NCPR DB INOX / NCPRI DB INOX

Similar documents
L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

40 Series - Miniature PCB relays A. Features

CAPACITIVE LEVEL CONTROLS SC - SCD SERIES

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Operating instructions Flow monitors SI5000 SI / / 2007

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

INSTRUMENTATION & CONTROL

Flow switches Series AD/VH

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Thermal flow sensor TFS-35

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Positive displacement batch controller

Thermal flow sensor TFS-35

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Compact System NRGS 11-2 NRGS Original Installation Instructions English

MXR-S-300 Series with 24V DC Input and 50kV Output

Pressure Transmitters

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

IEC Limit Switches Selection Guide

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

OPTISWITCH 4000/5000. Vibration level switches for liquids

Inductive conductivity meter

55 Series - Miniature General Purpose Relays 5-10 A

Electronic Circuit Breaker ESS20-0..

Insertion magnetic inductive flowmeter

Operating instructions Flow monitors SI / / 2010

General_technical_data Series

Steering column and sensor

Electronic timers CT-E range Selection and ordering details

RUC industrial relays of small dimensions

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Surface mounting, flush mounting, and DIN track mounting

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Electronic Pressure Switches

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Actuators for air dampers and control valves of oil burners

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

IEC Limit Switches Selection Guide

Safety Control HR1S-AC. Safety Relay HR1S-AC

2 pole 10 A PCB mount A1 A

Level switches Series LC40 Float level switch for liquids

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

5 mm contact pin pitch PCB or 95 series sockets

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Operating instructions Binary level sensor. LI214x /00 04/2016

CONTROLLERS & SPECIAL VALVES

Buchholz Relay MBP Gas and Oil Actuated Relay

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Suppression Technology Valve Suppressors - special function

CVR-625. Compact Vibrating Rod Instruction Manual

Switches- and Indicators

Product Data Sheet. Damper Interface. Features

Model Number Structure

Electromagnetic Flow Monitor magphant

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

Inductive Special Properties

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series


Rotary blade level indicators Level limit switches for bulk goods. Accessories

Electronic timers CT-S range Function diagrams

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Power Plugs for Proportional Valves (12 volt supply)

Inductive conductivity meter

Metal tube variable area flowmeter for gases, liquids and steam

English copy version 2010/REV04 PISTON PRESSURE SWITCH DS-117 / DS-112

Timer Relays - Fixed & Adjustable

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

Thermal Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

General_technical_data Series

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Electronic Ballast EVG 2000-T

General_technical_data Series

2/2 or 3/2 way direct acting rocker solenoid valve

Air Flow Controller M1compact Type-Summary FKM 130

Miniature Circuit Breaker

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Seal material. Pressure range. Pressure connection -40 F +212 F 1 -4 F +257 F 3

KD LV Motor Protection Relay

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

High-speed detection even a little liquid leak

Transcription:

1/5 NCPR DB INOX / NCPRI DB INOX CONDUCTIVE ELECTRODES WITH BUILTIN AMPLIFIER Operating principle Operating mode Level control for general application in conductive liquids with preferred use in conductive tanks (see other possibilities in page 5). The sensor uses the own process connection fitting as the common electrode and the rods for detecting the liquid contained into the tank where the level is to be controlled. The detection of that level provokes the action of a relay integrated into the sensor main body. A time can be set to delay the detection in tanks equiped with shakers or with turbulences. In order to adapt easily to the tank characteristics, it can be set the state of the contacts of the relay. It depends on the number of electrodes: With 1 electrode: Detection of 1 unique level point (amplifier KNPA). See page 2. With 2 electrodes: Detection to max/min levels (amplifier KNCA). See page 3. Sensor Process connection Electrode Electrode length Volt./Curr. in electrodes Process temperature Process pressure Electrodes insulation DIN flange. DN25. SS AISI316 (1.4401) SS AISI316 (1.4401). Rod ø5 mm. 1000 mm. 5 Vpp / 4 ma (in shortcircuit) 20..+70 ºC. For other temperatures, please consult. 5 Kg/cm 2 Adjustable between 1..100 K (1000 s..10 s) (See attached table). The models referenced NCPRI are supplied with a protective insulation of Poliolefine (PE) or to assure the detection in the set detection points. Sensibility ranges Main head Material and dimensions Housing protection Temperature Cable gland PBT. 64 x 95 x 110 mm IP67 20..+50 ºC M20 x 1,5 (IP68) 0 1 2 1 Detecting ( kohm) Undetecting ( kohm) 6 12 2 12 24 3 17 34 Output Type Response time Timing SPDT relay 6A/250V At power on: 800 ms At liquid detection: 500 ms Adjustable between 0..9 s. It can be set when detecting, undetecting or at whichever of both situations. 4 23 46 5 28 56 6 34 68 7 39 78 8 45 90 9 50 100 REFERENCE PROCESS CONNECTION SUPPLY VOLTAGE ELECTRODE 024 24 V NCPR Level sensor 048 48 V NCPRI Level sensor (electrode isolated) DB DIN flange I SS AISI316 P34 DN25 110 230 901 902 110..125 V 220..240 V 15..70 V/DC 60..240 V/DC 1 E 2 E 1 Electrode 2 Electrodes T L PE 1000 1000 mm To compose a reference, select one option of each column. Example: NCPR DBI P34 024 2E L1000

