June 13, Dear Mr. Klauss,

Similar documents
Energy Savings through Solar Energy for Municipalities

Alameda Unified School District

Lassen MUD PV BUYDOWN PROGRAM Photovoltaic Systems Guidelines

Steps to Installing Solar for Residential Customers

Should I Get a Solar Array for my House? The Regulations, Available Equipment, and Benefits Steven Johnson

Solar Seminar. July 21st, Barry Cinnamon

July 24, Project IR

Thomas Alston Director of Business and Policy Development. Presented By N. Scottsdale Rd, Suite 410 Scottsdale Arizona 85257

ALZ Electrical Solar Consumer Guide

Economics and Barriers to Solar Photovoltaic Applications in Barbados

Contents. Solar Select TM Frequently Asked Questions

Zero Emission Bus Impact on Infrastructure

24. SOLAR INCENTIVE PROGRAM II

Long Island Solar Installer Workshop

SDG&E Customer Distributed Generation Programs. Steve Jaffe Senior Market Advisor Customer Innovations Group September 14, 2009

Iowa Statewide Solar Readiness Initiative

Considerations for Municipal Solar Projects. Ben Frevert Larsen Engineers November 16, 2016

CUSTOMER OWNED SOLAR IN WISCONSIN

For the highest caliber solar system choose Rosendin Electric s exceptional collaborative team

The brand you can trust.

Solar for Schools. John E.P. Morrison

SOLAR FOR ALL (Rev. 5)

Solar*Rewards Frequently asked questions system size and customer usage

July 16, Dear Mr. Randolph:

COMMENTS OF COMMONWEALTH EDISON COMPANY ILLINOIS ADJUSTABLE BLOCK PROGRAM PV SYSTEM DISCLOSURE FORMS

Municipality Generator Interconnection Application Single Meter Application Part I

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

Application for Operation of & Net Metering for Member-Owned Generation Name: Mailing Address: City: County: State: Zip Code: _

Solar Electric Systems for Multi-Tenant Units. Presenters

Puget Sound Energy Overview

Schedule SP SOLAR PURCHASE (Experimental)

2012 DFW Solar Home Tour October 6, 2012 Reference Solar PV

City Title. . Is System Owner interested in being contacted about energy efficiency opportunities at this site? Title. City. Site Contact.

Shedding Light on S lar Overview of Solar Finance

All of Texas Has Excellent Solar Resources. United States Solar Installed (as of mid 2013): 10 GW Germany Solar Installed (end of 2013): 35.

SOLAR ELECTRIC INVESTMENT ANALYSIS

SOLAR DISTRIBUTED GENERATION PROGRAM UPDATE

HONORABLE CHAIRPERSON AND MEMBERS OF THE AZUSA UTILITY BOARD

Community Solar Projects: Glossary of Terms

Solarize Fairfax County Info Session. Agenda. Welcome Remarks by Chairman Bulova Remarks by Supervisor Gross Presentation by LEAP Q&A Session

A CONSUMER S GUIDE TO NET METERING AND SOLAR POWER IN MISSISSIPPI

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

Welcome To Meet Our Installer Event

Solar PV Projects PPA Model

FINANCIAL! Thanks. Solar Marketing & Payback. Agenda

Why are we here? To lead in creating more sustainable communities by making solar simple.

Net Meter and Production Meter installed by Xcel Energy

To: Honorable Public Utilities Board Submitted by: /s/ Barry Leska AGM Energy Resource Planning. From: Alan Hanger Approved by: /s/

Rate Impact of Net Metering. Jason Keyes & Joseph Wiedman Interstate Renewable Energy Council April 6, 2010

PG&E California Solar Initiative (CSI) & Net Energy Metering (NEM) Interconnection Webinar. March 26, 2009

Example 1MW Solar System for Fosters Yatala

Bill Johnson President Solar, Simply Brilliant.

