Temperature Switches

Similar documents
Temperature Products. Temperature Products

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Fluid Power Fluid Power

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.

9012G Pressure and 9016G Vacuum Switches

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Mini temperature switch Stainless steel switch enclosure Model TXS

u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air

Data Sheet. A-Series Miniature Watertight Pressure Switches

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

PISTON STYLE GAUGE. Mid-West Instrument

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Compact temperature switch Model TCS

Mechanical Pressure Products

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Compact differential pressure switch Models DC, DCC

Bourdon Tube Pressure Switches

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

VACUUM A RESOURCE FOR EVERYONE

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Palmer Circular Chart Recorders

PPT 802, Proximity Probe Transducer System

37T Series Moisture Resistant Temperature Controls

short form catalog SFC 07

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

SP/SF Series Flow Switches

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Mini pressure switch Stainless steel switch enclosure Model PXS

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Pressure Switch with Gauge for Pressure

P70, P72, and P170 Controls for Low Pressure Applications

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Switch to. Generation NEW Electronic Level. One Series for. Pressure Temperature Level

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications

Mechanical Pressure Switches. Catalogue. Mechanical Pressure Switches. Control. Overview. every move

Quick Reference Charts

System 350 P352AB Electronic Pressure Control Series

J 6 Se r i e s. Pressure and Vacuum switches. features

Compact pressure switch Model PCS

Vibralert Mechanical Switch Model 5550

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Model 5000 Level Controller

2000 Series Geared Rotary Limit Switches

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Pressure. Pressure. Mechanical. Press. Switches

Adjustable Dead Band Pressure Switches

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

GO Switch Leverless Limit Switches 02 Reliable, Durable Position Sensing GO Switch leverless limit switches provide reliable, durable position sensing

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Temperature Switches. General Instructions

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Adjustable Dead Band Pressure Switches

Electropneumatic Timing Relays Series 7000 Industrial

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Pressure Controls Product Overview

MA-5200 Series MA-5300 Series

Dual Hi-Lo Pressure Switches

Features and benefits. Normally open, normally closed contact logic

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Environment-Sealed Basic Switches

TEMPERATURE REGULATORS W91/W94 Series

M-100 Adjustable flow switch with right-angle flow

Model 5000 Level Controller

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

MS Application. Features. Proportional Valve Actuator General Instructions

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction

Type Type 1001 Transducers. I/P & E/P Transducers

the Interactive Catalog

B Temperature Switches

Pressure Instrument Testing Equipment

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

M-50/55 Series. Fixed setting flow switch with in-line flow

Integrated Control modules

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

10 S e r i e s PRESSURE SWITCH. features

Installation and Service Instructions for EX Series Explosion-proof Switches

FF Pressure Switch. Diaphragm and piston switches

the Interactive Catalog

Control Without Compromise. Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments

Remote Temperature Controllers. Quick Selection Guide

Industrial Pressure Transmitters

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

Transcription:

Temperature Switches Temperature Switches c Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer c Valves & Regulators c Temperature c Level c Flow c Air Suspension Valves

Table of Contents Temperature Switches Supplemental Guide 3 Temperature Switch Accessories 7 Series TXR, TXL - Explosion Proof Temperature Switch 9 Series TPR - General Purpose Switch Series THR, THL - Temperature Switch 3 T9692X - Compact Explosion Proof Temperature Switch 5 Series TX, T2X, LX - Explosion Proof Temperature Switches 7 Series MTH, T2H - Remote Mount Temperature Switches 9 Series MLS - Bi-Metallic Switch 2 MLH, L2H - Local Mount Temperature Switches 23

Temperature Supplemental Guide Sensor Types Temperature Switch Products Local Mount Local mount type temperature switches are installed in the pipe or vessel. ln this type of sensor, the filling fluid surrounds the bellows. A negative temperature change forces the fluid to contract-expanding the bellows to actuate the switch. Positive temperature changes produce the opposite effect. Remote Bulb & Capillary Remote temperature switches allow the switch enclosure to be placed up to 25 feet from the media. These models use a bulb and capillary sensing device which may be ordered in standard six and 2 foot lengths. Extra lengths up to 25 feet are available. Six and 2 foot sensors can be copper or stainless steel with or without protective spiral-wound armor. The 25 foot lengths are armored stainless steel only. SINGLE OR DUAL CONTROL WATERTIGHT (NEMA 4 & 3) EXPLOSION PROOF (NEMA 7 & 9) ENCLOSURES GROUNDING SCREW PROVIDED TERMINAL STRIP LABELED 'C', 'NO' & 'NC' (SPOT SWITCH ELEMENTS) WIRES ARE COLOR CODED SNAP ACTION SWITCH OPTIONAL ADJUSTABLE DIFFERENTIAL THREADED CONDUIT CONNECTION TAMPERPROOF ADJUSTMENT COVER SELF-LOCKING ADJUSTMENT FIELD ADJUSTABLE WITH CALIBRATED DIAL (CALIBRATED C & F SAME DIAL) HIDDEN MOUNTING SCREW (NO PROTRUDING LUGS) CASE BULB MOUNT IN ANY POSITION MOTION AND VIBRATION RESISTANT OVERTRAVEL PROTECTION AMBIENT COMPENSATION DEVICE CANCELS OUT ADVERSE EFFECTS OF AMBIENT FLUCTUATION STAINLESS STEEL OR COPPER CAPILLARY IN 6' OR 2' STANDARD OR CUSTOM LENGTHS TO SUIT SUBMERISIBLE IN PRESSURIZED VESSEL (PRESSURE RANGE THROUGH 300 PSI) WIDE RANGE OF MEDIA & TEMPERATURE LIMITS (REMOTE BULB, LIQUID FILL) STANDARD OR CUSTOM LENGTH ARMORED CAPILLARIES AVAILABLE Barksdale offers both remote and local mount temperature switches in housed, NEMA 4 and/or explosion proof designs. All are available with one or two adjustable temperature set points and fixed or adjustable differential.