NCPR DB INOX 1 Electrode Control 1 level Startup and adjustment Prior to start working with the sensor NCPR, it must be adjusted for getting a right operation. Adjustments can be modified whenever required. It must be taken into account that the behaviour of the device can be different whether the adjustments are done while the electrodes are in touch or not with the liquid. Be sure that the options selector is right positioned. Each time that it is moved to a new option, the led flashes twice indicating that the option has been correctly reached. 2/5 Default values adjustment State of the relay contacts Timing type Time Run 5 1s The sensor is adjusted by default with values that can be used in a large number of applications. When pressing the pushbutton PROG the led turns on. Keep the pushbutton pressed until the led turns off (3 seconds), indicating that the default values have been reset (they are framed with at the left column). When accessing to this option, the led emits as many flashes as the adjusted sensitivity value, between 0 and 9. Each time the pushbutton PROG is pressed, the sensitivity value increases in 1, except when the value is 9 that moves to 0. If it is pressed longer than 3 seconds, the sensitivity value moves to 0. See the table ranges at the first page to relate each digit with its ohmic value. (Relay NO ( ): led OFF; Relay NC ( ): led ON). When accessing to this option, the led shows the actual state of the adjustment. Each time the pushbutton PROG is pressed, it is reversed the state of the relay contacts. WARNING: This option modifies the state of the relay and this could provoke undesired effects in the case that any device be connected to the contacts of the relay. (Detecting ( ): led OFF; Undetecting ( ): led OFF; Detecting and undetecting ( ): led flashing). When accessing to this option, the led shows the actual state of the adjustment. Each time the pushbutton PROG is pressed, it is moved to the next timing type in a cyclic way. When accessing to this option, the led emits as many flashes as the number of seconds adjusted in the timer, between 0 and 9 seconds. Each time the pushbutton PROG is pressed, the time value increases in 1 second, except when the value is 9 that moves to 0. If it is pressed longer than 3 seconds, the time value moves to 0. Normal operation mode. The state of the led matches with the state of the relay contact (led ON = relay ON). Assembly conditions Electrodes: The top screw acts as common electrode. This must be specially noted when assembling in fittings made with nonconductive material or when assembling at the bottom of the tank. The main electrode can be cut to reach the required detection height. During the cutting process, be careful in preserving the housing of mechanical stress that may damage the binding of the electrode with the electronic circuitry. Top assembly: control of the maximum level. Mounting position: The sensor can be mounted in any position. Remember the previous comments about the common electrode. Metallic or conductive tanks: When assembling the sensor to a conductive tank, the electrical conductivity between both elements must be kept. It can be used sealings composed by cooper, aluminium, etc. It is not recommended to use teflon tape. Nonconductive tanks: When assembling the sensor to a nonconductive tank, remember that the sensor will measure the conductivity between the main electrode and the flange. Side assembly: control of the level at whichever point of the tank. Handling: Do not hold the sensor by the housing while installing, do it by the flange. Once the screws have been placed to fit the flange, you can turn the housing 350º with your hand until it be placed in the right position. Electrical connection: Use a cable according with the load the relay will manage. It is convenient that the cable gland completely tight the cable of the electrical connection, and it becomes essential in the event of humidity or when installed outdoor. In these cases, make a loop in the cable to facilitate the removal of accumulated drops (see figure). Bottom assembly: control of minimum level.

