Declaration of Conformity

Similar documents
WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

DC POWER SUPPLY ALIMENTATION C.C.

Declaration of Conformity

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

SAFETY TERMS AND SYMBOLS

DC POWER SUPPLY (Switching mode)

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Switching DC Power Supply

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Digital/Analog Megohmmeter Model 1026

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Advanced Test Equipment Rentals ATEC (2832)

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Triple Output Power Supply

362 Clamp Meter. Users Manual

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Rental Industry Safety Tester Safe Check 5s

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Digital/Analog Megohmmeter Model 1026 USER MANUAL

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

1.Safe testing IMPORTANT:

User's Manual Digital High Voltage Insulation Tester Model

Digital Multimeter User's Manual

DIGITAL RCD(ELCB) TESTER

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

OPERATING INSTRUCTION

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

Autoranging Industrial Multimeter

362 Clamp Meter. Users Manual

EPS/ELA-Series User Manual EPS/ELA 250W

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

USER MANUAL. Insulation Tester + DMM. Model MG320

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

OPERATING INSTRUCTION

365 Detachable Jaw True-rms Clamp Meter

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

Model UT601: OPERATING MANUAL

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

True RMS Autoranging Multimeter

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

BATTERY OPERATED DIGITAL MILLI-OHMMETER

OPERATING INSTRUCTIONS

Autoranging Multimeter

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

OPERATING INSTRUCTIONS

Non-Contact Phase Rotation Tester

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

User s Manual Power Supply IM E. 5th Edition

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

80 Series V Digital Multimeter Safety Information

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

Safety design conforming to the following provisions

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

User Guide. Model Insulation Tester / Megohmmeter

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

DIGITAL MULTIMETER INSTRUCTION MANUAL

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

SLA Battery Capacity Analyzer

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

KMP Insulation-Continuity Tester. Users Manual

i400s Calibration Information Introduction

373 Clamp Meter. Users Manual

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA KEWTECH

MINI MCR-SL-UI-UI(-SP)(-NC)

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

DC REGULATED POWER SUPPLY

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

Instruction Manual. Model 310 Digital Milli-Ohm Meter

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Date received into service; / /.

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

Users Manual. Phase Rotation Indicator

Model Insulation Tester / Megohmmeter. User Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Safety design conforming to the following provisions

Battery Charger JCB- SCH20LI.2

Table of Contents Title Page No.

Transcription:

We Declaration of Conformity GOOD WILL INSTRUMENT CO., LTD. No. 7-1, Jhongsing Rd, Tucheng City, Taipei County 236, Taiwan GOOD WILL INSTRUMENT (SUZHOU) CO., LTD. No.69 Lushan Road, Suzhou New District Jiangsu, China. declares that the below mentioned product GOM-801H are herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Law of Member States relating to Electromagnetic Compatibility (89/336/EEC, 92/31/EEC, 93/68/EEC) and Low Voltage Equipment Directive (73/23/EEC, 93/68/EEC). For the evaluation regarding the Electromagnetic Compatibility and Low Voltage Equipment Directive, the following standards were applied: EMC EN 61326-1: Electrical equipment for measurement, control and laboratory use EMC requirements (1997+A1: 1998 +A2:2001+A3:2003) Conducted and Radiated Emission EN 55011: 1998+A1:1999 + A2:2002 Group I class B Current Harmonic IEC 61000-3-2: 2000 Voltage Fluctuation IEC 61000-3-3: 1995+A1:2001 ------------------------- ------------------------- ------------------------- ------------------------- Electrostatic Discharge IEC 61000-4-2: 2001 Radiated Immunity IEC 61000-4-3: 2002+A1:2002 Electrical Fast Transients IEC 61000-4-4: 1995+A1:2001+A2:2001 Surge Immunity IEC 61000-4-5: 2001 Conducted Susceptibility IEC 61000-4-6: 2001 Power Frequency Magnetic Field IEC 61000-4-8: 2001 Voltage Dips/ Interrupts IEC 61000-4-11: 2004 Safety Low Voltage Equipment Directive 73/23/EEC & amended by 93/68/EEC IEC / EN 61010-1: 2001 CONTENTS PAGE 1. PRODUCT INTRODUCTION...1 2. SPECIFICATIONS...2 3. PRECAUTIONS BEFORE OPERATION...4 3-1. UNPACKING THE INSTRUMENT...4 3-2. LINE VOLTAGE...4 4. PANEL INTRODUCTION...5 5. CIRCUIT DESCRIPTION...7 6. OPERATION INTRODUCTION...9 6-1. PRELIMINARY OPERATION...9 6-2. MEASUREMENT OF RESISTOR...9 6-3. MEASUREMENT OF SWITCH...10 7. MAINTENANCE...11 7-1. LINE FUSE REPLACEMENT...11 7-2. CLEANING...11 i