Supplemental Guide Temperature Switch Products General Data Barksdale was the first manufacturer to offer effective ambient compensation in electromechanical switches revolutionizing temperature switch accuracy through extreme temperature changes. In a liquid-filled bulb and capillary system, ambient temperature changes affect the expansion of the fluid resulting in false temperature sensing. An extreme ambient change from -65 F to + 65 F will decrease the accuracy of most switches by 20% or more. Or, if the temperature changes only 70, accuracy can be decreased by 5%. ±% Accuracy From Barksdale Bulb and capillary configurations overcome ambient temperature swings through stacking of precision, concave bimetal washers. An ambient temperature change causes the liquid fill in the bulb, capillary and bellows to expand or contract, an equal and opposite reaction occurs between the washers. This compensates for ambient temperature change assuring high repeatable accuracy even under wide ambient temperature swings. By reacting to ambient temperature changes as extreme as - 65 F to + 65 F, the accuracy of the mid-60% of the adjustable range is still within ±% of full-scale. Accuracy at constant ambient is ±0.5% full scale. Local mount temperature switches are not affected by ambient temperature changes in the same way as bulb and capillary types. All of the filling fluid is exposed to the media temperature the bulb is sensing. Therefore, there is no ambient temperature influence on the filling fluid. Ambient Temperature Compensation Comparison Curve Good Response Time Select for Mid-Range Setting For optimum repeat accuracy in areas of extreme temperature change, select the switch range that enables the desired set point to fall in the mid 60% of the adjustable range. 2

Temperature Supplemental Guide General Data Temperature Switch Products Differential (Actuation Value, Dead Band, Hysteresis) BY CLASS OF ELECTRICAL SWITCH USED IN BARKSDALE TEMPERATURE SWITCHES Differential tolerances on temperature switches are due to manufacturing tolerances on limit switches and sensing elements. The differential of each temperature switch will remain fixed within the tolerances shown. Test conditions and media used could affect differential. Hermetically Sealed Switches Barksdale Hermetically Sealed Temperature Switches were created for use in hostile environments where exposure to elements such as salt air, hydrogen sulfide and other corrosive agents and atmospheres might cause contact deterioration and switch failure. The switch elements meet the requirements for Class I, Division II hazardous areas. The Barksdale hermetically sealed switch element is the same size as most nonsealed micro-switches, making this modification of our standard switches simple and inexpensive.. Select the standard unit with the desired characteristics. 2. Refer to the catalog sections showing the actuation value (differential) and electrical rating of switch elements by class. (The Class of Electrical Switch for Hermetically Sealed switch elements is either AA, CC or HH.) Select the class (AA, CC or HH) desired. 3. Change the standard catalog number as follows: - Prefix the catalog number with H. - Substitute AA or HH for the standard switch element designation. - Drop any -UL suffixes. Examples: - Standard Catalog number T2H-H5 - Hermetically Sealed numbers are HT2H-AA5, HT2H-CC5 or HT2H-HH5 Sensing Element Adjustable Approximate Differential (Actuation Value, Deadband, Hysteresis) Range - F by class of switch element Bulb & Capillary Type Sensor B GH, H J K L M S Adjustable G** Can be AA HH CC to from reset after MTH -5-65 to + 50 3-5 -2-3 4-6 2-4 2-4 4 5 5.0-8.0.0-7.0.0-0.0 T2H -25 +50 to +250 3-5 -2-3 4-6 2-4 2-4 4 5 5.0-8.0.0-7.0.0-0.0 TX -35 +50 to +350 3-5 -2-3 4-6 2-4 2-4 4 5 5.0-8.0.0-7.0.0-0.0 T2X -60 +300 to + 600 5-7 2-4 3-5 5-8 4-6 4-6 7 25 5 2.0-2.0 2.0-.0 2.0-4.0 Local Mount MLH -20 thru 354-50 thru +350 4-7 -3-4 6-9 3-6 3-6 6 20 5 2.0-.0 2.0-0.0 2.0-3.0 L2H -45 thru 454 +50 thru +450 7-0 3-6 4-7 7-2 6-9 6-9 0 30 5 2.0-.0 2.0-0.0 2.0-3.0 LX -45 thru 454 +50 thru +450 7-0 3-6 4-7 7-2 6-9 6-9 0 30 5 2.0-7.0 3.0-6.0 3.0-9.0 *Differential values are the same for copper and stainless steel **-RD Models ***T2H, T2X, L2H Models Electrical Rating (Current given in Amperes) () For standard models the electrical ratings are listed on each page under lectrical Characteristics? (2) For other switch ratings, see table below and refer to corresponding Operating Characteristics. - Class GH switches are SPOT with gold contacts. - Class J & K switches are SPDT with fine silver contacts and an Elastomer Boot around pin actuators to prevent moisture and foreign matter from affecting contacts. - Class G switches are manual reset. - Class R & S switches are SPOT with fine silver contacts and adjustable differentials. - All other switch classes are SPOT with fine silver contacts and fixed differentials. - Class H & M switches meet humidity requirements of MIL-S-6743. - Class AA, CC & HH hermetically sealed. AC RATINGS INDUCTIVE LOAD - 50% POWER FACTOR CLASS OF MAXIMUM CONTINUOUS CURRENT SWITCH H,J B,K L M S G GH AA HH CC VOLTS 25 0 0 5 0 5 0.0 4.0 4.0 0.0 AC 250 0 0 5 0 5 0 4.0 4.0 0.0 480 3 0 5 3 5 0 600 2 2 DC RATINGS INDUCTIVE LOAD - L/R =.26 CLASS OF MAXIMUM CONTINUOUS CURRENT SWITCH H B,K L M S G GH VOLTS 6.5 5 8.0 8.0 5 5.0 DC 2.5 0 5.0 5.0 5 5.0 24.5 5.0.0 5 0.0 25.05.03.5.05.4 250.03.02.25.03.2 3