NCPR DB INOX 2 Electrodes Max/Min level control Startup and adjustment Prior to start working with the sensor NCPR, it must be adjusted for getting a right operation. Adjustments can be modified whenever required. It must be taken into account that the behaviour of the device can be different whether the adjustments are done while the electrodes are in touch or not with the liquid. Be sure that the options selector is right positioned. Each time that it is moved to a new option, the led flashes twice indicating that the option has been correctly reached. 3/5 Default values adjustment State of the relay contacts Run 5 The sensor is adjusted by default with values that can be used in a large number of applications. When pressing the pushbutton PROG the led turns on. Keep the pushbutton pressed until the led turns off (3 seconds), indicating that the default values have been reset (they are framed with at the left column). When accessing to this option, the led emits as many flashes as the adjusted sensitivity value, between 0 and 9. Each time the pushbutton PROG is pressed, the sensitivity value increases in 1, except when the value is 9 that moves to 0. If it is pressed longer than 3 seconds, the sensitivity value moves to 0. See the table ranges at the first page to relate each digit with its ohmic value. (Relay NO ( ): led OFF; Relay NC ( ): led ON). When accessing to this option, the led shows the actual state of the adjustment. Each time the pushbutton PROG is pressed, it is reversed the state of the relay contacts. WARNING: This option modifies the state of the relay and this could provoke undesired effects in the case that any device be connected to the contacts of the relay. Normal operation mode. The state of the led matches with the state of the relay contact (led ON = relay ON). Assembly conditions Electrodes: The flange acts as common electrode. The electrodes for maximum and minimum level can be cut to reach the required detection height. It is not required to identify specifically the electrode for maximum or the one for minimum because the amplifier KNCA determine them by itself according to its height. During the cutting process, be careful in preserving the housing of mechanical stress that may damage the binding of the electrode with the electronic circuitry. Top assembly: max/min control. Mounting position: Preferably, assembly the sensor in vertical position. If it is assembled in the side of the tank, it is recommended to do it with an angle not higher than 45º as well as to use an electrodes separator to avoid the contact between them (consult the accessories in page 5). Metallic or conductive tanks: When assembling the sensor to a conductive tank, the electrical conductivity between both elements must be kept. It can be used sealings composed by cooper, aluminium, etc. It is not recommended to use teflon tape. Nonconductive tanks: When assembling the sensor to a nonconductive tank, remember that the sensor will measure the conductivity between the main electrode and the flange. Handling: Do not hold the sensor by the housing while installing, do it by the flange. Once the screws have been placed to fit the flange, you can turn the housing 350º with your hand until it be placed in the right position. MAX MIN Side assembly: use a separator NR.SEP (page 5) Electrical connection: Use a cable according with the load the relay will manage. It is convenient that the cable gland completely tight the cable of the electrical connection, and it becomes essential in the event of humidity or when installed outdoor. In these cases, make a loop in the cable to facilitate the removal of accumulated drops (see figure).

4/5 Example of wiring connection Operating diagrams Model NCPR DB INOX 1E NCPRI DB INOX 1E 1 Electrode Amplifier KNPA Simulation: Control of maximum level or filling Relay contacts: NC Timing type: Detecting and undetecting Time: Any value greater than 0 Simulation: Control of minimum level or emptying Relay contacts: NO Timing type: Detecting and undetecting Time: Any value greater than 0 Control of maximum level or filling control using a sensor with 1 electrode and the amplifier KNPA. (NC) NCPR DB INOX 2E NCPRI DB INOX 2E 2 Electrodes Amplifier KNCA Simulation: Control for filling Relay contacts: NC Simulation: Control for emptying Relay contacts: NO Filling control using a sensor with 2 electrodes and the amplifier KNCA. Installation examples Detection of maximum level Detection of liquid inside the pipes Detection of maximum and minimum level Detection of minimum level

KNCA KNPA 5/5 Output relay Resistive load DC Inductive load DC Mechanical life Max. mechanical operations Electrical life at full load Contact material Maximum voltage Operating voltage Volt. between changeovers Voltage between contacts Voltage coil/contact Distance coil/contact Isolation resistance 6 A / 250 V 0,2 A / 200 V 6 A / 24 V 3 A / 250 V 3 A / 24 V > 30 x 10 6 operations 72.000 operations / hour 360 operations / hour AgNi 0.15 400 V 400 V 1000 V 1000 V 4000 V 8 mm > 10 4 M Dimensions KNCA / KNPA Supply voltage Constructive and enviromanetal data Voltage phaseneutral Overvoltage category Shocking voltage Pollution degree Protection class Storing temperature Operating temperature Humidity Housing Socket Leds window Buttons and terminal blocks Terminals Norms Galvani isolation Frequency Operating margins Positive T: +34 934 330 370 F: +34 Protected 934 354 532 polarity 300 V I I I 4 kv 2 IP 20 50..+85ºC 20..+50ºC 30..85% HR Cycoloy Light Grey Lexan Light Grey Lexan Transparent Technyl Dark Blue Nickled brass Designed and manufactured under EEC standards. Directive for electromagnetic compatibility 2004/108/EEC. Directive for low voltage 2006/95/EEC. Plastics: UL 91 V0 KNCA / KNPA /DC 50 / 60 Hz ±10..15% Terminal A1 Insulation Accessories Colour External diameter (approx.) Temperature Models Material Colour Electrode diameter Electrodes protection against possible contacts among them. White 8 mm +140ºC NCVRI DB... T NR.SEP/P NR.SEP/T Electrodes separator PVC Red 5 mm Poliolefine PE Grey 7 mm +70ºC NCVRI DB... L White Segle XX, 91 E08032Barcelona Rev. 02/00 13/02/12 DISIBEINT reserves the right to alter the content of this document without previous notice T: +34 934 330 370 F: +34 934 354 532 www.disibeint.com disibeint@disibeint.com