Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

Similar documents
FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Acid Resistant AVC6000

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

2.6. Air Flow Control Valve Type PRD

Laboratory Room Controller

Air Flow Measurement Technologies

SLIM LINE FUME HOOD MONITOR

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Demand Based Static Pressure Reset Control for Laboratories

Laboratory Solutions. pricecriticalcontrols.com

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System

Element D Services Heating Ventilating and Air Conditioning ODG010107

Description. functions including single duct pressure dependent or pressure independent systems.

Accessories Standard Service Fixture Kits

Healthcare Solutions Room Pressure Monitors and Controls

Sierra 780S Series Flat-Trak Mass Flow Meter. Instruction Manual

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

Silver Series Thermal Dispersion Airflow Measurement Technology

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: University of Houston Project Name

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

COMPLETE and FULLY INTEGRATED AIR PRESSURE CONTROL & MONITORING SYSTEMS

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Installation & Operation Manual - Model AV3000

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

DIESEL Engine Fire Pump Controllers Features

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Supreme Air Fume Hood Option Availability

Appendix. Clearance. Skewed profiles. Application Schematics

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51)

Venturi Valve. 2 For more information visit v100. Actuator. Potentiometer. Lever Arm. Airflow Area AIRFLOW.

Warnings and Cautions. Precision Flow Insertion Mass Flow Meter. Instruction Manual BULLETIN F-41-PFS FR# R

2100 Turbine Flow Sensor

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Q&A FOR Webinar on Electrical Basics & Boiler Wiring

PowerView PV380-R2 Mechanical Configuration

Metasys Zoning Package Installation

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

STR Circular VAV Terminal Units

Positive displacement batch controller

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Laboratory Exhaust Air Terminal

SmartPak Welding Controller WK-MPS-16 Constant Current

BROCHURE. ABB drives for HVAC applications ACH550, 1 to 550 Hp

Element D Services Heating, Ventilating, and Air Conditioning

Installation, Service, and Troubleshooting Instructions

ICL Three Pump Controller

7 Services Control and monitoring

Element D Services Heating, Ventilating, and Air Conditioning

SECTION AIR TERMINAL UNITS

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

ZONE PRESENCE SENSOR FEATURES SPECIFICATIONS TABLE OF CONTENTS. VAV system using a Zone Presence Sensor.

Acid Resistant AVT6000

---:...-- Environmental Health & Safety RADIATION PROCEDURES MANUAL. Procedure Cover Sheet. Procedure Number: EHS REV 2

Fume Hood Contoller/Monitor. FHC/FHMX Series MANUAL INSTALLATION

SE8300 Series Installation Guide 24 Vac Low Voltage

PIM Pressure Independence Module

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Instruction manual. Smart Thermal Mass Flow Meter. TYPE : 3000S Series. ientek Co., Ltd.

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics

QUANTUM LX CONTROL PANEL

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Engineering Standards. Engineering Standard Number C A. Name. Digital Breathing Air Remaining System BREATHING AIR

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES

Illuminator Series CR NEMA 3R

RVS-DN Digital Reduced Voltage Motor Starter

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

F-2600 SERIES INLINE VORTEX FLOW METER

PIM Pressure Independent Module

Sierra Series 620S Boiler-Trak Insertion Mass Flow Meter

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

Start-Up, Operation and Service Instructions

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Variable Air Volume (VAV) Pressure Independent Control

F-1500 SERIES INSERTION TURBINE FLOW METER

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

MATRIX LLC LEVEL CONTROL PANEL

Model 1000 Vortex Meter

Air Pressure Sensing Switch with Adjustable Set Point Range. Dimensions in Inches (Millimeters)

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview. 11 or 14mm drive output (Option)

SECTION FLOW INSTRUMENTS

BAPI-Stat 3 Room Sensor

Model H30 Operation Manual

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Flow meter Type Recordall (RCDL)

Transcription:

