Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

Similar documents
Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

METAL. consumer UNITS DOMESTIC CIRCUIT PROTECTION MANUFACTURED IN THE UK

Zucchini busbar ZUCCHINI DISTRIBUTION FUSE BOARD TAP-OFF

Consumer Units and the 17th Edition Product Focus. Meet the new regulations How to avoid confusion

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

XL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A

1.4. Product overview Memera consumer units and devices

New DX 3 High rating & breaking capacity

Residential and light commercial. invicta. panelboards

Underfloor to desk 231

COMPLETE SOLUTIONS FOR POWER PROTECTION

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

18TH EDITION BS7671 HOW THIS AFFECTS YOU. BITESIZE II. wylexreasons.co.uk WHY CHOOSE ANYTHING LESS?

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Electrak power track underfloor power distribution systems

Electrak powertrack / underfloor busbar system

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

Domae. The right solution for distribution boards

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Synergy WIRING ACCESSORIES / PRODUCT GUIDE

adaptable, reliable underfloor power

AThink future. Switch to green. XBoard Consumer Units. stylish and easy to fit.

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

DX³ RCCBs - ID 4P up to 100 A

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

ENYSTAR Load Centers up to 250 A

Underfloor Busbar. Betatrak Underfloor Busbar. 82

TX³ RCCBs 2P up to 100 A

DSE201 Compact design with enhanced protection

DX³ 4-pole RCBO 6000 A/10 ka

Vistop TM isolating switches 63 to 160A

XL Distribution enclosures WORKSHOP SPECIFICATIONS

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

BUSBAR TRUNKING SYSTEMS a

Consumer unit solutions to meet the demands of the new 17th edition regulations.

Electrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DX³ RCBO 6000 A Phase + Neutral, neutral right side

R.C.B.O. SP / 1 module

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

MCBs and RCDs LR TM 6000

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Safety Lampholders and Pendants

Solar Photo Voltaic Switchgear Solutions

A DIVISION OF TGC INTERNATIONAL LTD HIRE EQUIPMENT CATALOGUE

18 th Edition. Overload Protection of RCCBs and Switches within Consumer Units

DPX moulded case circuit breakers

Floor boxes... choice, flexibility and easy installation

WORKSHOP SPECIFICATIONS

City & Guilds 2381 Test 2382 Level 3. Which one of these electrical installations does BS 7671:2008 not apply to:

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

dx 3 protection that meets your requirements GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS catalogue pages inside

Low Voltage Assemblies

Distribution boards. 68 Q-DIN Range

Power Distribution Enclosures. Pillar shells and in-ground feeder pillars

Innovac SVS/08 - SVS/ kv modular switchgear

MR - MEDIUM RATING A

Swifts SW strength, speed and flexibility

Welcome to NORTH-WEST Welcome to a Stylish Sturdy & Safe world. PDF created with pdffactory trial version

RESIDUAL CURRENT CIRCUIT BREAKER

elevate your flexibility

1.2 Switched socket outlets with interlock

EVOline. Express. International socket versions available. Various colours available. Cascadable.Extendable. International.

Phase + Neutral, neutral on left side

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

The specifier s dream... the installer s delight

up to 63 A (1 module per pole)

Phase + Neutral, neutral on right side

P17. Tempra PRO. a range you can rely on CATALOGUE PAGES INSIDE. GLOBAL SPECIALIST in electrical and digital building infrastructures

Intelligent Choice for Prestigious Buildings

cavity floor service outlet boxes

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

DX³ RCBO 6000A Phase + Neutral, neutral on left

Swifts SW. strength, speed and flexibility STEEL WIRE CABLE TRAY / PRODUCT GUIDE

workshop specifications Plexo³ IP 65 cabinets

OMNIA System OMNIA SYSTEM - IP55 FLUSH AND SURFACE MOUNTING MODULAR SYSTEM. t. 50

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

BTPLUG 2 CATALOGUE 2009 BTP2_09TH

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

MoDPlus Din Distribution Boards

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

l Suitable for most residential, commercial and light industrial applications

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

FINAL-ER 42 Electrician Regulations Answer Schedule

PROBABLY THE BEST FLEXIBLE BAR IN THE WORLD

Low Voltage Systems. MNS BS - front & rear access switchboards Tested, tried & trusted solutions. Power and productivity for a better world TM

