Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries

Similar documents
Industries. Septic Tanks

PRODUCT DESCRIPTION 1500 RECT 2/C Gallon 2 Compartment Septic Tank TOP VIEW. Rectangular lid has optional

RELN Septic & Holding Tanks

HYDRA-CELL PIT SYSTEM KNOCK-OUT PIT

CATALOGUE SEWAGE MANHOLES

Hynds Telco and Electrical Pit System

The Pump Matic Range

13-17 Endurance Avenue Queanbeyan NSW 2620 Ph: Fax:

GB-250. Submittal Specifications Installation Application Specific Details

Draincoil. Features & Benefits. Draincoil corrugated drainage pipe is of a consistent high quality and comes in a broad range of sizes and grades.

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines

At last, a Green Alternative to rubber, concrete and steel wheel stops!

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

INSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents

Drain Waste & Vent (DWV) Systems SCJ PIPE & FITTINGS FOR NON-PRESSURE SEWERAGE APPLICATIONS

INSTALLATION GUIDE. Model #GB1 20/25 GPM Grease Interceptor For Indoor Use. Contents

Domestic Traditional Pits DOMESTIC TRADITONAL PITS

INFRASTRUCTURE DESIGN STANDARDS FIGURES SECTION 2 SANITARY SEWER COLLECTION SYSTEMS

TANKS Pages INDEX CARTAGE & WATER TANKS MODULAR TANKS SPRAY TANKS DRUM RINSE BINS 73 ACCESSORIES 74 BALL BAFFLES 75-76

Heavy Duty Commercial Pits

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

Septic Tank. Installation Guidelines

GB2 35/50 GPM Grease Interceptor for Indoor Use

all pump solutions Pumps & packaged pumpstations

Infrastructure & Power. FP M c Cann. Tel: +44(0) Fax: +44(0)

Aqua Green Utility Inc.

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

POWER & INFRASTRUCTURE SOLUTIONS

GAMMA Septic Tanks Installation & Operation Guidelines

DURISOL ANCHORED RETAINING WALL SYSTEM (DARWS)

Rain Harvesting Pty Ltd

Reinforced edge channels KE-100

Trade Product Catalogue. Home Sewage Treatment Systems Concrete Rainwater Tanks Plastic Rainwater Tanks

infrastructure rotational moulding catalogue vrm - innovation for tomorrow edition iii

Road + Civils AG.UK.COM

SEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version

CableMaster 800. Gas Technology Systems. For Electrical & Plumbing Contractors

Main Toll Free Range Road 73, Parkland County, Alberta T0E 0S0

The Sika Solution x 600 x 700H / 900H. Class D. Roadway Installation Guidelines p 9-11

SOLFLO MAX LINEAR COLLECTION Linear catch basin connected with double bell outlet with integrated gasket and clips (DBIGC)

Tank Wall Installation Procedure

RAINWATER HARVESTING SYSTEMS

Bid Summary Still Creek Wastewater Improvements Phase III City Job No. 411-D November 21, 2013

Aluminum Box Culverts

MIDLAND PRECAST COMPANY, L.C. Tel: Hwy 14 PO Box 63 Toll Free: Corydon, Iowa Fax:

Uniclass L L2123 EPIC J3413. CI/SfB (52.5) If9. Surface drainage for heavy duty traffic applications ACO RoadDrain

GRAF EcoBloc Stormwater Management System

Floor boxes... choice, flexibility and easy installation

ZONE 09FENCING SECTION

cavity floor service outlet boxes

WATER & WASTE management 2015 edition

MANHOLE INDEX INDEX CONCRETE MANHOLE SPECIFICATIONS ASTM SPECIFICATIONS

IP65/IP66 ABS/Polycarbonate Screw Lid Boxes

power & infrastructure solutions power and infrastructure brochure

TWIN WIRE ARC SPRAY SYSTEM, MODEL: ARCJET -99/600

Installation and maintenance instructions for the GRAF Universal External and internal Filter 3

Water Supply and Sewerage Approved Products Manual - February 2006

GRAF EcoBloc Stormwater Management System

ABS lifting station Synconta

Lifting Station Type ABS Synconta 900B

Domestic Septic Systems

irst flush water diverters

Steel Products. 8M Series

CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE. Ideal for all Agricultural applications.

SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS

MARINE SPILL RESPONSE The oceans cover 71 percent of the earth s surface and contain 97 percent of the earth's water.

Aim higher. Soil & Waste System

NOTE: Please ask James Hardie on for delivery timeframes and terms and conditions. STORMWATER PIPES & FITTINGS

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

Petrol & Oil Interceptor

Table of Contents. Item Page #

REFUSE & MAINTENANCE

2018 CATALOGUE CONCRETE PITS COVERS & GRATES ...& A WEALTH OF KNOWLEDGE. Phone:

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

Project Book Worksheet for Cost Estimation

PRECAST CONCRETE SPECIALISTS. Product Catalogue

ACO Water Management: Civils + Infrastructure

Specifier s Document. Features and Benefits. Construction

Septic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks

Add 7% to cater for any fittings/fabrication at the bridge, and anchor blocks (as directed by the Eng. On site) Total

Installation instructions and maintenance for the Graf MINIMAX -Filter internal and external

TRANSPORT & 4WD EQUIPMENT

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

Vanguard Road Plate. Modular trench cover system to allow passage by traffic and pedestrians during road works. Product operating parameters:

American Flow control

COMAX REINFORCEMENT CONTINUITY STRIP

INSTALLATION GUIDELINES

Installation, Operations & Maintenance

ABCD BFDC BEDA AB CDEFCC

19 - Boat Seats - Tinnie / Runabout

HANDHOLE UNIT. WEB: PHONE: FAX:

It s a matter of honour to access your construction site. Junttan piling hammers

UTILITY CROSSING DETAIL

Pumps. Everything flows quickly and efficiently. The pump program from Wacker Neuson.

Cable Connectors & Conduit Sealing Bushings

Commercial Sized Drainage

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

PRODUCT CATALOGUE - SPILL KITS

PRODUCT MANUAL TRENCH ADAPTER

Overfill Prevention Valve

Transcription:

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Engineer-designed and built from fine tolerance steel moulds Tanks are made from 40 MPa concrete to give additional strength and durability Internally, all joints are sealed, reducing the potential for leakages Tanks are offered in 14 different sizes, for maximum flexibility Child-proof and vandal-proof lids on our septic tanks give you additional peace of mind. Industries 1

Septic tanks Ri-Industries have over 60 years experience in the septic tank business and have developed efficient manufacturing techniques to produce septic tanks of the highest quality that are built to last. All tanks are engineer-designed and built from fine tolerance steel moulds which produce reliable wall thickness Tanks are made from 40 MPa concrete to give additional strength and durability Internally, all joints are sealed, reducing the potential for leakages Septic Tanks are offered in 14 different sizes, for maximum flexibility Child-proof and vandal-proof lids General information Installation and design of septic systems are regulated by the Health Department in each state. Local Council Health Inspectors will have relevant area specific information. To keep the septic tank fresh and operating correctly: For an average family of 4-6 people the septic tank may need to be de-sludged approximately every 4 years or as per Council requirements. Material that will not break down such as plastic bags, tampons, disposable nappies, condoms, etc, must NOT be put into the septic system. Biodegradable products should be used wherever possible. The bacterial action of septic tanks can also be severely inhibited by excessive amounts of disinfectants or old medicine entering the tank. Only use products approved for use in septic systems. Pooling of effluent near the seepage trench indicates that the system may be clogging. If this occurs contact your local liquid waste disposal contractor to empty the system. More detailed information on the workings of septic systems are available from the South Australian Health Commission. 2

Septic tank 560 litre Holding tank 640 litre 560 litre septic tank 840kg 640 litre holding tank 760kg Increment (optional) - 200 mm & 450 mm Note: Holding tank has no baffle, outlet end tunnel is for lifting purposes only. 3