TEK-AIR TECHNICAL PRODUCT DATA SHEET FVC2600 SASH SENSING VAV FUME HOOD SYSTEM MODEL 2600: Variable volume control based on sash position utilizes microprocessor based electronics and linear air control valve to monitor and control fume hood face velocity. Measures and maintains fume hood exhaust volume Ensures operator safety Conserves energy Improves fume hood performance User selectable control features Communicates with Building Automation System General Description The Model FVC2600 provides variable volume control based on sash position. Tek-Air's VorTek Airflow Traverse Probes provide volumetric measurement to provide airflow control. The basic system consists of the sash position sensors and transmitter, controller, VorTek duct airflow sensor, display unit, electronic to pneumatic converter, and PRD exhaust air control valve (see figure 1). The controller is typically wall-mounted above the fume hood. Sash position sensor strips are mounted inside the hood in close proximity to the sash. A factory-assembled PRD airflow control valve with Vortek probe, mounted in the duct, provides airflow control by measuring and modulating the volume of air being exhausted. A hand-held configuration tool is used to configure the controller operation. True Distributed Control The key word in industrial control is "distributed". The FVC2600 is a fully distributed microprocessor-based controller operating independently of other airflow and temperature controls in the lab. Each system is dedicated to the control of a single hood, providing control distribution for maximum operator safety. Speed While containment of gases in the fume hood is the chief goal of any fume hood control system, Tek-Air recognizes the need for fast, accurate response to changes in sash position and duct static pressure. The FVC2600 scans all inputs, performs control equations, and updates all output signals 5 times per second to eliminate control lag. Controller response to movement of the sash is virtually instantaneous. In one second from when the sash comes to rest, the airflow is modulated to within 90% of required airflow for the new sash position. In 3 seconds the airflow is stabilized within +/- 5% of the target airflow. In that 3 second period the FVC2600 controller updates the valve position more than 10 times. This speed of response has been proven to be much faster than that required to maintain containment on a well-performing fume hood. Application Operators and planners associated with laboratory facilities must focus on two concerns unique to that environment: fume hood operator safety and the high energy cost associated with discharging large volumes of exhaust air from fume hoods. Tek-Air Systems addresses these concerns with the FVC2600, representing the latest in fume hood control technology. The FVC2600 is a high performance controller capable of instant response to changes in sash opening and air handling systems. The FVC2600 is a true "closed loop" control system, utilizing actual fume hood exhaust airflow measurement with reset based on sash position measurement to provide speed and accuracy, which are key to ensuring worker safety and energy savings. Safety The FVC2600 provides both audible and visual alarms. Because tests have shown that toxic fumes can only be contained when hood control response is immediate, the FVC2600 has been designed to re-establish face velocity to OSHA limits within one to three seconds. Energy Conservation As the FVC2600 resets air volume in response to sash position changes, energy conservation is maximized by sash closure. Because the FVC2600 is capable of communicating digitally with central building monitoring systems, users who leave their sashes open can be identified. Further energy savings are possible with a nighttime face velocity setback feature using a communications link or by adding a simple dry contact into the controller digital input.

