LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Similar documents
PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

PY-11 Voltage & Continuity Tester

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

THWD-3 and TH-3 Relative Humidity and Temperature Meters

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

KMP Insulation-Continuity Tester. Users Manual

TIME-10 Process Control Stopwatch

TACH-10 Contact / Non-Contact Tachometer

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

TMA5 Mini Vane Anemometer

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

TMD90A Dual Input Digital Thermometer

INSP-3 Wiring Inspection Tester

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

KMP7010. Ground Resistance Tester. Users Manual

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

362 Clamp Meter. Users Manual

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

323/324/325 Clamp Meter

302+/303 Clamp Meter. Users Manual

365 Detachable Jaw True-rms Clamp Meter

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Users Manual. Phase Rotation Indicator

362 Clamp Meter. Users Manual

Visit us at

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

373 Clamp Meter. Users Manual

i400s Calibration Information Introduction

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

i3000s/i2000 Flex AC Current Probe

Low Amp Probe EETA308A

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Operator s Manual TC-253A. Temperature Converter

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:


INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

233 True-rms Remote Display Digital Multimeter Safety Information

712 RTD Calibrator. Instruction Sheet. Introduction

Calibration Manual. Detachable Jaw True-rms Clamp Meter

716 Pressure Calibrator

Go to to register your product and find more information.

Users Manual. Airflow Meter

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Users Manual. MegOhmMeter

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

Infrared Thermocouple Probe

718 30G/100G. Users Manual. Pressure Calibrator. 99 Washington Street Melrose, MA Phone Toll Free

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

CO2-100 CO2 Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

1000FLT. Users Manual. Fluorescent Light Tester

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

80PK-2A Type K Immersion Probe


MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Defender 3000 Series Base Instruction Manual

SOIL RESISTIVITY TESTER

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

4-20mA DC PROCESS CLAMP METER

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

User's Manual. Earth Ground Resistance Tester. Model Introduction

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

Tachometer. English. Users Manual

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

Declaration of Conformity

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

This manual covers the following model:

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

ICA 39T INSTRUCTION MANUAL ICA39T AC/DC CURRENT TRANSDUCER

Cable Length Meter INSTRUCTION MANUAL

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

INSTRUCTION MANUAL DM5B Fax: (503)

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Installation / Operation Instructions Sunnex ORION Series Exam Lights

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

Phase Sequence Tester

Transcription:

LH41A Clamp On Ammeter User Manual For detailed specifications and ordering info go to www.testequipmentdepot.com

LH41A Clamp On Ammeter Users Manual English April 2007, Rev.2 2007 Amprobe Test Tools. All rights reserved. Printed in China

Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Repair All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Nonwarranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe Test Tools. In-Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product. Non-Warranty Repairs and Replacement US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates.

W T P n, International Electrical Symbols Caution! Refer to this manual before using the meter Meter is protected by Reinforced or Double Insulation Complies with EU directives Indicates this equipment should for disposal be seperated as Waste Electrical and Electrical Equipment according to the EU directive 2002/96/EG Indicates item is a Type A Current sensor and that application around removal from HAZARDOUS LIVE conductors is permissible CONTENTS Page 1 INTRODUCTION... 2 2 SPECIFICATIONS... 3 2.1 Electrical Data... 3 2.2 General Data... 3 3 OPERATING INSTRUCTIONS... 4 3.1 Switch On... 4 3.2 Zero Adjustment... 4 3.3 Current Measurement... 4 3.4 Data Hold... 4 3.5 Auto Power Off... 4 4 SAFETY... 5 5 BATTERY REPLACEMENT... 6 6 WARRANTY... 6 7 OTHER PRODUCTS... 7

INTRODUCTION The LH41A current clamp meter has been designed for reliable and accurate non-intrusive measurement of DC and AC currents using advanced Hall Effect technology. Measurement features include: Non - intrusive AC and DC current measurement 1mA resolution Average responding, RMS calibrated Autoranging/ Autozeroing Data Hold Low battery indicator Auto Power Off AUTO ZERO OFF DC AC 40A HOLD LH 41A Fig. 1 2