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

Solar for Homeowners Getting Started with Solar

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

PV Systems Modeling and Analysis Tools

40KW Solar System for Apple Sauce Co

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

The Nuts and Bolts of Solar. June 13 th, 2015 San Mateo Public Library Oak Room 10 am An Educational Workshop On Solar And Energy Efficiency Faire

Analysis of Impact of Mass Implementation of DER. Richard Fowler Adam Toth, PE Jeff Mueller, PE

2015 Solar Summit. Jake Wade Net Metering Program Manager

Southern California Edison Rule 21 Storage Charging Interconnection Load Process Guide. Version 1.1

600kW Stand-Alone power system with cooling

California PUC Rule 21 Generating. Facility Interconnection Application Guide. Technical Note

REVISED 8/1/2018 SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & WGC INTERCONNECTION AGREEMENT

Unitil Energy Demand Response Demonstration Project Proposal October 12, 2016

Rhode Island Net Metering First Bill Walkthrough. Updated September 2017

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23

Sell Solar TODAY with Solar in a Box

Requirement Definition/Terms of Reference Satellite Beach City Hall - Solar Array Installation

REQUEST FOR PROPOSALS (RFP) FOR THE PURCHASE OF SOLAR ENERGY

Renewable Net Metering Program Appendix ESD APX 001 1

SUMMARY OF TOTAL CURRENT PRICES - ELECTRIC

JEA Distributed Generation Policy Effective April 1, 2018

REVISION NO.: 7 EFFECTIVE: 07/07/16

Market Drivers for Battery Storage

2012 INSTALLERS MEETING UES INSTALLER S MEETING

FINAN CIAL E VALUATIO NS O F R E TR O FIT S OLAR ELE C TRIC H OME S Andy Black OnGrid Solar, Member of the CalSEIA. Attractive E conomics

Designing Stand Alone Systems. Overview, components and function, Elements in Design

SOLAR FEASIBILITY STUDY

RATE 765 RENEWABLE FEED-IN TARIFF

Bihar Electricity Regulatory Commission Vidyut Bhawan, J.L.Nehru Marg, Patna

Consumer guide. be brighter. actewagl.com.au/solar

Schedule D DOMESTIC SERVICE

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

a) The 2011 Net Metering and Buyback Tariff for Emission Free, Renewable Distributed Generation Serving Customer Load

PUBLIC SERVICE COMMISSION OF WEST VIRGINIA

Commercial Solar Opportunities. Kevin Moore Koch

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Community Solar Discussion

Project Title: Lowertown Ballpark (CHS Field) Solar Arrays Contract Number: EP4-34 Milestone Number: 1 Report Date: June 21, 2016

SolarPACE + Storage Expanding Opportunities and Improving Project Economics. Presented By:

Electrical District No. 3 SOLAR Q & A

Project Title: Contract Number: Milestone Number: Report Date: Contract Contact: Phone: Congressional District: Executive Summary:

Grasshopper Vision. Accelerate the adoption of sustainable practices by creating accessible and affordable products for everyone.

Transcription:

A Photovoltaic and Energy Storage Consultancy June 13, 2014 Martin Klauss, Assistant Superintendent Business and Administrative Services Oak Park Unified School District OPUSD 5801 Conifer Street, Oak Park, CA 91377. Dear Mr. Klauss, Please find attached my report analyzing the proposal that the OPUSD has received from SK Solar (Rev. 6-12/14) for a 155 kw photovoltaic system to be installed at Oak Park High School. My report follows the Scope of Work offered to you in my Proposal of May 12, 2014. Scope of Work: Predicted energy production Energy bill savings and Performance Based Incentive (PBI) Operation and maintenance responsibilities and costs Cash Flow including Net Present Value taking into account energy cost escalation, discount rate and inflation rate System configuration and equipment specification System orientation and location System monitoring (system operation, energy production, warnings and fault notification) Engineering, Procurement and Construction schedule Milestones and Progress Payment Equipment and workmanship warranties Non-energy benefits Educational opportunities based on monitoring, system performance history and projections, environmental (non-energy) benefits, based on web access and browserbased tools Sincerely yours, Peter T. Parrish, Ph.D., President SolarGnosis 1107 Fair Oaks Ave. South Pasadena, CA 91030 petertor@pobox.com (323) 839-6108