Supplemental Guide Temperature Switch Products General Data Temperature Conversion Table Find in the center column the number of the known temperature. If the known temperature is in Fahrenheit, the Centigrade equivalent is in the left hand column. If in Centigrade, the Fahrenheit equivalent is in the right hand column. The basic conversion formulas are: C = F - 32 X 5/9, OR C = F - 32 F = C X 9/5 + 32, OR F = C X.8 + 32.8 C F/ C F C F/ C F C F/ C F C F/ C F -73.3-00 -48.0-3.9 25 77.0 93.3 200 392.0 232.2 450 842.0-70.6-95 -39.0 -. 30 86.0 98.9 20 40.0 237.8 460 860.0-67.8-90 -30.0.7 35 95.0 04.4 220 428.0 243.3 470 878.0-65.0-85 -2.0 4.4 40 04.0 0.0 230 446.0 248.9 480 896.0-62.2-80 -2.0 7.2 45 3.0 5.6 240 464.0 254.4 490 94.0-59.4-75 -03.0 0.0 50 22.0 2. 250 482.0 260.0 500 932.0-56.7-70 -94.0 2.8 55 3.0 26.7 260 500.0 265.6 50 950.0-53.9-65 -85.0 5.6 60 40.0 32.2 270 58.0 27. 520 968.0-5. -60-76.0 8.3 65 49.0 37.8 280 536.0 276.7 530 986.0-48.3-55 -67.0 2. 70 58.0 43.3 290 554.0 282.2 540 004.0-45.6-50 -58.0 23.9 75 67.0 48.9 300 572.0 287.8 550 022.0-42.8-45 -49.0 26.7 80 76.0 54.4 30 590.0 293.3 560 040.0-40.0-40 -40.0 29.4 85 85.0 60.0 320 608.0 298.9 570 058.0-37.2-35 -3.0 32.2 90 94.0 65.6 330 626.0 304.4 580 076.0-34.4-30 -22.0 35.0 95 203.0 7. 340 644.0 30.0 590 094.0-3.7-25 -3.0 37.8 00 22.0 76.7 350 662.0 35.6 600 2.0-28.9-20 -4.0 43.3 0 230.0 82.2 360 680.0 32. 60 30.0-26. -5 5.0 48.9 20 248.0 87.7 370 698.0 326.7 620 48.0-23.3-0 4.0 54.4 30 266.0 93.3 380 76.0 332.2 630 66.0 20.6-5 23.0 60.0 40 284.0 98.9 390 734.0 337.8 640 84.0-7.8 0 32.0 65.6 50 302.0 204.4 400 752.0 343.3 650 202.0-5.0 5 4.0 7. 60 320.0 20.0 40 770.0 348.9 660 220.0-2.2 0 50.0 76.7 70 338.0 25.6 420 788.0 354.4 670 238.0-9.4 5 59.0 82.2 80 356.0 22. 430 806.0 360.0 680 256.0-6.7 20 68.0 87.8 90 374.0 226.7 440 824.0 365.6 690 274.0 Temperature Switch Operation and Safety WARNING Product must be installed in accordance with applicable NEC, ASME and local regulations as applicable including those that apply to installations in hazardous locations requiring explosion proof enclosures or similar construction. The temperature limitations shown on the individual catalog pages for the specific switch must not be exceeded. These temperatures must take into consideration the possible maximum system temperatures encountered. The maximum allowable pressure on the sensor is 300 psi. Over 300 psi, use suitable thermowell. The fluid used must be compatible with the materials of construction. Special cleaning and packaging may be required for special media such as oxygen. Consult factory. Temperature switches are not of sanitary construction and the fill fluid is toxic. Therefore, sensors should not be in contact with materials intended for ingestion unless suitable thermowell is used. Sensors listed in this catalog are filled with silicon oil. When silicon oil is combined with strong oxidizing agents, including (but not limited to) chlorine, nitric acid, and hydrogen peroxide, a spontaneous chemical reaction, ignition or explosion can result. When temperature switches containing fluid are used in such service, thermowells must be used. The electrical load through the temperature switch must not exceed the values shown in the catalog for the specific switch involved. Shock and vibration may affect the switch performance. Therefore, shock and vibration should be minimized. Consult factory for assistance. Troubleshooting and Maintenance Troubleshooting of the switch must be in strict compliance with the procedure set forth on the Troubleshooting and Maintenance section of this catalog. Field repair of UL, CSA or other listed units will void the UL or CSA listing of the repaired unit. Barksdale, Inc. components must not be used in life support applications of any kind. Failure to observe these warnings could result in serious injury or damage. 32 Fruitland Avenue Los Angeles, CA 90058 800-835-060 Fax: 323-589-3463 www.barksdale.com 4 See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0027-B 09/07 2007 Printed in the U.S.A.

Temperature Temperature Switch Accessories Thermowells, Split Nut, Union Connector, Capillaries Standard Local Mount Standard Local Mount /2 NPT threads Sensor submersible in pressurized vessel; pressure range through 300 psi. Example: MLH-H20S Sensor 3/4 NPT threads Thermowell Option: -W: Brass -WS: 36 Stainless Steel #0 Set screws (2); secures switch in thermowell; can be rotated 360 in well. Sensor submersible in pressurized vessel; pressure range: 000 to 7000 psi, depending on material and temperature. NOTE: Barksdale standard models cannot be field converted to add a Barksdale thermowell. To order a standard temperature switch with thermowell, add -WS to the model number. Example: MLH-H20S-WS Example: MLH-H20S-WS To order replacement temperature switch for thermowell models, less thermowell, add -Z8 to model number. Example: MLH-H20S-WS-Z8 Thermowells for High Pressure and Harsh Environments Thermowells for Remote Bulb and Capillary Models Only All electromechanical temperature switches may be used with a thermowell when pressures exceed 300 psi, if high velocities are present and with corrosive or abrasive medias. Thermowells also allow removal of the temperature switch or sensor without loss of contained media. When using a thermowell with a local mount temperature switch, two set screws are provided to secure the switch in the well allowing 360 rotation for easier electrical connection and readability. The use of a thermowell may increase response time to temperature change. By using heat transfer material, the increase can be kept to a minimum. Part Number Material P Process Connection NPT R V 20829-B Brass /2.688.625 20830-B Brass 3/4.875.750 20829-C 36SS /2.688.625 20830-C 36SS 3/4.875.750

Temperature Switch Accessories Thermowells, Split Nut, Union Connector, Capillaries Split Nut Used to hold sensor bulb in standard thermowell. Union Connector Used to hold sensor bulb in extra length thermowell. Seals the process connection where no thermowell is used. Note: Union contains compression discs and will seal to 300 psi. /2" NPT Part P Number Material NPT A 4086-B Brass /2 2-/4 4087-B Brass 3/4 2-/2 4086-C 36SS /2 2-/4 4087-C 36SS 3/4 2-/2 P (NPT) A.88 Part Number 20828 Thermowell Pressure-Temperature and Velocity Limitations Maximum Fluid Velocity Feet Per Second Material Insertion Length-"U" 2-/2" 4-/2" 7-/2" 0-/2" 3-/2 6-/2" 9-/2" 22-/2" Brass 32 29 46.8 23.6 4.5 9.6 6.9 5. (50) (83.5) Carbon Steel 40 249 90.3 45.6 27.8 8.5 3.2 9.8 (270) (50) A.I.S.. 304 & 36 483 272 97.3 49.7 30.4 20.3 4.5 0.7 (350) (208) Monel 396 24 77.5 39.2 23.8 6.0 0.3 7.7 (300) (67) The values in parentheses (00) represent safe values for water flow. Unbracketed values are for steam, air, gas and similar low density fluids. Pressure-Temperature Rating Lbs. Per Square Inch Material Temperature F 70 200 400 600 800 Brass 5000 4200 000 * * Carbon Steel 5200 5000 4800 4600 3500 A.I.S.I. 304 7000 7000 5600 5400 5200 A.I.S.I. 36 7000 7000 6400 6200 600 Monel 6500 6000 5400 5300 5200 *Stainless Steel Recommended. Capillary Variations Examples Examples without Manual with Manual Description Suffix Reset Reset (-RD) Copper Units with A (added to any 302 SS Armor standard catalog) TX-H50-A MTH-G50-A-RD Stainless Steel Units With 302 SS Armor T2H-H60S-2-A T2H-H60S-2-A-RD Extra Length Capillaries Available as Special. (over 2 in length) ConsultFactory for part number, price and delivery. 32 Fruitland Avenue Los Angeles, CA 90058 800-835-060 Fax: 323-589-3463 www.barksdale.com See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0028-C 09/07 2007 Printed in the U.S.A. 2

