Specifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation

Similar documents
255 Valve Specifications

Magnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work

TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL

Performa Valve Specifications. 263 and 268 Configurations. imagination at work

COMMERCIAL CONTROL VALVES. Magnum Control Valve

Performa Valve Specifications. 263 and 268 Configurations. imagination at work

wd-2

255 Valve Specifications

Control Valves, Fittings and Accessories

Control Valves, Fittings and Accessories

AquaMatic Products. Valves, Stagers and Controllers OVERVIEW. GE Water & Process Technologies

Superior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770

Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI

Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS

Water Specialist 1 Control Valve Series Model: WS1TC 1.25 Control Valve Series Model: WS1.25TC

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

WS1 & 1.25 Man u al. Introduction. The following general warnings and the specifications in Table 1 must appear in the OEM s System Manual.

Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.

PRESSURE GAGES AND TEST TAPS

Operation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.

5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.

740/760 Control 255 and Performa Series Valves (268, 268FA)

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

AUTOTROL 742/762 CONTROL 255 & PERFORMA SERIES VALVES (263, 268, 268 FA)

Operation Manual. 742/762 Control 255 and Performa Series Valves (263, 268, 268FA) For Sales & Service questions please contact your dealer:

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

COMMERCIAL UST ADD WATER BULLETIN; ISSUE 1

Operation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:

Water Specialist WS2H and WS3 Control Valve Manual

Logix Magnum IT and Cv Valves. Installation and Service Manual

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

Assembled Engineered Systems. Softeners Filters Specialty Systems

OWNER S MANUAL FOR ALL GREENSAND SYSTEMS

Commercial Softeners

Water Specialist 1 Control Valve Series Model: WS1EI 1.25 Control Valve Series Model: WS1.25EI

Water Specialist 1.5" CC Control Valve Programming and Drawings Manual

Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS

Water Specialist CI Control Valve Programming and Cover Drawing Manual

Model WS1 Demand. Operation & Maintenance Manual. 114 Vista Parkway Avon, IN New Aqua L.L.C.

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

Fleck Fiberglass Section 9 Chloride Dealkalizers

Model 7000XTR. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

BNT 85 /185 Valve Operation Manual

Watco Pro Series Water Conditioner

TNT SERIES WATER CONDITIONERS

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

Consumer s Filter Manual. ProMate 6.0 Iron Curtain Junior Filter Manual

ProFloSE. Downflow Brining Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

Water Specialist WS2H and WS3 Control Valve Drawings and Service Manual

BLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09

Fleck Epoxy Lined Section 2 Steel Softeners

Installation and Operation Manual

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

Superior Water And Air

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Model 5600SXT Downflow

FLECK 2850S SERVICE MANUAL. waterpurification.pentair.com

Iron Blaster System Owner s Manual

IWT 565 Series Valve Operation Manual

Installation and Operations Manual

Fleck Top Mount Section 1 Fiberglass Softeners

Water Specialist EE Control Valve Programming and Cover Drawing Manual

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

AQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS

Owners Manual Installation Instructions. For Models PTCF PTCF PTCF

Model 5600SXT Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Owner s Filter Manual. ProMate 6.0 Iron Curtain Junior Filter Manual

AquaMatic Series. A100 and A200 Stager Controls

Water Specialist 1.5, 2 and 2 QC Control Valve Drawings and Service Manual

Owner s Manual HELLENBRAND, INC.

P/N: (Rev. G 1/19/10)

ADVANCE. Backwashing Filters and Tannin Filter. Installation Instructions & Owner s Manual

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

COMMERCIAL / INDUSTRIAL WATER SOFTENERS

Iron Gate Air Pump System Manual

TotalCare Series. Water Conditioners

Water Specialist EI Control Valve Programming and Cover Drawing Manual

Water Specialist WS1TT Drawings and Service Manual

Installation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners

Water Specialist WS1TT Drawings and Service Manual

TABLE OF CONTENTS. System Information...3. Pre-Installation Instructions...3. Installation Instructions Control Information...

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

Chemical Free Iron Sulphur Filtration System Owner's Operation and Maintenance Manual

Fleck 5600SXT Upflow. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET

NUGEN Pure Water Systems Fusion XT. Installation Instructions and Owners Manual

REIONATOR OWNER'S MANUAL. ACTIVATE YOUR WARRANTY BY REGISTERING YOUR PRODUCT AT or call

Rayne Guardian Water Conditioner This manual contains information on setting the controller and normal operating maintenance required by the owner

Upper Distributor Prevents Loss of Resin to Service or Drain Flow Rates Up To 15 GPM. Clock is Simple to Set.