Septic tank 1,620 litre Holding tank 1,650 litre 1,620 litre septic tank 1,875kg 1,650 litre holding tank 1,730kg Note: Holding tank has no baffle, outlet end tunnel is for lifting purposes only. 4

Septic tank 3,000 litre, 50mm wall 3,000 litre septic tank (50mm wall) 2,000kg 5

Septic tank 3,000 litre, 60mm wall Holding tank 3,000 litre, 60mm wall 3,000 litre septic tank (60mm wall) 2,300kg 3,000 litre holding tank (60mm wall) 2,070kg Note: Holding tank has no baffle, outlet end tunnel is for lifting purposes only. 6

Septic tank 3,250 litre Holding tank 3,250 litre 3,250 litre septic tank 2,140kg 3,250 litre holding tank 1,950kg 1.3T Note: Holding tank has no baffle, outlet end tunnel is for lifting purposes only. 7

Ri-Scape tank 3,300 litre with 900L pump chamber 3,300 litre Ri-Scape tank 3,200kg Septic tank outlet filter 3mm punched apertures meets Standard AS1547:2012 Cover slab with lightweight, lockable poly resin access lid Saddle riser 475mm with core holes 1.3T 700mm 1160mm Cover slab 100mm DN 100 PVC IP opening Saddle riser Septic tank outlet filter Core DN 50 hole for pump out DN 100 PVC socket Min. air space 220mm DN 100 PVC socket 1550mm 2 x 150mm transfer ports in baffle 1770mm 900L pump out chamber Pump by others 2300mm 100mm deep x 300mm concrete plynth for pump support 8

Ri-Scape tank 4,000 litre with 900L pump chamber 4,000 litre Ri-Scape tank 3,700kg Septic tank outlet filter 3mm punched apertures meets Standard AS1547:2012 Cover slab with lightweight, lockable poly resin access lid Saddle riser 495mm with core holes 1.3T 700mm 1160mm Cover slab 100mm DN 100 PVC IP opening Saddle riser Septic tank outlet filter Core DN 50 hole for pump out DN 100 PVC socket Min. air space 220mm DN 100 PVC socket 1630mm 2 x 150mm transfer ports in baffle 60mm thick 500mm 90mm thick 425mm 90mm thick 1950mm 900L pump out chamber Pump by others 2300mm 100mm deep x 300mm concrete plynth for pump support 9

Septic tank 4,300 litre Holding tank 4,300 litre 4,300 litre septic tank 2,550kg 4,300 litre holding tank 2,200kg 1.3T Note: Holding tank has no baffle, outlet end tunnel is for lifting purposes only. 10

Septic tank 5,000 litre Holding tank 5,000 litre 5,000 litre septic tank 3,000kg 5,000 litre holding tank 2,700kg 2 x 1.3T Swiftlift anchors at each end for lifting Note: Holding tank has no baffle, outlet end tunnel is for lifting purposes only. 11

Vertical septic tank 5,000 litre 5,000 litre vertical septic tank 4,600kg 800 dia pipe increments available 600 mm and 300 mm high to raise access openings to finished surface level. 600 dia covers available in heavy duty and light duty application. 150 mm thick coverslab with inspection and access openings 2240mm 2070mm 2020mm 125 mm base 12

Vertical septic tank & trafficable lid 5,000 litre 5,000 litre vertical septic tank 5,350kg 800 dia pipe increments available 600 mm and 300 mm high to raise access openings to finished surface level. 600 dia covers available in heavy duty and light duty application. 250 mm thick coverslab with inspection and access openings 2240mm 2070mm 2020mm 125 mm base 13

Vertical holding tank 5,000 litre 5,000 litre vertical holding tank 4,020kg 800 dia pipe increments available 600 mm and 300 mm high to raise access openings to finished surface level. 600 dia covers available in heavy duty and light duty application. 150 mm thick coverslab with inspection and access openings 2240mm 2000mm 125 mm base 14