Principle of Operation The FVC2600 consists of the following basic elements: (see Fig. 1) 1. Sash position sensors and transmitter 2. Fume hood display 3. Controller 4. Electronic to pneumatic converter or actuator 5. Exhaust air control valve with VorTek airflow probes 6. Configuration tool (not shown) In simple terms, the VorTek airflow sensor in the fume hood exhaust duct measures and reports the airflow volume to the FVC2600 controller. The volume setpoint is set for both "occupied" and "unoccupied" status via a hand-held configuration tool. The appropriate setpoint is then selected, via a digital input, by the Building Automation System, a time clock lock or other switching system. The controller then modulates the exhaust valve, via the Electronic-to-Pneumatic Converter to maintain the proper airflow rate. To understand the FVC2600, one must look in greater detail to each of the elements of the system. The Sash Position Sensors (see figure 1) Variable Volume Control Based on Sash Position For safety reasons, many facilities require sash position monitoring and alarm capabilities. Because of its high speed-of-response, sash sensing provides safety protection for laboratory fume hood operators by minimizing both overshoot and undershoot of the exhaust air control valve. Tek-Air's sash sensing system consists of the SPT2600 Transmitter, and both vertical and horizontal sash position sensors, as required for each fume hood type. Vertical sensing is accomplished by a potentiometer with spring return that is rotated by a connecting cable attached to the sash, counterweight, or sash cable. The assembly can typically be mounted on top of the hood, outside the airstream, where it is not visible and is out of reach. The sash transmitter can accept up tp six vertical sash sensors. Horizontal sensing utilizes the "absolute position" sensing method. Each sash pane is equipped with a small magnet. A sensing strip is mounted to the sash frame and consists of a series of magnetically sensitive relays at one inch increments along the width of the strip. Each relay reports a position along the width of the sash. Where a sash magnet comes in proximity to the strip, the relay closest to the magnet is actuated, sending a binary position signal to a dedicated microprocessor serving the sensing strip. Using the location and width of each sash, the processor does the math to determine the open area of the horizontal sash panes. Each SPT2600 Transmitter receives signals from one horizontal sash sensing strip that is the full width of the hood opening, up to a 16' width. The strip can sense the position of any number of horizontal sashes. If sashes are not all equal in size on a given hood, consult factory for configuration of sensors. The transmitter outputs a 4-20 ma signal to the FVC2600 controller to indicate sash position. The controller immediately modulates the air valve control signal to adjust the airflow volume to the appropriate value. It can also be configured to generate an alarm if the sash is left open past a pre-set limit for a pre-determined time period. Figure 1 - Typical installation of FVC2600 with sash position sensing airflow control The Fume Hood Display (see figures 1 & 2) The FVC2600 display is normally mounted on the left or right front panel of the fume hood where it can best aid the operator in the safe operation of the hood. The display mounts on a standard 2" x 4" switch box installed behind the front panel. Simple Operation The display window and associated audio and visual alarm indicators instantly advise the operator when the face velocity is not within the desired high or low setpoints. LEDs and simple push button controls are easy to read and simple to operate. Normal conditions are indicated by an illuminated green LED and a 'norm' (normal) message displayed in the LCD window. Short periods of low face velocity, usually induced by moving the hood sash quickly, will cause the alarm indicator to blink and the digital display to show 'ALrt' (alert). If the alarm delay time is exceeded, the audible alarm will sound, the alarm LED will light, and 'Hi' or 'Lo' will be shown on the digital display, depending upon the alarm condition. The display window also indicates the face velocity in feet per minute (FPM). Setpoints for control, low alarms, and high alarms can also be selected for display using the 'Parameter' scroll button. All readings and settings are available for operator review via the display and keypads. Because accidents can occur within the hood, an emergency override button is provided on the display face. When pressed, automatic control of face velocity is suspended and the exhaust air valve is opened to provide for maximum exhaust volume, purging the hood.

