up on the body of the ioniser and, particularly on the pins, will cause a drop in performance. To get the best from your bar, it should be cleaned as part of regular machine maintenance. If regular cleaning is not carried out, the bar will detect the drop in performance and trigger the Clean Pin alert. The LED will flash red and the output signal will be activated. Before cleaning, ensure that the equipment is switched off. Emitter pins can be cleaned very effectively with a brush. A dry toothbrush is ideal. Make sure the central divider is also cleaned and the pin surface of the bar. Ionising bars will need periodic wiping to clean grey deposits from the surface of the bar. A cloth moistened with a small amount of IPA or methylated spirits is recommended. 14

Let dry for a minute and turn back on. Troubleshooting Solid Green LED In normal operation the LED on the bar will flash Green. This indicates that the bar is operating correctly with good ionisation performance. No LED Meaning No power to bar Action Check 24V Power Supply over pins 1 and 3. (Brown and Blue wires) Flashing Green LED Meaning BarMaster remote programmer is connected. Action After programming, reconnect directly to the power supply to resume normal operations. Flashing Red LED Likely cause Contamination causing a drop in performance. Action Switch off power supply and clean as described in Maintenance section. Turn power on and Check for Green flashing LED Solid Red LED Likely Cause Abnormal output current detected Action Check installation for metallic objects on the emitter pins Should the solid red LED persist, contact your Meech distributor. 15

Technical and Construction Dimensions (W x H) Maximum Length Operating Range Weight Construction Mounting 22.1mm x 31.2mm 3960mm 20mm 150mm 0.5kg/metre FR ABS T Slot with M4 x 20 studs Emitters Sharp titanium pins Input Current Max 500mA Input Voltage 24V DC (21-27VDC) Output Voltage +/- 7.5kV Pulsed DC Electrical Connection 4 Pole M8 Clean Pin Output Signal Open collector, V max = 24V; I max = 20mA Output Frequency Default Setting: 20Hz Adjustable with BarMaster from 1Hz to 20Hz; Output Balance Default Setting: 54%:46% Pos:Neg Adjustable with BarMaster from 80:20 to 20:80 Pos:Neg Environmental Protection IP66 Max Ambient Temperature 60 C CE Approval A CE Declaration of Conformity for this product exists in respect of the Low Voltage Directive:72/23/EEC ( LVD ) & Electromagnetic Compatibility Directive: 89/336/EEC ( EMCD ) Health and Safety 16 Emission of Ozone: Considerably below international standard of 0.1ppm.

COPYRIGHT MEECH STATIC ELIMINATORS THIS DOCUMENT AND THE INFORMATION THEREIN IS THE PROPERTY OF THE MEECH GROUP AND SHOULD NOT BE COPIED IN WHOLE OR PART OR USED FOR MANUFACTURE OR OTHERWISE DISCLOSED WITHOUT THE PRIOR WRITTEN CONSENT OF MEECH INTERNATIONAL Repairs And Warranty The Meech 924IPS Bar is warranted by Meech Static Eliminators Ltd. to the original purchaser against defects in material and workmanship for one year after purchase. Should any malfunction occur, please return the bar directly to Meech Static Eliminators Ltd. or your local Meech Distributor. All products returned to the factory MUST be accompanied by a return authorisation number and must be shipped prepaid. For prompt service, ship the unit to the factory with the return authorisation number shown clearly on the label. Be sure that it is well packed in a sturdy carton with shock absorbing material. Include a note stating the nature of the problem as specifically as possible, and also include instructions for returning the bar to you. We will pay one-way return shipping costs on any repairs covered under the warranty. Meech International 2 Network Point Range Road, Witney OX29 0YN, UK Tel: +44 (0) 1993 706700 Fax: +44 (0) 1993 776977 email: sales@meech.com web: www.meech.com TITLE: DRAWING No: MATERIAL: FINISH: Various TOLERANCE DIMENSIONS Machined Work Metric 0.2mm MM Unmachined Fabrications 2mm DO NOT SCALE Angular 0.2 PROJECTION Sheet 1:1 Date: Drawn by: 18/05/2015 David.Hyde REVISION: SHEET: 1 / 1 STATUS: Production

Meech International (UK) 2 Network Point Range Road, Witney OX29 0YN, UK Tel: +44 (0)1993 706700 Fax: +44 (0)1993 776977 email: sales@meech.com Meech Static Eliminators USA Inc 2915 Newpark Drive Norton, OH 44203 USA Tel: +1 330 564 2000 / 1 800 232 4210 Fax: +1 330 564 2005 email: info@meech.com Meech Elektrostatik SA Kaiserbaracke 66 B-4780 St.Vith Belgium Tel: +32 8086 2983 Fax: +32 8086 2821 email: mesa@meech.com Meech CE 2151 Fót Széchenyi út. 46 Hungary Tel: +36 27535075 Fax: +36 27535076 email: ce@meech.com Meech Static Eliminators (Shanghai) Co. Ltd 7G, 7F, LP Tower #25 Xiangfeng Road 201103 Shanghai China Tel: +86 400 820 0102 Fax: +86 21 6405 7736 email: china@meech.com Meech Shavotech Shavo House, Survey No.21A / 10 B, Plot No.394 South Main Road, Koregaon Park, PUNE 411 001 India Tel: 020-26069641/ 26069642, Fax: 020-26069644 e-mail: india@meech.com www.meech.com Meech Static Eliminators Ltd 2015 www.meech.com