Technical and Cost Analysis of "Solar Energy Engineering, Procurement and Construction Agreement" (Rev. 6-12-14) by SK Solar Inc. Preface The principal focus of this report is a comparison of the quoted costs to own and operate a 155 kw stc solar electric system and the savings estimated by the vendor. These savings include cash incentives (rebates) from the State of California and reductions in the electricity bill realized by the production of electricity by the solar electric system. Properly estimating electricity production requires the specification of the solar electric equipment, the orientation and placement of the solar panels, and the geographic location of system. It also requires a detailed understanding of the electricity rates of Southern California Edison, the electrical utility. This report will rely on a solar electric simulation tool the CSI EPBB Calculator which is capable of calculating energy production and rebates. Energy bill savings will be calculated by comparing the electricity bill with and without the solar electric system. The period of this analysis is 25 years. The costs include the acquisition costs, based on a 120 month loan at 4.25%, the operation and maintenance costs, and out-of-warranty equipment maintenance costs. Specification of Solar Electric System The solar electric system is comprised of two separate systems, a 59.26 kw stc roof mount system and a 95.20 kw stc ground mount system. 59.26 kw stc Roof Mount System 214 each SolarWorld SW280 mono PV modules 2 each Solectria PVI 23TL inverters Roof mounted, with a 3" to 6" clearance 15 degrees PV module tilt 180 degrees azimuth Location: 899 N. Kanan Rd., Oak Park, CA, 91377 95,200 kw stc Ground Mount System 340 each SolarWorld SW280 mono PV modules 4 each Solectria PVI 23TL inverters Ground mount, >6" clearance 15 degrees PV module tilt 180 degrees azimuth Location: 899 N. Kanan Rd., Oak Park, CA, 91377 Comments on These Systems The specified PV module tilt angle for both systems is 15 degrees. If the roof pitch is 15 degrees, the module tilt angle is okay (i.e. the PV system is "flush mounted"). If the roof is (essentially) flat, a 15 degree pitch will require considerable inter-row spacing and a site survey is recommended to insure that adequate roof space exists for this system.

Furthermore, a 15 degree PV tilt angle is technically challenging for a shade structure, with 9-14 degree PV modules tilts more common. Since the choice of tilt angle affects the electricity production, the tilt angle for the ground mount needs to be confirmed. It is recommended that a site survey be performed to determine among other matters the most appropriate PV module tilt angle for both the roof mount and ground mount systems. No monitoring system has been specified. The monitoring system is an essential component supporting Operation and Maintenance, as a monitoring system will provide remote, near-realtime measurements of system performance, fault detection and indication, and display of error codes. It will also be a crucial part of any educational program. A complete specification of the hardware, integration into the rest of the system, and functionality should be negotiated and incorporated into the Agreement. CSI EPBB Simulation The California Energy Commission "CSI PV Calculator" must be used in conjunction with a PBI rebate application. This calculator is in turn is based on the National Renewable Energy Laboratory's (NREL's) PVWatts v.2 calculator. The use of 2 each Solectria PVI 20TL inverters on the 59.26 kw stc Roof Mount System will probably result in inverter overload, and the CSI calculator will not allow the use of this combination of PV modules and inverters. In other words, this combination of PV modules and inverters does not qualify for a PBI rebate. Using 2 each of the PVI 23TL or PVI 28TL inverters result in the same annual energy production 93,075 kwh. Accordingly, the PVI 23TL will be used for further benchmarking of the 59.26 kw stc Roof Mount System. The use of 4 each Solectria PVI 20TL inverters on the 95,200 kw stc Ground Mount System result in an annual energy production of 147,121 kwh, while the use of 4 each PVI 23TL inverters results in an annual energy production of 148,672 kwh. This latter choice will result in a 1.0% increased PBI rebate and a 1.0% increase in energy bill savings. The PVI 23TL inverter will cost more to purchase, so an analysis as to which choice is more cost effective will not be done at this time. Accordingly, the PVI 23TL will be used for further benchmarking of the 95,200 kw stc Ground Mount System. No accounting for shading has been performed because no shading data is available at this point in time. A detailed shading analysis should be performed, as part of a Site Survey and the impact on energy production and the PBI rebate should be taken into account. Results of the CSI EPBB simulations Attached are the energy production predictions based on CSI EPBB simulations of each system using SolarWorld SW280 mono PV modules and Solectria PVI 23TL inverters. In summary, 59.26 kw stc Roof Mount System: 93,075 kwh/1st year, PBI rebate $53,053 total (based on $0.114/kWh, and payable in five equal, yearly increments). 95,200 kw stc Ground Mount System: 148,672 kwh/1st year, PBI rebate $84,743 total (based on $0.114/kWh, and payable in five equal, yearly increments).