Figure 2 - Fume Hood Display Face Audible Alarm Beeper Sounds when face velocity falls outside High or Low setpoints. Normal Green LED will be illuminated during safe (and alert) hood operation. Alarm Red LED will flash during an alarm condition until the Mute button has been pressed. Then it will become continuous. Mute Button Acknowledges alarm when pressed, silences audible alarm. Also used to perform self test. Numeric and Alpha Display Displays status and values. Emergency Red LED will illuminate after the Emergency button has been pushed. Emergency (Purge) Button Over-rides control and modulates exhaust air valve to max. volume. Pressing again returns to normal control. Parameters Button Scrolls through list of control parameters. The Controller (see figures 1, 3, & 4) Inputs Using industry-standard modular plugs and cable, the FVC2600 has a sash sensor input that allows interfacing with a variety of sensors designed for fume hood control. A direct input for the VorTek Airflow Probes enables the controller to measure and display exhaust volumes. Modular connection points are also provided for the configuration tool and the fume hood display. Outputs The FVC2600 utilizes an industry standard 4-20 milliamp analog output signal for modulating the final control device. It is compatible with most variable frequency drives, electronic to pneumatic converters, and electronic actuators. The controller uses a relay dry contact for alarm output. Both visual and audible alarms are activated when the actual face velocity is not within the desired high and low setpoints. The VorTek Airflow Probe (see figures 1 & 5) A key feature that sets the FVC2600 Fume Hood Control System is active airflow control with direct fume hood exhaust duct airflow measurement. The device used for airflow measurement is the VorTek Airflow Probe, which senses air velocity in the duct using vortex shedding technology. The VorTek probe has a long history of successful use throughout the world, in critical airflow control applications and in airstreams that are corrosive and carry particulate matter. Such demanding applications do not adversely effect the performance of the VorTek probes. The VorTek airflow measuring system consists of multi-sensor probes which are inserted in the ductwork between the fume hood and the air valve. VorTek sensing provides pulse type electronic out[ut signals which have a frequency that is directly proportional and linear to the airflow velocity. These digital pulses from each sensor are totalized in the FVC2600 controller, The controller is designed with an input for the VorTek probe that provides direct digital handling of the signals, eliminating the need for analog-to digital conversion. By providing true velocity averaging, exhaust volume is accurately measured and the value can be viewed using the configuration tool or the FVC display. Exhaust volume control is maintained by actively measuring the volume and controlling the air valve to insure that the desired airflow volume, based on sash position, is provided. FHT7000 Configuration Tool Research facility managers have individual preferences regarding fume hood control features. For this reason, the FHT7000 is designed to be user configurable. The user is able to modify the control mode, turn alarms off or on, adjust alarm setpoints, airflow and face velocity setpoints, and calibrate airflow and face velocity, to meet the ever changing needs of facility and staff. A password function is provided to protect against unauthorized tampering with the controller. FHT7000 The FHT7000 Configuration Tool is a hand held device used to configure the operation of the fume hood controller. The tool is menu driven, and incorporates a 4-line, 16-character per line, LCD window. The user can easily connect the tool to the fume hood display or directly to the controller. By removing the display face panel. The user can access the clearly marked modular receptacle on the circuit board. On ARCnet equipped units, a receptacle is provided on the bottom exterior of the display enclosure.

Setpoint and Configuration Adjustments Available: Password Hi Face Velocity Setpoint, Alarm Lo Face Velocity Setpoint, Alarm LoLo Face Velocity Setpoint Maximum Valve Opening Minimum Valve Closure Alarm Mute Control Alarm Latching Configuration Remote Reset Selection Remote Emergency Selection Minimum Exhaust CFM Maximum Exhaust CFM Communications Exhaust Volume Calibration Sash Type Vert. Sash Dimension, Width Vert. Sash Dimension, Height Horiz. Sash Dimension, Width Horiz. Sash Dimension, Height Set Vert. Sash Open Set Vert. Sash Closed Set Horiz. Sash Open Set Horiz. Sash Closed Sash Output, Realtime Face Velocity Calibration Dedicated Fume Hood Network Each FVC2600 controller is provided with a serial communications interface. This interface provides the ability to network up to 243 controllers to a central location. Information is available on the performance of each controller throughout the network. For a comprehensive list of control parameters that are available for the transfer to the Building Management System via communications, refer to the FVC2600 Installation and Operation Manual. Face velocity, airflow and alarm status parameters are "write" variables. Setpoints for alarms, airflow, and face velocity are "read/write". This capability also allows for remote setpoint reset from the BMS. Specifications FVC2600 Power... 24 VAC +/- 10%, 10 VA max. Display LCD... 4 1/2 Digit Dimensions... 5 in. x 3.125 in. x 1.5 in. Keypads... Mute, Parameters Emergency (purge) LED Indicators Normal... Green Alarm... Red Emergency (purge)... Red Face Velocity Range... 0 to 1000 fpm Resolution... 5 fpm Accuracy... +/- 5 fpm @ 100 fpm Low Alarm Setting... 0 to 500 fpm High Alarm Setting... 100 to 1000 cfm Alarm Delay... Adjustable, 5 to 30 seconds Airflow Volume Range... 0 to 5000 cfm Resolution...1 cfm Accuracy... +/- 1.5% Rate +/- 0.5% FS NOTE: Valve size will ultimately determine minimum fpm measurable. Outputs Control... 4-20 ma, 500 ohms max. Signal... 4-20 ma, 500 ohms max. (options: Face Velocity, Volume) Alarm... SPDT Relay, 0.5 amps max. Communications... RS-485, 2-wire Tek-Air Open Protocol; JCI Metasys N2 @ 9600 bps *ARCnet Protocol @ 625 kilobits/sec. * NOTE: Due to high speed, network requires low cap 12.5pF, 24 AWG shield type CMP (UL) 75C equal to Windy City #042002. Figure 3 - Controller Connection Diagram Figure 4 - Controller Mounting Detail