SPECIFICATIONS 2.1 Electrical Data (All accuracies stated at 23 C ± 1 C) LH41A Measuring Range... 0-40 A DC or AC pk Autoranging... 4A / 40A Resolution... 1 ma in 4 A range 0 ma in 40 A range Accuracy Basic Accuracy... ± 1.3% + 5 digits Temperature coefficient... ± 0.05% of rdg / C Frequency range... DC in DC 0 Hz to 400 Hz in AC Overload capacity... 150 A Dielectric strength... 3.7 kv RMS. 50 Hz 60s (EN61010-2-032 Cat III, 300V Pollution Degree 2) 2.2 General Data Operating temperature... 0 C to + 50 C Storage temperature with Battery removed... - 20 C to + 60 C Power supply... 9 V, Alkaline battery PP3, NEDA 1604 or IEC6LR61 Battery life... 15 hours dependent duty cycle Display... 4000 count Characters... 10 mm high Mechanical LH41A Dimensions... 184 x 71 x 31 mm (7.2 x 2.8 x 1.2 in.) Max. jaw capacity... 19 mm ø cable Max. jaw opening... 20 mm (.78 in.) Weight... 235 g (1.2 Lb) 3

OPERATING INSTRUCTIONS Refer to Fig. 1 for the main operating features of the meter. 3.1 Switch On Move the switch from the OFF / HOLD position to either DC or AC to select the required mode of operation. 3.2 Zero Adjustment When in DC mode the display zero may change due to thermal shifts and other environmental conditions. An auto zero adjustment is provided. Proceed as follows to perform the adjustment: Ensure that the instrument is away from the current carrying conductor and that the jaws are closed during the adjustment cycle. Select the DC position of the power switch. Use the auto zero button to zero the display if necessary. The auto zero button can be used to null the effects of the earth s magnetic field on DC measurements. 3.3 Current Measurement Select as required the DC or AC measurement option using the power switch. If necessary adjust the DC display to read zero as described in section 3.2. Clamp the jaws of the instrument around the conductor ensuring a good contact between the closing faces of the jaws. Observe and take measurements as required. Positive output indicates that the current flow is in the direction shown by the arrow on the instrument. 3.4 Data Hold To activate the data hold, turn the power switch to the OFF / HOLD position. The data will be held on the display for approximately 10 seconds. 3.5 Auto Power Off The meter will power down automatically after approximately 8 minutes of inactivity.

SAFETY This product conforms to the latest directives concerning safety and electromagnetic compatibility. European Low Voltage Directives 73/23/EEC and 93/68/ EEC European EMC Directives 89/336/EEC and 93/68/EEC Safety Standards BSEN61010-1: 2001. General Requirements. Safety requirements for electrical equipment for measurement, control and laboratory use. BSEN61010-2-032: 2002. Particular requirements for hand held current clamps for electrical measurement and test. EMC Standards RF Susceptibility EN50082-1: 1992 3V/m Residential, Commercial and Light Industry RF Emissions EN50081-1: 1992 Residential, Commercial and Light Industry FCC Part 15 Class B This product is designed to be safe under the following conditions: indoor use altitude up to 2000m temperature 0 C to +50 C maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 40% relative humidity at 50 C. Use of the meter on uninsulated conductors is limited to 300V RMS or DC and frequencies below 1kHz. This meter complies with the requirements of the above safety standard for 300V Cat III Pollution degree 2 Safety in its use is the responsibility of the operator who must be a suitably qualified or authorised person. Users of this equipment and or their employees are reminded that Health and Safety Legislation require them to carry out valid risk assessments of all electrical work so as to identify potential sources of electrical danger and risk of electrical injury such as from inadvertent short circuits. 5

Do not use the instrument if any part of it appears to be damaged or if a malfunction of the instrument is suspected. When using the instrument ensure that your fingers are behind the protective barrier see Fig. 1 Clean the case periodically by wiping it with a damp cloth and detergent. Do not use abrasive cleaners or solvents. Do not immerse the instrument in liquids. BATTERY REPLACEMENT SAFETY WARNING Before removing the battery cover, make sure that the instrument is removed from any live electrical circuit. When the Low Battery symbol is illuminated in the display the minimum operating battery voltage has been reached. Refer to Fig.1. and use the following procedure to replace the battery. Unclamp the meter from the conductor, turn it off using the OFF / Hold power switch. Loosen the captive screw which secures the battery cover. Lift the cover through 30 and pull it clear of the instrument body as shown in Fig1. The battery is then accessible. Replace the battery and re-fit the battery cover and fasten the screw. Replacement with other than the specified type of battery will invalidate the warranty. Fit only Type 9 V PP3, Alkaline (MN1604 ). 6