3200ET TIMER. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide

65 Series. Valve Operation Manual

WATTS/Taras. Water Treatment Valves and Accessories. Commercial. Residential

WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

TTV Series. Softening Water System. Installation, Operation and Maintenance Manual. Revised 01/17/13

MGTE Series 1 1/2 Metered & Time Clock

VALVE. Water Treatment Controls ~~~~ SERVICEMANUAL ----

Transcription:

Specifications GE Osmonics Autotrol 255 Series Valve Specifications Series Controllers Flow Rates (Valve Only) Service @ 15 psi (1.03 bar) drop 15.5 gpm (3.52 m 3 /h) Backwash @ 25 psi (1.72 bar) drop 6.0 gpm (1.36 m 3 /h) Service Cv = 3.99 (Kv = 3.4) Backwash Cv = 1.20 (Kv = 1.0) Note: Tested with a 3/4-inch brass manifold Regeneration Operation Controller Configuration 700 Series Electronic Controller Regeneration Sequence 7-cycle high-efficiency regeneration sequence Cycle Times Electronically Configured by Computer Backwash, draw, slow rinse, fast rinse, backwash #2, fast rinse #2, refill Valve Connections/Dimensions Tank Thread 2-1/2-inches 8, male Inlet/Outlet Manifold (Brass or Noryl ) 1-inch NPT or 1-inch BSPT, female 3/4-inch NPT or 3/4-inch BSPT, female 3/4-inch NPT or BSPT, male, Noryl 1/2-inch NPT or BSPT, male, Noryl Drain Line 1/2-inch (manifold dependent) Brine Line 1/4-inch or 3/8-inch NPT, male; air check built into valve Distributor Tube Diameter 1.050 inches (27 mm) or 13/16-inch (20.6 mm) Distributor Tube Length 1-1/8 ± 1/8 inches (29 mm ± 3 mm) above top of tank Design Specifications/Ratings Valve Body Glass-filled Noryl NSF listed material Rubber Components Compounded for cold water NSF listed materials Valve Materials Certification NSF/ANSI 44 rated component for material safety Weight (Valve with Control) 4 Ibs (1.8 kg) Recommended Operating Pressure 20-120 psi (1.38-8.27 bar) Canada 20-100 psi (1.38-6.89 bar) Hydrostatic Test Pressure 300 psi (20.69 bar) Water Temperature 35-100 F (2-38 C) Ambient Temperature* 35-120 F (2-48.9 C) *Recommended use of outdoor cover for direct sunlight applications Autotrol 255 Valve

Options Turbine for Demand Units Standard manifold, 1-inch Autotrol turbine Bypass Valve Noryl, 1-inch flow path, 1/2-inch (13mm) NPT male, drain Bypass Inlet-Outlet Fitting Kits: Copper, Sweat Tube Adapter 1-inch or 3/4-inch (25 mm or 19 mm) CPVC, Solvent Weld Tube Adapter 1-inch or 3/4-inch (25 mm or 19 mm) Plastic NPT or BSPT Pipe Adapter 1-inch male or 3/4-inch male (25 mm or 19 mm) Brass NPT or BSPT Pipe Adapter 1-inch male or 3/4-inch male (25 mm or 19 mm) Brine Refill Controls.33 gpm (1.25 Lpm) fixed Compatible with.17 gpm (.64 Lpm) fixed optional for small tank applications Regenerants/Chemicals Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, sodium hydroxide, hydrochloric acid, chlorine and chloramines Pressure Loss Characteristics bar psi 1.10 16 P R E S 1.00 0.90 0.80 14 12 S U R E D R O P 0.70 0.50 10 8 6 4 2 255 SERVICE FLOW 0 gpm 0 LWR 4630 2 4 6 8 10 12 14 16 m 3 /h 0 0.5 0.9 1.4 1.8 2.3 2.7 3.2 3.6 SERVICE FLOW See owners manual for specific concentrations Valve for use on potable water supply

Logix 700 Series Controller ELECTRICAL SPECIFICATIONS Controller Operating Voltage Input Supply Frequency Motor Input Voltage Electronics Operating Voltage Control System Power Consumption 12 Volt AC (Requires use of GE Osmonics provided transformer) 50 or 60 Hz (Controller configuration dependent) 12 Volt AC 3.5 Volt AC 3 Watts average TRANSFORMER SPECIFICATIONS All Logix Series Controllers require the use of a GE Osmonics supplied transformer. Transformer Output Voltage Transformer Input Options 12 Volt AC 400mA 115 Volt AC 50/60 Hz 230 Volt AC 50/60 Hz 100 Volt AC 50/60 Hz Transformer Plug Options Indoor North American Plug Outdoor North American (UL Listed for outdoor use) Japanese Plug Taiwan/Korea Plug Australian Plug United Kingdom Plug Mainland Europe Plug Additional transformers may be available call for more information Available Logix 700 Series Controller Models 740 Residential electronic time-clock controller for single-tank filter or softener applications up to 14-inch diameter tanks 760 Residential electronic metered-demand (volumetric) controller for single-tank filter or softener applications up to 14-inch diameter tanks 742 C&I electronic time-clock controller for single filter or softener applications up to 120-inch diameter tanks, with fully programmable cycle times 762 C&I electronic metered-demand (volumetric) controller for single or twin-tank filter or softener applications up to 120-inch diameter tanks, with fully programmable cycle times

