Complete firing plants with silo, dosing machine, assembly and the commissioning. Reliable customer service. Service and assembly from one hand

Similar documents
D-GASIFIER. The ultimate solution for the replacement of gaseous and liquid fuels

MULTIFIRE. High temperature dual fuel burner

Setting the standard for today and tomorrow. Fundamental design features. Key benefits

Aggregate Drying Burners ASTEC AGGREGATE DRYING BURNERS. For Hot Mix Asphalt Facilities

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen

Combustion and Boiler Performance Assessment of Kardia Power Plant

Combustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels

NO TROUBLE WITH NOx AN ADVANCED CONCEPT FOR EFFECTIVE NO X REDUCTION

Technology Options for the Cement Industry with the Use of Alternative Fuels

C C A. Combustion Components Associates, Inc.

Power Generation Flexibilisation Case Studies from Germany. By Ronald Rost & Arun Kumar Sarna

Lecture 27: Principles of Burner Design

Eclipse Vortometric Burners Series HI

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

KINEMAX. Medium velocity gas or oil burners

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

Chapter 3 Combustion Systems & NOx

Towerpak Boiler. The versatile boiler to burn virtually any fuel economically

RAFAKO s proecological investments boilers and biomass installations

LOW NOx ROTARY KILN BURNER TECHNOLOGY : DESIGN PRINCIPLES & CASE STUDY

1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X

Steinmüller Engineering GmbH POWER-GEN Europe, Vienna

1070 SERIES ULTRA LOW NO X

Doing more for clean environment and energy saving

Automatic CFD optimisation of biomass combustion plants. Ali Shiehnejadhesar

TECHNICAL PUBLICATION

NOx-Beta Ultra Low NOx Burners

North American 4485 Tempest SE

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

Meeting the demand for high fuel flexibility: the Ansaldo Energia experience

IMPROVING PROFITS THROUGH ALTERNATIVE FUELS

Increased flexibility of refineries by O 2 enrichment. Sulphur recovery and new opportunities.

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH

Chapter 3. Combustion Systems & NOx. Editor s Note:

Eclipse RatioAir Burners

Mitsubishi Hitachi Power Systems America. Coal to Gas Conversions

PREMIX TUNNEL BURNERS

Mild Combustion of non-conventional and liquid fuels. Marco Derudi Dipartimento di Chimica, Materiali e Ingegneria Chimica / CFALab

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

Furnace-based optimisation of a lignite-fired steam generator

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

info NO x emissions <15 ppm 4LN version gas burners (with Flue Gas Recirculation) Information on Ultra Low NO x gas burners

ENERGY EFFICIENT DRIVE FOR COAL GRINDING MILLS

REDUXCO. combustion catalyst

The Marine Industry. The Offshore Industry MARKET SEGMENTS. Power Plants. Industry Plants. Transportable Containerized Incinerators

OPERATIONAL CRITERIA AND BURNER MODIFICATIONS FOR ACHIEVING LOW LOAD UNSUPPORTED COAL FIRING ON TANGENTIAL AND WALL-FIRED UNITS

Benefits of an air preheater replacement. Benefits of an air preheater replacement unit in a large CDU furnace

The Prime Glass DeNOx solutions in the present scenario of the glass industry NOx containment technologies

Dalamatic Dust Collectors

North American 4575 HiRAM

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

Experimental Study of LPG Diffusion Flame at Elevated Preheated Air Temperatures

DATA SHEET. Model: TG3 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

UPDATED LOW NOx COMBUSTION TECHNOLOGIES FOR BOILERS, 2003

Retrofitting of Mitsubishi Low NOx System

Emission Reduction Program (ERP) For Existing Pulverized Fuel Fired Thermal Power Plants

COMBUSTION EFFICIENCY

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

Industry Product Siloheight Status Chemical ABS pellet 3m good Chemical ABS Powder, PP & PE Pellet etc good Chemical Activated carbon 3m watch out

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

1470 SERIES HOT AIR GAS BURNER

Methods of combustion in combustion chambers that are specially adapted for generation of combustion products of high pressure or high velocity.