SAFETY TERMS AND SYMBOLS FOR UNITED KINGDOM ONLY These terms may appear in this manual or on the product: WARNING. Warning statements identify condition or practices that could result in injury or loss of life. NOTE: This lead/appliance must only be wired by competent persons WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are colored in accordance with CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. WARNING: This equipment is not for measurements performed for CAT II, III and IV. The following symbols may appear in this manual or on the product: the following code: Green/ Yellow: Earth Blue: Neutral Brown: Live (Phase) As the colors of the wires in main leads may not correspond with the colors marking identified in your plug/appliance, proceed as follows: The wire which is colored Green & Yellow must be connected to the Earth terminal marked with the letter E or by the earth symbol or colored Green or Green & Yellow. DANGER ATTENTION Protective Earth(ground) High Voltage refer to Manual Conductor Terminal Terminal The wire which is colored Blue must be connected to the terminal which is marked with the letter N or colored Blue or Black. The wire which is colored Brown must be connected to the terminal marked with the letter L or P or colored Brown or Red. If in doubt, consult the instructions provided with the equipment or contact the supplier. ii iii

This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, cable of 0.75mm 2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used. Any mounded mains connector that requires removal /replacement must be destroyed by removal of any fuse & fuse carrier and disposed of immediately, as a plug with bared wires is hazardous if a engaged in live socket. Any re-wiring must be carried out in accordance with the information detailed on this label. 1. PRODUCT INTRODUCTION The Digital Milliohm Meter features with its accuracy and readability. The circuit of this instrument has equipped with the voltage regulator and temperature compensation in order for its accuracy not to be influenced by the unstable AC power source and the alternation of temperature. The Digital Milliohm Meter is specially produced for the manufacturers of the low resistor, switch, relay, jacks, plugs, connectors sockets or the electrolytic capacitor for the QC or IQC purpose, it also can be applied to measure the initial contact resistance. iv 1

2. SPECIFICATIONS The specifications are operated under the essential conditions as follows: A 1-year calibration cycle. An operating temperature of 18 to 28 (64.4 to 82.4 ). Relative humidity not exceeding 80%. Accuracy is expressed as ±(percentage of reading + digits). The instrument requires 30 minutes warm-up time to achieve rated accuracy. Meter Test Current Hi/Go/Lo Compare 0.5% Accuracy Test Ranges Accuracy 3 1/2 Digital Panel Meter. 10uA, 100uA, 1mA, 10mA, 0.1A, 1A Accuracy:0.2% 20, 200mΩ, 2, 20, 200Ω, 2, 20kΩ totally 7 full scale ranges. ±0.2% rdg+4 digits(±0.2% rdg+6 digits for 20mΩ range only) Range Current 20, 200mΩ 1A 2Ω 0.1A 20Ω 10mA 200Ω 1mA 2kΩ 100μA 20kΩ 10μA Environment Operation Environment Indoor use, altitude up to 2000m. Ambient Temperature 0 to 40. Relative Humidity 80% (Maximum). Installation category II Pollution Degree 2 Storage Temperature -10 to 70. General Power source AC 100V/120V/220V/230V±10%, 50/60Hz, 25VA Accessories Test Lead 1, Instruction manual 1 Dimension 245(W) 95(H) 280(D) m/m Weigh Approx. 2 kg WARNING : To avoid electrical shock, the power cord protective grounding conductor must be connected to ground. CAUTION:To avoid damaging the instrument, do not use it in a place where ambient temperature exceeds 40. CAUTION : The maximum input voltage on the testing terminal is limited at +10V DC. Besides, do not input the voltage reversely. 2 3