155,460 kw stc Ground Mount System: 241,747 kwh/1st year, PBI rebate $137,796 total (payable in five equal, yearly increments). Exhibit M of the SK Solar Agreement shows an energy production of 254,901 kwh/1st year (5.4% greater estimate than my estimate), and a total PBI rebate of $138,197 (0.2% greater than my estimate). A 2% error in energy production estimates and PBI rebate are not significant, in my opinion. Predicted Energy Bill Savings This is a complicated calculation because Oak Park High School is on a Time of Use TOU-8- B-APS tariff. This means that rate for electricity varies during the time of day, whether the day in question is a "weekday" or a "weekend/holiday" and seasonally (eight "Winter" months and four "Summer" months). Taking these various factors into account results in the following 1st year energy bill savings: 59.26 kw stc Roof Mount System: $6,922 An average of $0.073/kWh 95.20 kw stc Ground Mount System: $10,898 An average of $0.073/kWh 155.46 kw stc System $17,720 An average of $0.073/kWh Exhibit M of the SK Solar Agreement shows a first year energy bill savings of $22,941 for an average of $0.090/kWh. This is 29.4% greater than my estimate. This difference is quite significant, in my opinion. I have checked my calculations and I believe that they are consistent with the SCE rates for TOU-8-B-APS. Other Cost Elements The SK Solar proposal does not include any estimates for Operation and Maintenance expenses. I would include an annual O&M expense of 0.5% of the purchase price or $2,630/yr. The SK Agreement does not specify a system monitor, although a conversation with Jonas Didzbalis at SK Solar confirmed that a system monitor will be included as part of the system. I recommend that a system monitor have the following functionality: Web hosted Reports system AC power total and for each inverter with no more than 15 minutes latency Stores and is able to display system energy production each hour for any day, each week, each month and each year. All information that is stored locally in each of the Solectria inverters, including fault conditions and error codes. Notification system (messaging, cell call or email) in case of out of specification operation or system faults.

EPC Agreement Sections 2.1: Contractor's Obligations, The Work Section 2.1(h). Delivery of these documents should be part of "Final Completion Certificate" Section 2.1(h). This training should be completed prior to "Final Completion Certificate" EPC Agreement: Sections 2.5 "Unanticipated Conditions" and Section 7.16 "Miscellaneous" Section 2.5. A Site Survey should be conducted prior to executing the Agreement in order to minimize the chances of discovery of existing on-site conditions that would significantly complicate or preclude Contractor from installing the proposed PV System. Section 7.16. The precautions mentioned in this section should include a Site Survey including the determination of location of underground utilities. EPC Agreement Sections 2.12: Warranty As mentioned below, it should be the responsibility of the Contractor should "stand behind" any manufacturer's warranties. This includes the procurement, installation and certification of any equipment replaced under warranty by the Contractor, at no cost to the District. EPC Agreement Section 4: Commencement and Completion Paragraph 4.1(a) should read "...Exhibits A and C." EPC Agreement Exhibit A: Construction Schedule This schedule appears reasonable. EPC Agreement Exhibit C: Scope of Work This exhibit needs more detail. It should mention the SCE Interconnection Agreement and Permit to Operate. This Exhibit should be carefully reviewed together with Exhibit L "Definitions" and the definitions themselves may need to be modified EPC Agreement Exhibit E: Schedule of Values a/k/a Milestones and Progress Payments In general, the milestones lack sufficient detail to understand if progress and deliverables have been achieved. I suggest the following payment percentages and progress/deliverables for consideration: 10%: down payment 10%: Delivery of Final-Build-to plans and approval of same by District 20%: Securing Ventura County building/electrical permit and SCE Interconnection Agreement 35%: Delivery of substantially all equipment 15%: "Substantial Completion" 10%: "Final Completion Certificate" to include o Sign-off by Ventura County building/electrical permit o Receipt of any "as built" corrections approved by Ventura County o Approval by SCE of Interconnection Agreement o Receipt of SCE Permit to Operate o Delivery of Commissioning Report o Delivery of "Owner Manual" containing documentation of all major equipment items, operation and maintenance manuals for all major equipment

items, warranties, details of connection of monitoring system to local area network, web hosting, and functionality of monitoring system. Any changes to the milestones and progress payments will need to be reflected in Exhibits C Scope of Work and Exhibit L "Definitions". EPC Agreement Exhibit H: Warranties SK Solar's workmanship warranty should provide for timely repair/replacement of any defects in workmanship and a time period for such repair/replacement should be specified in the Agreement. It is recommended that SK Solar to "stand behind" all manufacturer's warranties. This means that SK Solar would procure, install and certify any equipment that is replaced under any manufacturer's warranty, at no cost to the District. EPC Agreement Exhibit M: Estimated Production and Savings As mentioned above, I recommend that this document be revised as follows: Estimated electricity production 241,747 kwh/1st year (0.5% annual decrease in energy production) PBI rebate $137,796 total (payable in five equal, yearly increments). Predicted energy bill savings of $17,720 (with an annual escalation of 3.9%) Annual O&M costs of $2,630 1st year with an annual inflation rate of 2.0% Discount rate of 5.1% I have included a spreadsheet, based on a spreadsheet provided by SK Solar, showing the Cash Flow for 25 years. Non energy Benefits This work element applies to a Prop 39 procurement and is not within the scope of this report. Educational Opportunities In terms of negotiating the Agreement, OPUSD stakeholders should have an opportunity to weigh in on the functionality of the monitoring system, in terms of interface and functionality. This may require specific hardware or specific features to be included in the monitoring system.