Explosion Proof Temperature Switch Series TXR, TXL Features Explosion-proof High accuracy Line or ambient sensing UL, CSA & ATEX approved Applications Heat tracing Hydraulic power units Combustion engines Compressors Machine tools and industrial equipment Process equipment General Specifications* Accuracy: Switch: Type: Rating: Electrical Characteristics: ±% of full scale Single pole double throw (SPDT), prewired snap action 22 amp @ 25/250/480 VAC All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Electrical Connection: 3/4 NPT female conduit connection. 3 pole terminal block accepts 6-0 AWG wire. Enclosure Ratings: NEMA 4, 7, 9, & IP65 Enclosure/Housing: Anodized aluminum, explosion proof, painted silver Bulb and Capillary: Material: 36L stainless steel Approvals: FM, UL file E58658, CSA - file LR 34556 Division and 2, Class I, Group B, C & D Class II, Group E, F & G, Class III. ATEX EEx d IIC, T6 (EX NEPSI GOST-R) Temperature Range: -40 to 60 F (-40 to 7 C) Ambient Temperature: -40 to 40 F (-40 to 60 C) Adjustment: External adjustment knob. Turn knob clockwise to decrease setpoint ENI/RFI: to EN 550 Vibration: 0 g s 0-500 Hz, MIL-STD 202F Shock: 50 g s, 0 ms, MIL-STD 90C Standard Options: -R (suffix): Double pole single throw (DPST) relay 22 amp @ 20/240/277 VAC. Contacts close on falling temperature. Relay Coil: 20 VAC, 4VA. Example: TXR-L2S-0R-Q0 Weight: 3.8 lb (.7 kg) Bulb: Capillary Length: 8 (203mm), 5/6 (8mm) dia. 0 (3m), remote mount only System Pressure (max): 300 psi without thermowell Fill: Silicone oil-filled * See Product Configurator for additional options. Media Temperature Limits -40 to 420 F (-40 to 25 C) -40 to 60 F (-40 to 7 C) Adjustable Range 25 to 325 F (-4 to 63 C) 5 to 40 F (-9 to 60 C) Differential (approximate) 0 F (5.6 C) 0 F (5.6 C) Sensing Location Line Sensing T-stat Ambient Sensing T-stat Catalog Number TXR-L2S-0-Q0 TXL-LS-Q0

Explosion Proof Temperature Switch Series TXR, TXL Technical Drawing 9/32-7/32 (30) Dimensions in inches (mm) Product Configurator Example TX R -L 2 S -0 -Q0 Base Configurator T X L R 2 Temperature switch NEMA 4, 7, 9 & IP65 explosion proof enclosure Limit Switch Local mount for ambient sensing Remote bulb & capillary -L 22 amp @ 25/250/480 VAC S -Q0 Heat tracing model (standard) Stainless steel sensor For TXL models -0 0 ft bulb & capillary for TXR models -0R2 Wetted Material Temperature Range Bulb & Capillary Length & Switch 22A DPST relay 3 with 0 ft bulb & capillary. (For TXR models) NOTES: Use temperature range for local sensing applications 2 Use temperature range 2 for remote sensing applications 3 DPST switch, 22 amps @ 20/240/277 VAC. Relay Coil: 240 Vac, 4 VA. Contacts close on falling temperature. Adjustable Range Media Temperature Limit Differential (Proof) (Approx.) Liquid Range F C F C F C Low High Low High Low High Low High +5 +40-9 +60-40 +60-40 +7 0 5.6 2 +25 +325-4 +63-40 +420-40 +25 0 5.6 32 Fruitland Avenue Los Angeles, CA 90058 800-835-060 Fax: 323-589-3463 www.barksdale.com See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0026-G 09/07 2007 Printed in the U.S.A. 2

Temperature General Purpose Switch Series TPR Features High accuracy NEMA 4X & IP 65 UL, CSA and CE approved Low cost Applications Heat trace Water equipment Process equipment Machine tools and industrial equipment Freeze protection General Specifications* Accuracy: Switch: Type: Rating: Electrical Characteristics: Wetted Parts: Electrical Connection: Enclosure Rating: Enclosure/Housing: ±4 F * See Product Configurator for additional options. Single pole double throw (SPDT), prewired snap action 22 amp @ 25/250/480 VAC All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Tin plated copper sensor & capillary -/8 (28mm) hole for 3/4 NPT conduit hub 2, 4 AWG stranded copper wire NEMA 4X Polycarbonate (black) Bulb and Capillary: Bulb: Capillary Length: System Pressure (max): Fill: Approvals: Temperature Range: Ambient Temperature: Vibration: Shock: Weight: 3-/8 (79mm), /6 (0mm) dia. 30 (762mm) or 20 (3048mm) 300 psi without thermowell Silicone oil-filled UL listed, file E56247 CSA certified, file LR 58658 EN/RFi: to EN 50-40 to 60 F (-40 to 7 C) Fixed setpoint factory set at 40 F Contact closes on decreasing temperature -30 to 40 F (-34 to 60 C) 0 g s 0-500 Hz, MIL-STD 202F 50 g s, 0 ms, MIL-STD 90C. lbs. (0.5 kg) Wiring Code Lead Normally Closed Common Normally Open Circuit Blue Purple Red Media Factory Differential Catalog Temperature Preset (approximate) Number Limits -40 to 60 F 40 F 0 F (-40 to 7 C) (4.4 C) (5.6 C) TPR-LN-3X-Q0

General Purpose Switch Series TPR Technical Drawing Dimensions in inches (mm) Product Configurator Example T P R -L N -3X -Q0 Basic Configurator T Temperature switch -Q0 Heat tracing model Basic Configurator P Polycarbonate plastic NEMA 4X enclosure Basic Configurator R Remote bulb & capillary Bulb & Capillary Length -3X 3 foot bulb & capillary sensor -0X 0 foot bulb & capillary sensor Limit Switch -L 22 amp @ 25/250/480 VAC; standard Temperature Range Range Fixed Set-point (Decreasing) F C F Low High Media Temperature Limit (Proof) C Low High Differential (Approx.) Liquid F C 40 4.4-40 +60-40 +7 0 5.6 Wetted Material N Tin plated copper sensor 32 Fruitland Avenue Los Angeles, CA 90058 800-835-060 Fax: 323-589-3463 www.barksdale.com See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0025-D 09/07 2007 Printed in the U.S.A. 2