3. PRECAUTIONS BEFORE OPERATION 4. PANEL INTRODUCTION 3-1. Unpacking the Instrument The product has been fully inspected and tested before shipping from the factory. Upon receiving the instrument, please unpack and inspect it to check if there is any damage caused during transportation. If any sign of damage is found, notify the bearer and/or the dealer immediately. 3-2. Line Voltage WARNING. To avoid electrical shock the power cord protective grounding conductor must be connected to ground. AVERISS: Pour éviter les chocs électriques, le fil de terre du cordon secteur doit impérativement être relié à la terre. When line voltages are changed, replace the required fuses shown as below: Model Line voltage Range Fuse Line voltage Range Fuse GOM-801H 100V 120V 90-110V 108-132V TT0.3A 250V 220V 230V 198-242V 216-250V T0.2A 250V WARNING. To avoid personal injury, disconnect the power cord before removing the fuse holder. Figure 4-1. Front Panel 4 5

Front Panel 1. Power Switch Power on/off switch. 2. Range 7 steps: 20, 200mΩ, 2, 20, 200Ω, 2 and 20kΩ. 3. HI/LO Set the SET/TEST switch to SET position, then select HI/LO for high or low value setting. 4. SET/TEST This button can be used for testing or HI/LO value setting. 5. FORCE Terminal + Test terminal. 6. SENSOR Terminal + Test terminal. 7. SENSOR Terminal - Test terminal. 8. FORCE Terminal - Test terminal. 9. HI of Comparator Set For high value setting. 10. LO of Comparator Set For low value setting. 11. Panel Meter To indicate the test value. 12. HI Indicator This indicator will be lighted up when the test value is higher than the setting of high value. This indicator will be lighted up when the test 13. GO Indicator value between high and low setting. The buzzer will be sounded up 2~5 seconds when the GO indicator is on. 14. LO Indicator This indicator will be lighted up when the test value is lower than the setting of low value. 5. CIRCUIT DESCRIPTION DVM Circuit The DVM is an A/D converter by using IC U301. 10 or 100 Times Signal Amplifier The signal amplifier uses IC U401. Test Range selected buttons There are 7 steps of Test ranges to be selected. It will not affect its accuracy due to the alternation or temperature. Constant Current Source The circuit uses IC U201and U202 and transistors Q203 and Q204 to produce constant current. Comparator Set and HI, GO and LO Indicators The setting is consists of the resistors and the variable resistors. The comparator use IC U403 and U404. The HI, GO and LO indictors use transistors Q401~Q407. Voltage Regulator Circuit The power supply has regulated output of ±5V and ±15V voltage, which are regulated by using Q201, Q202 and Q301 resistors to control D201, D202 and D301 zener diodes. The +5V voltage regulator circuit uses IC U302 voltage regulator. 6 7

6. OPERATION INTRODUCTION VOLTAGE RANGE SELECTOR 6-1. Preliminary Operation 1. Set the power off. REGULATOR & MEASUREMENT 2. Make sure that line voltage is correct for the input power voltage. 3. Plug power cord into the power outlet. 4. Turn on the instrument and allow about 10 minutes of warm up time to CONSTANT CURRENT SOURCE TEST TERMINAL 10 OR 100 TIMES SIGNAL AMPLIFIER stabilize the instrument. 6-2. Measurement of Resistor SET REFERENCE COMPARATOR HI.GO.LO INDICATOR SET 3 1 / 2 DVM Fig. 6-1 TEST 1. Connect an unknown resistor to the test terminals as shown in Fig. 6-1. 2. Set the range to the position where the reading value can be obtained. Fig. 5-1 8 9

6-3. Measurement of Switch 7. MAINTENANCE Qualified personnel execute the following instructions only. To avoid electrical shock, do not perform any servicing other than the operating instructions unless you are qualified to do so. Fig. 6-2 1. Connect the switch to be tested as shown in Fig. 6-2. 7-1. Line fuse replacement If the fuse blows, the meter would not work. Try to determine and correct the cause of the blown fuse, then replace the fuse with correct rating and type shown as below: FUSE RATING AND TYPE 100/120V TT0.3A 220/230V T0.2A 2. Set the range to the position where the reading value can be obtained. WARNING: For continued fire protection, replace only with 250V fuse of the specified type and rating, and disconnect the power cord before proceeding fuse replacement. 7-2. Cleaning To keep the instrument clean, wipe the case with a damp cloth and detergent. Do not use abrasives or solvents. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 10 11