Logix Controller Feature Availability FEATURE 740 760 742 762 Regeneration Type Time Clock Demand (volumetric) Time Clock Demand (volumetric) Filter Capability 3 or 5-cycle 3 or 5-cycle 3 or 5-cycle 3 or 5-cycle Multiple Tank Capability Single tank Single tank Single tank Single or twin tank Calendar Override Day of week or up to 99-day override Day of week or up to 99-day override 99-day timer 99-day timer Manual Regeneration Immediate, delayed Immediate, delayed Immediate, delayed Immediate, delayed and double immediate and double immediate and double immediate and double immediate Adjustable Yes Yes Yes Yes Regeneration Time Cycle Times Computer calculated Computer calculated Fully programmable Fully programmable Remote-mount Faceplate Up to 50ft. (15.24m) away Up to 50ft. (15.24m) away Up to 50ft. (15.24m) away Up to 50ft. (15.24m) away Adjustable Salt Amount 3 options: 3 options: Fully adjustable Fully adjustable high-capacity, high-capacity, standard capacity, standard capacity, high-efficiency high-efficiency 3-cycle Filter Programmable None Fully programmable Fully programmable Control Capability backwash time 7-cycle High-efficiency Standard Standard Standard Standard Regeneration Sequence Adjustable Standard Standard Standard Standard Consumer Lock-out Dry Contact Signal Input Standard None Standard Standard (fixed) (programmable) (programmable) Super Capacitor 8 hour 8-hour 24-hour 24-hour Time/Date Back-up Reserve Type Not available 28-day variable Not available Variable or fixed reserve options Maintenance Interval Not available Not available Standard Standard Signal Feature Capacity Remaining Display Not available Standard Not Available Standard 99-year EEPROM Standard Standard Standard Standard Memory Retention Water Usage Display Not available Standard Not available Standard Displays Current Flow Rate Not available Not available Not available Standard

Injector* Performance 0.07 0.03 0.02 0.01 0.35 0.25 0.15 Injector F For 7-inch Tanks LWR6057 0.11 0.50 0.09 0.07 0.03 0.02 0.01 Injector G For 8-inch Tanks LWR6057 0.16 0.70 Injector H For 9-inch Tanks 0.18 0.80 Injector J For 10-inch Tanks 0.14 0.16 0.12 0.50 0.14 0.12 0.02 0.02 LWR6151 LWR6151 Injector K For 12-inch Tanks Injector L Softener Valve For 14-inch Tanks 1.20 0.25 1.50 1.00 0.80 0.15 1.25 1.00 0.75 0.50 0.25 LWR6151 LWR6164 *New injectors for high-efficiency regeneration sequence are standard with Logix Controllers. Backwash Flow Control Table Backwash Number** 7 8 9 10 12 13 14 Flow Rate (gpm) 1.3 1.7 2.2 2.7 3.9 4.5 5.3 Flow Rate (Lpm) 4.9 6.4 8.3 10.2 14.76 17.0 20.0 **Backwash flow controls sized for 5.0 gpm/ft 2

For More Information: Call GE Osmonics at (262) 238-4400 or (800) 279-9404, or visit www.gewater.com North American Sales Euro/Africa Operations Asia/Pacific Operations 5730 N. Glen Park Road 230 rue Robert Schurman 1044/8 SOI 44/2 Milwaukee, WI ZA des Uselles Sukhumvit Road Parkanog 53209-4403 F-77350 Le Mée sur Seine Bangkok 10110 USA FRANCE THAILAND (262) 238-4400 Phone +33 1 64 10 2000 Phone +66 2 38 14213 Phone (262) 238-4402 Fax +33 1 64 10 3747 Fax +66 2 39 18183 Fax Corporate Headquarters: 5951 Clearwater Drive, Minnetonka, MN 55343-8995 (952) 933-2277 Phone Copyright 2004 GE Osmonics, Inc. Printed in USA, P/N 1238415 Rev. A