Oak Park High School Cash Flow Analysis., Project Summary Customer Name Oak Park Unified Year Installer Name SK Solar City, State Oak Park, California 1 241,747 ($526,078) ($65,000) $0.073 $17,648 $27,559 ($56,678) ($2,630) ($79,102) ($79,102) 2 240,538 $0.076 $18,244 $27,421 ($56,678) ($2,683) ($13,695) ($92,797) System Summary 3 239,336 $0.079 $18,861 $27,284 ($56,678) ($2,737) ($13,270) ($106,067) Proposed System Size (kw DC) 155.46 kwstc 4 238,139 $0.082 $19,498 $27,148 ($56,678) ($2,791) ($12,823) ($118,890) Solar Modules SolarWorld 5 236,948 $0.085 $20,158 $27,012 ($56,678) ($2,847) ($12,355) ($131,245) System Mounting Type Rooftop and Ground Mount 6 235,763 $0.088 $20,839 ($56,678) ($2,904) ($38,743) ($169,988) Estimated Yr. 1 Output (kwh) 241,747 7 234,585 $0.092 $21,543 ($56,678) ($2,962) ($38,097) ($208,085) 8 233,412 $0.095 $22,272 ($56,678) ($3,021) ($37,428) ($245,513) Tax Assumptions 1 9 232,245 $0.099 $23,025 ($56,678) ($3,082) ($36,735) ($282,248) Investment Tax Credit $0 10 231,083 $0.103 $23,803 ($56,678) ($3,144) ($36,019) ($318,267) Federal Tax Rate 0% 11 229,928 $0.107 $24,608 ($3,206) $21,401 ($296,866) State Tax Rate 0.00% 12 228,778 $0.111 $25,440 ($3,271) $22,169 ($274,697) 13 227,634 $0.116 $26,300 ($3,336) $22,964 ($251,733) Cash Purchase Summary 14 226,496 $0.120 $27,189 ($3,403) $23,786 ($227,947) 25 Yr Total Savings $96,938 15 225,364 $0.125 $28,108 ($3,471) $24,637 ($203,310) Incentives $0.114/kWh PBI for 5 yrs 16 224,237 $0.130 $29,058 ($3,540) $25,518 ($177,793) Purchase Price Calculations 17 223,116 $0.135 $30,040 ($3,611) $26,429 ($151,363) Purchase Price $466,500 18 222,000 $0.140 $31,056 ($3,683) $27,372 ($123,991) Add on for Bonding and Prevailin $23,000 19 220,890 $0.145 $32,105 ($3,757) $28,349 ($95,642) Sales Tax $36,578 20 219,786 $0.151 $33,191 ($3,832) $29,359 ($66,283) Total $526,078 21 218,687 $0.157 $34,313 ($3,909) $30,404 ($35,879) 22 217,593 $0.163 $35,473 ($3,987) $31,486 ($4,393) Output (kwh/kwstc/day) 4.26 23 216,505 $0.169 $36,672 ($4,067) $32,605 $28,212 Cost ($/Wstc) $3.39 24 215,423 $0.176 $37,912 ($4,148) $33,764 $61,976 25 214,346 $0.183 $39,193 ($4,231) $34,962 $96,938 Assumptions * Utility Savings estimates are based SCE TOU 8 B APS tariff and an annual escalation of 3.9% 3.90% * Annual decrease in electricity production is 0.5% * Annual Inflation is 2.0% * Discount rate is 5% * Interest Rate is 4.25% * Estimated Operation and Maintenance Expense as a percentage of purchase price * Production values are based on the CSI EPBB Calculator Est. System Production (kwh) Cash Purchase Amount 0.50% 2.00% 5.00% 4.25% 0.50% Down Payment Est. Utility Rate Est. Utility Savings Est. Performance Based Incentives Est. Finance Payment Estimated Operation & Maintenance Expense Est. Annual Cash Flow Est. Cumulative Cash Flow