Figure 5 - PVP4000 PRD with Circular Inlet and Outlet, and VorTek VT4000 Sensor T - FVC26 FVC2600 Model Code To determine the length of the horizontal sash sensor strip required for your application, perform the following calculation and round UP to the closest size listed. Communications 1 - ARCnet (SmartLab) 2 - Open / N2 Vertical Sash Configuration 0 - No Vertical Sash 1-1 Vertical Sash 2-2 Vertical Sashes 3-3 Vertical Sashes 4-4 Vertical Sashes 5-5 Vertical Sashes 6-6 Vertical Sashes Length of Horizontal Sensor Strip 00 - No Horizontal Sensor Strip 25-25 inches 33-33 inches 41-41 inches 49-49 inches 57-57 inches 65-65 inches 73-73 inches 81-81 inches 89-89 inches Length of Horizontal Strip = L - W + 2 L = Length of Horizontal Sash Opening in Inches W = Width of On Panel in Inches Example: L = 48 inches and W = 12.5 inches Length of Strip Required = 48-12.5 + 2 = 37.5 Select 41 in Horizontal Sensor Strip L The FVC2600 provides VAV control based on sash position and airflow exhaust volume measurement. The basic system consists of a controller, display, and sash position sensors. A VorTek VT4000 airflow probe is also required and must be ordered separately. For fume hoods containing horizontal sash panels, magnets and mounting brackets are also required and must be ordered separately. You will need to provide the hood manufacturer, model #, quantity of panels and sash tracks to determine the magnet mounting requirements. W For combination type fume hoods, consult your local Tek-Air Regional Director before placing your order. Because combination type fume hood sashes are highly customized based on the end user specifications, it may be necessary to coordinate the mounting with the fume hood manufacturer. Tek-Air Sy stem's Horiz ontal ash S Sensor NOTE: The FVC2600 Model Code includes "Standard" sash configurations only. Any non-standard configurations shall be handled as special orders. The descriptions below define what Tek-Air considers "Standard" sash configurations. Standard Vertical Type Fume Hood Sash Configuration - For multiple vertical sashes, all sashes are assumed to be side-by-side and each sash is assumed to have the same dimensions. Maximum travel of sash from 100% open to 0% open is < 40". Standard Horizontal Type Fume Hood Sash Configuration - Horizontal sash panels are assumed to have the same dimensions and there is a minimum of two moving panels. Standard Combination Type Fume Hood Sash Configuration - The fume hood must contain only one vertical sash with horizontal panels contained within that vertical sash. Each horizontal panel is assumed to be the same dimension. NOTE: Consult your local Tek-Air representative for further information. ( for your local representative listing please visit our web site at www.tek-air.com ) All specifications are subject to change without notice.