Kjeldahl Method of Nitrogen Determination

Similar documents
behr Labor-Technik behrotest Equipment for the Determination of Crude Fibre

behr Labor-Technik Product Program

KJELDATHERM BLOCK-DIGESTION UNIT

KJELDATHERM BLOCK-DIGESTION UNIT

TURBOTHERM RAPID DIGESTION UNIT

THE IDEAL KJELDAHL SYSTEM FOR ANY NEED

TURBOTHERM RAPID DIGESTION UNIT

KJELDATHERM BLOCK DIGESTION UNIT

Product data sheet VAPODEST

Product data sheet VAPODEST 50s / 50s carousel

Product data sheet VAPODEST 50s / 50s carousel

Thermo Scientific Variomag Magnetic Stirrers

BIOSTAT D+ 100 MICROBIAL FERMENTER SYSTEM

Vapodest 30. Instruction Manual. Please read this instruction manual with care before you start operating the system

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Recirculating Coolers

PETRODIST PILODIST. Crude oil distillation systems according to ASTM - standards for fractionation and boiling analysis

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Vapodest 20. Instruction Manual. Please read this instruction manual with care before you start operating the system

Temperature multi-function calibrator Model CTM

RALF At a glance. Bioengineering RALF essentials. General

S OLENOID DIAPHRAGM DOSING PUMP GAMMA/ L FROM P ROM INENT. M ORE CONTROL, MORE DISPLAY, MORE APPLICATION VERSATILITY. NEW ROUTE.

FUTUR / FUTUR smart. Energy. Endurance. Performance.

COMPRESSOR SYSTEMS MADE IN GERMANY COMBI SCREW COMPRESSORS

Humidity Cabinet HYGROTHERM

ARTI Bileme GRINDING& WELDING MACHINERY

LAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C

S OLENOID DIAPHRAGM DOSING PUMP GAMMA/ L FROM P ROM INENT. M ORE CONTROL, MORE DISPLAY, MORE APPLICATION VERSATILITY. NEW ROUTE.

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions

SYNTHESIS OF BIODIESEL

MODULAR MELT FLOW: The First Step: Melt Flow Index (Weight Method) According to ASTM D 1238, ISO 1133 Method A and other equivalents

ceramus HiClass in dispensing.

EBA 270 Small centrifuge

Stirring Motors from CAT. Ingenieurbüro M. Zipperer GmbH. Our development makes your success. High power output up to 600 Ncm. Fuzzylogic control

640 KW / 800 KVA POWERED by

Operating manual. ph / mv controller type M8832N

Vapodest 20. Instruction Manual. Please read this instruction manual with care before you start operating the system

EuroDist System ScienDist TBP, Potstill, Combi

PNK-AC CNC CNC - HSS CIRCULAR SAWS GRINDING MACHINE

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

APPLICATION VAPODEST ALCOHOL IN BEVERAGES AND INTERMEDIATES

Product Range. Pages

trak systemizer Turnkey charging & changing stations

Pressure Boosting Systems Multiple-Pump Units

DIESEL Engine Fire Pump Controllers Features

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

7 Services Control and monitoring

INTELLIGENT FLANGE STRÖTER. Magnetic pulse generator

1000 KW / 1250 KVA POWERED by

Incubators. Incubators

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

GENERAL CATALOG L.TEX CORPORATON

Laboratory Roll Mills Type W 110 E / W 150 E Testing Roll Mills Type 110 P / W 150 P Automated Testing Roll Mills Type W 110 AP / W 150 AP

Dry Block Heaters designed

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Vessels and Distillation Equipment

Supercal 539 Universal compact heat meter

Inverter Resistance Welder/Horizontal Pressure Head NRW-IN8400A/NA-184 Now Available

BOHLENDER GmbH Phone: +49(0)9346 / Fax: +49(0)9346 / Internet:

PURe Mix Technology for Mixing and Metering

Nexa 1200 Fuel Cell System

A permanent supply in any environment today and in the future High performance power supplies fit for digitisation Let s connect.