Chapter 5 Oxygen Based NOx Control

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

Development of a Fuel-Flexible Burner for Process Plants American Flame Research Committee Annual Meeting Salt Lake City, Utah September 5 7, 2012

THERMOELECTRIC GENERATOR

PETroleum CARBON FUEL (PCF)

ZEECO BURNER DIVISION

New PW Coke Oven Batteries 2A & 2B for JFE Steel Corporation at Kurashiki Plant

DATA SHEET. Model: TG4 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL

COMMERCIAL BOILERS Eco-HK / Eco-PK KW

ETAMAT - Recuperator Gas Burner A New Generation

Power Plant and Process Burners

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency

Combustion Control Problem Solution Combustion Process

Design Features and Commissioning of the 700 MW Coal-Fired Boiler at the Tsuruga Thermal Power Station No. 2

all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

CUSTOMS TARIFF - SCHEDULE V - 1

VIESMANN. VITOMAX 100-HS High pressure steam boiler Steam output 1.0 to 6.4 t/h. Datasheet. VITOMAX 100-HS Type M33A. Part no. and prices on request

in ultra-low NOx lean combustion grid plate

John Zink # United Kingdom

HOTDISC combustion device

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

Q1. The table shows how much carbon dioxide is produced when you transfer the same amount of energy by burning coal, gas and oil.

COMBUSTION RESEARCH AND TEST FACILITY

Converting to Natural Gas for MATs Compliance August 7, 2014

Construction. Function. Application area. Jet filter Shock-p ressure tig ht. Model DE / 2 / 1

Specifications of STICKTITE and PILOTPAK Nozzles

\Performance of the Regenerative Burners in BaoSteel 2050 Hot Strip Mill Furnace Baoshan, China

CUSTOMS TARIFF - SCHEDULE. Chapter 27 MINERAL FUELS, MINERAL OILS AND PRODUCTS OF THEIR DISTILLATION; BITUMINOUS SUBSTANCES; MINERAL WAXES

AIR CLASSIFIERS FOR INDUSTRIAL MINERALS CTM SERIES

Fuels, Combustion and Environmental Considerations in Industrial Gas Turbines - Introduction and Overview

Industrial Steam Turbines. The comprehensive product range from 2 to 250 megawatts. Answers for energy.

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

NICHOLS CONFINED SPACE ENTRY LIST


Chamber Kilns, Heated from Five Sides

BBC Multi-fuel Combination Beta Burner

Transcription:

HOT GAS GENERATOR COMBUSTION CHAMBERS System Dr. Schoppe for PULVERIZED LIGNITE fuel oil and gas from 100 kw up to 300 MW CARBOTECHNIK Hot gas generator 40 MW for pulverized lignite, fuel oil and sewer gas during erection in a sugar factory. On the left side standing the hot gas generator and on the right hand side the rotary dryer. Complete firing plants with silo, dosing machine, assembly and the commissioning Reliable customer service. Service and assembly from one hand CARBOTECHNIK ENERGIESYSTEME GMBH Lauterbachstr. 12, 82538 Geretsried-Gelting Telefon 08171/92 82-0 Telefax 08171/92 82-79

The industrial firing with the lowest operating costs Hot gas generator 8,5 MW pulverized lignite on a rotary sand dryer. We build gas generators and industrial combustion chambers on the basis of 30 years research and development. The oldest burners are since 1984, in operation, at the customers satisfaction, without repair. The basis is the dicovery of a flow effect, who allows to build even the biggest hot gas generator whitout refractory lining. They are long-lived and complete insensitive against fast temperature changes. From the cold state to full load they require 1 2 minutes. No starting shuttor or chimney. The hole plant is very simple. On this base we are building hot gas generators in 2 standard series as well as combustion chambers in special design for pulverized lignite, fuel oil and gas. 1. hot gas generator open series up to 15 MW, 850 C, whitout flue gas recirculation, whithout refractory 2. hot gas generator with mixing chamber up to 45 MW, 850 C, with flue gas recirculation, whitout refractory 3. combustion chambers in special design up to 300 MW, 1400 C, back pressure up to 6 bar Please ask for our list of references Hot gas generators.

1. Hot gas generator Open Series Hot gas generator 14 MW pulverized lignite in an asphalt plant Functioning The main part is a conical combustion chamber of chromium steel. The flame is separated from the chamber wall by a very stable cold air layer. The flame length depends on the fuelair-ratio:

Hot gas generator Open Series capacity, dimensions B A Max. capacity (at p = 500 mm WG) Typ HO 5 HO 7 HO 8,5 HO 12 HO 16 HO 22 hot gas flow 8.256 12.336 16.464 21.128 30.270 43.240 m³ n /h air flow 8.035 11.962 15.956 20.541 29.350 41.930 m³ n /h fuel flow 2,88 4,28 5,72 7,36 10,51 15,02 MW at 850 C Dimensions (for all fuels) lenght L 2300 2760 2890 3530 4080 4840 mm diameter D 950 1100 1250 1400 1600 1800 mm air inlet A x B 450 x 355 560 x 450 630 x 560 710 x 560 900 x 710 1000 x 800 mm² DIN 24154 Modifications reserved.