Temperature Temperature Switch Series THR, THL Features High accuracy Line or ambient sensing NEMA 4X & IP 65 UL, CSA and CE approved Applications Heat tracing Process equipment Machine tools and industrial equipment General Specifications* Accuracy: Switch: Type: ±% of full scale SPDT, prewired snap action Rating: 22 amp @ 25/250/480 VAC Electrical All models incorporate Underwriters Characteristics: Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Electrical Connection: 3/4 NPT female conduit connection. 3 pole terminal block accepts 4-0 AWG wire. Electrical Ratings: 22 amps @ 25/250/480 VAC Enclosure Rating: NEMA 4X Enclosure/Housing: Anodized die cast aluminum Green polyurethane coated Other exposed parts: stainless steel Bulb and Capillary: Material: 36L stainless steel Approvals: UL listed, file 56247 CSA certified, file LR 34555 EMI/RFI: to EN 550 Temperature Range: 5 F - 325 F (-9 C - 63 C) Ambient See table below (media temperature limit) Temperature: Adjustment: External adjustment knob. Turn clockwise to decrease setpoint Vibration: 0 g s 0-500 Hz, MIL-STD 202F Shock: Standard Options: R**(Option): R2 (Option): Weight: 50 g s, 0 ms, MIL-STD 90C DPST relay switch 22 amp @20/240/277 VAC Relay coil: 20 VAC, 4VA 20/240/277 VAC Relay coil: 240 VAC, 4VA.9 lbs. (0.9 kg) Bulb: 7-3/4 (97mm), 5/6 (8mm) dia. Capillary Length: System Pressure (max): Fill: 0 (3m), remote mount 300 psi without thermowell Silicone oil-filled * See Product Configurator for additional options. ** Must specify; close on rising or falling temperature Media Adjustabl Differential Sensing Catalog Temperature Range (approximate) Location Number Limits -40 to 420 F 25 to 325 F 0 F Line Sensing THR-L2S-0X-Q0 (-40 to 25 C) (-4 to 63 C) (5.6 C) T-stat -40 to 60 F 5 to 40 F 0 F Ambient THL-LS-X-Q0 (-40 to 7 C) (-9 to 60 C) (5.6 C) Sensing T-stat Factory Set Point 25 F ± 5 decreasing 40 F ± 4 decreasing

Temperature Switch Series THR, THL Technical Drawing Dimensions in inches (mm) Product Configurator Example TH R -L 2 S -0X -Q0 Base Configurator TH Aluminum NEMA 4X enclosure -Q0 Heat tracing model (standard) L R 2 Local mount for ambient sensing Remote bulb & capillary Bulb & Capillary Length; Switch -X For THL models (with NEMA 4X enclosure) -0X 0 ft bulb & capillary for THR models Limit Switch -L 22 amp @ 25/250/480 VAC -0R2X 22A DPST relay3, 0 ft bulb & capillary for THR models Temperature Range Range Adjustable Range Media Temperature Limit (Proof) F C F C Low High Low High Low High Low High Differential (Approx.) Liquid F C Wetted Material S Stainless steel sensor +5 +40-9 +60-40 +60-40 +7 0 5.6 2 +25 +325-4 +63-40 +420-40 +25 0 5.6 Use Temperature Range for local sensing applications 2 Use Temperature Range 2 for remote sensing applications 3 DPST switch, 22 amps @ 20/240/277 VAC. Relay Coil: 240 Vac, 4 VA. Contacts close on falling temperature. 32 Fruitland Avenue Los Angeles, CA 90058 800-835-060 Fax: 323-589-3463 www.barksdale.com See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0024-E 09/07 2007 Printed in the U.S.A. 2

Compact Explosion Proof Temperature Switch T9692X Features Compact design Convenient field adjustability NEMA 4X, 7 & 9 SPDT and DPDT switch ATEX approved Class I Div I Direct or remote mount Panel mount capability 36 stainless steel NACE compliant Armored capillary Applications Offshore platforms Safety panels Chemical plants & refineries Compressor skids Instrument panels Hazardous location applications General Specifications* Accuracy: Typical Life: Switch: Electrical Ratings: Materials: Bulb, Capillary & Armor: Enclosure: Local Mount Element: Electrical Connection: * See Product Configurator for additional options. 63% of full scale million cycles SPDT, snap action, Class EE, simulated DPDT (optional) amps @ 25/250 VAC 5 amps @ 30 VDC (EE class) 36 stainless steel 36 stainless steel Enclosure Ratings: NEMA 4X, 7 & 9 300 series stainless steel /2 inch NPT male conduit connection 8 AWG, 8 (300 mm) free leads Approvals: ATEX: UL: CSA: Ambient Operating Temperature: CSA & ATEX: CE 008 LCIE 08 ATEX 6074X II 2 G Ex d IIC T6, -40 C < Tamb < 60 C Listed 366S, Class: I, Groups: A, B, C, D, -25 C < Tamb < 60 C Class: I, Groups: B, C, D -40 C < Tamb < 60 C -40 F to 40 F (-40 C to 60 C) UL: -3 F to 40 F (-25 C to 60 C) EMI/RFI: EN550 Vibration: 0g s 0-500 Hx, MIL-STD 202 F Shock: 50g s, ms, MIL-S-90C Adjustment: Internal locking adjustment wheel, /6 hex set screw Weight: 3 lbs. maximum Wiring Code Wiring Diagram Lead Circuit # Circuit #2 (SPDT) (DPDT) Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow Ground Green NC (Blue) C (Purple) NO (Red) Ground (Green) INCR P NC (Blue) C (Purple) NO (Red) NC2 (Orange) INCR P C2 (Brown) NO2 (Yellow) Ground (Green)

Compact Explosion Proof Temperature Switch Technical Drawing Dimensions in inches [mm] T9692X.5 38 8" FREE LEADS SEE WIRE COLOR CODE CHART FOR FURTHER DETAILS /2 NPT CONDUIT CONNECTOR T U SC 4.6 8.32 8 5.9 50 8-32 GRD SCREW " HEX TOOL REQUIRED 3.7 [97] MAX.9 24 /2 NPT 2X.2 5 MOUNTING HOLES.2 5. 29 5.3 35 3.7 MAX 94 MAX.5 38 CAPILLARY AND BULB NOT SHOWN FOR CLARITY.2 5 (ARMOR DIA.) (.06[.6] NON-ARMOR).5 3 LOCAL MOUNT OPTION ARMOR VERSION SHOWN Product Configurator Example T9692X - EE - -072 Base Configurator T9692X Temperature switch Number of Circuits - SPDT switch -2 Simulated DPDT switch (2 SPDTs) Options Blank Standard -A Stainless steel armor -SXXX -WXXX Factory preset Extra wire length (XXX=inches) Limit Switch EE GH Silver contacts amps @ 25V/250 VAC; 5 amps @ 30 VDC Gold contacts amp @ 25/250 VAC Temperature Ranges Adjustable Range Approx. Deadband 2 Actuation Value Media Temperature Limits Proof Temperature - -0 F to 0 F (-23 C to 43 C) 5 F to 30 F (2.8 C to 6.7 C) -40 F to 60 F (-40 C to 7 C) 60 F (7 C) -2 95 F to 220 F (35 C to 04 C) 5 F to 30 F (2.8 C to 6.7 C) 40 F to 270 F (4 C to 32 C) 270 F (32 C) -3 80 F to 330 F (82 C to 65 C) 5 F to 30 F (2.8 C to 6.7 C) 70 F to 380 F (2 C to 93 C) 380 F (93 C) Capillary Length -072 6 ft (.8 meters) -08 9 ft (2.7 meters) -44 2 ft (3.7 meters) -00 Local mount Not available in local mount 2 Deadband values indicated when used with the EE limit switch 32 Fruitland Avenue Los Angeles, CA 90058 % 800-835-060 Fax: 323-589-3463 www.barksdale.com See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0029-A 0/08 2008 Printed in the U.S.A. 2