REUSABLE PLASTICWARE LABORATORY PLASTICWARE 126 REUSABLE PLASTICWARE

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Produce it at a lower cost! TKA Ion exchangers!

Perfect Liquid Handling PRECISE RESULTS WITH INNOVATIVE TECHNOLOGY

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

EXPERTISE IN PLASTICS JERRYCANS

GRINDING & POLISHING FORCIPOL FORCIMAT

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

GEAR XP & VARIABLE XP

Hydraulic Power Packs

Pursuing high precision, speed, and ease of use

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Autonomous Power Supply Uninterruptible Power Supply (UPS)

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

The new generation of Brake Testers and Test Lanes: Safe and precise testing. For passenger cars and light commercial vehicles

EMISSIONS Analysis.

Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced

Future Driven EMISSIONS ANALYSIS. Innovative solutions for a cleaner and safer environment. MOT approved emission measurement systems

Corning Equipment Guide

GFS - New Charging Technology

SIRIUS Soft Starters Introduction

Elmasonic S Ultrasonic cleaning units. The sum of all possibilities

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

Biodiesel Fundamentals for High School Chemistry Classes. Laboratory 7: Using Differences in Solubility to Remove Contaminants from Biodiesel

INFASTAUB. Breathe The Difference: Pure Air. INFA-JET Pocket filter

ZINSSER-MINILAB A Complete Laboratory in a Case

Biodiesel Process Unit EBDB

Perfection in Liquid Handling PRECISE AND CONVENIENT PIPETTING

The Safest Heating Method!

POWER. ANYTIME. ANYWHERE. YOU GOT THE POWER. AIRPORT TECHNOLOGIES GROUND POWER UNITS

Various duties efficiently solved EMCOMAT E-300 E-360 E-400. [ means:

microtec 787/795 It can handle them all: The new truck wheel-balancing machines from Beissbarth. The Wheel Safety Expert.

Precise metering results!

Bedienungsanleitung Schüttler KM. Operating Instructions Shaker KM. Mode d emploi Agitateur KM KM 2 KM 2 AKKU KM CO 2 VERSION 04 / 2016

Solutions for the Lab. Centrifuges

LOCKED SERIES. Machine Failures. General Information. set up. maintenance. reconditioning. repair 30.4%

Transcription:

Kjeldahl Method of Nitrogen Determination N behr Labor-Technik

The behr programme for determining nitrogen in accordance with the Kjeldahl method The behr program for determining nitrogen in accordance with the Kjeldahl method offers the user individually configurable complete solutions for the laboratory. Digestion Units The digestion units for the behrotest InKjel model series are equipped with efficient infrared heating. The quality and positioning of the behr infrared heaters guarantee the user identical heating phases and digestion temperatures throughout all sample places. This also applies to the double-row arrangement in insertable stands for 12 samples. The direct sample heating by infrared heaters avoids the torturously long heating times of conventional heating block systems. This makes the behrotest InKjel the ideal rapid digestion system for determining nitrogen in accordance with the Kjeldahl method and other high temperature digestions. Steam distillation units behr steam distillation units from the S series are the optimum complement to the InKjel rapid digestion systems. Depending on the requirement, the user can choose between one manual and two automatic steam distillation units. These are identical in basic design but differ in terms of ease of operation and degree of automation. All behr steam distillation units have the following in common: high performance and speed suitability for practical use and user friendliness exemplary safety and reliability favourable cost-performance ratio Process suction system The two-stage behrosog process suction system precipitator plus safety backup stage ensures that the environment is not polluted by any of the acid vapours. Titration stations The behrotest manual titration station STI and also the automatic titrator provide reliable, safe and fast titration up to the conclusion of the nitrogen determination. Exemplary safety during water vapour distillation behr steam distillation units are not only efficient and reliable partners in everyday laboratory work; the user s safety was also an essential concern during the development and design of the devices. Therefore, all steam distillation units (S 1, S 3 and S 4) have a circuit breaker as a main power switch which is automatically activated in the event of overload and short circuit a mechanical pressure-relief safety valve to prevent too much pressure building up in the water vapour generator vessel monitoring (distillation can only take place if a vessel is inserted) a resettable excess temperature thermostat (in the event of insufficient water in the water vapour generator) cooling circuit monitoring by means of pressure switches temperature-controlled water vapour heating-up phase and pressure control by means of a solenoid valve The S 3 and S 4 steam distillation units also have automatic heating current monitoring of the water vapour generator