Septic tank & lid 8,000 litre 8,000 litre vertical septic tank 6,310kg 900 dia pipe increments available up to 1200 mm high to raise access openings to finished surface level. 600 dia covers available in heavy duty and light duty application. 150 mm thick coverslab with inspection and access openings 2460mm 2250mm 15

Vertical holding tank 8,000 litre 8,000 litre vertical holding tank 5,670kg Inlet position 2180mm (280mm from top) 2460mm 2250mm 16

Septic tank & trafficable lid 8,000 litre 8,000 litre vertical septic tank 7,460kg 2460mm 2250mm 17

Septic tank & lid 12,000 litre 12,000 litre vertical septic tank 8,420kg Inlet position 2250mm (190mm from top) Outlet position 2200mm (240mm from top) 2440mm 2250mm 18

Septic tank & trafficable lid 12,000 litre 12,000 litre vertical septic tank 9,840kg 2440mm 2250mm 19

Vertical holding tank 12,000 litre 12,000 litre vertical holding tank 7,300kg Inlet position 2180mm (260mm from top) 2440mm 2250mm 20

Septic tank & lid 20,000 litre 20,000 litre vertical septic tank 12,510kg Inlet position 2550mm (190mm from top) Outlet position 2500mm (240mm from top) 2740mm 2550mm 125 mm base 21

Septic tank & trafficable lid 20,000 litre 20,000 litre vertical septic tank 14,620kg Inlet position 2550mm (190mm from top) Outlet position 2500mm (240mm from top) 2740mm 2550mm 125 mm base 22

Vertical holding tank 20,000 litre 20,000 litre vertical holding tank 10,600kg Inlet position 2480mm (260mm from top) 2740mm 2550mm 125 mm base 23

Saddle risers, increments & coverslabs To suit all horizontal septic and holding tanks Coverslabs suitable for pedestrian traffic only Radius of saddle riser varies to suit tank Each component fitted with 1.3t Swiftlift anchors for lifting TYPE 34 Suitable for 640 litre ad 560 litre tanks only. TYPE 33 Suitable for all other horizontal tanks. Weight 192kg Weight 100kg 200mm - weight 96kg 450mm - weight 268kg 200mm - weight 86kg 300mm - weight 124kg 400mm - weight 166kg 450 - weight 188kg 370mm - weight 360kg 250mm - weight 235kg 450mm - weight 320kg 475mm (4,300 litre) - weight 320kg 495mm (5,000 litre) - weight 335kg 24

Glass reinforced concrete lightweight slabs & risers Specifically designed to be used in difficult or existing areas where truck access is not available to lift normal concrete products Suitable for pedestrian traffic only Slab lid in normal concrete to suit weight GRC saddle and riser (2 part lid) - Approx weight 50kg each - Can be lifted with 1.3 tonne Swiftlift claws 600mm 810mm Glass reinforced concrete lightweight extension riser for saddles - Approx weight 60kg - Sizes for extensions 290mm and 380mm - Actual 400mm and 310mm with rebate of 20mm - Suitable for 1,620, 3,000 and 3,250 litre septic tanks 1,235mm 835mm 730mm 1,125mm 290mm or 380mm Glass reinforced concrete lightweight saddle riser - Approx weight 56kg 1,235mm 830mm 725mm 1,125mm 300mm 25

ATSIC coverslab 3,000 litre septic tank Class B - light duty unit for use in areas accessible only by cars and light 4WD vehicles with a gross maximum mass of 2670kg Designed to span across the saddle riser bearing onto the ground each side of it Septic tank coverslab 1,700kg 600mm dia light duty cast iron cover and frame 150mm inspection openings The ATSIC coverslab must not come into contact with the saddle riser ELEVATION The compressible foam gasket must be installed into the top rebate of the saddle riser to ensure that forces are not transferred directly onto the septic tank 26

Small ATSIC coverslab 3,000 litre septic tank Precast concrete saddle riser coverslab with 600mm dia cast iron Class B light duty cover Designed to suit 250mm and 400mm high saddle risers and increments There is width overlap on saddles and width and length overlap on the increment - cover is rebated to suit either saddle or increment Septic tank coverslab 340kg 600mm 900mm 150mm 1270mm 27