Explosion Proof Temperature Switches Features Explosion-proof for hazardous locations High accuracy Remote, local or ambient sensing UL, CSA & ATEX approved NEMA 4, 7, 9 & IP65 Applications Oil & gas Heat tracing Printing machinery Compressors Process equipment Machine tools and industrial equipment Series TX, T2X, LX LX T2X General Specifications* Accuracy: Switch: Single Setting: Dual Setting: Electrical Characteristics: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing: * See Product Configurator for additional options. Wiring Code ±% of mid-60% of full range. At constant ambient +/- 0.5% of full scale. One () single pole double throw (SPDT) circuit. Two (2) independent single pole double throw (SPDT) circuits. All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. 304 stainless steel Single: 3-pin terminal strip Dual: 6-pin terminal strip AC value at 75% power factor 0 amps 25, 250 volts AC, 3 amps 480 volts AC. Automatically reset by snap-action of switch. Designed for hazardous locations: Class I, Division & 2 NEMA 4, 7, 9 & IP65 tamper-proof external adjustment, enclosed terminal strip. Lead Circuit # Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow Local Mount: Bulb & Capillary: Approvals: UL (standard): CSA (standard): ATEX (optional): Temperature Range: Adjustment: Standard Options/ Modifications: Weight: Wiring Diagram NO (Red) C (Purple) NC (Blue) Immersion length 2-/6 inches 6 and 2 foot length standard. Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under Temperature indicating and regulating equipment, for use in hazardous locations, Class I, Groups B, C and D; Class II, Groups E, F and G. File No. E58658, Guide No. XBDV File No. LR34556, Guide 400-E-O.8. Class 4868. EX models are ATEX certified per ISSeP 03 ATEX 2 & maked as follows: CE 008 II2 GD EEx d IIC T6 T85 C See product configurator Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. For thermowels, split nuts and union connections, see accessory pages. Single - approximate 3.0 lbs. Dual - approximate 7.0 lbs. T NO (Red) C (Purple) NC (Blue) NO (Yellow) C (Brown) NC (Orange) T

Explosion Proof Temperature Switches Series TX, T2X, LX Technical Drawing LX TX Dimensions in inches (mm) Product Configurator Hermetically Sealed H Sensing Type T L Hermetically sealed limit switch option - Class I, Division II (requires AA, CC or HH limit switch) Remote bulb & capillary Local mount Example H T X -HH 25 S -2 -A Wetted Material Options -RD -EX -Sxxx Manual reset (must use when selecting G limit switch option) 3 Only available on T2X ATEX certification Factory pre-set (consult factory) Set Point Single setpoint (SPDT) 2 Dual setpoint (2 SPDT) Enclosure X Limit Switch 2 -H 0 amps @ 25/250 VAC; 3 amps @ 480 VAC (standard) -B -G 0 amps @ 25/250/480 VAC; 2 amps @ 600 VAC; 0.05 amps @ 25 VDC; 0.03 amps @ 250 VDC 0 amps @ 25/250/480 VAC; 2 amps @ 600 VAC; 0.4 amps @ 25 VDC; MANUAL RESET (only available for T2X) 3 -J 0 amps @ 25/250 VAC; 3 amps @ 480 VAC (with elastomer boot) -L -M -S -GH -AA -CC -HH NEMA 4, 7, 9 & IP65 explosion proof enclosure 5 amps @ 25/250/480 VAC; 0.03 amps @ 25 VDC; 0.02 amps @ 250 VDC 0 amps @ 25/250 VAC; 3 amp @ 480 VAC; 0.5 amps @ 25 VDC; 0.25 amps @ 250 VDC 5 amps @ 25/250/480 VAC; 0.05 amps @ 25 VDC; adjustable differential 4 amp @ 25VAC; gold contacts Hermetically sealed; 4 amps @ 25/250 VAC Hermetically sealed; 0 amps @ 25/250 VAC Hermetically sealed; 5 amps @ 25/250 VAC Blank S Capillary Length Blank Not available with local mount version. 2 Changing limit switch will effect deadband; See sales drawing 3 When selecting the manual reset option on dual setting switches (T2X), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. Only available with T2X. Brass sensor 304 stainless steel (6ft capillary for remote sensing models) Blank = 6 foot capillary -2 2 ft capillary -25 25 ft stainless steel capillary with armor (use with the A options) Temperature Range 32 Fruitland Avenue Los Angeles, CA 90058 800-835-060 Fax: 323-589-3463 www.barksdale.com Thermowell (Local Mount only) 36 stainless steel thermowell -WS (local mount only) Armor Option (Bulb & Capillary only) See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0022-G /08 2008 Printed in the U.S.A. 2 Blank Blank if not required -A 302 stainless steel armor Remote sensor ranges Adjustable Range Media Temperature Limit (Proof) Differential (Approx.) 2 Range Low High Low High Low High Low High F C 54-50 F +50 F -45 C +66 C -00 F +200 F -73 C +93 C to 2.5 to. 25 +50 F +250 F +0 C +2 C -00 F +300 F -73 C +49 C to 2.5 to. 35 +50 F +350 F +66 C +77 C -00 F +400 F -73 C +205 C to 2.5 to. 60 +300 F +440 F +49 C +227 C 0 F +650 F -8 C +343 C 2 to 4. to 2.2 603 +320 F +600 F +60 C +36 C 0 F +650 F -8 C +343 C 2 to 4. to 2.2 Local mount sensor ranges Adjustable Range Media Temperature Limit (Proof) Differential (Approx.) 2 Range Low High Low High Low High Low High F C 20-50 F +75 F -45 C +24 C -00 F +250 F -73 C +2 C to 3.5 to.6 202 +5 F +40 F +9 C +60 C -00 F +250 F -73 C +2 C to 3.5 to.6 203 +75 F +200 F +24 C +93 C -00 F +250 F -73 C +2 C to 3.5 to.6 35 +00 F +225 F +38 C +07 C -00 F +400 F -73 C +205 C 6 to 9 3.3 to 5.0 204-50 F +200 F -45 C +93 C -00 F +250 F -73 C +2 C to 3.5 to.6 354 +00 F +350 F +38 C +77 C -00 F +400 F -73 C +205 C 6 to 9 3.3 to 5.0 454 +50 F +450 F +66 C +232 C 0 F +500 F -8 C +260 C 3 to 6.6 to 3.3 4 When selecting the S adjustable differential limit switch option on a dual setting switch (T2X), a standard H switch will be paired with an S switch. Dual S pricing will apply.