behr Steam Distillation Units behr steam distillation units from the S series are identical in basic design but differ in terms of ease of operation and degree of automation. The advantages of the behr steam distillation units User-friendly design S 3 and S 4: simple single button operation S 3 and S 4: menu guidance in many languages Automatic steam generator Pressure monitoring Automatic level monitor for the supply tanks Glass components for distillation mounted in full view behind transparent guard Automatic, time-controlled program flow (S 3 and S 4) Error diagnosis with visual (S 1, S 3, S 4) and acoustic indicators (S 3 and S 4) behr S 1 manual Steam distillation unit Standby function for low consumption of power and cooling water RS232 interface for data acquisition and control (S 3 and S 4) S 3 and S 4: Programming Takes no Time, Menu Guidance and Information at a Glance - in Your Own Language, too The behr steam distillation units S 3 and S 4 are extremely easy to program. You need only use one single button (rotary pulse encoder): Turn the button to move to the menu item and select by pressing the button. Set the parameters by turning and confirm by pressing the button. It couldn t be easier. We provide menus and information displays in almost every left-to-right scripts (Latin, Cyrillic, Greek etc.) and in your native language too. That guarantees greater safety and makes it easier for you to program and retrieve information.

behr S 1 Simple steam distillation unit for a small number of samples. NAOH is added and distillation started and ended at the touch of a button. Distillation time 2... 3 minutes. Including set of canisters for H 2 O and NAOH behr S 3 Semiautomatic steam distillation unit for a large number of samples. Choice of manual or automatic addition of H 2 O and NAOH. One distillation program. Automatic removal of sample residues by suction. Distillation time 2... 3 minutes. behr S 4 behr S 4 Automatic Steam distillation unit Fully automatic steam distillation unit for a large number of samples and difficult sample matrices. Choice of manual or automatic addition of H 2 O, NAOH and H 3 BO 3. Up to 99 distillation processes are freely programmable. Automatic removal of sample residues by suction. Distillation time 2... 3 minutes. The advantages of the behrotest set of canisters for steam distillation unit Hazardous material polyethylene canisters with UN approval Tubes routed through the screw cap i.e. no risky boring through the canister wall behrosog Process Suction System The two cleaning stages in the behrosog process suction system precipitator plus safety back-up stage ensure that the environment is not polluted by any of the acid vapours. The centrifugal suction washer in the compact process suction system extracts aggressive acid vapours during the digestion. Here an upstream series-connected two-stage precipitator washes out and separates the noxious contents. The behrosog is distinguished by its extremely favourable operating costs: power consumption 150 W/h water usage 30 l/h