Korea Product Guide - Circuit Protection & Control X-Pole Series Miniature Circuit Breakers PL10 & PL9. Advanced design provides reliable protection

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Arena-Walsall power track system standard

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

Zucchini Low-Medium Power

(1,5 modules per pole)

Miniature Circuit Breakers. Bridging the gap

Transcription:

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

Summary of changes Simplifying the 17 th Edition Understanding new regulations is never easy... that s why we ve tried to make it as simple as possible. To comply with the 17 th Edition, we ve launched a selection of new dual RCD split load units with 10 or 16 outgoing ways. Regulation : 411.3.3 Summary : Regulation : 522.6.6 522.6.7 Summary : Socket outlets for general use in domestic installations require additional protection by an RCD* Cables buried in a wall or partition at a depth of less than mm and not mechanically protected by appropriate earthed metal require additional protection by an RCD* Regulation : 701.411.3.3 Summary : All circuits in locations containing a bath or shower shall be protected by one or more RCDs* Regulation : 314.1 Existing units can be easily upgraded for a 17 th Edition installation by replacing MCBs with RCBOs on unprotected ways. RCD* protection for increased safety, especially for the end-user in domestic installations... plus reduced likelihood of unwanted tripping by sensibly dividing the installation. Summary : All circuits of an installation should not be connected to a single upstream RCD* in order to avoid unwanted tripping, hazards and minimise inconvenience in the event of a fault * not exceeding 30 ma (*with a rated residual current not exceeding 30 ma - Reg. 415.1.1) 2

Dual RCD split load with dedicated main switch ways Select MCBs and RCBOs to complete installation Dual RCD split load Select MCBs to complete installation Split load Select MCBs and RCBOs to complete installation Main switch incomer Select RCBOs to complete installation RCD incomer (ideal for immersion heating) Select MCBs to complete installation 3

A flexible approach to safety With an array of design innovations and practical features making them easy to install, Legrand s consumer units save valuable time and money during installation... allowing you to reflect on the generous wiring space and the all-round extra protection. Features include a removable pan assembly, earth terminal holder that simply clips into place, and multiple cut-outs on the unit s back, bottom, top and sides. Combining elegance with efficiency Designed to match today s modern decor, the units offer a streamlined appearance allied with magnolia cases, allowing them to blend perfectly into their surroundings. The units are supported by a selection of residential DX-E MCBs, offering faster installation with a single fixing clip and simple labelling using the pre-scored, pre-printed labels supplied with each consumer unit. 4

Design innovations Simplifying installation and improving end user safety Rigid base with multiple cut-outs Removable terminal holders with screws in backed-off position Magnolia case with high fire retardancy. Self extinguishing at 7 C Clear, colour-coded labelling system Insulated shield Cut-to-length busbar for flexible on-site configuration Removable pan assembly Rail positioned for maximum cabling space Smoked transparent door with smooth closing action Complete safety and peace of mind for installer and end user alike 5