Remote Mount Temperature Switches Series MTH, T2H Features Reliable & accurate Ambient compensated NEMA 4, 3 and IP 65 UL, CSA & CE approved Single or dual switching Applications Marine & shipbuilding Railroad Oil & gas Medical Compressors Water equipment Process equipment Machine tools and industrial equipment General Specifications* Accuracy: Switch: Electrical Characteristics: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing: * See Product Configurator for additional options. ±% of mid-60% of full range. At constant ambient ±0.5% of full scale. One () SPDT or two (2) independent SPDT circuits All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Copper or 304 stainless steel Single: 3-Pin terminal strip Dual: 6-Pin terminal strip AC value at 75% power factor 0 amps @ 25, 250 volts AC, 3 amps @ 480 volts AC. Automatically reset by snap-action of switch. Watertight and dust-tight indoor and outdoor (NEMA 4)/oil-tight and dust-tight indoor (NEMA 3). Bulb & Capillary: Approvals: UL: CSA: Temperature Range: Adjustment: Weight: 6 and 2 foot length standard. See operating characteristics and product configurator. Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under temperature indicating and regulating equipment. File No. E56247, Guide No. XAPX File No. LR34555, Guide 400-E-O Class 483 See product configurator Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. Single: approximate.5 lbs. Dual: approximate 3.0 lbs. Wiring Code Wiring Diagram Lead Circuit # Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow NO (Red) C (Purple) NC (Blue) T NO (Red) C (Purple) NC (Blue) NO (Yellow) C (Brown) NC (Orange) T MTH T2H

Remote Mount Temperature Switches Series MTH, T2H Technical Drawing T2H MTH COPPER 3 6 Dimensions in inches (mm) Product Configurator Example H M T H -HH 54 S -2 -A -FX Options H Blank M Blank Switch T T2 H Hermetically sealed limit switch option - Class I, Division II (requires AA, CC or HH limit switch) Standard Enclosure Single set point switch models Dual switch models Single SPDT Dual switch 2 independent SPDT NEMA 4 & IP65 enclosure NOTES: Use G limit switch for single set point models that need this option. When selecting the manual reset option on dual setting switches (T2H), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. 2 Changing limit switch will effect dead band; See sales drawing. 3 When selecting the S adjustable differential limit switch option on a dual setting switch (T2H), a standard H switch will be paired with an S switch. Dual S pricing will apply. 4 Add S wetted material adder to this. No additional adder from armor options table. Limit Switch 2 -H 0 amps @ 25/250 VAC; 3 amp @ 480 VAC (standard) -B 0 amps @ 25/250/480 VAC; 2 amps @ 600 VAC; 0.05 amps @ 25 VDC; 0.03 amps @ 250 VDC 0 amps @ 25/250/480 VAC; 2 amps @ 600 VAC; 0.4 -G amps @ 25 VDC; MANUAL RESET -J 0 amps @ 25/250 VAC; 3 amps @ 480 VAC (with elastomer boot) -L 5 amps @ 25/250/480 VAC; 0.05 amps @ 25 VDC; 0.03 amps @ 250 VDC -M 0 amps @ 25/250 VAC; 3 amp @ 480 VAC; 0.5 amps @ 25 VDC; 0.25 amps @ 250 VDC -S 5 amps @ 25/250/480 VAC; 0.05 amps @ 25 VDC; Adjustable differential 3 -GH amp @ 25VAC; gold contacts -AA Hermetically sealed; 4 amps @ 25/250 VAC -CC Hermetically sealed; 0 amps @ 25/250 VAC -HH Hermetically sealed; 5 amps @ 25/250 VAC Temperature Range Range Adjustable Range Media Temperature Limit (Proof) F Low High C Low High F Low High C Low High Differential 2 (Approx.) Liquid F C 54-50 +50-45 +66-00 +200-73 +93 to 2.5 to. 25 +50 +250 +0 +2-00 +300-73 +49 to 2.5 to. 35 +50 +350 +66 +77-00 +400-73 +205 to 2.5 to. 60 +300 +400 +49 +227 0 +650-8 +343 2 to 4. to 2.2 603 +320 +600 +60 +36 0 +650-8 +343 2 to 4. to 2.2 Calibrated Dial Adjustment Calibrated 5 Subdivision 200 Span 5 Subdivision 40 Span 0 Subdivision 280 Span 32 Fruitland Avenue Los Angeles, CA 90058 800-835-060 Fax: 323-589-3463 www.barksdale.com -RD Manual reset Wetted Material See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T002-G /08 2008 Printed in the U.S.A. 2 -FX -SXXX Blank -A Blank S NEMA 4X enclosure Factory pre-set (consult factory) Armor Options Blank if not required 302 stainless steel armor (standard) Capillary Length -2 2 foot capillary -25 25 foot stainless steel 4 [use -A (armor) and S (stainless steel wetted material) options] 6 foot copper capillary 6 foot 304 stainless steel capillary

Temperature Bi-Metallic Switch Series MLS Features Bi-metallic sensor Compact design NEMA 4 & IP65 One piece design Applications Air compressors Medical compressors Process equipment Water treatment Mining Machine tools and industrial equipment General Specifications* Accuracy: Switch: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing Process Connection: Conduit Connection: Proof Pressure: Cycle Life: See adjacent table SPST-NO or SPST-NC Brass 8, 8 AWG PTFE free leads 5A @ 25 Vac; 0A @ 250 Vac NEMA 4, IP65 /2 NPT /2 NPT 500 psi 00,000 cycles Approvals: CE qualified UL and CSA Temperature Range: 50 F - 300 F Proof Temperature: 340 F Warranty: Weight: year 0.5 lb. * See product configurator for additional options. Differential depends on service conditions and test methods