Precast pump chamber 622 litre 622 litre precast pump chamber 1,264kg 1.3 tonne lifters 750mm 1250mm SECTION plastic fibre PIT PLAN 1230mm 220mm 1140mm 1370mm 1450mm 75mm 545mm 690mm 1010mm 1160mm 28

Precast pump chamber 1,100 litre Constructed using concrete with plastic fibre 1,100 litre precast pump chamber 1790kg LID All holes are knockout only with the exception of the inlet 500mm 100mm inlet 1000mm 2 PART CONCRETE LID 1500mm 1000mm KO 1000mm 1100mm KO on 3 sides 900mm Inlet 800mm 860mm 1500mm 825mm 100mm 29 100mm

Distribution box Precast reinforced concrete box fitted with 100mm diam PVC inlet and outlet collars Box and increments fitted with Swiftlift anchors for lifting Approved by the SA Health Commission Distribution box with lid Lid only 150kg 35kg 1.3T lifters Increment 200mm - 65kg 300mm - 95kg 400mm - 125kg 30

Polytrench plastic effluent trench The plumber s choice for septic tank or stormwater drainage in unserviced areas A simple, economical and fast way to lay effluent trench Premium grade high density polypropylene with UV filter injected to give high impact strength Lapping joint Specially designed slots on either side allow the water to penetrate into the surroundings but retain the settled sludge within the Polytrench, ensuring longer life End caps available General installation information Check with your relevant Health Department before starting to lay Polytrench. 1 On a level contour excavate a trench to the required length, 1,200mm wide and to the required depth below the end of the septic tank outlet pipe. Ensure that the trench bottom is level. 2 Lay the interconnecting units centrally in the excavation (fit moulded end caps to the end of each run). 3 Connect the tank outlet pipe into the top of the first piece of Polytrench. 4 Backfill with 40mm aggregate to the top of the Polytrench ensuring that there are 300mm of aggregate on either side of the units. 5 Cover the aggregate and the Polytrench with trench fabric/geotextile. 6 Backfill with suitable material. Specifications Our Polytrench has interlocking sections, supplied in manageable lengths: Length - 1,000mm Height - 330mm Width - 450mm geotextile fabric 40mm aggregate 231

PVC effluent diverter junction Cost effective: no extra fittings for line up or I.O. Light weight: no sagging lines Standard 45 degree Y size and style for quick, easy installation The correct operation is visible after installation Riser and switching lever easily cut to suit depth of job Available with left and right hand diversion Riser and cap supplied by others 232

Induct vents Induct vent base complete 386kg 33

Swiftlift lifting system The Swiftlift concrete lifting system provides a simple, safe and rapid method of lifting and handling precast concrete elements. Originally developed to overcome the need to use time consuming and potentially dangerous threaded connectors, the system has been extensively used throughout the world for more than ten years and has proved its versatility, operational simplicity and safety in a wide range of applications. Full approval has been granted for the use of this system by the regulatory authorities in every state of Australia and new Zealand. The system uses forged steel anchors which are normally hot dipped galvanised. Each anchor has its capacity, in tonnes, clearly marked on the head to ensure maximum safety on site. A specially designed lifting eye is connected to the head of the embedded anchor. The lifting eyes are designed so that, when properly connected, they cannot release whilst the system is under load. On completion of the lift, the eye is simply disengaged and, where required, the recess is grouted over. The Swiftlift lifting system is standard in all Ri products and the lifting eyes may be purchased from our office. Available in 1.3, 2.5, 5.0 and 10 tonnes. 34

Lifting septic tanks 3,000-5,000 litre The use of unapproved lifting equipment may damage or crack tanks. The diagram shown below is the correct method for lifting a Ri 560-5,000 litre horizontal cylindrical type septic tank. Where Swiftlift anchors are fitted, these may be used for lifting with an appropriate lifting eye. 35