consumer units insulated and metal Insulated consumer units Conform to BS EN 60439-3. Magnolia colour. Smoked transparent door opens downwards Supplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plate Factory fitted link leads for both neutral and live connections. Configurable outgoing ways Self-extinguishing at 7 C. UL 94 V2 material for improved flame retardancy. Robust thermoplastic construction. 4 fixing holes Dimensions (p. 9-10) Dual RCD split load with dedicated main switch ways 100 A main switch and 2 x 80 A 30 ma RCD Dual RCD split load 100 A main switch and 2 x 80 A 30 ma RCD Split load 100 A main switch and 80 A 30 ma RCD Total outgoing ways 6 8 10 12 14 16 18 20 6075 74 6075 76 6075 54 6075 56 6075 32 6075 33 6075 34 6075 35 6075 36 Main switch incomer 100 A main switch 6075 11 6075 12 6075 14 6075 16 RCD incomer 80 A 30 ma RCD 6075 21 6075 22 Metal consumer units Conform to BS EN 60439-3. Magnolia colour. Smoked transparent door opens downwards Supplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plate Factory fitted link leads for both neutral and live connections. Configurable outgoing ways Pre-galvanised steel for strength and rigidity. Epoxy/polyester powder coated base and lid Dimensions (p. 10-11) Total outgoing ways 6 8 10 12 14 16 18 20 Dual RCD split load 100 A main switch and 2 x 80 A 30 ma RCD 6065 54 6065 64 (1) 6065 56 Split load 100 A main switch and 80 A 30 ma RCD 6065 32 6065 34 6065 36 Main switch incomer 100 A main switch 6065 11 6065 12 6065 14 6065 16 RCD incomer 80 A 30 ma RCD 6065 21 6065 22 (1) Flush mounting 6

protection devices MCBs and RCBOs DX-E residential MCBs - 6 ka Breaking capacity : 6 ka to BS EN 60898-1 DX-E residential MCBs - 6 ka Single pole - 230/400 V± RCBOs (combined MCB/RCD) Single pole and neutral - 240 V± RCBOs (combined MCB/RCD) Breaking capacity : 10 ka to BS EN 61009-1 RCD type AC conform to BS EN 61009-1 Terminal capacity : rigid conductor 35 mm 2 flexible conductor 25 mm 2 0032 70 6064 25 Nominal rating (In) Number of 17.5 mm modules B curve C curve Number of 17.5 mm modules B curve 30 ma C curve 6 A 1 0032 66 0033 82 1 6064 16 6064 22 10 A 1 0032 68 0033 84 1 6064 17 6064 23 16 A 1 0032 70 0033 86 1 6064 18 6064 24 20 A 1 0032 71 0033 87 1 6064 19 6064 25 32 A 1 0032 73 0033 89 1 6064 20 6064 26 40 A 1 0032 74 0033 90 1 6064 21 6064 27 A 1 0032 75 0033 91 1 6064 28 6064 29 63 A 1 0032 76 0033 92 7