Bi-Metallic Switch Series MLS Technical Drawing Number Shown = Set Point /2 NPT 7/8 HEX /2 NPT TEMPERATURE SENSING PROBE /6 (7.8) 8 AWG. BLACK PTFE LEADS 8 LONG STANDARD -/2 (38.) 2-/8 (53.3) 3-/2 (REF.) (88.9) Dimensions in inches (mm) Product Configurator Example ML S -30 -I -C -W36 Prefix ML Miniature local thermowell Switch Single SPST switch point Housing S Stripped model Option -WXXX Extra wire length (XXX = inches) Setpoint* -50 50ºF setpoint -70 70ºF setpoint -75 75ºF setpoint -25 25ºF setpoint -30 30ºF setpoint -65 65ºF setpoint -200 200ºF setpoint -235 235ºF setpoint -275 275ºF setpoint -300 300ºF setpoint Set Point Direction -D Decreasing (falling) temperature -I Increasing (rising) temperature Contact Form -O Normally open -C Normally closed * NOTE: Consult factory for ranges not listed. Minumum order quantity - 20 pieces for non-standard ranges. Ranges specified in 5 increments. Example: -250 = 250 F 32 Fruitland Avenue Los Angeles, CA 90058 800-835-060 Fax: 323-589-3463 www.barksdale.com See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0023-C 09/07 2007 Printed in the U.S.A. 2

Local Mount Temperature Switches Features Reliable & accurate Local sensing NEMA 4 & IP 65 UL, CSA & CE approved Single or dual switching Applications Oil & gas Mining Tanks and reservoirs Compressors Plastic machinery Factory automation Process equipment Machine tools and industrial equipment MLH, L2H General Specifications* Accuracy: Switch: Electrical Characteristics: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing: Local Mount: * See Product Configurator for additional options. ±% of mid-60% of full range. At constant ambient ±0.5% of full scale. Single: SPDT Dual switching: 2 independent SPDT circuits All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Brass or 304 stainless steel Single: 3-pin terminal strip Dual: 6-pin terminal strip AC value at 75% power factor 0 amps 25, 250 volts AC, 3 amps 480 volts AC. Automatically reset by snap-action of switch. Water-tight and dust-tight indoor and outdoor (NEMA 4) / oil-tight and dust-tight indoor (NEMA 3). Immersion length 2-/6 inches Approvals/Listings: UL: CSA: Temperature Range: Adjustment: Weight: Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under temperature indicating and regulating equipment. File No. E56247, Guide No. XAPX File No. LR34555, Guide 400-E-O Class 483 See product configurator. Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. Single: approximate.5 lbs. Dual: approximate 3.0 lbs. Wiring Code Wiring Diagram Single Dual Lead Circuit # Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow NO (Red) C (Purple) NC (Blue) T NO (Red) C (Purple) NC (Blue) NO (Yellow) C (Brown) NC (Orange) MLH L2H T

Local Mount Temperature Switches Technical Drawing MLH, L2H L2H -5/8 (4.2) MLH 7 Dimensions in inches (mm) Product Configurator Example H M L H -HH 202 S -WS -FX H Blank M Blank Hermetically sealed limit switch option - Class I, Division II (requires AA, CC, GH or HH limit switch) Standard Single switch models Dual switch models Sensor Switch L Single set point (SPDT) L2 Dual set point (2 SPDT) Enclosure NEMA 4 & IP65 H enclosure Limit Switch 2 NOTES: Use G limit switch for single set point models that need this option. When selecting the manual reset option on dual setting switches (L2H), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. 2 Changing limit switch will effect dead band; See sales drawing. 3 When selecting the S adjustable differential limit switch option on a dual setting switch (L2H), a standard H switch will be paired with an S switch. Dual S pricing will apply. 4 Not available with hermetically sealed limit switches -H 0 amps @ 25/250 VAC; 3 amp @ 480 VAC (standard) -B 0 amps @ 25/250/480 VAC; 2 amps @ 600 VAC; 0.05 amps @ 25 VDC; 0.03 amps @ 250 VDC -G 0 amps @ 25/250/480 VAC; 2 amps @ 600 VAC; 0.4 amps @ 25 VDC; MANUAL RESET -J 0 amps @ 25/250 VAC; 3 amps @ 480 VAC (with elastomer boot) -L 5 amps @ 25/250/480 VAC; 0.03 amps @ 25 VDC; 0.02 amps @ 250 VDC -M 0 amps @ 25/250 VAC; 3 amp @ 480 VAC; 0.5 amps @ 25 VDC; 0.25 amps @ 250 VDC -S 5 amps @ 25/250/480 VAC; 0.05 amps @ 25 VDC; Adjustable differential 3 -GH amp @ 25VAC; Gold Contacts -AA Hermetically sealed; 4 amps @ 25/250 VAC -CC Hermetically sealed; 0 amps @ 25/250 VAC -HH Hermetically sealed; 5 amps @ 25/250 VAC -GH Hermetically selaed; amp @ 25 VAC; gold contacts Range 32 Fruitland Avenue Los Angeles, CA 90058 800-835-060 Fax: 323-589-3463 www.barksdale.com Options See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0020-G /08 2008 Printed in the U.S.A. 2 -RD -FX -SXXX Thermowell -W -WS Manual reset (use with G limit switch), 4 NEMA 4X enclosure Factory preset Brass local mount thermowell 36 stainless steel local mount thermowell Wetted Material Blank Blank if brass 304 stainless steel S sensor Adjustable Range Media Temperature Limit (Proof) Differential (Approx.) 2 Low High Low High Low High Low High F C 20-50 F +75 F -45 C +24 C -00 F +250 F -73 C +2 C to 3.5 to.6 202 +5 F +40 F -9 C +60 C -00 F +250 F -73 C +2 C to 3.5 to.6 203 +75 F +200 F +24 C +93 C -00 F +250 F -73 C +2 C to 3.5 to.6 35 +00 F +225 F +38 C +07 C -00 F +400 F -73 C +205 C to 3.5 to.6 204-50 F +200 F -45 C +93 C -00 F +250 F -73 C +2 C to 3.5 to.6 354 +00 F +350 F +38 C +77 C -00 F +400 F -73 C +205 C to 3.5 to.6 454 +50 F +450 F +66 C +232 C 0 F +500 F -8 C +260 C 3 to 6.6 to 3.3

Global Presence Global Presence Barksdale Inc. 32 Fruitland Ave. Los Angeles, CA 90058-0843 U.S.A. Phone: (800) 835-060 Fax: (323) 589-3463 Email: sales@barksdale.com www.barksdale.com Barksdale GmbH Dorn-Assenheimer Strasse 27 6203 Reichelsheim, Germany Phone: (49) 6035-949-0 (main office) (49) 6035-949-204 (sales) Fax: (49) 6035-949-/-3 Email: info@barksdale.de www.barksdale.de Barksdale GmbH Dorn-Assenheimer Strasse 27 6203 Reichelsheim, Germany Phone: (49) 6035-949-0 (main office) (49) 6035-949-204 (sales) Fax: (49) 6035-949-/-3 Email: info@barksdale.de www.barksdale.de Barksdale India SF- 43, Ansal Fortune Arcade Sector 8 India-2030 Noida Phone: +9-20 25 0 522 Fax: +9-20 25 0 520 manojsingh@barksdale.in