Features S 1 S 3 S 4 Manual addition of H 2 O - + + Manual addition of NAOH + + + Manual addition of H 3 BO 3 - + + Automatic addition of H 2 O - + + Automatic addition of NAOH - + + Automatic addition of H 3 BO 3 - - + Programmable reaction time - + + Programmable distillation time - + + Automatic steam generation + + + Variable steam generating capacity (40% - 100%) - + + Automatic removal of sample residues by suction - + + Number of programs 0 1 99 Display language can be chosen by the user - + + Visual error reports + + + Acoustic error reports - + + Article no. Model Description Steam distillation units 804849001 S 1 Steam distillation unit manual operation, distilling time approx. 2-3 minutes 804849003 S 3 Steam distillation unit, partly automated, distilling time approx. 2-3 minutes 804849004 S 4 Steam distillation unit, fully-automatic, distilling time approx. 2-3 minutes 804849030 KAS 30 Set of canisters for S 3, consisting of 3 20-l canisters, including float switch 804849040 KAS 40 Set of canisters for S 4, consisting of 4 20-l canisters, including float switch Catalyst tablets for the Kjeldahl digestion 804840100 KT 1 Catalyst tablets (5.0 g K 2 SO 4 ; 0.5 g CuSO 4 ), tin with 1,000 pcs 804840101 KT 2 Catalyst tablets (5.0 g K 2 SO 4 ; 0.15 g CuSO 4 ; 0.15 g TiO 2 ), tin with 1,000 pcs Serial interface (RS232) - + + Standby operation between the distillations + + + Level monitoring for the set of canisters + + + Process Suction System Various behrotest digestion glassware types can be used + + + 804840000 behrosog Process suction system Technical data S 1 S 3 S 4 Nominal voltage: 230 V~, 50 Hz 230 V~, 50 Hz 230 V~, 50 Hz Power consumption: 1700 W 1700 W 1700 W Cooling water consumption: approx. 3 l/min approx. 3 l/min approx. 3 l/min Distillation time: approx. 2 to 3 min per sample approx. 2 to 3 min per sample approx. 2 to 3 min per sample Storage container: any size any size, recommendation: behrotest set of canisters Interface: - RS232 RS232 Display: - LCD LCD Programs: - 1 99 Dimensions (W x H x D in mm): 410 x 675 x 410 Weights: 32 kg 35 kg 35 kg

behrotest InKjel Infrared Rapid Digestion Units The basic units in the behrotest InKjel model series hold insertable frames for different combinations of vessels: 6 reaction vessels with 250 ml capacity in InKjel 625 (M or P) 12 reaction vessels with 250 ml capacity in InKjel 1225 (M or P) 4 reaction vessels with 500 ml capacity in InKjel 450 (M or P) 4 reaction vessels with 750 ml capacity in InKjel 475 (M or P) If required, the user can re-equip his system himself very easily with different digestion boxes (insertable frame with suction extraction apparatus) for other sample glassware. The behrosog process suction system is available to extract vapours during digestion. All InKjel systems are completely equipped with tiered console, suction system, insertable frame and digestion glass vessels. behrotest InKjel M: The Economical Solution The behrotest InKjel M series devices conform to the common basic concept in the InKjel series: The samples are heated directly by means of the infrared heaters. The basic unit can hold insertable frames for different combinations of vessels The energy for the behrotest InKjel M is regulated manually by means of a control dial on the device. The advantages of the InKjel M series are Fast direct sample heating with infrared heaters. Versatile applications: insertable frames for 250-ml, 500-ml and 750-ml reaction vessels With 500-ml and 750-ml vessels also suitable for determining nitrogen in water Simple re-equipment for different vessel sizes by replacing the digestion cassette (insertable frame with suction apparatus). Simple to operate. Very favourable price/performance ratio. Technical data Nominal voltage: Power: Dimensions (W x H x D): Weight: Energy setting range: 230 VAC/ 50 Hz 1500 W approx. 540 x 750 x 440 mm approx. 20 kg 0... 100 %, manual behrotest InKjel 625 M infrared digestion unit