consumer units insulated, metal and accessories 6075 74 6075 54 6065 54 Dimensions (p. 9-11) Conform to BS EN 60439-3. Magnolia colour. Smoked transparent door opens downwards Supplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plate Factory fitted link leads for both neutral and live connections. Configurable outgoing ways Insulated units : Self-extinguishing at 7 C. UL 94 V2 material for improved flame retardancy. Robust thermoplastic construction. 4 fixing holes Metal units : Pre-galvanised steel for strength and rigidity. Epoxy/polyester powder coated base and lid 8 Pack Cat. Nos. Insulated dual RCD split load with dedicated main switch ways - 16 module unit (8 + 2 ways available) 1 6075 74 With 100 A main switch and 2 x 80 A 30 ma RCD 22 module unit (13 + 3 ways available) 1 6075 76 With 100 A main switch and 2 x 80 A 30 ma RCD Insulated dual RCD split load - 16 module unit (10 ways available) 1 6075 54 With 100 A main switch and 2 x 80 A 30 ma RCD 22 module unit (16 ways available) 1 6075 56 With 100 A main switch and 2 x 80 A 30 ma RCD Insulated split load - 12 module unit (8 ways available) 1 6075 32 With 100 A main switch and 80 A 30 ma RCD 14 module unit (10 ways available) 1 6075 33 With 100 A main switch and 80 A 30 ma RCD 16 module unit (12 ways available) 1 6075 34 With 100 A main switch and 80 A 30 ma RCD 20 module unit (16 ways available) 1 6075 35 With 100 A main switch and 80 A 30 ma RCD 22 module unit (18 ways available) 1 6075 36 With 100 A main switch and 80 A 30 ma RCD Insulated with main switch incomer - 8 module unit (6 ways available) 1 6075 11 With 100 A main switch 12 module unit (10 ways available) 1 6075 12 With 100 A main switch 16 module unit (14 ways available) 1 6075 14 With 100 A main switch 22 module unit (20 ways available) 1 6075 16 With 100 A main switch Insulated with RCD incomer - 8 module unit (6 ways available) 1 6075 21 With 80 A 30 ma RCD 12 module unit (10 ways available) 1 6075 22 With 80 A 30 ma RCD Pack Cat. Nos. Metal dual RCD split load - 16 module unit (10 ways available) 1 6065 54 With 100 A main switch and 2 x 80 A 30 ma RCD 22 module unit (16 ways available) 1 6065 56 With 100 A main switch and 2 x 80 A 30 ma RCD Metal dual RCD split load - flush mounting 16 module unit (10 ways available) 1 6065 64 With 100 A main switch and 2 x 80 A 30 ma RCD Metal split load - 12 module unit (8 ways available) 1 6065 32 With 100 A main switch and 80 A 30 ma RCD 16 module unit (12 ways available) 1 6065 34 With 100 A main switch and 80 A 30 ma RCD 22 module unit (18 ways available) 1 6065 36 With 100 A main switch and 80 A 30 ma RCD Metal with main switch incomer - 8 module unit (6 ways available) 1 6065 11 With 100 A main switch 12 module unit (10 ways available) 1 6065 12 With 100 A main switch 16 module unit (14 ways available) 1 6065 14 With 100 A main switch 22 module unit (20 ways available) 1 6065 16 With 100 A main switch Metal with RCD incomer - 8 module unit (6 ways available) 1 6065 21 With 80 A 30 ma RCD 12 module unit (10 ways available) 1 6065 22 With 80 A 30 ma RCD Accessories Spare blank plate 20 6075 89 5 modules - magnolia colour Spare busbar 5 6075 99 21 prongs

protection devices MCBs and RCBOs insulated consumer units Insulated - dimensions (mm) A 110 B 0032 73 6064 16 Pack Cat. Nos. DX-E residential MCBs - 6 ka Breaking capacity : 6 ka to BS EN 60898-1 Single pole - 230/400 V± B curve C curve Nominal rating Number of (In) 17 5 mm modules 10 0032 66 0033 82 6 A 1 10 0032 68 0033 84 10 A 1 10 0032 70 0033 86 16 A 1 10 0032 71 0033 87 20 A 1 10 0032 73 0033 89 32 A 1 10 0032 74 0033 90 40 A 1 10 0032 75 0033 91 A 1 10 0032 76 0033 92 63 A 1 RCBOs (combined MCB/RCD) Breaking capacity : 10 ka to BS EN 61009-1 RCD type AC conform to BS EN 61009-1 Terminal capacity : rigid conductor 35 mm 2 flexible conductor 25 mm 2 Single pole and neutral - 240 V± B curve C curve Nominal rating Number of (In) 17 5 mm modules 30 ma 1 6064 16 6064 22 6 A 1 1 6064 17 6064 23 10 A 1 1 6064 18 6064 24 16 A 1 1 6064 19 6064 25 20 A 1 1 6064 20 6064 26 32 A 1 1 6064 21 6064 27 40 A 1 1 6064 28 6064 29 A 1 Modules A (mm) B (mm) 8 module unit 40 225 20 114 8 212 225 12 298 225 14/16 370 225 20/22 478 225 x 6 cut-outs 20 x 25 6 cut-outs 20 x 25 162 40 x 8 cut-outs 25 x 25 sides 20 x 25 12 module unit x 40 x 195 225 180 20 40 6 cut-outs 20 x 25 20 x 18. 5 2 25 x 20 sides 20 x 25 268 20 x 25 20 x 18. 5 9

