Worry Free High Voltage Couplers WMEA Conference, San Antonio November 19, 2009 Presented by Nick Turner of KonNx Inc.

Similar documents
22kV 425 AMP KA STYLE COUPLER 224BKA - Range


PORCELAIN INSULATORS

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

MESG 12 / 17.5 / 24 / 36 KV

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

3EK7 Distribution Class Surge Arresters. Answers for energy.

3EK7 Distribution Class Surge Arresters. Answers for energy.

HIGH POWER RECTIFIER SYSTEMS

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

Gas Insulated Switchgear

Cobra-S. Catalog Cobra-S

FAQ S. Main Switchboard Design Criteria. ENGINEERED SOLUTIONS FOR ALL YOUR SWITCHBOARD NEEDS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Product Description: Objective and Certification: Test Samples and Test Cable:

3EK7 Medium Voltage Silicone Insulated Surge Arresters

LA Motor Protection. A South African Company to be Proud of

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

MEDIUM VOLTAGE SWITCHGEAR

15kV 200A Loadbreak Fuse Elbow Design Test Report. Report Number:

Eaton s Cooper Power Systems

Raising the bar. UHV switchgear and components

Geometric vs. Capacitive Stress Control: choosing cable termination accessories to help reduce electrical stress.

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Photo of NARM site here?

RAPIER DSB Disconnectors

B kv T&D GAS INSULATED SWITCHGEAR

ENYSTAR Load Centers up to 250 A

MINIATURE CIRCUIT BREAKER

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

Extensible Unit - VCE2a

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Solid Dielectric, Three Phase Reclosers CATALOG VS11

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

25kV 200A Loadbreak Bushing Insert and Elbow Design Test Report. Report Number:

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Restrained Plugs and Receptacles for South Africa

Metal enclosed capacitor banks: ABBACUS family

introducing the new macey range of waterproof and flameproof connectors for the oil & gas industry

Application Description

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK

Energy Division. PCA Single Column Polymeric Surge Arrester

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Key features. DESIGNS: - Conservator type - Hermetically sealed

MINIMISE THE RISK FROM YOUR HAZARDOUS WORKSITE

ASN3 ASN2 ASN1. ASN Series Medium voltage, metal-clad, air-insulated switchgear for primary distribution

Transformer bushings, type GOH. Technical guide

TECHNICAL SPECIFICATIONS OF PCC PANEL

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

Valid for you. medium voltage switchgear

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Panelboards for the S800 high performance MCB Mirage S800

This small footprint makes a BIG impact

the safe, reliable, and efficient choice for MV switchgear

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

SD Series Non-Fused Load Switches

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Selection Guide Motor Control Device Solutions

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

Outdoor vacuum breaker for railway applications - FSK II

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

cor Long Run Experience

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

"Accredited Test Laboratory" (ATL) means an organisation that is accredited by the South African National Accreditation System (SANAS).

DAQO Technical Differences of Isolated Phase Bus Standards. Study of Design Standard Variances, Insulator Design and Shipping Section Design

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Rail Mount Energy Meters. Ecolec 300 Rail Mount Energy Meters. Features. Applications. Approvals

Softstarter Intelligent Controllers

NXPLUS C Single busbar. Maintenance-free for lifetime

SOUTH AFRICAN NATIONAL STANDARD

INTRODUCTION HISTORY. Enfocus Software - Customer Support

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Adak Behin Niroo. co.com

SWITCHBOARDS (LV and MV)

FAST E R, A N D S A F E R

Unified requirements for systems with voltages above 1 kv up to 15 kv

STS SYSTEMS PRODUCT CATALOGUE.

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

Metal Clad Air Insulated Switchgear

REPORT OF TEST ON Elastimold Molded Vacuum Reclosers (MVRs)

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Transcription:

Worry Free High Voltage Couplers WMEA Conference, San Antonio November 19, 2009 Presented by Nick Turner of KonNx Inc.

KONNX KonNx Inc Office, Warehouse and North American Distribution Denver, Colorado AUSPROOF Headquarters, Factory, and Global Distribution in Gladstone, Queensland, Australia

KONNX Non-Ferrous Foundry Computer Network from Design to Manufacture CNC Equipped Machine Workshop

Basic raw materials received Final product totally manufactured and ready for use

The Development Of The KONNX Cable Coupler Systems

PERFORMANCE RECORD OF COUPLERS IN SERVICE 1 2 3 4 5 6

Goal: Engineer out all the ways a high voltage coupler can fail. What made them fail?