behrotest InKjel P: The programmable solution The InKjel P s modern microprocessor control allows up to 99 digestion programs to be entered and stored. Each program can cover up to 10 energy/time combinations facilitating rapid and easy digestion even with difficult samples. A unique feature is the possibility of doubling the capacity of every InKjel P by connecting a corresponding InKjel PE expansion module. As the expansion module does not require any expensive control electronics, this is a particularly economic way to expand capacity. The InKjel P also offers: 99 storage spaces each with a maximum of 10 freely programmable energy/time combinations for difficult sample matrices. Simple and economical capacity doubling by connecting a PE expansion module. Technical data Nominal voltage: 230 VAC/ 50 Hz Power: 1500 W Dimensions (W x H x D): approx. 540 x 750 x 440 mm Weight: approx. 20 kg Programs: a maximum of 99 Time setting range: 0 199 min., in steps of 1 min Energy setting range: 0 100 %, in steps of 1% Programmable infrared digestion system behrotest InKjel 625 P Article no. Model Description 804849998 InKjel 625 M Manually variable infrared rapid digestion system for 6 glass vessels for 250 ml 804849999 InKjel 1225 M Manually variable infrared rapid digestion system for 12 glass vessels for 250 ml 804849450 InKjel 450 M Manually variable infrared rapid digestion system for 4 glass vessels for 500 ml 804849475 InKjel 475 M Manually variable infrared rapid digestion system for 4 glass vessels for 750 ml 804850001 InKjel 625 P Programmable infrared rapid digestion system for 6 glass vessels for 250 ml 804850002 InKjel 1225 P Programmable infrared rapid digestion system for 12 glass vessels for 250 ml 804850003 InKjel 450 P Programmable infrared rapid digestion system for 4 glass vessels for 500 ml 804850004 InKjel 475 P Programmable infrared rapid digestion system for 4 glass vessels for 750 ml 804849225 InKjel 1225 PE Expansion module without control for extending the InKjel 1225 P to 24-sample capacity, including insertable frame, suction system and reaction vessels P to 24-sample capacity, including insertable frame, suction system and reaction vessels 804849445 InKjel 450 PE Expansion module without control for extending the InKjel 450 P to 8-sample capacity, including insertable frame, suction system and reaction vessels P to 24-sample capacity, including insertable frame, suction system and reaction vessels 804849446 InKjel 475 PE Expansion module without control for extending the InKjel 475 P to 8-sample capacity, including insertable frame, suction system and reaction vessels P to 24-sample capacity, including insertable frame, suction system and reaction vessels

Titration: Manual or automatic For final titration when determining the nitrogen content, the user can choose at behr between manual and automatic titration systems. The STI manual titration station consists of a burette with digital display and magnetic stirrer with accurately fitting holder for the Erlenmeyer flask. A screen serves as a neutral background and allows the user to decide exactly on the colour change at the end of titration. The automatic titrator assures fast and simple titration: Shortly after pressing the start key, the user can read the result on the large display. 10 different titration methods including the Kjeldahl titration can be called up directly. The valve in the automatic titrator consists of highly resistant material, which is resistant to all known aqueous and non-aqueous titration solutions. The automatic titrator is complete with: titrator with metering attachment, titration tip, stand rod, titration tip holder, magnetic stirrers as well as ph combination electrodes and buffer set. Titration stations Article no. Model Description 742712848 TLE 230 Automatic Kjeldahl Titrator, 230 V 742712831 TLE 115 Automatic Kjeldahl Titrator, 115 V 804842020 STI Manual titration station for Kjeldahl nitrogen analysis Accessories for the Kjeldahl determination Article no. Model Description 804841015 SR 3i Round-bottom digestion vessel without standard ground joint for InKjel infrared digestion devices 804851051 KJ 500 Round-bottom digestion vessel, 500 ml, for InKjel 804851076 KJ 750 Round-bottom digestion vessel, 750 ml, for InKjel 804849983 EG 6 Insertable frame for 6 reaction vessels with 250 ml capacity in InKjel 625 804849984 EG 12 Insertable frame for 12 reaction vessels with 250 ml capacity in InKjel 1225 804849982 EG 4/500 Insertable frame for 4 reaction vessels with 500 ml capacity in InKjel 450 804849978 EG 4/750 Insertable frame for 4 reaction vessels with 750 ml capacity in InKjel 475 804849986 AE 6 Fume removal unit for InKjel 625 804849987 AE 12 Fume removal unit for InKjel 1225 804849985 AE 4 Fume removal unit for InKjel 450 and InKjel 475 behr Labor-Technik behr Labor-Technik GmbH Spangerstraße 8 D 40599 Düsseldorf Tel.: (+49) (0) 211 7 48 47 17 Fax: (+49) (0) 211 7 48 47 48 email: info@behr-labor.com Internet: www.behr-labor.com Subject to technical alterations. Errors and omissions excepted. 235006