insulated consumer units (continued) metal consumer units flush mounting 14/16 module unit x 40 x Metal - flush mounting dimensions (mm) A 113 min. B 20 40 10 cut-outs 20 x 25 30 cut-outs 25 x 20 sides 230 20 x 25 225 180 Modules A (mm) B (mm) 97 min. 132 max. 340 16 402 260 200 min. 234 max. 8 cut-outs 20 x 25 16 module unit 20/22 module unit 6 cut-outs Ø 20 40 20 x 40 x 372 260 120 Ø 20 sides 20 x 22 1 20 x 25 4 25 x 20 sides 20 x 25 84 84 2 obround cut-outs 100 x 225 180 448 340 20 x 22 10 cut-outs 20 x 25 4 cut-outs Ø 25 4 cut-outs Ø 32 10

metal consumer units Metal - dimensions (mm) A 113 16 module unit 4 cut-outs Ø 20 2 120 95 80 2 obround cut-outs 100 x 8 module unit 4 cut-outs Ø 32 100 4 cut-outs Ø 25 4 cut-outs Ø 32 95 80 1 obround cut-out 100 x 4 Ø 5 Ø 9 3 1 cut-out Ø 25 12 module unit 4 cut-outs Ø 32 175 1 obround cut-out 100 x 95 80 B Modules A (mm) B (mm) 8 219 235 12 305 235 16 377 235 22 485 235 200 175 22 module unit 4 cut-outs Ø 25 3 120 2 obround cut-outs 100 x 95 80 275 8 cut-outs Ø 20 4 cut-outs Ø 32 100 Ø 20 Ø 25 11

Powered by specialists The Legrand Group is the world s leading manufacturer of wiring devices and cable management systems. Through its specialist brands Bticino, Cablofil, Electrak, Ortronics and Zucchini, the Legrand Group also offers cutting edge solutions in door entry, connectivity and power distribution. Products and systems for electrical installations and information networks... a specialist in wiring devices, cable management, protection devices and industrial solutions. Tel: 0845 605 4333 Fax: 0845 605 4334 Email: legrand.sales@legrand.co.uk Web: www.legrand.co.uk Bticino systems present key developers with innovative and bespoke door entry solutions, supported by pre-sales design and enhanced service options. Tel: 0845 605 4333 Fax: 0845 605 4334 Email: bticino.uk@legrand.co.uk Web: www.bticino.co.uk A pioneer of the steel wire cable tray system, Cablofil is now one of the world s leading cable management brands for both data and power solutions. Tel: 0845 130 4628 Fax: 0845 130 4629 Email: salesuk@cablofil.com Web: www.cablofil.co.uk Electrak is a leading manufacturer of power distribution and lighting control solutions. Its power track, floor boxes, and desk modules are installed in high specification offices around the world. Tel: 01207 3400 Fax: 01207 1799 Email: sales@electrak.co.uk Web: www.electrak.co.uk Ortronics is a global leader in structured cabling systems, offering solutions for Cat 5e, Cat 6,10 Gig copper, fibre optic and high capacity installations. Tel: 0121 515 0669 Fax: 0121 515 0667 Email: info.ortronics-uk@ortronics.co.uk Web: www.ortronics.co.uk Zucchini offers comprehensive power distribution ranges, including busbar trunking systems from 25 A through to 6300 A and EdM cast resin transformers from 100 kva to 315 mva Tel: 0121 458 7070 Fax: 0121 459 7171 Email: zuk.info@btinternet.com Web: www.zucchini.uk.com Cablofil is part of the Legrand Group and operates independently in the United Kingdom. The Bticino, Cablofil, Electrak, Legrand, Ortronics and Zucchini logos are trademarks of the Legrand group of companies. Customer Services : Tel : 0845 605 4333 Fax : 0845 605 4334 E-mail : legrand.sales@legrand.co.uk Technical Support : Tel : 0870 608 9020 Fax : 0870 608 9021 E-mail : technical.uk@legrand.co.uk Head office : Legrand Electric Limited Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 Website : www.legrand.co.uk 02977 - Consumer unit product guide 01/2009.15K