RESEARCHING COUPLERS GLOBELY Designs around the World

Initial Findings Low voltage High voltage Quick Fix Solutions i.e. Teflon Electrical Type Tests For Connector Lower Than Requirement For Cable (making coupler weak link)

THE ULTIMATE TEST SHORT

AIR AND PARTIAL DISCHARGE Air Trapped Inside Coupler Enclosure Phase To Phase Flashover Existing couplers tested with results exceeding 20,000 pico-coulombs (pc). Extruded mining cable specifications call for an average 5 pico-coulombs. AIR PARTIAL DISCHARGE

SOLUTIONS Remove Air with Silicon Rubber Insert Insulating Material Developed to Extinguish Tracking Insulating Material Silicon Insert

NO TRIPS OR ANY SIGNS OF FAULT

ANALYSIS Silicon Rubber Insulating Material Stepping Stone

PHASE SEGREGATION BY EARTH Mining Industry Standard EARTH PHASE PHASE PHASE EARTH EARTH EARTH

FIRST SOLUTION A Phase to Ground Fault was created with conductive paint Earth Star Placed Between Phases A Through Fault Test was then performed on this solution to see how it would perform in the field

REASON FOR FAILURE PHASE 1 EARTH PHASE 2 PHASE 3

FINDING A SUCCESSFUL SOLUTION Equipotential Lines Good Equipotential Lines Good. Earth Star Equipotential Lines Crushed Up Individually Screened Cable

COUPLERS HOMOGENEOUS WITH CABLE EARTH CROSS SECTION ALL TYPE TESTS PERFORMED WERE WITHIN CABLE SPECIFICATIONS

Current Contacts are of an eight finger design. Heat treated locking ring to maintain contact pressure. Continuous rating of 800A TYPE TESTS PERFORMED ON NEW DESIGN Temperature Rise at 800A Through Fault Test: 20kA for 0.3 sec 20kA for 0.3 sec 20kA for 1.0 sec Passed Passed Passed Passed

Voltage Type Tests Passed Impulse Voltage 125kV 10 Pos. Shots and 10 Neg. Shots A/C High Voltage Withstand 50kV for 1 min 35kV for 6 hours Partial Discharge 10pC Prior to 6 hour high voltage withstand 0.6pC After 6 hour high voltage withstand

Comparison Coupler Now As Good As The Cable

From Partial Solution to the Complete Solution

Water Ingression Existing round O-ring seal Square section silicon face seals with a life of 30 yrs Tested to IP 68 Standard IEC 60529 Cable Glands KonNx gland incorporates adjustments to maintain tension on cable over time. Design will tighten on cable if tension on cable is applied. Glands are design specifically for cable sizes.

Special Cold Pour Developed with 3M

Bi-Sexual Design All male couplers. Guide pins assist alignment. All Silicon 800amp female/female Phase connectors w/rockwell hardened lock rings MSHA Compliance.

Enclosed slide hammers. Earth pilot attachment. Coupling tool. Tools & Coupling After together use four bolts to secure

Integrated Handling System For Surface Mining Applications Assists with opening and closing couplers One man operation Able to relocate couplers while energized. Protection for the joint. Roll-over. Skid wear pads. Cable clamp at each end. No tools required

Research & Development 5% of annual income Latest Development is integrated Fiber Optics Benefits to the Mining Industry Eliminating risk of phase to phase faults. Reducing the risk of phase to ground faults Fully integrated handling systems. Couplers do not limit the power supply to machines (All couplers continuously rated at 800 amps) Eliminates need for male/female cable orientation We listen to our customers and keep improving our products Increase in expected life of coupler. Over 1000 of our couplers in service since 1992 with no problems

Track Record 25kV couplers operating in Australian mines since 1992. In excess of 2000 couplers in Australia, South Africa, South America, North America and Asia Specified 25kV coupler by BHP Billiton. Rio Tinto. Xstrata Coal. Anglo American Coal Arch Minerals Cline Resources Signal Peak Energy

Track Record Specified 15kv Couplers by: GCC Energy Prairie States Energy Project ICG Consol Energy Specified 8kV Couplers by: BHP San Juan Mine Arch Minerals Signal Peak Energy Patriot Coal FMC Chemicals

KonNx