Hot gas generator Open Series Model selection type required air-pressure hot gas flow m³ n/h Reading example for 15000 m³ n /h can be used: a) Type HO 16 at 120 mm WG b) or Typ HO 12 at 230 mm WG c) or Typ HO 8,5 at 410 mm WG Selection depending on the repuired turn-down of the hot gas flow. Fuels Hot gas temperature - pulverized coal, lignite or biomass - light fuel oil - gas (natural, propane) At every hot gas flow a temperature between 300 C and 850 C can be obtained by controlling the fuel flow. Higher temperatures on request. The hot gas generator has no upper capacity limit, but the repuired air pressure increases with the square of the air flow at a given generator size. So the generator size has to be selected according to the available air pressure. Usually we recommend air pressure not exneeding 500 mm WG.

2. Hot gas generator with mixing chamber - operation with flue gas recirculation. - stoichiometric firing, thus saving up to 10 % of the fuel costs. No refractory. About 2 minutes from start to full capacity. Hot gas generator 21 MW pulverized lignite for the raw material drying in a cement plant. Center: Hot gas generator Down right: pulverized lignite silo Hot gas 200 800 C Capacity 5 43 MW Hot gas flow 48000 168000 m³ n /h Fuels (alternative) - pulverized lignite, coal, wood - light fuel oil, gas.

Hot gas generator with mixing chamber Flow rates, dimensions The burner is firing a flame jet of 60 100 m/s downwards into the mixing chamber. Thereby the flame gas become intensely admixed with the recycled gas. The burner works without excess air. Accordingly the flue gas amount is small. You saves thereby: - almost the half of the filter costs, - as far as 10 % of the fuel costs. It is worth while to calculate this hot gas generator very carefully. - burner type L 7 L 8,5 L 12 L 16 L 22 ---- - firing rate (max.) 12,5 16,6 21,4 30,6 43,7 MW - air flow 11962 15956 20541 29350 41930 m³ n /h - hot gas flow at 700 C 48.210 64.340 82.780 118.300 168.000 m³ n /h - burner diameter d 1200 1300 1500 1700 1900 mm high h 1800 2080 2350 2820 3360 mm - mixing chamber diameter D 2800 3100 3400 3900 4400 mm high H 8,44 9,34 10,24 11,75 13,26 m - hot gas - exit D A 1500 1700 2000 2300 2800 mm Modifications reserved.

Hot gas generator with a mixing chamber This is our proven high velocity burner without refractory. Fuels - pulverized lignite - light fuel oil - gas (natural, propane) The capacity rates as shown below are based on soichiometric combustion (air-fuel-ratio = 1,0). For more details ask for our brochure Impulse Burner. Hot gas generator 15 MW pulverized lignite for heating a cement mill, under construction.

3. Combustion chamber of special design Two lines are well proven: - Combustion chamber with counter chamber - Special designs 3.1 Combustion chamber with counter chamber - hot gas up to 1400 C, with refractory - operation with flue gas recirculation or excess air - very uniform temperature distribution - back pressure up to 6 bar - all liquid and gaseous fuels, including blast furnace gas Functioning An impulse burner and a mixing chamber are arranged in counter flow. The burner blows his flame jet with 60 80 m/s into the central back flow of the mixing chamber: Hot gas generator 250 kw (light fuel oil) for the stand still inertisation of a coal milling plant.

zu 3.1 Combustion chamber with counter chamber Combustion chamber 12 MW (heavy fuel oil, gas) for the heating of a calcining plant, 1400 C, back pressure 1 bar Hot gas generator 5,8 MW blast-furnace gas at a coal mill in a steel plant. In the front right side is the vertical coal mill.

Hot gas generator System Dr. Schoppe Special Design CARBOTECHNIK Some basic research and over 30 years experience allows us to supply custom made combustion chambers. So far we have build the world wide biggest as well as the smallest hot gas generator. Examples: 1. Three-step hot gas generator as a environment-friendly ground flare in a german chemical plant. - capacity 290 MW - hight: 30 m - fuel: gaseous production wastes

2. Hot gas generator for the cracking of hydrocarbons. Dimensions: - 20 mm - lenght 40 mm - 2,4 x speed of sound - stat. pressure 6 bar (Ü) - residence time circa 0,4 x 10-5 sec. CARBOTECHNIK Energiesysteme GmbH Lauterbachstr. 12 82538 Geretsried-Gelting Telefon +49 / 8171 / 92 82-0 Telefax +49 / 8171 / 92 82-79 Homepage: E-mail: www.carbotechnik.de info@carbotechnik.de